Paul Nahas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paul Nahas has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Samir Nammour
Department of Dental Sciences, Faculty of Medicine, University of Liège, Belgium
2 shared publications - Toni Zeinoun
Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine, Lebanese University, Beirut 27798, Lebanon
2 shared publications - Daniel Heysselaer
Department of Dental Science, Faculty of Medicine, University of Liege, 4000 Liege, Belgium
1 shared publication - Elie Gerges
Department of Prosthodontics, Faculty of Dental Medicine, Lebanese University, Beirut 27798, Lebanon
1 shared publication - Jean Claude Fahed
Lebanese University
1 shared publication - Joseph Sabbagh
Lebanese University
1 shared publication
Latest Publications
- Open Access
- 27 April 2023
- Published by MDPI AG in Dentistry Journal
- Vol. 11 (5) , 116
Assessment of the Periodontal Cementum Ablation Depth during Root Planing by an Er:YAG Laser at Different Energy Densities: An Ex Vivo Study
Introduction: An important and non-adapted delivered energy of Er:YAG laser can eliminate the total thickness of root cementum during root planing. Conversely, the preservation of a partial layer of cementum covering the roots is vital for any periodontal ligament regeneration. Thus, the assessment of the cementum ablation depth produced by each energy density of Er:YAG laser is essential before considering its use for the periodontal planing and treatment of the cementum and root surfaces. Aim of the study: Assessment of the cementum ablation depth at different energy densities of the Er:YAG laser is the aim of this study. Materials and methods: A total of 48 human caries free molars were collected and used in this study. Areas to be irradiated were delimited by two longitudinal grooves (0.5 mm depth). Roots were divided randomly into four groups (4 × n = 12). An Er:YAG laser (2.94 µm) was used with a side-firing tip (R600T) with a 600 µm diameter and a frequency of 20 Hz combined with a cooling system of air 6 mL/min and water 4 mL/min. We used a super short pulse mode (SSP: pulse duration: 50 μs). We used a single irradiation passage backward from apex to cervical parts at 1 mm/s with a slight contact and at an angle of 15° to 30° between the tip and the root surface. Different energies were selected: 30 mJ, 40 mJ, 50 mJ, and 60 mJ. Results: Microscopic observations showed that the average of the ablation depth increased with the increase of the delivered energy from 30 mJ to 60 mJ. Mean values of the ablation depths were respectively as follows: 43.75 ± 4.89 µm for the energy of 30 mJ, 50.05 ± 3.72 µm for 40 mJ, 65.56 ± 10.35 µm for 50 mJ, and 74.80 ± 15.23 µm for 60 mJ. A statistically significant difference existed between the ablation depth of all groups. Conclusion: Based on our results, the depth of cementum debridement is related to the level of the delivered energy. The lowest energy levels (30 mJ and 40 mJ) can ablate the root cementum surface for a variable depth from 43.75 ± 4.89 μm to 50.05 ± 3.72 μm.
- 27 April 2023
- Published by MDPI AG in Dentistry Journal
- Vol. 11 (5) , 116
Open AccessAssessment of the Periodontal Cementum Ablation Depth during Root Planing by an Er:YAG Laser at Different Energy Densities: An Ex Vivo Study
Introduction: An important and non-adapted delivered energy of Er:YAG laser can eliminate the total thickness of root cementum during root planing. Conversely, the preservation of a partial layer of cementum covering the roots is vital for any periodontal ligament regeneration. Thus, the assessment of the cementum ablation depth produced by each energy density of Er:YAG laser is essential before considering its use for the periodontal planing and treatment of the cementum and root surfaces. Aim of the study: Assessment of the cementum ablation depth at different energy densities of the Er:YAG laser is the aim of this study. Materials and methods: A total of 48 human caries free molars were collected and used in this study. Areas to be irradiated were delimited by two longitudinal grooves (0.5 mm depth). Roots were divided randomly into four groups (4 × n = 12). An Er:YAG laser (2.94 µm) was used with a side-firing tip (R600T) with a 600 µm diameter and a frequency of 20 Hz combined with a cooling system of air 6 mL/min and water 4 mL/min. We used a super short pulse mode (SSP: pulse duration: 50 μs). We used a single irradiation passage backward from apex to cervical parts at 1 mm/s with a slight contact and at an angle of 15° to 30° between the tip and the root surface. Different energies were selected: 30 mJ, 40 mJ, 50 mJ, and 60 mJ. Results: Microscopic observations showed that the average of the ablation depth increased with the increase of the delivered energy from 30 mJ to 60 mJ. Mean values of the ablation depths were respectively as follows: 43.75 ± 4.89 µm for the energy of 30 mJ, 50.05 ± 3.72 µm for 40 mJ, 65.56 ± 10.35 µm for 50 mJ, and 74.80 ± 15.23 µm for 60 mJ. A statistically significant difference existed between the ablation depth of all groups. Conclusion: Based on our results, the depth of cementum debridement is related to the level of the delivered energy. The lowest energy levels (30 mJ and 40 mJ) can ablate the root cementum surface for a variable depth from 43.75 ± 4.89 μm to 50.05 ± 3.72 μm.
- 4 January 2023
- Published by Springer Nature
- p. 11-24
What Are Bulk Fill (BF) Composites and How Do They Differ from Non-BF Composites?
- 4 January 2023
- Published by Springer Nature
- p. 11-24
What Are Bulk Fill (BF) Composites and How Do They Differ from Non-BF Composites?
