Sebastian Żurek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sebastian Żurek has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Przemysław Guzik
Department of Cardiology-Intensive Therapy and Internal Medicine, Poznan University of Medical Sciences, Poznan, Poland
10 shared publications - Jarosław Piskorski
Institute of Physics, University of Zielona Gora, Zielona Gora, Poland
7 shared publications - Bartosz Biczuk
Institute of Physics, University of Zielona Góra, 65-069 Zielona Góra, Poland
4 shared publications Jaroslaw Piskorski
Institute of Physics, University of Zielona Gora, Zielona Gora, Poland
3 shared publicationsMarcin Kosmider
Institute of Physics, University of Zielona Gora, Zielona Gora, Poland
3 shared publications- Elżbieta Turska
Institute of Pedagogy, University of Zielona Gora, 65-417 Zielona Gora, Poland
2 shared publications
Latest Publications
- 20 March 2026
- Published by Springer Nature in The European Physical Journal Special Topics
- Vol. 235 (31) , 8927-8941
Examination of runs entropy: theoretical insights and practical applications in polysomnographic analysis
- 20 March 2026
- Published by Springer Nature in The European Physical Journal Special Topics
- Vol. 235 (31) , 8927-8941
Examination of runs entropy: theoretical insights and practical applications in polysomnographic analysis
- Open Access
Sleep Stage Classification Through HRV, Complexity Measures, and Heart Rate Asymmetry Using Generalized Estimating Equations Models
This study investigates whether heart rate asymmetry (HRA) parameters offer insights into sleep stages beyond those provided by conventional heart rate variability (HRV) and complexity measures. Utilizing 31 polysomnographic recordings, we focused exclusively on electrocardiogram (ECG) data, specifically the interval time series, to explore heart rate dynamics associated with different sleep stages. Employing both statistical techniques and machine learning models, with the Generalized Estimating Equation model as the foundational approach, we assessed the effectiveness of HRA in identifying and differentiating sleep stages and transitions. The models including asymmetric variables for detecting deep sleep stages, N2 and N3, achieved AUCs of 0.85 and 0.89, respectively, those for transitions N2–R, R–N2, i.e., falling in and out of REM sleep, achieved AUCs of 0.85 and 0.80, and those for W–N1, i.e., falling asleep, an AUC of 0.83. All these models were highly statistically significant. The findings demonstrate that HRA parameters provide significant, independent information about sleep stages that is not captured by HRV and complexity measures alone. This additional insight into sleep physiology potentially leads to a better understanding of hearth rhythm during sleep and devising more precise diagnostic tools, including cheap portable devices, for identifying sleep-related disorders.Open AccessSleep Stage Classification Through HRV, Complexity Measures, and Heart Rate Asymmetry Using Generalized Estimating Equations Models
This study investigates whether heart rate asymmetry (HRA) parameters offer insights into sleep stages beyond those provided by conventional heart rate variability (HRV) and complexity measures. Utilizing 31 polysomnographic recordings, we focused exclusively on electrocardiogram (ECG) data, specifically the interval time series, to explore heart rate dynamics associated with different sleep stages. Employing both statistical techniques and machine learning models, with the Generalized Estimating Equation model as the foundational approach, we assessed the effectiveness of HRA in identifying and differentiating sleep stages and transitions. The models including asymmetric variables for detecting deep sleep stages, N2 and N3, achieved AUCs of 0.85 and 0.89, respectively, those for transitions N2–R, R–N2, i.e., falling in and out of REM sleep, achieved AUCs of 0.85 and 0.80, and those for W–N1, i.e., falling asleep, an AUC of 0.83. All these models were highly statistically significant. The findings demonstrate that HRA parameters provide significant, independent information about sleep stages that is not captured by HRV and complexity measures alone. This additional insight into sleep physiology potentially leads to a better understanding of hearth rhythm during sleep and devising more precise diagnostic tools, including cheap portable devices, for identifying sleep-related disorders. - Open Access
pRR30, pRR3.25% and Asymmetrical Entropy Descriptors in Atrial Fibrillation Detection
