Ji Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ji Fan has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Tao Liu
Key Laboratory of Intelligent Control and Optimization for Industrial Equipment of Ministry of Education, Dalian University of Technology
5 shared publications - Yonghong Tan
Shanghai Normal University
5 shared publications - YongCan Shuang
Institute of Advanced Control Technology, Dalian University of Technology, Dalian, China
4 shared publications - Junghui Chen
Department of Chemical Engineering, Chung-Yuan Christian University, Taoyuan, Taiwan
3 shared publications - Bo Song
Key Laboratory of Intelligent Control and Optimization for Industrial Equipment, Ministry of Education, and the School of Control Science & Engineering, Dalian University of Technology, Dalian, China
2 shared publications Xuejin Gao
2 shared publications
Latest Publications
- 31 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-19
In Situ Measurement of Rod-Like Crystal Size and Surface Area During Crystallization via Virtual Stereo Imaging
In this paper, a novel crystal size measurement method based on virtual stereo imaging is proposed for monitoring rod-like crystal growth in a glass crystallizer. A microscopic binocular vision system consisting of telecentric lenses with two different magnifications is designed to ensure the depth of field for capturing stereo images. The crystal image matching in each snapshot image pair is realized by developing an improved epipolar rectification strategy in combination with the Bézier curve fitting for extracting crystal feature contours, based on the YOLOv8 network for image segmentation. Subsequently, a virtual imaging plane is constructed based on the matched binocular crystal feature contour points to generate a virtual 2-D crystal image. Meanwhile, a criterion named overlapping ratio is introduced to evaluate the reconstruction accuracy. By projecting each crystal image from the camera imaging plane to the virtual imaging plane, the length and width of each crystal together with its surface area are measured by orthogonal decomposition projection. Experimental results on measuring the length, width, and surface area of β-form L-glutamic acid (LGA) crystals in a 1-L glass crystallizer well demonstrate the effectiveness and merits of the proposed measurement method.
- 31 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-19
In Situ Measurement of Rod-Like Crystal Size and Surface Area During Crystallization via Virtual Stereo Imaging
In this paper, a novel crystal size measurement method based on virtual stereo imaging is proposed for monitoring rod-like crystal growth in a glass crystallizer. A microscopic binocular vision system consisting of telecentric lenses with two different magnifications is designed to ensure the depth of field for capturing stereo images. The crystal image matching in each snapshot image pair is realized by developing an improved epipolar rectification strategy in combination with the Bézier curve fitting for extracting crystal feature contours, based on the YOLOv8 network for image segmentation. Subsequently, a virtual imaging plane is constructed based on the matched binocular crystal feature contour points to generate a virtual 2-D crystal image. Meanwhile, a criterion named overlapping ratio is introduced to evaluate the reconstruction accuracy. By projecting each crystal image from the camera imaging plane to the virtual imaging plane, the length and width of each crystal together with its surface area are measured by orthogonal decomposition projection. Experimental results on measuring the length, width, and surface area of β-form L-glutamic acid (LGA) crystals in a 1-L glass crystallizer well demonstrate the effectiveness and merits of the proposed measurement method.
- 24 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-14
Noninvasive Stereoscopic Backlight Imaging Design for In Situ Measurement of Particle Size Distribution During Continuous Crystallization via COBC
To realize in situ measurement of particle size distribution (PSD) during continuous crystallization via a continuous oscillatory baffled crystallizer (COBC), a novel noninvasive stereoscopic backlight imaging system is proposed in this paper together with a deep learning-based stereoscopic image analysis method. The stereoscopic imaging device consists of two telecentric lens-based cameras and backlight illuminators, while an optical platform is designed to acquire high-quality stereo images of flowing particles in the tubular crystallizer, which can be conveniently moved along the tubes of COBC for in situ measurement in different zones. By using a deep learning-based image segmentation network for processing the snapshotted image pairs, a matching algorithm is established to sort out the interest-point correspondences regarding particle length and width from each particle mask pair. Based on the matched interest-points, an optimal three-dimensional (3-D) point reconstruction method is presented to measure each particle size with regard to its 3-D posture in COBC. The designed stereoscopic backlight imaging system and 3-D reconstruction method are validated by inserting a microscale checkerboard into the COBC for in situ calibration and measurement. Experimental results on measuring PSD during the continuous crystallization process of β-type L-glutamic acid well demonstrate the effectiveness and merit of the proposed measurement method.