- Open Access
- 1 July 2020
- Published by MDPI AG in Dentistry Journal
- Vol. 8 (3) , 66
Comparison between Shear Bond Strength of Er:YAG and Er,Cr:YSGG Lasers-Assisted Dentinal Adhesion of Self-Adhering Resin Composite: An Ex Vivo Study
(1) Background: Bonding composite to tooth structure is still evolving with a substitute for phosphoric acid being the main challenge. Lately, a self-adhering composite (SAC) was developed, promising to simplify bonding to tooth structure. Unfortunately, retention especially to dentin, was not as good as the gold standard three steps bonding system. During the last 2 decades, lasers were used to enhance shear bond strength of composite to tooth structure. However, the literature provided limited information regarding laser efficiency in the immediate, as well as the long term, adhesion success of SACs to dentin. The purpose of our study was to define the optimal irradiation conditions to improve the adhesion of self-adhering flowable resin composite to dentin exposed to Er:YAG and Er,Cr:YSGG laser irradiation. (2) Methods: Seventy-two freshly extracted human third molars, prepared to have flat dentinal surfaces, were randomly divided into three groups (n = 24) including a control group (Group 1) in which dentin was left without laser irradiation. The other two groups (Group 2 and 3) received standardized irradiation at a speed of 1 mm/second with Er:YAG (60 mJ; SSP mode = 50 μs; 10 Hz; fluency of 9.4 J/cm2; beam diameter: 0.9 mm; air 6 mL/min; and water 4 mL/min), and Er,Cr:YSGG: 1.5 W; fluency of 17.8 J/cm2; turbo handpiece with MX5 short insert; 20 Hz under air/water spray (65% air, 55% water). Self-adhering flowable resin was applied to dentin in all groups. Half of the specimens were stored in water for 24 h while the other half underwent 3000 thermal cycles. Later, all specimens received a shear bond strength test. Fracture observation was done first under a stereomicroscope then by using a scanning electron microscope. (3) Results: The mean values of shear bond strength for both laser-treated dentin groups (Er:YAG laser: 13.10 ± 1.291, and Er,Cr:YSGG: 14.04 ± 5.233) were higher than in the control group 1 (8.355 ± 2.297) before thermocycling. After thermocycling, shear bond strength decreased in all groups as follows: 10.03 ± 1.503, 10.53 ± 2.631, and 02.75 ± 1.583 for Er:YAG, Er,Cr:YSGG, and nonirradiated dentin, respectively. Shear bond strength values showed a significant difference between the control group (Group 1) and both lasers groups (Group 2 and 3). Statistical analysis of stereomicroscope observation revealed no significant difference between laser irradiation and failure mode (p < 0.136). SEM observation of the dentin surface in both laser-irradiated groups showed opened tubules, absence of smear layer as well as an increase of resin infiltration into dentinal tubules. (4) Conclusion: Er:YAG and Er,Cr:YSGG lasers enhance self-adhering flowable resin shear bond strength values and improve its longevity by eliminating the smear layer, opening dentinal tubules and increasing resin infiltration into the microstructure.
- 1 July 2020
- Published by MDPI AG in Dentistry Journal
- Vol. 8 (3) , 66
Open AccessComparison between Shear Bond Strength of Er:YAG and Er,Cr:YSGG Lasers-Assisted Dentinal Adhesion of Self-Adhering Resin Composite: An Ex Vivo Study
(1) Background: Bonding composite to tooth structure is still evolving with a substitute for phosphoric acid being the main challenge. Lately, a self-adhering composite (SAC) was developed, promising to simplify bonding to tooth structure. Unfortunately, retention especially to dentin, was not as good as the gold standard three steps bonding system. During the last 2 decades, lasers were used to enhance shear bond strength of composite to tooth structure. However, the literature provided limited information regarding laser efficiency in the immediate, as well as the long term, adhesion success of SACs to dentin. The purpose of our study was to define the optimal irradiation conditions to improve the adhesion of self-adhering flowable resin composite to dentin exposed to Er:YAG and Er,Cr:YSGG laser irradiation. (2) Methods: Seventy-two freshly extracted human third molars, prepared to have flat dentinal surfaces, were randomly divided into three groups (n = 24) including a control group (Group 1) in which dentin was left without laser irradiation. The other two groups (Group 2 and 3) received standardized irradiation at a speed of 1 mm/second with Er:YAG (60 mJ; SSP mode = 50 μs; 10 Hz; fluency of 9.4 J/cm2; beam diameter: 0.9 mm; air 6 mL/min; and water 4 mL/min), and Er,Cr:YSGG: 1.5 W; fluency of 17.8 J/cm2; turbo handpiece with MX5 short insert; 20 Hz under air/water spray (65% air, 55% water). Self-adhering flowable resin was applied to dentin in all groups. Half of the specimens were stored in water for 24 h while the other half underwent 3000 thermal cycles. Later, all specimens received a shear bond strength test. Fracture observation was done first under a stereomicroscope then by using a scanning electron microscope. (3) Results: The mean values of shear bond strength for both laser-treated dentin groups (Er:YAG laser: 13.10 ± 1.291, and Er,Cr:YSGG: 14.04 ± 5.233) were higher than in the control group 1 (8.355 ± 2.297) before thermocycling. After thermocycling, shear bond strength decreased in all groups as follows: 10.03 ± 1.503, 10.53 ± 2.631, and 02.75 ± 1.583 for Er:YAG, Er,Cr:YSGG, and nonirradiated dentin, respectively. Shear bond strength values showed a significant difference between the control group (Group 1) and both lasers groups (Group 2 and 3). Statistical analysis of stereomicroscope observation revealed no significant difference between laser irradiation and failure mode (p < 0.136). SEM observation of the dentin surface in both laser-irradiated groups showed opened tubules, absence of smear layer as well as an increase of resin infiltration into dentinal tubules. (4) Conclusion: Er:YAG and Er,Cr:YSGG lasers enhance self-adhering flowable resin shear bond strength values and improve its longevity by eliminating the smear layer, opening dentinal tubules and increasing resin infiltration into the microstructure.