Background: Early detection of atrial fibrillation (AF) is essential to prevent stroke and other cardiac and embolic complications. We compared the diagnostic properties for AF detection of the percentage of successive RR interval differences greater than or equal to 30 ms or 3.25% of the previous RR interval (pRR30 and pRR3.25%, respectively), and asymmetric entropy descriptors of RR intervals. Previously, both pRR30 and pRR3.25% outperformed many other heart rate variability (HRV) parameters in distinguishing AF from sinus rhythm (SR) in 60 s electrocardiograms (ECGs). Methods: The 60 s segments with RR intervals were extracted from the publicly available Physionet Long-Term Atrial Fibrillation Database (84 recording, 24 h Holter ECG). There were 31,753 60 s segments of AF and 32,073 60 s segments of SR. The diagnostic properties of all parameters were analysed with receiver operator curve analysis, a confusion matrix and logistic regression. The best model with pRR30, pRR3.25% and total entropic features (H) had the largest area under the curve (AUC)—0.98 compared to 0.959 for pRR30—and 0.972 for pRR3.25%. However, the differences in AUC between pRR30 and pRR3.25% alone and the combined model were negligible from a practical point of view. Moreover, combining pRR30 and pRR3.25% with H significantly increased the number of false-negative cases by more than threefold. Conclusions: Asymmetric entropy has some potential in differentiating AF from SR in the 60 s RR interval time series, but the addition of these parameters does not seem to make a relevant difference compared to pRR30 and especially pRR3.25%.
Open AccesspRR30, pRR3.25% and Asymmetrical Entropy Descriptors in Atrial Fibrillation Detection
Background: Early detection of atrial fibrillation (AF) is essential to prevent stroke and other cardiac and embolic complications. We compared the diagnostic properties for AF detection of the percentage of successive RR interval differences greater than or equal to 30 ms or 3.25% of the previous RR interval (pRR30 and pRR3.25%, respectively), and asymmetric entropy descriptors of RR intervals. Previously, both pRR30 and pRR3.25% outperformed many other heart rate variability (HRV) parameters in distinguishing AF from sinus rhythm (SR) in 60 s electrocardiograms (ECGs). Methods: The 60 s segments with RR intervals were extracted from the publicly available Physionet Long-Term Atrial Fibrillation Database (84 recording, 24 h Holter ECG). There were 31,753 60 s segments of AF and 32,073 60 s segments of SR. The diagnostic properties of all parameters were analysed with receiver operator curve analysis, a confusion matrix and logistic regression. The best model with pRR30, pRR3.25% and total entropic features (H) had the largest area under the curve (AUC)—0.98 compared to 0.959 for pRR30—and 0.972 for pRR3.25%. However, the differences in AUC between pRR30 and pRR3.25% alone and the combined model were negligible from a practical point of view. Moreover, combining pRR30 and pRR3.25% with H significantly increased the number of false-negative cases by more than threefold. Conclusions: Asymmetric entropy has some potential in differentiating AF from SR in the 60 s RR interval time series, but the addition of these parameters does not seem to make a relevant difference compared to pRR30 and especially pRR3.25%.
- Open Access
- 26 January 2024
- Published by MDPI AG in Preprints.org
Statistical and Diagnostic Properties of pRR30, pRR3.25% and Asymmetrical Entropy Descriptors in Atrial Fibrillation Detection
Background: Early detection of atrial fibrillation (AF) is essential to prevent stroke and other cardiac and embolic complications. We compared the diagnostic properties for AF detection of the percentage of successive RR interval differences greater than or equal to 30 ms or 3.25% of the previous RR interval (pRR30 and pRR3.25%, respectively), and asymmetric entropy descriptors of RR intervals. Previously, both pRR30 and pRR3.25% outperformed many other heart rate variability (HRV) parameters in distinguishing AF from sinus rhythm (SR) in 60-second electrocardiograms (ECGs). Methods: The 60-s segments with RR intervals were extracted from the publicly available Physionet Long-Term Atrial Fibrillation Database (84 recording, 24-hour Holter ECG). There were 31753 60-s segments of AF and 32073 60-s segments of SR. The diagnostic properties of all parameters were analysed with the receiver operator curve analysis, confusion matrix and logistic regression. The best model with pRR30, pRR3.25% and total entropic features (H) had the largest area under the curve (AUC) – 0.98 compared to 0.959 for pRR30 - and 0.972 for pRR3.25%. However, the differences in AUC between pRR30, pRR3.25% alone and the combined model were negligible from a practical point of view. Moreover, combining pRR30, pRR3.25% with H significantly increased the number of false-negative cases by more than threefold. Conclusions: Asymmetric entropy has some potential in differentiating AF from SR in the 60-s RR interval time series, but the addition of these parameters does not seem to make a relevant difference compared to pRR30 and especially pRR3.25%.
