Nicholas Etherden
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nicholas Etherden has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Math. H. J. Bollen
Department of Engineering Sciences and Mathematics, Luleå University of Technology, 97187 Skellefteå, Sweden
6 shared publications - Enock Mulenga
Electric Power Engineering, Luleå University of Technology, Forskargatan 1, SE-931 87 Skellefteå, Sweden
4 shared publications - Taís Tavares de Oliveira
Electric Power Engineering Luleå University of Technology Skellefteå Sweden
2 shared publications Math H. J. Bollen
Department of Engineering Sciences and Mathematics, Luleå University of Technology, Lulea, Sweden
1 shared publicationMouaz Alhamwi
Vattenfall R&D 169 92 Stockholm Sweden
1 shared publicationValeriy Vyatkin
Department of Computer Science, Electrical, and Space Engineering, Luleå University of Technology, Luleå, Sweden
1 shared publication
Latest Publications
- Open Access
- 3 December 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 253
Impact of MV reserve path operation on LV network hosting capacity
- 3 December 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 253
Open AccessImpact of MV reserve path operation on LV network hosting capacity
- Open Access
- 5 October 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 238
A hosting capacity based approach toward distribution system planning for high PV penetration
- 5 October 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 238
Open AccessA hosting capacity based approach toward distribution system planning for high PV penetration
Using Online Solar Photovoltaics Inverter Measurements to Determine the Hosting Capacity of Distribution Grids
The amount of solar photovoltaics (PV) that can be connected to the grid is a question which, especially for distributed solar, is characterized by a strong information unbalance between, on the one side, the grid operators and on the other side those wanting to feed in electricity. Herein, how the grid impact of PV can be assessed by analyzing inverter voltage measurements that today are available from millions of online PV inverters is demonstrated. In the case where grid capacity is limited by voltage, online PV inverters are shown to provide a valuable complement to distribution system operators estimation of grid capacity. Using 25 million voltage samples from a thousand PV systems, a hosting capacity map is produced for 20 of 21 regions of Sweden. The map shows the amount of PV that typically can be installed without causing voltage rise that would lead to inverter cutoff and loss of production. By monitoring and following the voltage impact from solar PV over time, local saturation effects can be detected and the timing of grid investments better planned. The information could also enhance regulators in their role to monitor grid operators and assure the right level of grid investments.
Using Online Solar Photovoltaics Inverter Measurements to Determine the Hosting Capacity of Distribution Grids
The amount of solar photovoltaics (PV) that can be connected to the grid is a question which, especially for distributed solar, is characterized by a strong information unbalance between, on the one side, the grid operators and on the other side those wanting to feed in electricity. Herein, how the grid impact of PV can be assessed by analyzing inverter voltage measurements that today are available from millions of online PV inverters is demonstrated. In the case where grid capacity is limited by voltage, online PV inverters are shown to provide a valuable complement to distribution system operators estimation of grid capacity. Using 25 million voltage samples from a thousand PV systems, a hosting capacity map is produced for 20 of 21 regions of Sweden. The map shows the amount of PV that typically can be installed without causing voltage rise that would lead to inverter cutoff and loss of production. By monitoring and following the voltage impact from solar PV over time, local saturation effects can be detected and the timing of grid investments better planned. The information could also enhance regulators in their role to monitor grid operators and assure the right level of grid investments.
- Open Access
- 16 September 2023
- Published by Elsevier in Sustainable Energy, Grids and Networks
- Vol. 36
Multiple distribution networks hosting capacity assessment using a stochastic approach
- 16 September 2023
- Published by Elsevier in Sustainable Energy, Grids and Networks
- Vol. 36
Open AccessMultiple distribution networks hosting capacity assessment using a stochastic approach
- Open Access
- 30 March 2022
- Published by Elsevier in Electric Power Systems Research
- Vol. 209
Limits set by component loadability on solar power integration in distribution networks
- 30 March 2022
- Published by Elsevier in Electric Power Systems Research
- Vol. 209
Open AccessLimits set by component loadability on solar power integration in distribution networks
- Open Access
- 17 September 2021
- Published by MDPI AG in Electricity
- Vol. 2 (3) , 387-402
Adapted Stochastic PV Hosting Capacity Approach for Electric Vehicle Charging Considering Undervoltage
This paper presents a stochastic approach to single-phase and three-phase EV charge hosting capacity for distribution networks. The method includes the two types of uncertainties, aleatory and epistemic, and is developed from an equivalent method that was applied to solar PV hosting capacity estimation. The method is applied to two existing low-voltage networks in Northern Sweden, with six and 83 customers. The lowest background voltage and highest consumption per customer are obtained from measurements. It is shown that both have a big impact on the hosting capacity. The hosting capacity also depends strongly on the charging size, within the range of charging size expected in the near future. The large range in hosting capacity found from this study—between 0% and 100% of customers can simultaneously charge their EV car—means that such hosting capacity studies are needed for each individual distribution network. The highest hosting capacity for the illustrative distribution networks was obtained for the 3.7 kW single-phase and 11 kW three-phase EV charging power.
