Jingjing Ye
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jingjing Ye has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Xiaoying Li
Department of Ultrasonography, Children's Hospital, School of Medicine, Zhejiang University, Hangzhou, China
2 shared publicationsXiuzhen Yang
Department of Ultrasonography, Children's Hospital, School of Medicine, Zhejiang University, Hangzhou, China
2 shared publications- Bin Xu
Department of Ultrasound, The Children's Hospital of Zhejiang University School of Medicine, Hangzhou, 310003, China
1 shared publication Guoping Jiang
Department of Ultrasound, Zhejiang University School of Medicine, Childrens Hospital, Hangzhou, 310003, Zhejiang, Peoples Republic of China
1 shared publication- Guoping Jiang
Department of Ultrasound, The Children's Hospital of Zhejiang University School of Medicine, Hangzhou, 310003, China
1 shared publication - Jin He
Department of Ultrasound, The Children's Hospital of Zhejiang University School of Medicine, Hangzhou, 310003, China
1 shared publication
Latest Publications
- 1 December 2017
- Published by Elsevier in Journal of Pediatric and Adolescent Gynecology
- Vol. 30 (6) , 620-625
Ultrasonography in Detection of Vaginal Foreign Bodies in Girls: A Retrospective Study
- 1 December 2017
- Published by Elsevier in Journal of Pediatric and Adolescent Gynecology
- Vol. 30 (6) , 620-625
Ultrasonography in Detection of Vaginal Foreign Bodies in Girls: A Retrospective Study
- 25 May 2017
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 27 (8) , 1651-1653
Double aortic arch presenting with a foreign object in the oesophagus: a case report and imaging diagnosis
In this article, we report a rare case of double aortic arch. The case presented initially with a foreign object in the oesophagus. The patient was a 2-year-old boy, who was referred with primary symptoms of tussis (15 days) and emesis (2 days). He had a history of ingesting a coin. Routine chest X-ray indicated a rounded, metal foreign object in the upper oesophagus. A half-Yuan coin was removed by gastroduodenoscopy. Echocardiographic imaging suggested that the patient had double aortic arch, which was subsequently diagnosed by CT angiography with three-dimensional reconstruction. The right subclavian artery arose from the right loop of the double aortic arch. The left subclavian artery as well as left and right common carotid arteries had distinct origins from the left aortic arch. Imaging also indicated atresia of the distal left arch. The patient underwent corrective surgery and made a full recovery. Despite the rarity, double aortic arch should be considered when patients present with a foreign object in the oesophagus. Echocardiography and CT angiography can inform the diagnosis.
- 25 May 2017
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 27 (8) , 1651-1653
Double aortic arch presenting with a foreign object in the oesophagus: a case report and imaging diagnosis
In this article, we report a rare case of double aortic arch. The case presented initially with a foreign object in the oesophagus. The patient was a 2-year-old boy, who was referred with primary symptoms of tussis (15 days) and emesis (2 days). He had a history of ingesting a coin. Routine chest X-ray indicated a rounded, metal foreign object in the upper oesophagus. A half-Yuan coin was removed by gastroduodenoscopy. Echocardiographic imaging suggested that the patient had double aortic arch, which was subsequently diagnosed by CT angiography with three-dimensional reconstruction. The right subclavian artery arose from the right loop of the double aortic arch. The left subclavian artery as well as left and right common carotid arteries had distinct origins from the left aortic arch. Imaging also indicated atresia of the distal left arch. The patient underwent corrective surgery and made a full recovery. Despite the rarity, double aortic arch should be considered when patients present with a foreign object in the oesophagus. Echocardiography and CT angiography can inform the diagnosis.