- 26 January 2024
- Published by MDPI AG in Preprints.org
Open AccessStatistical and Diagnostic Properties of pRR30, pRR3.25% and Asymmetrical Entropy Descriptors in Atrial Fibrillation Detection
Background: Early detection of atrial fibrillation (AF) is essential to prevent stroke and other cardiac and embolic complications. We compared the diagnostic properties for AF detection of the percentage of successive RR interval differences greater than or equal to 30 ms or 3.25% of the previous RR interval (pRR30 and pRR3.25%, respectively), and asymmetric entropy descriptors of RR intervals. Previously, both pRR30 and pRR3.25% outperformed many other heart rate variability (HRV) parameters in distinguishing AF from sinus rhythm (SR) in 60-second electrocardiograms (ECGs). Methods: The 60-s segments with RR intervals were extracted from the publicly available Physionet Long-Term Atrial Fibrillation Database (84 recording, 24-hour Holter ECG). There were 31753 60-s segments of AF and 32073 60-s segments of SR. The diagnostic properties of all parameters were analysed with the receiver operator curve analysis, confusion matrix and logistic regression. The best model with pRR30, pRR3.25% and total entropic features (H) had the largest area under the curve (AUC) – 0.98 compared to 0.959 for pRR30 - and 0.972 for pRR3.25%. However, the differences in AUC between pRR30, pRR3.25% alone and the combined model were negligible from a practical point of view. Moreover, combining pRR30, pRR3.25% with H significantly increased the number of false-negative cases by more than threefold. Conclusions: Asymmetric entropy has some potential in differentiating AF from SR in the 60-s RR interval time series, but the addition of these parameters does not seem to make a relevant difference compared to pRR30 and especially pRR3.25%.
- Open Access
- 10 January 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (2) , 371
Obesity in Hypertensive Patients Is Characterized by a Dawn Phenomenon in Systolic Blood Pressure Values and Variability
One of the causes of hypertension is excess weight gain, which can also affect the course of this disease. Both the diagnosis and management of hypertension commonly use ambulatory blood pressure monitoring; the results of which correlate more strongly with cardiovascular diseases and cardiovascular death than office blood pressure monitoring. We evaluated blood pressure values and their variability from hour to hour to see if and when they differed between hypertensive patients with and without obesity. The study included 1345 patients who underwent 24 h ambulatory blood pressure monitoring and then were divided into groups according to body mass index and waist circumference. The obtained data were analyzed according to the subjects’ wake-up time, and short-term blood pressure variability parameters were calculated as the mean of the absolute values of the differences between consecutive measurements. The systolic blood pressure in obese subjects was significantly higher between 1 and 5 h before waking than in normal-weighted individuals. In turn, the variability in systolic and diastolic blood pressure was higher with increasing body mass index. The difference in systolic blood pressure values and blood pressure variability was most prominent in the last 5 h of sleep in obese patients.
- 10 January 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (2) , 371
Open AccessObesity in Hypertensive Patients Is Characterized by a Dawn Phenomenon in Systolic Blood Pressure Values and Variability
One of the causes of hypertension is excess weight gain, which can also affect the course of this disease. Both the diagnosis and management of hypertension commonly use ambulatory blood pressure monitoring; the results of which correlate more strongly with cardiovascular diseases and cardiovascular death than office blood pressure monitoring. We evaluated blood pressure values and their variability from hour to hour to see if and when they differed between hypertensive patients with and without obesity. The study included 1345 patients who underwent 24 h ambulatory blood pressure monitoring and then were divided into groups according to body mass index and waist circumference. The obtained data were analyzed according to the subjects’ wake-up time, and short-term blood pressure variability parameters were calculated as the mean of the absolute values of the differences between consecutive measurements. The systolic blood pressure in obese subjects was significantly higher between 1 and 5 h before waking than in normal-weighted individuals. In turn, the variability in systolic and diastolic blood pressure was higher with increasing body mass index. The difference in systolic blood pressure values and blood pressure variability was most prominent in the last 5 h of sleep in obese patients.