- 24 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-14
Noninvasive Stereoscopic Backlight Imaging Design for In Situ Measurement of Particle Size Distribution During Continuous Crystallization via COBC
To realize in situ measurement of particle size distribution (PSD) during continuous crystallization via a continuous oscillatory baffled crystallizer (COBC), a novel noninvasive stereoscopic backlight imaging system is proposed in this paper together with a deep learning-based stereoscopic image analysis method. The stereoscopic imaging device consists of two telecentric lens-based cameras and backlight illuminators, while an optical platform is designed to acquire high-quality stereo images of flowing particles in the tubular crystallizer, which can be conveniently moved along the tubes of COBC for in situ measurement in different zones. By using a deep learning-based image segmentation network for processing the snapshotted image pairs, a matching algorithm is established to sort out the interest-point correspondences regarding particle length and width from each particle mask pair. Based on the matched interest-points, an optimal three-dimensional (3-D) point reconstruction method is presented to measure each particle size with regard to its 3-D posture in COBC. The designed stereoscopic backlight imaging system and 3-D reconstruction method are validated by inserting a microscale checkerboard into the COBC for in situ calibration and measurement. Experimental results on measuring PSD during the continuous crystallization process of β-type L-glutamic acid well demonstrate the effectiveness and merit of the proposed measurement method.
- 30 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-15
In Situ Calibration of Binocular Vision System for 3-D Measurement of Particle Size During Crystallization
In this paper, a novel calibration method for setting up a binocular vision system is proposed to conduct in situ measurement of particle sizes during a crystallization process in a glass crystallizer. A backlit calibration pole consisting of light-emitting diodes (LEDs), a ceramic calibration board covered with a checkerboard pattern, a reflective prism, and an optical fiber is designed for in situ calibration of a binocular vision system composed of two telecentric cameras. Calibration of the stereo telecentric system can be simply accomplished by manually rotating the calibration board around its axis for in situ imaging. The imaging models of both telecentric cameras are established to precisely describe the relationship between a real point in three-dimensional (3-D) space in the crystallizer and the corresponding pixel points in both imaging planes, together with the error analysis on lens distortion. The optimal calibration model parameters are determined by the maximum likelihood estimation on the marked points of checkerboard pattern. Moreover, an epipolar rectification approach is provided to ensure precise matching of in situ snapshotted image pairs. Based on the matched image pairs, a 3-D reconstruction method with ray intersection is given to measure each particle size with respect to its 3-D posture in the crystallizer. Experimental results on in situ calibration and measuring the length and width of β-form L-glutamic acid crystals in a 1-L glass crystallizer well demonstrate the effectiveness and merits of the proposed calibration and measurement method.
- 30 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-15
In Situ Calibration of Binocular Vision System for 3-D Measurement of Particle Size During Crystallization
In this paper, a novel calibration method for setting up a binocular vision system is proposed to conduct in situ measurement of particle sizes during a crystallization process in a glass crystallizer. A backlit calibration pole consisting of light-emitting diodes (LEDs), a ceramic calibration board covered with a checkerboard pattern, a reflective prism, and an optical fiber is designed for in situ calibration of a binocular vision system composed of two telecentric cameras. Calibration of the stereo telecentric system can be simply accomplished by manually rotating the calibration board around its axis for in situ imaging. The imaging models of both telecentric cameras are established to precisely describe the relationship between a real point in three-dimensional (3-D) space in the crystallizer and the corresponding pixel points in both imaging planes, together with the error analysis on lens distortion. The optimal calibration model parameters are determined by the maximum likelihood estimation on the marked points of checkerboard pattern. Moreover, an epipolar rectification approach is provided to ensure precise matching of in situ snapshotted image pairs. Based on the matched image pairs, a 3-D reconstruction method with ray intersection is given to measure each particle size with respect to its 3-D posture in the crystallizer. Experimental results on in situ calibration and measuring the length and width of β-form L-glutamic acid crystals in a 1-L glass crystallizer well demonstrate the effectiveness and merits of the proposed calibration and measurement method.
- 6 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-14
Deep Learning-Based Binocular Image Analysis for In Situ Measurement of Particle Length Distribution During Crystallization Process
To resolve the challenge of measuring particle length distribution (PLD) during crystallization process via image analysis, a novel in situ measurement method with deep learning-based binocular image analysis is proposed in this paper. Firstly, a non-invasive binocular telecentric imaging scheme is designed for in situ measurement. Then a matching algorithm is presented to find the spatial correspondences between crystal images from a binocular image pair, by developing a telecentric stereo image rectification strategy together with a deep learning-based oriented object detection algorithm. Subsequently, the three-dimensional (3-D) space length of each identified crystal is reconstructed by integrating 2-D projected information from two matched crystal boxes in the binocular image pair, so as to acquire measurement accuracy on each crystal length. The proposed binocular imaging scheme and 3-D reconstruction method are validated by in situ measurement of a micro-checkerboard plate inserted into a cooling crystallizer. Experimental results on the cooling crystallization process of β-form L-glutamic acid demonstrate that the measurement accuracy on PLD is evidently improved with the mean absolute percentage errors smaller than 4.2%, compared to the recently developed methods.
