Khandjamts Batjargal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Khandjamts Batjargal has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Feridun Boylu
Department of Mineral Processing Engineering, Faculty of Mines, Istanbul Technical University, 34469 Istanbul, Turkey
6 shared publications - Mehmet Sabri Celik
Istanbul Technical University
6 shared publications - Onur Guven
Department of Mining Engineering, Faculty of Engineering, Adana Alparslan Turkes Science and Technology University, 01250 Adana, Turkey
6 shared publications - Orhan Ozdemir
Department of Mineral Processing Engineering, Faculty of Mines, Istanbul Technical University, 34469 Istanbul, Türkiye
6 shared publications - Nikolay Alexandrov Grozev
Department of Physical Chemistry, Sofia University, 1 James Bourchier Avenue, 1164 Sofia, Bulgaria
4 shared publications - Stoyan Ivanov Karakashev
Faculty of Natural Sciences, University of Shumen, 9700 Shumen, Bulgaria
4 shared publications
Latest Publications
- Open Access
Dependence of Bubble Size on Magnesite Flotation Recovery Using Sodium Oleate (NaOL) with Different Frothers
Developments of new research tools in flotation studies, including bubble–particle attachment time efficiency and dynamic froth analysis, can help improve our understanding of particle–bubble interactions in flotation processes. In particular, the selection of new collectors and frothers, and their mixtures can provide a wide distribution of bubble sizes at their respective concentrations. In the literature, several studies have reported the effect of different frothers and collector mixtures on bubble characteristics like bubble size and critical coalescence concentration (CCC). The general trend obtained from these studies showed that the addition of frothers, along with collectors, which also act as frothers during flotation, resulted in finer bubbles and required lower concentrations of frothers, which in turn positively affected the flotation recoveries. In this study, an attempt was made to study fine-sized magnesite in the presence of sodium oleate (NaOL) and five different types of frothers (PPG600, PPG400, BTPG, BDPG, and MIBC). Bubble–particle attachment time with different sized capillary tubes and dynamic froth analysis values in a liquid–air system, along with flotation recoveries in a micro-flotation cell, were interpreted to show possible correlations and provide an optimum bubble/particle size ratio in the presence of different frothers.
Open AccessDependence of Bubble Size on Magnesite Flotation Recovery Using Sodium Oleate (NaOL) with Different Frothers
Developments of new research tools in flotation studies, including bubble–particle attachment time efficiency and dynamic froth analysis, can help improve our understanding of particle–bubble interactions in flotation processes. In particular, the selection of new collectors and frothers, and their mixtures can provide a wide distribution of bubble sizes at their respective concentrations. In the literature, several studies have reported the effect of different frothers and collector mixtures on bubble characteristics like bubble size and critical coalescence concentration (CCC). The general trend obtained from these studies showed that the addition of frothers, along with collectors, which also act as frothers during flotation, resulted in finer bubbles and required lower concentrations of frothers, which in turn positively affected the flotation recoveries. In this study, an attempt was made to study fine-sized magnesite in the presence of sodium oleate (NaOL) and five different types of frothers (PPG600, PPG400, BTPG, BDPG, and MIBC). Bubble–particle attachment time with different sized capillary tubes and dynamic froth analysis values in a liquid–air system, along with flotation recoveries in a micro-flotation cell, were interpreted to show possible correlations and provide an optimum bubble/particle size ratio in the presence of different frothers.
- 6 August 2025
- Published by Springer Nature in JOM
- Vol. 78 (2) , 1150-1163
Effect of Innovative Mixed Collectors on the Improvement of Flotation Recovery of Lepidolite-Spodumene Ore
- 6 August 2025
- Published by Springer Nature in JOM
- Vol. 78 (2) , 1150-1163
Effect of Innovative Mixed Collectors on the Improvement of Flotation Recovery of Lepidolite-Spodumene Ore
- Open Access
Correlation of Flotation Recoveries and Bubble–Particle Attachment Time for Dodecyl Ammonium Hydrochloride/Frother/Quartz Flotation System
Recent studies in the flotation of fine particles have necessitated new techniques and analyses for developing various strategies. Particularly, the improvements in flotation chemistry including the selection of the type of frother, collector, and other reagents have become very significant. In this study, the effect of different commercial polypropylene glycol frothers (PPG200, 400, and 600) in the presence of dodecylammonium hydrochloride (DAH) was investigated for their contribution to flotation recoveries and bubble–particle attachment time values of fine quartz minerals. Zeta potential measurements with DAH were also carried out as a function of pH and reagent concentration to justify the effect of collector usage alone on the charge of particles. A linear increase in flotation recoveries against collector concentration, e.g., 7.4% recovery at 1 × 10−5 mol/L DAH and 65.4% recovery at 1 × 10−3 mol/L DAH, was obtained. In this context, the contribution of frothers was particularly important in that a recovery of 15.91% in the absence of the frother and a modest increase to 19.70% was obtained upon the addition of PPG600 at its critical coalescence concentration (CCC) of 3 ppm. Finally, a strong correlation was found between the bubble–particle attachment time and flotation recovery as a function of collector concentration (lowest attachment time vs. highest flotation recovery). The latter correlation is very promising because bubble attachment time leads to various micro-mechanisms in flotation including bubble film thinning, bubble rupture, and induction time, and consequently, frother efficiency in the presence and absence of a collector. As a result, the experimental findings were gathered to achieve a consistent base for further fundamental studies on the application of the synergistic effect of frothers and collectors in the flotation of fine particles.