- Open Access
- 24 August 2022
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 60 (10) , 2969-2979
Associations between heart rate asymmetry expression and asymmetric detrended fluctuation analysis results
The relation between recently established asymmetry in Asymmetric Detrended Fluctuation Analysis (ADFA) and Heart Rate Asymmetry is studied. It is found that the ADFA asymmetric exponents are related both to the overall variability and to its asymmetric components at all studied time scales. We find that the asymmetry in scaling exponents, i.e., $$\alpha ^{+}<\alpha ^{-}$$ is associated with both variance-based and runs-based types of asymmetry. This observation suggests that the physiological mechanisms of both types are similar, even though their origins and mathematical methods are very different. Graphical The graphical abstract demonstrates strong, nonlinear association between the expression of Heart Rate Asymmetry measured using relative descriptors and the Asymmetric Detrended Fluctuation Analysis results. It is clear that there is a strong relation between the two theoretically disparate approaches to signal analysis. The technique to demonstrate the association is loess fit.- 24 August 2022
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 60 (10) , 2969-2979
Open AccessAssociations between heart rate asymmetry expression and asymmetric detrended fluctuation analysis results
The relation between recently established asymmetry in Asymmetric Detrended Fluctuation Analysis (ADFA) and Heart Rate Asymmetry is studied. It is found that the ADFA asymmetric exponents are related both to the overall variability and to its asymmetric components at all studied time scales. We find that the asymmetry in scaling exponents, i.e., $$\alpha ^{+}<\alpha ^{-}$$ is associated with both variance-based and runs-based types of asymmetry. This observation suggests that the physiological mechanisms of both types are similar, even though their origins and mathematical methods are very different. Graphical The graphical abstract demonstrates strong, nonlinear association between the expression of Heart Rate Asymmetry measured using relative descriptors and the Asymmetric Detrended Fluctuation Analysis results. It is clear that there is a strong relation between the two theoretically disparate approaches to signal analysis. The technique to demonstrate the association is loess fit. - Open Access
Relative Consistency of Sample Entropy Is Not Preserved in MIX Processes
Relative consistency is a notion related to entropic parameters, most notably to Approximate Entropy and Sample Entropy. It is a central characteristic assumed for e.g., biomedical and economic time series, since it allows the comparison between different time series at a single value of the threshold parameter r. There is no formal proof for this property, yet it is generally accepted that it is true. Relative consistency in both Approximate Entropy and Sample entropy was first tested with the process. In the seminal paper by Richman and Moorman, it was shown that Approximate Entropy lacked the property for cases in which Sample Entropy did not. In the present paper, we show that relative consistency is not preserved for processes if enough noise is added, yet it is preserved for another process for which we define a sum of a sinusoidal and a stochastic element, no matter how much noise is present. The analysis presented in this paper is only possible because of the existence of the very fast NCM algorithm for calculating correlation sums and thus also Sample Entropy.Open AccessRelative Consistency of Sample Entropy Is Not Preserved in MIX Processes
Relative consistency is a notion related to entropic parameters, most notably to Approximate Entropy and Sample Entropy. It is a central characteristic assumed for e.g., biomedical and economic time series, since it allows the comparison between different time series at a single value of the threshold parameter r. There is no formal proof for this property, yet it is generally accepted that it is true. Relative consistency in both Approximate Entropy and Sample entropy was first tested with the process. In the seminal paper by Richman and Moorman, it was shown that Approximate Entropy lacked the property for cases in which Sample Entropy did not. In the present paper, we show that relative consistency is not preserved for processes if enough noise is added, yet it is preserved for another process for which we define a sum of a sinusoidal and a stochastic element, no matter how much noise is present. The analysis presented in this paper is only possible because of the existence of the very fast NCM algorithm for calculating correlation sums and thus also Sample Entropy. - 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 203-204
Day-to-night variations of RR intervals complexity observed in 24-h ECG Holter R
Complexity of RR intervals can be measured by Sample entropy (SampEn) traditionally estimated only for a limited number of points by fixing the values of the embedding dimension "m" and distance threshold "r". Recently we have proposed a new and fast Norm Component Matrix (NCM) algorithm for SampEn calculation - it allows analyzing whole ranges of (m, r) values leading to entropy surfaces. This study is aimed at the analysis of these surfaces in the scope of day-to-night variations of RR intervals complexity estimated by the NCM.
