Onur Açıkgöz
Research Subjects
Research Interests
Onur Açıkgöz has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Eymen Gazel
Acıbadem University Ankara Hospital, Department of Urology, Ankara, Turkey
5 shared publications - Halil Cagri Aybal
Kahramankazan Hamdi Eris State Hospital, Department of Urology, Ankara, Turkey
4 shared publications - Lutfi Tunc
Department of Urology, Gazi University School of Medicine, Ankara, Turkey
4 shared publications - Engin Kaya
Gulhane Training and Research Hospital, Turkey
3 shared publications - Mehmet Yilmaz
Urology, MediClin Kraichgau-Klinik, Bad Rappenau, Germany
3 shared publications - Sercan Yilmaz
Department of Urology, Gulhane Training and Research Hospital, Ankara, Turkey
3 shared publications
Latest Publications
- 28 June 2023
- Published by Elsevier in Transplantation Proceedings
- Vol. 55 (5) , 1116-1120
Standardization of Laparoscopic Donor Nephrectomy Technique in Minimizing Ureteral Complications in Renal Transplant Recipients: 10-Year Experience of a Single Center
- 28 June 2023
- Published by Elsevier in Transplantation Proceedings
- Vol. 55 (5) , 1116-1120
Standardization of Laparoscopic Donor Nephrectomy Technique in Minimizing Ureteral Complications in Renal Transplant Recipients: 10-Year Experience of a Single Center
- 5 June 2023
- Published by Galenos Yayinevi in Journal of Urological Surgery
- Vol. 10 (2) , 101-106
Safety and Efficacy of Holmium Laser Enucleation of the Prostate (HoLEP) in Patients Requiring Anticoagulants/Antiplatelets: A Retrospective Study
- 5 June 2023
- Published by Galenos Yayinevi in Journal of Urological Surgery
- Vol. 10 (2) , 101-106
Safety and Efficacy of Holmium Laser Enucleation of the Prostate (HoLEP) in Patients Requiring Anticoagulants/Antiplatelets: A Retrospective Study
- 5 June 2023
- Published by Galenos Yayinevi in Journal of Urological Surgery
- Vol. 10 (2) , 85-92
The Effect of the MAYO Adhesive Probability Score on Intraoperative Parameters in Laparoscopic Live Donor Nephrectomy and Bench Surgery
- 5 June 2023
- Published by Galenos Yayinevi in Journal of Urological Surgery
- Vol. 10 (2) , 85-92
The Effect of the MAYO Adhesive Probability Score on Intraoperative Parameters in Laparoscopic Live Donor Nephrectomy and Bench Surgery
- 30 April 2023
- Published by Elsevier in Transplantation Proceedings
- Vol. 55 (5) , 1125-1128
Comparison of Bipolar Electrocautery-Based Vascular Sealers with Conventional Ligation in Iliac Vessel Preparation of Renal Transplant Recipients
- 30 April 2023
- Published by Elsevier in Transplantation Proceedings
- Vol. 55 (5) , 1125-1128
Comparison of Bipolar Electrocautery-Based Vascular Sealers with Conventional Ligation in Iliac Vessel Preparation of Renal Transplant Recipients
- 27 February 2023
- Published by Pera Yayıncılık Hizmetleri in Yeni Üroloji Dergisi
- Vol. 18 (1) , 100-107
Demographic characteristics of Turkish kidney donors and the impact of donor-recipient relationship on postoperative outcomes: A single-center experience
Objective: Kidney transplantation (KTx) is the most effective treatment option for patients with end-stage renal disease (ESRD). Live donor kidney transplantation is unique as it involves healthy individuals who undergo a major surgery. This retrospective study seeks to investigate the effect of donor–recipient relationship on postoperative outcomes in Turkish donors undergoing laparoscopic donor nephrectomy (DNx). Material and Methods: The study was conducted with a total of 297 patients who underwent left DNx. The patients included in the study were divided into six different groups based on the degree of relationship with the recipients: Sixty-nine cases of DNx involved mothers as kidney donors classified into group-1, 29 cases involving fathers into group-2, 70 cases involving spouses into group-3, 68 cases involving siblings into group-4, 31 cases involving children into group-5, and 30 cases involving second-degree and more distant relatives into group-6. Patients’ data including age, sex, education level, duration of surgery (ST), Visual Analog Scale (VAS) pain score at postoperative day 1, length of hospital stay (HS), and Quality of Life (QoL) were retrospectively analyzed and recorded. Results: The groups had significant differences in terms of VAS scores, HS, and QoL-MS. Posthoc analysis was performed to find out which groups had significant differences. Results showed that group-1 had significantly lower VAS scores than group-2, group-3, and group-6. HS was significantly long in group-3 and group-6. QoL-MSwas significantly lower in group-2 and group-6 than the other groups. Conclusion: The degree of relationship of living kidney donors to recipients influences their psychological health in the early postoperative period and probably affects VAS scores and length of hospital stay. It can be argued that mothers are the group of donors least affected by the kidney donation process. Keywords: kidney; transplantation; live donor; donor-recipient relationship