Open AccessCorrelation of Flotation Recoveries and Bubble–Particle Attachment Time for Dodecyl Ammonium Hydrochloride/Frother/Quartz Flotation System
Recent studies in the flotation of fine particles have necessitated new techniques and analyses for developing various strategies. Particularly, the improvements in flotation chemistry including the selection of the type of frother, collector, and other reagents have become very significant. In this study, the effect of different commercial polypropylene glycol frothers (PPG200, 400, and 600) in the presence of dodecylammonium hydrochloride (DAH) was investigated for their contribution to flotation recoveries and bubble–particle attachment time values of fine quartz minerals. Zeta potential measurements with DAH were also carried out as a function of pH and reagent concentration to justify the effect of collector usage alone on the charge of particles. A linear increase in flotation recoveries against collector concentration, e.g., 7.4% recovery at 1 × 10−5 mol/L DAH and 65.4% recovery at 1 × 10−3 mol/L DAH, was obtained. In this context, the contribution of frothers was particularly important in that a recovery of 15.91% in the absence of the frother and a modest increase to 19.70% was obtained upon the addition of PPG600 at its critical coalescence concentration (CCC) of 3 ppm. Finally, a strong correlation was found between the bubble–particle attachment time and flotation recovery as a function of collector concentration (lowest attachment time vs. highest flotation recovery). The latter correlation is very promising because bubble attachment time leads to various micro-mechanisms in flotation including bubble film thinning, bubble rupture, and induction time, and consequently, frother efficiency in the presence and absence of a collector. As a result, the experimental findings were gathered to achieve a consistent base for further fundamental studies on the application of the synergistic effect of frothers and collectors in the flotation of fine particles.
- Open Access
Frothing Performance of Frother-Collector Mixtures as Determined by Dynamic Foam Analyzer and Its Implications in Flotation
In recent years, most of the studies have been adapted to determine the optimum conditions for the flotation of very fine minerals. In this context, besides parameters such as particle size, morphology, and pH, the effects of frother type and its concentration present a very significant role in optimizing the flotation conditions. Therefore, the effects of froth stability during flotation can be considered one of the most important issues. Considering that knowledge in mind, in this study, the foamability and froth decay rate of six frothers (PPG200, PPG400, PPG600, BTEG, BTPG, and BDPG) having different molecular weights but similar polyglycol structures were investigated. In addition, methyl isobutyl carbinol (MIBC) which is a well-known frother type in the industry was also used as a reference. Additionally, a series of tests were also performed in the presence of collectors (Dodecylamine hydrochloride, DAH, and sodium oleate, NaOL) + frother mixtures to mimic the flotation conditions. The results of these tests indicated that the bubble size became finer at even low concentrations of PPG600 and PPG400 frothers. Following that, a significant decrease in bubble size was also found for the collector + frother mixtures system regardless of the concentration of the frothers.
Open AccessFrothing Performance of Frother-Collector Mixtures as Determined by Dynamic Foam Analyzer and Its Implications in Flotation
In recent years, most of the studies have been adapted to determine the optimum conditions for the flotation of very fine minerals. In this context, besides parameters such as particle size, morphology, and pH, the effects of frother type and its concentration present a very significant role in optimizing the flotation conditions. Therefore, the effects of froth stability during flotation can be considered one of the most important issues. Considering that knowledge in mind, in this study, the foamability and froth decay rate of six frothers (PPG200, PPG400, PPG600, BTEG, BTPG, and BDPG) having different molecular weights but similar polyglycol structures were investigated. In addition, methyl isobutyl carbinol (MIBC) which is a well-known frother type in the industry was also used as a reference. Additionally, a series of tests were also performed in the presence of collectors (Dodecylamine hydrochloride, DAH, and sodium oleate, NaOL) + frother mixtures to mimic the flotation conditions. The results of these tests indicated that the bubble size became finer at even low concentrations of PPG600 and PPG400 frothers. Following that, a significant decrease in bubble size was also found for the collector + frother mixtures system regardless of the concentration of the frothers.
