Chongjiu Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chongjiu Li has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Ma Xiaodong
Department of Applied Chemistry , China Agricultural University , Beijing, China
2 shared publicationsFengshou Dong
Department of Applied Chemistry, China Agricultural University, Beijing, China
1 shared publicationHui‐Xia Cai
Food Safety Institute, Chinese Academy of Inspection and Quarantine, Beijing 100025, PR China
1 shared publicationJuan An
Food Safety Institute, Chinese Academy of Inspection and Quarantine, Beijing 100025, PR China
1 shared publicationPing Wu
College of Information and Electrical Engineering, China Agricultural University, Beijing 100094, China
1 shared publicationQiao Cao
Pesticide Residues and Environmental Toxicology Group, Institute of Plant Protection, Chinese Academy of Agricultural Sciences, Beijing, China
1 shared publication
Latest Publications
Stereoselective degradation of fungicide triadimenol in cucumber plants
The stereoselective degradation of triadimenol in different cucumber plant tissues (root, stem, leaf, and fruit) has been investigated. Rac‐triadimenol was applied to cucumber plants by root irrigation mode under field conditions. The degradation kinetics and the enantiomer fraction were determined by normal‐phase high‐performance liquid chromatography with diode array detector and on‐line optical rotatory dispersion detector on Chiralpak® AS‐H column. It has been shown that the degradation of triadimenol in cucumber plants was stereoselective under field conditions. The results indicated that RS enantiomer was degraded faster than SR enantiomer, and SS enantiomer was degraded faster than RR enantiomer, which resulted in plants enriched with SR and RR enantiomers. Furthermore, it was found that leaf was the dominating location for triadimenol enantiomer accumulation and stereoselective degradation, comparing with the root, stem, and fruit tissue. Chirality 2010.
Stereoselective degradation of fungicide triadimenol in cucumber plants
The stereoselective degradation of triadimenol in different cucumber plant tissues (root, stem, leaf, and fruit) has been investigated. Rac‐triadimenol was applied to cucumber plants by root irrigation mode under field conditions. The degradation kinetics and the enantiomer fraction were determined by normal‐phase high‐performance liquid chromatography with diode array detector and on‐line optical rotatory dispersion detector on Chiralpak® AS‐H column. It has been shown that the degradation of triadimenol in cucumber plants was stereoselective under field conditions. The results indicated that RS enantiomer was degraded faster than SR enantiomer, and SS enantiomer was degraded faster than RR enantiomer, which resulted in plants enriched with SR and RR enantiomers. Furthermore, it was found that leaf was the dominating location for triadimenol enantiomer accumulation and stereoselective degradation, comparing with the root, stem, and fruit tissue. Chirality 2010.
- 25 February 2007
- Published by Taylor & Francis in Analytical Letters
- Vol. 40 (1) , 183-197
Rapid Multiresidue Determination Method for 100 Pesticides in Vegetables by One Injection Using Gas Chromatography/Mass Spectrometry with Selective Ion Storage Technology
A rapid multiresidue determination method for 100 pesticides (including organophosphorus, organochlorine, carbamate, and pyrethrines) in vegetables was described. The study focused on the fast separation and determination of target analytes. By optimizing the chromatographic condition and selecting specific ions of analytes, all analytes were determined by gas chromatography/ion‐trap mass spectrometry in selective ion storage mode (GC‐MS/SIS) within 35min. The sample was extracted by dichloromethane and acetone, cleaned up by graphitized carbon black (GCB) solid‐phase tubes. The limit of quantitation (LOQ) for most analytes was 0.01mg/kg.
- 25 February 2007
- Published by Taylor & Francis in Analytical Letters
- Vol. 40 (1) , 183-197
Rapid Multiresidue Determination Method for 100 Pesticides in Vegetables by One Injection Using Gas Chromatography/Mass Spectrometry with Selective Ion Storage Technology
A rapid multiresidue determination method for 100 pesticides (including organophosphorus, organochlorine, carbamate, and pyrethrines) in vegetables was described. The study focused on the fast separation and determination of target analytes. By optimizing the chromatographic condition and selecting specific ions of analytes, all analytes were determined by gas chromatography/ion‐trap mass spectrometry in selective ion storage mode (GC‐MS/SIS) within 35min. The sample was extracted by dichloromethane and acetone, cleaned up by graphitized carbon black (GCB) solid‐phase tubes. The limit of quantitation (LOQ) for most analytes was 0.01mg/kg.
- 1 May 2006
- Published by Taylor & Francis in Analytical Letters
- Vol. 39 (5) , 985-996
Application of Gas Chromatography‐Tandem Mass Spectrometry (GC‐MS‐MS) with Pulsed Splitless Injection for the Determination of Multiclass Pesticides in Vegetables
GC‐MS‐MS was used to analyze vegetables for 14 pesticide residues. In the same run, the optimal ionization mode (electron ionization or chemical ionization) for each pesticide was selected. The method includes a simple extraction procedure with acetone and dichloromethane. A solid‐phase extraction tube was used for cleanup. The 1 µL of the final solution was injected into the instrument by pulsed splitless injection mode that can improve the sensitivity. The average recoveries were ranged from 78% to 102%. The relative standard deviation was lower than 18.4%. The calculated limits of detection were equal or lower than 0.02 mg/kg.