- 3 November 2016
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 45 (3) , 179-182
Sonographic diagnosis of splenogonadal fusion in a 2‐year‐old boy
Splenogonadal fusion (SGF) is a rare congenital abnormality. It is typically identified during orchiectomy for a suspected testicular tumor or during orchiopexy. We describe the sonographic findings in a case of SGF that could help with correct diagnosis preoperatively. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:179–182, 2017
- 3 November 2016
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 45 (3) , 179-182
Sonographic diagnosis of splenogonadal fusion in a 2‐year‐old boy
Splenogonadal fusion (SGF) is a rare congenital abnormality. It is typically identified during orchiectomy for a suspected testicular tumor or during orchiopexy. We describe the sonographic findings in a case of SGF that could help with correct diagnosis preoperatively. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:179–182, 2017
- 22 September 2016
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 34 (11) , 738-746
Research on pediatric glomerular disease and normal kidney with shear wave based elastography point quantification
Purpose To evaluate the renal cortex stiffness in children with glomerular disease by shear wave based elastography point quantification (ElastPQ), and to investigate the association between shear wave velocity (SWV) in the renal cortex and age in normal children, and the inter-gender differences. Materials and methods One hundred and five children who were pathologically confirmed with glomerular diseases were selected as the disease group. Meanwhile, 120 healthy children were selected as the control group. Effective values were measured 5 times at the same kidney sites on each side. Results Comparisons of SWV measurements between left and right kidneys in the disease and control groups all showed significant differences (left kidney t = 6.896, P = 0.004; right kidney t = 7.415, P = 0.001). In the control group, left and right kidney SWV measurements were all positively correlated with age (left kidney r = 0.792, P = 0.003; right kidney r = 0.794, P = 0.004). Moreover, inter-gender difference was present in the right kidney measurements. Conclusions ElastPQ technology has certain advantages in predicting pediatric glomerular disease compared to conventional ultrasound. ElastPQ technology contributes to the early diagnosis of the disease.
- 22 September 2016
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 34 (11) , 738-746
Research on pediatric glomerular disease and normal kidney with shear wave based elastography point quantification
Purpose To evaluate the renal cortex stiffness in children with glomerular disease by shear wave based elastography point quantification (ElastPQ), and to investigate the association between shear wave velocity (SWV) in the renal cortex and age in normal children, and the inter-gender differences. Materials and methods One hundred and five children who were pathologically confirmed with glomerular diseases were selected as the disease group. Meanwhile, 120 healthy children were selected as the control group. Effective values were measured 5 times at the same kidney sites on each side. Results Comparisons of SWV measurements between left and right kidneys in the disease and control groups all showed significant differences (left kidney t = 6.896, P = 0.004; right kidney t = 7.415, P = 0.001). In the control group, left and right kidney SWV measurements were all positively correlated with age (left kidney r = 0.792, P = 0.003; right kidney r = 0.794, P = 0.004). Moreover, inter-gender difference was present in the right kidney measurements. Conclusions ElastPQ technology has certain advantages in predicting pediatric glomerular disease compared to conventional ultrasound. ElastPQ technology contributes to the early diagnosis of the disease.
- 6 June 2008
- Published by Springer Nature in Pediatric Radiology
- Vol. 38 (9) , 1021-1023
Percutaneous radiofrequency ablation for treatment of hepatoblastoma recurrence
Radiofrequency ablation (RFA) has been widely reported as a minimally invasive treatment for liver tumours in adults, but has not been documented as a treatment for hepatoblastoma in a child. We report a 2-year-old boy with local recurrence of hepatoblastoma after partial hepatectomy. Percutaneous RFA was performed under real-time sonographic guidance. There was no imaging evidence of recurrence after a follow-up of 2 years. We consider this a promising technique in children.
- 6 June 2008
- Published by Springer Nature in Pediatric Radiology
- Vol. 38 (9) , 1021-1023
Percutaneous radiofrequency ablation for treatment of hepatoblastoma recurrence
Radiofrequency ablation (RFA) has been widely reported as a minimally invasive treatment for liver tumours in adults, but has not been documented as a treatment for hepatoblastoma in a child. We report a 2-year-old boy with local recurrence of hepatoblastoma after partial hepatectomy. Percutaneous RFA was performed under real-time sonographic guidance. There was no imaging evidence of recurrence after a follow-up of 2 years. We consider this a promising technique in children.