- Open Access
Adsorption Kinetics of Various Frothers on Rising Bubbles of Different Sizes under Flotation Conditions
This paper studies the effect of the type and concentration of selected frothers, the gas flowrate, and the pore size of the porous frit on the bubble sizes (Sauter mean diameter, SMD) of bubbling flow produced in a micro-flotation cell, and the determination of bubble size distribution (BSD) in the presence of the frothers. The commercial frothers polypropylene glycols (PPG 200, 400, and 600), tri propylene glycol (BTPG), triethylene glycol (BTEG), dipropylene glycol (BDPG), and Methyl Isobutyl Carbinol (MIBC) were used in the present investigation. The frother concentration varied from 1 to 1000 ppm. The flow rate varied in the range of 25 to 100 cm3/min. The pore sizes of the frit were selected as 10–16 μm, 16–40 μm, and 40–100 μm. Each frother exhibited its own unique ability in preventing coalescence of the bubbles in the order of BTEG < BDPG < PPG 200 < MIBC < BTPG < PPG 400 < PPG 600. The factorial experiments established that the type of the frother and its concentration have a major effect on the size of the bubbles. The bubbles decreased twice their size when the frother concentration was increased from 1 ppm to 1000 ppm. The pore size of the frit is a significant factor as well. The size of the bubbles can be reduced from about 10% to about 40% by decreasing the pores from 40–100 μm to 10–16 μm but the level of this decrease depends on the type of the frother. The increase of the flowrate from 25 cm3/min to 100 cm3/min produced bubbles smaller by 25% to 50% for the case of BTEG, BDPG, PPG 200, MIBC, BTPG, while a minimum of the bubble sizes was reached for the case of PPG 400 and PPG 600, beyond which the bubbles enlarged their size. The BSD in the presence of PPG 600 varied around 0.3 mm, whereas BTEG gave a wider BSD which indicated that the type of frother affected the bubble production. Our analysis shows that the first group of frothers adsorbs instantly on the bubbles, once they leave the porous frit, thus reaching equilibrium. PPG 400 and PPG 600 adsorb significantly slower on the bubbles, possibly not reaching equilibrium during their resident time.
Open AccessAdsorption Kinetics of Various Frothers on Rising Bubbles of Different Sizes under Flotation Conditions
This paper studies the effect of the type and concentration of selected frothers, the gas flowrate, and the pore size of the porous frit on the bubble sizes (Sauter mean diameter, SMD) of bubbling flow produced in a micro-flotation cell, and the determination of bubble size distribution (BSD) in the presence of the frothers. The commercial frothers polypropylene glycols (PPG 200, 400, and 600), tri propylene glycol (BTPG), triethylene glycol (BTEG), dipropylene glycol (BDPG), and Methyl Isobutyl Carbinol (MIBC) were used in the present investigation. The frother concentration varied from 1 to 1000 ppm. The flow rate varied in the range of 25 to 100 cm3/min. The pore sizes of the frit were selected as 10–16 μm, 16–40 μm, and 40–100 μm. Each frother exhibited its own unique ability in preventing coalescence of the bubbles in the order of BTEG < BDPG < PPG 200 < MIBC < BTPG < PPG 400 < PPG 600. The factorial experiments established that the type of the frother and its concentration have a major effect on the size of the bubbles. The bubbles decreased twice their size when the frother concentration was increased from 1 ppm to 1000 ppm. The pore size of the frit is a significant factor as well. The size of the bubbles can be reduced from about 10% to about 40% by decreasing the pores from 40–100 μm to 10–16 μm but the level of this decrease depends on the type of the frother. The increase of the flowrate from 25 cm3/min to 100 cm3/min produced bubbles smaller by 25% to 50% for the case of BTEG, BDPG, PPG 200, MIBC, BTPG, while a minimum of the bubble sizes was reached for the case of PPG 400 and PPG 600, beyond which the bubbles enlarged their size. The BSD in the presence of PPG 600 varied around 0.3 mm, whereas BTEG gave a wider BSD which indicated that the type of frother affected the bubble production. Our analysis shows that the first group of frothers adsorbs instantly on the bubbles, once they leave the porous frit, thus reaching equilibrium. PPG 400 and PPG 600 adsorb significantly slower on the bubbles, possibly not reaching equilibrium during their resident time.