- 27 February 2023
- Published by Pera Yayıncılık Hizmetleri in Yeni Üroloji Dergisi
- Vol. 18 (1) , 100-107
Demographic characteristics of Turkish kidney donors and the impact of donor-recipient relationship on postoperative outcomes: A single-center experience
Objective: Kidney transplantation (KTx) is the most effective treatment option for patients with end-stage renal disease (ESRD). Live donor kidney transplantation is unique as it involves healthy individuals who undergo a major surgery. This retrospective study seeks to investigate the effect of donor–recipient relationship on postoperative outcomes in Turkish donors undergoing laparoscopic donor nephrectomy (DNx). Material and Methods: The study was conducted with a total of 297 patients who underwent left DNx. The patients included in the study were divided into six different groups based on the degree of relationship with the recipients: Sixty-nine cases of DNx involved mothers as kidney donors classified into group-1, 29 cases involving fathers into group-2, 70 cases involving spouses into group-3, 68 cases involving siblings into group-4, 31 cases involving children into group-5, and 30 cases involving second-degree and more distant relatives into group-6. Patients’ data including age, sex, education level, duration of surgery (ST), Visual Analog Scale (VAS) pain score at postoperative day 1, length of hospital stay (HS), and Quality of Life (QoL) were retrospectively analyzed and recorded. Results: The groups had significant differences in terms of VAS scores, HS, and QoL-MS. Posthoc analysis was performed to find out which groups had significant differences. Results showed that group-1 had significantly lower VAS scores than group-2, group-3, and group-6. HS was significantly long in group-3 and group-6. QoL-MSwas significantly lower in group-2 and group-6 than the other groups. Conclusion: The degree of relationship of living kidney donors to recipients influences their psychological health in the early postoperative period and probably affects VAS scores and length of hospital stay. It can be argued that mothers are the group of donors least affected by the kidney donation process. Keywords: kidney; transplantation; live donor; donor-recipient relationship
- Open Access
- 25 February 2023
- Published by Springer Nature in Cureus
- Vol. 15 (2) , e35438
The Predictive Value of Donor Renal Functions, Graft Weight, Recipient Body Mass Index, and Human Leucocyte Antigen Match Regarding Early Graft Functions
Background and objective Graft performance is the most important postoperative parameter for patients undergoing kidney transplantation (KTx). The renal function of the donor is reported to be correlated with graft function after KTx. The body mass index (BMI) is also one of the important parameters involved in the prediction of graft function. The aim of this retrospective study was to examine the relationship between early postoperative graft function in patients undergoing KTx and donor cystatin C and estimated glomerular filtration rate (e-GFR) levels, graft weight/recipient BMI (G/B) ratio, and human leukocyte antigen (HLA) tissue compatibility. Materials and methods A total of 215 cases (215 donors, 215 recipients) who underwent KTx at our center between January 2018 and December 2022 were included in the study. Patients' age, sex, BMI, preoperative donor serum cystatin C and e-GFR levels, HLA tissue compatibility, graft weights, and recipient creatinine levels were recorded one week postoperatively. The Kolmogorov-Smirnov test and histogram plots were used to analyze the conformity of the variables to the normal distribution and Spearman's correlation test was used to analyze the relationship between variables. Results A negative correlation was identified between recipient creatinine level and G/B ratio and donor e-GFR (r = −0.256 and −0.137, respectively). Donor cystatin C level showed a positive correlation with recipient creatinine level (r = 0.242). No significant correlation was noted in terms of tissue matching rates (p = 0.616). Conclusion Although these three parameters are correlated with early graft functions, the graft weight/recipient BMI ratio has the strongest correlation.