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 203-204
Day-to-night variations of RR intervals complexity observed in 24-h ECG Holter R
Complexity of RR intervals can be measured by Sample entropy (SampEn) traditionally estimated only for a limited number of points by fixing the values of the embedding dimension "m" and distance threshold "r". Recently we have proposed a new and fast Norm Component Matrix (NCM) algorithm for SampEn calculation - it allows analyzing whole ranges of (m, r) values leading to entropy surfaces. This study is aimed at the analysis of these surfaces in the scope of day-to-night variations of RR intervals complexity estimated by the NCM.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2013 (1094687X) , 5053-5056
Assessing Sample Entropy of physiological signals by the norm component matrix algorithm: Application on muscular signals during isometric contraction
Sample Entropy (SampEn) is a popular method for assessing the unpredictability of biological signals. Its calculation requires to preliminarily set the tolerance threshold r and the embedding dimension m. Even if most studies select m=2 and r=0.2 times the signal standard deviation, this choice is somewhat arbitrary. Effects of different r and m values on SampEn have been rarely assessed, because of the high computational burden of this task. Recently, however, a fast algorithm for estimating correlation sums (Norm Component Matrix, NCM) has been proposed that allows calculating SampEn quickly over wide ranges of r and m. The aim of our work is to describe the structure of SampEn of physiological signals with different complex dynamics as a function of m and r and in relation to the correlation sum. In particular, we investigate whether the criterion of “maximum entropy” for selecting r previously proposed for Approximate Entropy, also applies to SampEn; and whether information from correlation sums provides indications for the choice of r and m. For this aim we applied the NCM algorithm on electromyographic and mechanomyographic signals during isometric muscle contraction, estimating SampEn over wide ranges of r (0.01≤ r ≤ 5) and m (from 1 to 11). Results indicate that the “maximum entropy” criterion to select r in Approximate Entropy cannot be applied to SampEn. However, the analysis of correlation sums alternatively suggests to choose r that at any m maximizes the number of “escaping vectors”, i.e., data points effectively contributing to the SampEn estimation.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2013 (1094687X) , 5053-5056
Assessing Sample Entropy of physiological signals by the norm component matrix algorithm: Application on muscular signals during isometric contraction
Sample Entropy (SampEn) is a popular method for assessing the unpredictability of biological signals. Its calculation requires to preliminarily set the tolerance threshold r and the embedding dimension m. Even if most studies select m=2 and r=0.2 times the signal standard deviation, this choice is somewhat arbitrary. Effects of different r and m values on SampEn have been rarely assessed, because of the high computational burden of this task. Recently, however, a fast algorithm for estimating correlation sums (Norm Component Matrix, NCM) has been proposed that allows calculating SampEn quickly over wide ranges of r and m. The aim of our work is to describe the structure of SampEn of physiological signals with different complex dynamics as a function of m and r and in relation to the correlation sum. In particular, we investigate whether the criterion of “maximum entropy” for selecting r previously proposed for Approximate Entropy, also applies to SampEn; and whether information from correlation sums provides indications for the choice of r and m. For this aim we applied the NCM algorithm on electromyographic and mechanomyographic signals during isometric muscle contraction, estimating SampEn over wide ranges of r (0.01≤ r ≤ 5) and m (from 1 to 11). Results indicate that the “maximum entropy” criterion to select r in Approximate Entropy cannot be applied to SampEn. However, the analysis of correlation sums alternatively suggests to choose r that at any m maximizes the number of “escaping vectors”, i.e., data points effectively contributing to the SampEn estimation.
- 1 December 2012
- Published by Elsevier in Physica A: Statistical Mechanics and its Applications
- Vol. 391 (24) , 6601-6610
On the relation between correlation dimension, approximate entropy and sample entropy parameters, and a fast algorithm for their calculation
- 1 December 2012
- Published by Elsevier in Physica A: Statistical Mechanics and its Applications
- Vol. 391 (24) , 6601-6610
On the relation between correlation dimension, approximate entropy and sample entropy parameters, and a fast algorithm for their calculation