- 6 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-14
Deep Learning-Based Binocular Image Analysis for In Situ Measurement of Particle Length Distribution During Crystallization Process
To resolve the challenge of measuring particle length distribution (PLD) during crystallization process via image analysis, a novel in situ measurement method with deep learning-based binocular image analysis is proposed in this paper. Firstly, a non-invasive binocular telecentric imaging scheme is designed for in situ measurement. Then a matching algorithm is presented to find the spatial correspondences between crystal images from a binocular image pair, by developing a telecentric stereo image rectification strategy together with a deep learning-based oriented object detection algorithm. Subsequently, the three-dimensional (3-D) space length of each identified crystal is reconstructed by integrating 2-D projected information from two matched crystal boxes in the binocular image pair, so as to acquire measurement accuracy on each crystal length. The proposed binocular imaging scheme and 3-D reconstruction method are validated by in situ measurement of a micro-checkerboard plate inserted into a cooling crystallizer. Experimental results on the cooling crystallization process of β-form L-glutamic acid demonstrate that the measurement accuracy on PLD is evidently improved with the mean absolute percentage errors smaller than 4.2%, compared to the recently developed methods.
- 17 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-15
In Situ Measurement of 2-D Crystal Size Distribution During Cooling Crystallization Process via a Binocular Telecentric Imaging System
In this paper, a novel in-situ measurement method with stereoscopic image analysis is proposed for monitoring crystal length and width distributions during a cooling crystallization process, based on a binocular telecentric imaging system. Firstly, a stereoscopic imaging calibration model is established for using binocular telecentric cameras to conduct in-situ measurement during a cooling crystallization process. Secondly, an enhanced algorithm is presented to improve matching crystal images from binocular image pairs, based on in-situ image preprocessing and segmentation. Thirdly, four key corners related to crystal length and width are determined by using the boundary features of matched crystal image projections. Finally, the length and width of each crystal are computed based on the reconstructed key corners in three-dimensional (3D) coordinate space, by using the established stereoscopic calibration model. Experimental validation on the proposed stereoscopic imaging calibration model and 3D reconstruction of key corners is carried out via in-situ measurement of a microscale checkerboard plate inserted into a cooling crystallizer. In-situ measurements of crystal length and width distributions during the cooling crystallization process of β-form L-glutamic acid are conducted to verify the effectiveness and advantage of the proposed measurement method.
- 17 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-15
In Situ Measurement of 2-D Crystal Size Distribution During Cooling Crystallization Process via a Binocular Telecentric Imaging System
In this paper, a novel in-situ measurement method with stereoscopic image analysis is proposed for monitoring crystal length and width distributions during a cooling crystallization process, based on a binocular telecentric imaging system. Firstly, a stereoscopic imaging calibration model is established for using binocular telecentric cameras to conduct in-situ measurement during a cooling crystallization process. Secondly, an enhanced algorithm is presented to improve matching crystal images from binocular image pairs, based on in-situ image preprocessing and segmentation. Thirdly, four key corners related to crystal length and width are determined by using the boundary features of matched crystal image projections. Finally, the length and width of each crystal are computed based on the reconstructed key corners in three-dimensional (3D) coordinate space, by using the established stereoscopic calibration model. Experimental validation on the proposed stereoscopic imaging calibration model and 3D reconstruction of key corners is carried out via in-situ measurement of a microscale checkerboard plate inserted into a cooling crystallizer. In-situ measurements of crystal length and width distributions during the cooling crystallization process of β-form L-glutamic acid are conducted to verify the effectiveness and advantage of the proposed measurement method.
- 10 May 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (7) , 075013
Application of an information fusion scheme for rolling element bearing fault diagnosis
This study addresses the high level of misdiagnoses and low reliability of individual rolling element bearing fault diagnosis methods by proposing a fault diagnosis scheme with enhanced diagnosis accuracy that combines the results of two individual diagnosis methods based on an improved information fusion method. The proposed scheme applies variational mode decomposition in conjunction with a support vector machine for conducting fault diagnosis in the frequency domain, which achieves high fault diagnosis precision for learned fault conditions. Meanwhile, good generalization ability is achieved for identifying the operational conditions of bearings in the time domain by integrated mathematical morphology and correlation analysis. Subsequently, conflicts arising between evidences derived from the individual detection results are measured comprehensively using a novel strategy, and the evidences are then combined based on the Dempster–Shafer theory (DST) to enhance the information fusion effect. The effectiveness of the proposed information fusion method is verified by means of a numerical example in comparison with other fusion methods based on DST. The experimental application of the proposed information fusion fault diagnosis scheme demonstrates the complementary advantages of the two individual methods for significantly improving the diagnosis accuracy relative to the accuracies of the individual methods alone.