- 25 February 2023
- Published by Springer Nature in Cureus
- Vol. 15 (2) , e35438
Open AccessThe Predictive Value of Donor Renal Functions, Graft Weight, Recipient Body Mass Index, and Human Leucocyte Antigen Match Regarding Early Graft Functions
Background and objective Graft performance is the most important postoperative parameter for patients undergoing kidney transplantation (KTx). The renal function of the donor is reported to be correlated with graft function after KTx. The body mass index (BMI) is also one of the important parameters involved in the prediction of graft function. The aim of this retrospective study was to examine the relationship between early postoperative graft function in patients undergoing KTx and donor cystatin C and estimated glomerular filtration rate (e-GFR) levels, graft weight/recipient BMI (G/B) ratio, and human leukocyte antigen (HLA) tissue compatibility. Materials and methods A total of 215 cases (215 donors, 215 recipients) who underwent KTx at our center between January 2018 and December 2022 were included in the study. Patients' age, sex, BMI, preoperative donor serum cystatin C and e-GFR levels, HLA tissue compatibility, graft weights, and recipient creatinine levels were recorded one week postoperatively. The Kolmogorov-Smirnov test and histogram plots were used to analyze the conformity of the variables to the normal distribution and Spearman's correlation test was used to analyze the relationship between variables. Results A negative correlation was identified between recipient creatinine level and G/B ratio and donor e-GFR (r = −0.256 and −0.137, respectively). Donor cystatin C level showed a positive correlation with recipient creatinine level (r = 0.242). No significant correlation was noted in terms of tissue matching rates (p = 0.616). Conclusion Although these three parameters are correlated with early graft functions, the graft weight/recipient BMI ratio has the strongest correlation.
- 21 February 2022
- Published by Pera Yayıncılık Hizmetleri in Yeni Üroloji Dergisi
- Vol. 17 (1) , 6-13
Hawk® JAWS versus Lumenis® VersaCut prostate morcellation devices: A comparative study and comprehensive literature review
Objective: Although morcellation is a standard procedure of Holmium Laser Enucleation of the Prostate (HoLEP), studies on the morcellators used are limited in number. We aimed to compare two different tissue morcellators used in HoLEP, which have similar objectives but differences in efficiency and safety in working principles. Material and Methods: The data of 130 patients who underwent HoLEP between December 2018 and December 2019 were retrospectively reviewed. Sixty-five patients received Lumenis® Versacut (Lumenis Inc., Santa Clara, CA, USA) morcellator and 65 patients received Hawk® JAWS (Hawk, Minitech Co., China) morcellator after enucleation were included in the study. The efficiency of morcellation (g/min), morcellation time (min), total operation time (min), enucleation time (min), enucleated tissue weight (g), the efficiency of enucleation, densities of the removed prostate tissues, perioperative complications associated with the use of a morcellator were recorded perioperatively. Results: There was no significant difference in total operation time (min), enucleation time (min), enucleated tissue weight (g), and efficiency of enucleation (g/min) efficiency of morcellation, morcellation time (min) between the two groups. Bladder mucosal damage occurred in 3 patients (4%) in the Versacut group, while mucosal bladder damage was not observed in any patient in the Hawk® JAWS group (p = 0.08). Conclusion: Hawk® JAWS and Lumenis® VersaCut morcellators were comparable in their efficiency and safety. Keywords: Hawk, HoLEP, morcellation, morcellator, Versacut.
- 21 February 2022
- Published by Pera Yayıncılık Hizmetleri in Yeni Üroloji Dergisi
- Vol. 17 (1) , 6-13
Hawk® JAWS versus Lumenis® VersaCut prostate morcellation devices: A comparative study and comprehensive literature review
Objective: Although morcellation is a standard procedure of Holmium Laser Enucleation of the Prostate (HoLEP), studies on the morcellators used are limited in number. We aimed to compare two different tissue morcellators used in HoLEP, which have similar objectives but differences in efficiency and safety in working principles. Material and Methods: The data of 130 patients who underwent HoLEP between December 2018 and December 2019 were retrospectively reviewed. Sixty-five patients received Lumenis® Versacut (Lumenis Inc., Santa Clara, CA, USA) morcellator and 65 patients received Hawk® JAWS (Hawk, Minitech Co., China) morcellator after enucleation were included in the study. The efficiency of morcellation (g/min), morcellation time (min), total operation time (min), enucleation time (min), enucleated tissue weight (g), the efficiency of enucleation, densities of the removed prostate tissues, perioperative complications associated with the use of a morcellator were recorded perioperatively. Results: There was no significant difference in total operation time (min), enucleation time (min), enucleated tissue weight (g), and efficiency of enucleation (g/min) efficiency of morcellation, morcellation time (min) between the two groups. Bladder mucosal damage occurred in 3 patients (4%) in the Versacut group, while mucosal bladder damage was not observed in any patient in the Hawk® JAWS group (p = 0.08). Conclusion: Hawk® JAWS and Lumenis® VersaCut morcellators were comparable in their efficiency and safety. Keywords: Hawk, HoLEP, morcellation, morcellator, Versacut.