- 1 May 2006
- Published by Taylor & Francis in Analytical Letters
- Vol. 39 (5) , 985-996
Application of Gas Chromatography‐Tandem Mass Spectrometry (GC‐MS‐MS) with Pulsed Splitless Injection for the Determination of Multiclass Pesticides in Vegetables
GC‐MS‐MS was used to analyze vegetables for 14 pesticide residues. In the same run, the optimal ionization mode (electron ionization or chemical ionization) for each pesticide was selected. The method includes a simple extraction procedure with acetone and dichloromethane. A solid‐phase extraction tube was used for cleanup. The 1 µL of the final solution was injected into the instrument by pulsed splitless injection mode that can improve the sensitivity. The average recoveries were ranged from 78% to 102%. The relative standard deviation was lower than 18.4%. The calculated limits of detection were equal or lower than 0.02 mg/kg.
- 20 April 2006
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 20 (10) , 1563-1568
Study of automated mass spectral deconvolution and identification system (AMDIS) in pesticide residue analysis
The effects of overlapping levels and concentration ratios of overlapping components, and of scan rates of the mass spectrometer, on the capability of the automated mass spectral deconvolution and identification system (AMDIS) in pesticide residue analysis were studied. To investigate the capability of AMDIS in removing interferences from the overlapping peaks, this system was applied to data files obtained from the gas chromatography/mass spectrometry (GC/MS) analysis of two overlapping (co‐eluting) pesticides ( β ‐HCH and PCNB) in full scan mode. Differences in overlap levels, the concentration ratios of the two overlapping components and the scan rates of the instrument were studied. When the difference in scan number of overlapping compounds was equal to 1 scan, AMDIS incompletely extracted ‘purified’ mass spectra but as the difference increased to 3 or more scans, complete correct spectra could be extracted. The results also show that when the scan rate was in the range of 0.4–0.90 s/scan and the concentration ratios of the target compound/interference were above 1/5, there were ideal deconvolution results for this approach. To further study the application of AMDIS to pesticide residue analysis, AMDIS was applied to the identification of pesticides spiked in real samples (cabbage and rice). Typical pesticides being evaluated were identified using AMDIS at concentrations >50 ng/g in the extracts. Copyright © 2006 John Wiley & Sons, Ltd.
- 20 April 2006
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 20 (10) , 1563-1568
Study of automated mass spectral deconvolution and identification system (AMDIS) in pesticide residue analysis
The effects of overlapping levels and concentration ratios of overlapping components, and of scan rates of the mass spectrometer, on the capability of the automated mass spectral deconvolution and identification system (AMDIS) in pesticide residue analysis were studied. To investigate the capability of AMDIS in removing interferences from the overlapping peaks, this system was applied to data files obtained from the gas chromatography/mass spectrometry (GC/MS) analysis of two overlapping (co‐eluting) pesticides ( β ‐HCH and PCNB) in full scan mode. Differences in overlap levels, the concentration ratios of the two overlapping components and the scan rates of the instrument were studied. When the difference in scan number of overlapping compounds was equal to 1 scan, AMDIS incompletely extracted ‘purified’ mass spectra but as the difference increased to 3 or more scans, complete correct spectra could be extracted. The results also show that when the scan rate was in the range of 0.4–0.90 s/scan and the concentration ratios of the target compound/interference were above 1/5, there were ideal deconvolution results for this approach. To further study the application of AMDIS to pesticide residue analysis, AMDIS was applied to the identification of pesticides spiked in real samples (cabbage and rice). Typical pesticides being evaluated were identified using AMDIS at concentrations >50 ng/g in the extracts. Copyright © 2006 John Wiley & Sons, Ltd.
- 27 January 2006
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 20 (4) , 609-617
Simultaneous determination of 109 pesticides in unpolished rice by a combination of gel permeation chromatography and Florisil column purification, and gas chromatography/mass spectrometry
A multi‐residue method is described for the simultaneous analysis of 109 pesticides with different properties in unpolished rice. The range covers organophosphorus, organochlorine, carbamate, and synthetic pyrethroid pesticides. The pesticides were extracted from the sample using ethyl acetate. Most higher molecular weight components such as lipids in the co‐extractives were removed by gel permeation chromatography (GPC) with a Bio‐bead SX‐3 column. A Florisil column with ethyl acetate/hexane as the eluting solvents was used for further cleanup. The pesticides were finally simultaneously determined by gas chromatography/mass spectrometry (GC/MS) in selective ion monitoring (SIM) mode. The average recoveries for most pesticides (spiked level 0.02, 0.1 and 1 µg/g) ranged from 70% to 110%, the relative standard deviation (RSD) was below 20% in every case, and the limit of detection (LOD) varied from 1 to 20 ng/g. Copyright © 2006 John Wiley & Sons, Ltd.
- 27 January 2006
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 20 (4) , 609-617
Simultaneous determination of 109 pesticides in unpolished rice by a combination of gel permeation chromatography and Florisil column purification, and gas chromatography/mass spectrometry
A multi‐residue method is described for the simultaneous analysis of 109 pesticides with different properties in unpolished rice. The range covers organophosphorus, organochlorine, carbamate, and synthetic pyrethroid pesticides. The pesticides were extracted from the sample using ethyl acetate. Most higher molecular weight components such as lipids in the co‐extractives were removed by gel permeation chromatography (GPC) with a Bio‐bead SX‐3 column. A Florisil column with ethyl acetate/hexane as the eluting solvents was used for further cleanup. The pesticides were finally simultaneously determined by gas chromatography/mass spectrometry (GC/MS) in selective ion monitoring (SIM) mode. The average recoveries for most pesticides (spiked level 0.02, 0.1 and 1 µg/g) ranged from 70% to 110%, the relative standard deviation (RSD) was below 20% in every case, and the limit of detection (LOD) varied from 1 to 20 ng/g. Copyright © 2006 John Wiley & Sons, Ltd.