- 17 September 2021
- Published by MDPI AG in Electricity
- Vol. 2 (3) , 387-402
Open AccessAdapted Stochastic PV Hosting Capacity Approach for Electric Vehicle Charging Considering Undervoltage
This paper presents a stochastic approach to single-phase and three-phase EV charge hosting capacity for distribution networks. The method includes the two types of uncertainties, aleatory and epistemic, and is developed from an equivalent method that was applied to solar PV hosting capacity estimation. The method is applied to two existing low-voltage networks in Northern Sweden, with six and 83 customers. The lowest background voltage and highest consumption per customer are obtained from measurements. It is shown that both have a big impact on the hosting capacity. The hosting capacity also depends strongly on the charging size, within the range of charging size expected in the near future. The large range in hosting capacity found from this study—between 0% and 100% of customers can simultaneously charge their EV car—means that such hosting capacity studies are needed for each individual distribution network. The highest hosting capacity for the illustrative distribution networks was obtained for the 3.7 kW single-phase and 11 kW three-phase EV charging power.
- Open Access
- 1 March 2021
- Published by Elsevier in Electric Power Systems Research
- Vol. 192
Distribution networks measured background voltage variations, probability distributions characterization and Solar PV hosting capacity estimations
- 1 March 2021
- Published by Elsevier in Electric Power Systems Research
- Vol. 192
Open AccessDistribution networks measured background voltage variations, probability distributions characterization and Solar PV hosting capacity estimations
- 18 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 12 (1) , 437-447
Virtual Power Plant for Grid Services Using IEC 61850
This paper assesses the communication, information, and functional requirements of virtual power plants (VPPs). A conceptual formulation of the interoperability requirements, as well as a comparative study of their fulfillment by state-of-the-art communication techniques, is presented. VPP requirements are then mapped against services and information models of IEC 61850 and common information model (CIM) power utility automation standards. Proposals are given for extensions of the IEC 61850 standard to enhance the interaction between the VPP controller and the distributed energy resources. Finally, the methodology and concepts are applied to a specific VPP consisting of hydro and wind plants, solar photovoltaic (PV) power, and storage facilities. Several applications to provide grid services from the proposed VPP in an existing 50-kV grid are covered. The implementation of the VPP communication and control architecture in the supervisory control and data acquisition (SCADA) of demonstration plant is also presented.
- 18 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 12 (1) , 437-447
Virtual Power Plant for Grid Services Using IEC 61850
This paper assesses the communication, information, and functional requirements of virtual power plants (VPPs). A conceptual formulation of the interoperability requirements, as well as a comparative study of their fulfillment by state-of-the-art communication techniques, is presented. VPP requirements are then mapped against services and information models of IEC 61850 and common information model (CIM) power utility automation standards. Proposals are given for extensions of the IEC 61850 standard to enhance the interaction between the VPP controller and the distributed energy resources. Finally, the methodology and concepts are applied to a specific VPP consisting of hydro and wind plants, solar photovoltaic (PV) power, and storage facilities. Several applications to provide grid services from the proposed VPP in an existing 50-kV grid are covered. The implementation of the VPP communication and control architecture in the supervisory control and data acquisition (SCADA) of demonstration plant is also presented.
- 1 September 2014
- Published by Elsevier in Electric Power Systems Research
- Vol. 114, 39-48
Overload and overvoltage in low-voltage and medium-voltage networks due to renewable energy – some illustrative case studies
- 1 September 2014
- Published by Elsevier in Electric Power Systems Research
- Vol. 114, 39-48
Overload and overvoltage in low-voltage and medium-voltage networks due to renewable energy – some illustrative case studies