Craig C. Morris
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Craig C. Morris has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Alice McArthur
Sarver Heart Center, University of Arizona, Tucson, USA
1 shared publicationAshraf Samhan
1 shared publication- Babak Nazer
Division of Cardiology, University of Washington, Seattle, Washington, USA
1 shared publication David Giraud
1 shared publicationFiras E. Zahr
1 shared publicationGurion Lantz
1 shared publication
Latest Publications
- 1 June 2023
- Published by HMP Communications, LLC in Journal of Invasive Cardiology
- Vol. 35 (6) , E291-E293
Intermediate-Term Outcomes Following Transcatheter Aortic Valve Implantation in Patients with a History of Chest Radiation Therapy: A Propensity Score Matched Analysis
Chest radiation therapy (XRT) has been associated with a higher rate of mortality following surgical aortic valve replacement. We performed a single-center retrospective analysis of patients with severe AS who underwent TAVI from 01/01/2012 to 07/31/2020 comparing patients with and without XRT. A total of 915 patients met inclusion criteria, with a total of fifty patients found to have a history of XRT. Original Contribution from Journal of Invasive Cardiology. aortic stenosis Transcatheter aortic valve implantation radiation therapy Outcomes
- 1 June 2023
- Published by HMP Communications, LLC in Journal of Invasive Cardiology
- Vol. 35 (6) , E291-E293
Intermediate-Term Outcomes Following Transcatheter Aortic Valve Implantation in Patients with a History of Chest Radiation Therapy: A Propensity Score Matched Analysis
Chest radiation therapy (XRT) has been associated with a higher rate of mortality following surgical aortic valve replacement. We performed a single-center retrospective analysis of patients with severe AS who underwent TAVI from 01/01/2012 to 07/31/2020 comparing patients with and without XRT. A total of 915 patients met inclusion criteria, with a total of fifty patients found to have a history of XRT. Original Contribution from Journal of Invasive Cardiology. aortic stenosis Transcatheter aortic valve implantation radiation therapy Outcomes
- Open Access
- 8 March 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-10
Free-breathing gradient recalled echo-based CMR in a swine heart failure model
In swine models, there are well-established protocols for creating a closed-chest myocardial infarction (MI) as well as protocols for characterization of cardiac function with cardiac magnetic resonance (CMR). This methods manuscript outlines a novel technique in CMR data acquisition utilizing smart-signal gradient recalled echo (GRE)-based array sequences in a free-breathing swine heart failure model allowing for both high spatial and temporal resolution imaging. Nine male Yucatan mini swine weighing 48.7 ± 1.6 kg at 58.2 ± 3.1 weeks old underwent the outlined imaging protocol before and 1-month after undergoing closed chest left anterior descending coronary artery (LAD) occlusion/reperfusion. The left ventricular ejection fraction (LVEF) at baseline was 59.3 ± 2.4% and decreased to 48.1 ± 3.7% 1-month post MI (P = 0.029). The average end-diastolic volume (EDV) at baseline was 55.2 ± 1.7 ml and increased to 74.2 ± 4.2 ml at 1-month post MI (P = 0.001). The resulting images from this novel technique and post-imaging analysis are presented and discussed. In a Yucatan swine model of heart failure via closed chest left anterior descending coronary artery (LAD) occlusion/reperfusion, we found that CMR with GRE-based array sequences produced clinical-grade images with high spatial and temporal resolution in the free-breathing setting.
- 8 March 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-10
Open AccessFree-breathing gradient recalled echo-based CMR in a swine heart failure model
In swine models, there are well-established protocols for creating a closed-chest myocardial infarction (MI) as well as protocols for characterization of cardiac function with cardiac magnetic resonance (CMR). This methods manuscript outlines a novel technique in CMR data acquisition utilizing smart-signal gradient recalled echo (GRE)-based array sequences in a free-breathing swine heart failure model allowing for both high spatial and temporal resolution imaging. Nine male Yucatan mini swine weighing 48.7 ± 1.6 kg at 58.2 ± 3.1 weeks old underwent the outlined imaging protocol before and 1-month after undergoing closed chest left anterior descending coronary artery (LAD) occlusion/reperfusion. The left ventricular ejection fraction (LVEF) at baseline was 59.3 ± 2.4% and decreased to 48.1 ± 3.7% 1-month post MI (P = 0.029). The average end-diastolic volume (EDV) at baseline was 55.2 ± 1.7 ml and increased to 74.2 ± 4.2 ml at 1-month post MI (P = 0.001). The resulting images from this novel technique and post-imaging analysis are presented and discussed. In a Yucatan swine model of heart failure via closed chest left anterior descending coronary artery (LAD) occlusion/reperfusion, we found that CMR with GRE-based array sequences produced clinical-grade images with high spatial and temporal resolution in the free-breathing setting.
- 1 December 2020
- Published by Elsevier in The American Journal of Medicine
- Vol. 133 (12) , e727-e728
Hepatic Sarcoidosis Presenting as Hypercalcemia
- 1 December 2020
- Published by Elsevier in The American Journal of Medicine
- Vol. 133 (12) , e727-e728
Hepatic Sarcoidosis Presenting as Hypercalcemia