- 31 May 2021
- Published by Hindawi Limited in Andrologia
- Vol. 53 (8) , e14137
Is ‘Omega Sign’ anatomical endoscopic enucleation of the prostate technique reproducible?
We aimed to evaluate the learning curve of the surgically standardised ‘Omega Sign’ anatomical endoscopic enucleation (AEEP) of the prostate surgery technique for junior surgeons. This study is a retrospective comparison of cases that underwent AEEP by a mentor surgeon and three junior surgeons who have completed their learning curve. A video-based laser enucleation of the prostate assessment tool (LEAT) composed of 8 steps of the technique was used to assess a senior surgeon and junior surgeons’ surgical compatibility and consistency. The surgeon who defined Omega Sign technique was determined as group 1, and cases by three junior surgeons were identified as group 2. The end points were to assess the reproducibility and repeatability and operative post-operative outcomes of the technique. 55 patients’ videos were rated by five experienced endourologists. There was no significant difference in LEAT scores between the groups among all steps. The most symmetry was found in the 1st and 3rd steps. Inter-rater consistency was also high for each step, with no statistically significant difference between the evaluators. The standardised anatomical ‘Omega Sign’ technique is reproducible for the junior surgeons. The operative steps can be performed with high consistency, and the functional and perioperative outcomes are comparable with the senior surgeon.
- 31 May 2021
- Published by Hindawi Limited in Andrologia
- Vol. 53 (8) , e14137
Is ‘Omega Sign’ anatomical endoscopic enucleation of the prostate technique reproducible?
We aimed to evaluate the learning curve of the surgically standardised ‘Omega Sign’ anatomical endoscopic enucleation (AEEP) of the prostate surgery technique for junior surgeons. This study is a retrospective comparison of cases that underwent AEEP by a mentor surgeon and three junior surgeons who have completed their learning curve. A video-based laser enucleation of the prostate assessment tool (LEAT) composed of 8 steps of the technique was used to assess a senior surgeon and junior surgeons’ surgical compatibility and consistency. The surgeon who defined Omega Sign technique was determined as group 1, and cases by three junior surgeons were identified as group 2. The end points were to assess the reproducibility and repeatability and operative post-operative outcomes of the technique. 55 patients’ videos were rated by five experienced endourologists. There was no significant difference in LEAT scores between the groups among all steps. The most symmetry was found in the 1st and 3rd steps. Inter-rater consistency was also high for each step, with no statistically significant difference between the evaluators. The standardised anatomical ‘Omega Sign’ technique is reproducible for the junior surgeons. The operative steps can be performed with high consistency, and the functional and perioperative outcomes are comparable with the senior surgeon.
- 13 November 2020
- Published by Springer Nature in World Journal of Urology
- Vol. 39 (7) , 2605-2611
HoLEP after prostate biopsy: does it have any impact?
Purpose Holmium laser enucleation of the prostate (HoLEP) has recently become the recommended treatment for prostate in all sizes in benign prostate hyperplasia surgery. A recent prostate biopsy performed prior to the HoLEP procedure can make surgeons concerned about the surgery. We aimed to investigate the per- and postoperative outcomes of the HoLEP procedure in patients who underwent prostate biopsy and to evaluate the most appropriate surgery time after biopsy. Methods The data of 160 patients who underwent HoLEP by a single surgeon between March 2017 and December 2019 were retrospectively reviewed. The patients were divided into two groups, Group 1 consisted of 80 patients without prostate biopsy and Group 2 consisted of 80 patients with prior prostate biopsy. All HOLEP procedures in group 2 were performed at least 2 weeks following biopsy. Per- and postoperative outcomes, complications were evaluated. Results No significant differences were found between groups in terms of by enucleation time, efficiency of laser, efficiency of enucleation, hospitalization time, and catheterization removal time. Only morcellation time was shorter in biopsy naïve patients. There were no statistical differences in postoperative outcomes. Previous prostate biopsy did not affect the continence status in our study group. There were not any Clavien grade 4 or higher complications. Urinary tract infection was higher in early post-biopsy period, there was no difference among the groups. Conclusıon Our study confirms that HoLEP is a safe and efficient surgical procedure for the patients with prior prostate biopsy. We believe that it can be safely performed 2nd week following prostate biopsy.
- 13 November 2020
- Published by Springer Nature in World Journal of Urology
- Vol. 39 (7) , 2605-2611
HoLEP after prostate biopsy: does it have any impact?