- 10 May 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (7) , 075013
Application of an information fusion scheme for rolling element bearing fault diagnosis
This study addresses the high level of misdiagnoses and low reliability of individual rolling element bearing fault diagnosis methods by proposing a fault diagnosis scheme with enhanced diagnosis accuracy that combines the results of two individual diagnosis methods based on an improved information fusion method. The proposed scheme applies variational mode decomposition in conjunction with a support vector machine for conducting fault diagnosis in the frequency domain, which achieves high fault diagnosis precision for learned fault conditions. Meanwhile, good generalization ability is achieved for identifying the operational conditions of bearings in the time domain by integrated mathematical morphology and correlation analysis. Subsequently, conflicts arising between evidences derived from the individual detection results are measured comprehensively using a novel strategy, and the evidences are then combined based on the Dempster–Shafer theory (DST) to enhance the information fusion effect. The effectiveness of the proposed information fusion method is verified by means of a numerical example in comparison with other fusion methods based on DST. The experimental application of the proposed information fusion fault diagnosis scheme demonstrates the complementary advantages of the two individual methods for significantly improving the diagnosis accuracy relative to the accuracies of the individual methods alone.
- 29 June 2020
- Published by SAGE Publications in Journal of Vibration and Control
- Vol. 27 (11-12) , 1212-1230
Compound fault diagnosis of rolling element bearings using multipoint sparsity–multipoint optimal minimum entropy deconvolution adjustment and adaptive resonance-based signal sparse decomposition
The rolling element bearings used in rotating machinery generally include multiple coexisting defects. However, individual defect–induced signals of bearings simultaneously arising from multiple defects are difficult to extract from measured vibration signals because the impulse-like fault signals are very weak, and the vibration signal is commonly affected by the transmission path and various sources of interference. This issue is addressed in this study by proposing a new compound fault feature extraction scheme. Vibration signals are first preprocessed using resonance-based signal sparse decomposition to obtain the low-resonance component of the signal, which contains the information related to the transient fault–induced impulse signals, and reduce the interference of discrete harmonic signal components and noise. The objective used for adaptively selecting the optimal resonance-based signal sparse decomposition parameters adopts the ratio of permutation entropy to the frequency domain kurtosis, as a new comprehensive index, and the optimization is conducted using the cuckoo search algorithm. Subsequently, we apply multipoint sparsity to the low-resonance component to automatically determine the possible number of impulse signals and their periods according to the peak multipoint sparsity values. This enables the targeted extraction and isolation of fault-induced impulse signal features by multipoint optimal minimum entropy deconvolution adjustment. Finally, the envelope spectrum of the filtered signal is used to identify the individual faults. The effectiveness of the proposed scheme is verified by its application to both simulated and experimental compound bearing fault vibration signals with strong interference, and its advantages are confirmed by comparisons of the results with those of an existing state-of-the-art method.
- 29 June 2020
- Published by SAGE Publications in Journal of Vibration and Control
- Vol. 27 (11-12) , 1212-1230
Compound fault diagnosis of rolling element bearings using multipoint sparsity–multipoint optimal minimum entropy deconvolution adjustment and adaptive resonance-based signal sparse decomposition
The rolling element bearings used in rotating machinery generally include multiple coexisting defects. However, individual defect–induced signals of bearings simultaneously arising from multiple defects are difficult to extract from measured vibration signals because the impulse-like fault signals are very weak, and the vibration signal is commonly affected by the transmission path and various sources of interference. This issue is addressed in this study by proposing a new compound fault feature extraction scheme. Vibration signals are first preprocessed using resonance-based signal sparse decomposition to obtain the low-resonance component of the signal, which contains the information related to the transient fault–induced impulse signals, and reduce the interference of discrete harmonic signal components and noise. The objective used for adaptively selecting the optimal resonance-based signal sparse decomposition parameters adopts the ratio of permutation entropy to the frequency domain kurtosis, as a new comprehensive index, and the optimization is conducted using the cuckoo search algorithm. Subsequently, we apply multipoint sparsity to the low-resonance component to automatically determine the possible number of impulse signals and their periods according to the peak multipoint sparsity values. This enables the targeted extraction and isolation of fault-induced impulse signal features by multipoint optimal minimum entropy deconvolution adjustment. Finally, the envelope spectrum of the filtered signal is used to identify the individual faults. The effectiveness of the proposed scheme is verified by its application to both simulated and experimental compound bearing fault vibration signals with strong interference, and its advantages are confirmed by comparisons of the results with those of an existing state-of-the-art method.