- Open Access
Experimental Procedure for the Determination of the Critical Coalescence Concentration (CCC) of Simple Frothers
In this study, the critical coalescence concentrations (CCC) of selected commercial frother solutions, namely polypropylene glycols (PPG 200, 400, and 600), tri propylene glycol (BTPG), triethylene glycol (BTEG), dipropylene glycol (BDPG), and as a reference, methyl isobutyl carbinol (MIBC), were determined using a bubble column based on light absorption. The results for all seven frothers showed that BTEG has the worst bubble inhibiting performance, and PPG 600 has the best bubble inhibiting performance. While critical coalescence concentration (CCC) was found as 3 ppm for PPG 600, it increased to 25 ppm for BTEG. In the case of MIBC, which was the reference point, the CCC value was found as 10 ppm, which was consistent with the literature. The surface tension isotherms of the frothers were determined and analyzed with one of the latest adsorption models. The results indicated that the polypropylene glycol frothers showed more surface activity compared to alcohol or other frothers investigated. This is due to the additional reorganization of the PPG molecules on the air/water interface, thus boosting its surface activity.
Open AccessExperimental Procedure for the Determination of the Critical Coalescence Concentration (CCC) of Simple Frothers
In this study, the critical coalescence concentrations (CCC) of selected commercial frother solutions, namely polypropylene glycols (PPG 200, 400, and 600), tri propylene glycol (BTPG), triethylene glycol (BTEG), dipropylene glycol (BDPG), and as a reference, methyl isobutyl carbinol (MIBC), were determined using a bubble column based on light absorption. The results for all seven frothers showed that BTEG has the worst bubble inhibiting performance, and PPG 600 has the best bubble inhibiting performance. While critical coalescence concentration (CCC) was found as 3 ppm for PPG 600, it increased to 25 ppm for BTEG. In the case of MIBC, which was the reference point, the CCC value was found as 10 ppm, which was consistent with the literature. The surface tension isotherms of the frothers were determined and analyzed with one of the latest adsorption models. The results indicated that the polypropylene glycol frothers showed more surface activity compared to alcohol or other frothers investigated. This is due to the additional reorganization of the PPG molecules on the air/water interface, thus boosting its surface activity.
- Open Access
Correlations for Easy Calculation of the Critical Coalescence Concentration (CCC) of Simple Frothers
Can the critical coalescence concentration (CCC) of the flotation frothers be predictable? What is the relation between their molecular structure and their CCC values? A literature survey found specific correlations between the hydrophilic-lipophilic balances (HLB) and HLB/Mw (where Mw stands for the molecular mass) of homologue series of frothers and their CCC values, but the results are invalid when the molecule’s functional groups change. For this reason, 37 frothers with known values of CCC were analyzed. The CCC values of seven frothers were determined, and the rest were taken from the literature. The frothers were subdivided in homologue series with an increasing number of the carbon atoms with an account for the type and the location of the functional group, thus deriving three types of correlations lnCCC = f(HLB) applicable for: (i) alcohols; (ii) propylene glycols alkyl ethers and propylene glycols; (iii) ethylene glycols alkyl ethers. The average accuracy of these correlations between CCC and HLB is 93%.
Open AccessCorrelations for Easy Calculation of the Critical Coalescence Concentration (CCC) of Simple Frothers
Can the critical coalescence concentration (CCC) of the flotation frothers be predictable? What is the relation between their molecular structure and their CCC values? A literature survey found specific correlations between the hydrophilic-lipophilic balances (HLB) and HLB/Mw (where Mw stands for the molecular mass) of homologue series of frothers and their CCC values, but the results are invalid when the molecule’s functional groups change. For this reason, 37 frothers with known values of CCC were analyzed. The CCC values of seven frothers were determined, and the rest were taken from the literature. The frothers were subdivided in homologue series with an increasing number of the carbon atoms with an account for the type and the location of the functional group, thus deriving three types of correlations lnCCC = f(HLB) applicable for: (i) alcohols; (ii) propylene glycols alkyl ethers and propylene glycols; (iii) ethylene glycols alkyl ethers. The average accuracy of these correlations between CCC and HLB is 93%.