Purpose Holmium laser enucleation of the prostate (HoLEP) has recently become the recommended treatment for prostate in all sizes in benign prostate hyperplasia surgery. A recent prostate biopsy performed prior to the HoLEP procedure can make surgeons concerned about the surgery. We aimed to investigate the per- and postoperative outcomes of the HoLEP procedure in patients who underwent prostate biopsy and to evaluate the most appropriate surgery time after biopsy. Methods The data of 160 patients who underwent HoLEP by a single surgeon between March 2017 and December 2019 were retrospectively reviewed. The patients were divided into two groups, Group 1 consisted of 80 patients without prostate biopsy and Group 2 consisted of 80 patients with prior prostate biopsy. All HOLEP procedures in group 2 were performed at least 2 weeks following biopsy. Per- and postoperative outcomes, complications were evaluated. Results No significant differences were found between groups in terms of by enucleation time, efficiency of laser, efficiency of enucleation, hospitalization time, and catheterization removal time. Only morcellation time was shorter in biopsy naïve patients. There were no statistical differences in postoperative outcomes. Previous prostate biopsy did not affect the continence status in our study group. There were not any Clavien grade 4 or higher complications. Urinary tract infection was higher in early post-biopsy period, there was no difference among the groups. Conclusıon Our study confirms that HoLEP is a safe and efficient surgical procedure for the patients with prior prostate biopsy. We believe that it can be safely performed 2nd week following prostate biopsy.
- Open Access
- 1 January 2020
- Published by Kare Publishing in Northern Clinics of Istanbul
- Vol. 8 (1) , 57-62
The effect of bladder neck sparing with additional anterior urethral fixation on postoperative continence after robot-assisted radical prostatectomy
OBJECTIVE: Urinary incontinence remains one of the main problems affecting the quality of life after radical prostatectomy. Along with the improved understanding of the precise anatomy of the prostate, urethra and their surrounding structures, minimally invasive surgical techniques have been refined and described, aiming to improve functional outcomes without oncological compromise. This study aimed to investigate the impacts of anterior urethral fixation (AUF) and bladder neck sparing (BNS) on the early continence success after Robot-assisted Radical Prostatectomy (RALP). METHODS: This retrospective study included 120 patients who underwent RALP between January 2018 and June 2019. Patients were allocated to one of two groups; group 1 (n=60) underwent RALP with BNS, group 2 (n=60) underwent RALP with both AUF and BNS. The patient continence status was measured at baseline on day 7 and in the 1st, 3rd, and 6th months postoperatively. RESULTS: Concerning Incontinence Impact Questionnaire-7 form, statistically significant better results in group 2 were recorded in all visits, but the last (month 6) (p=0.023). Following catheter removal, postmicturition symptoms, including incomplete emptying and post-micturition dribble rate, were significantly higher in group 1 after catheter removal and in the 1st month (13.3% vs. 0 p=0.006). This difference was not recorded at the next visits (months 3 and 6). CONCLUSION: Our findings showed that the combination of AUF and BNS significantly increases early continence rates and decreases post-mictional symptoms after RALP without hampering oncologic outcomes.
- 1 January 2020
- Published by Kare Publishing in Northern Clinics of Istanbul
- Vol. 8 (1) , 57-62
Open AccessThe effect of bladder neck sparing with additional anterior urethral fixation on postoperative continence after robot-assisted radical prostatectomy
OBJECTIVE: Urinary incontinence remains one of the main problems affecting the quality of life after radical prostatectomy. Along with the improved understanding of the precise anatomy of the prostate, urethra and their surrounding structures, minimally invasive surgical techniques have been refined and described, aiming to improve functional outcomes without oncological compromise. This study aimed to investigate the impacts of anterior urethral fixation (AUF) and bladder neck sparing (BNS) on the early continence success after Robot-assisted Radical Prostatectomy (RALP). METHODS: This retrospective study included 120 patients who underwent RALP between January 2018 and June 2019. Patients were allocated to one of two groups; group 1 (n=60) underwent RALP with BNS, group 2 (n=60) underwent RALP with both AUF and BNS. The patient continence status was measured at baseline on day 7 and in the 1st, 3rd, and 6th months postoperatively. RESULTS: Concerning Incontinence Impact Questionnaire-7 form, statistically significant better results in group 2 were recorded in all visits, but the last (month 6) (p=0.023). Following catheter removal, postmicturition symptoms, including incomplete emptying and post-micturition dribble rate, were significantly higher in group 1 after catheter removal and in the 1st month (13.3% vs. 0 p=0.006). This difference was not recorded at the next visits (months 3 and 6). CONCLUSION: Our findings showed that the combination of AUF and BNS significantly increases early continence rates and decreases post-mictional symptoms after RALP without hampering oncologic outcomes.