Eric Moore
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eric Moore has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Paul Galvin
Tyndall National Institute, University College Cork, Cork, Ireland
4 shared publications - Alan O'RIordan
Precision Electrochemical Nanosensors Group University College Cork Tyndall National Institute Cork Ireland
1 shared publication - Anita Rose Maguire
School of Chemistry, University College Cork, College Road, Cork T12 YN60, Ireland
1 shared publication Anna Hogan
Tyndall National Institute, University College Cork
1 shared publicationAzrilawani Ahmad
Nanobio System Group, Tyndall National Institute , Cork, Ireland
1 shared publication- Azrilawani Ahmad
Faculty of Science and Marine Environment, Universiti Malaysia Terengganu, Terengganu, Malaysia
1 shared publication
Latest Publications
- Open Access
- 1 October 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 757 (1) , 012042
A novel CE microchip with micro pillars column & double-L injection design for Capacitance Coupled Contactless Conductivity detection technology
This novel capillary electrophoresis microchip, or also known as μTAS (micro total analysis system) was designed to separate complex aqueous based compounds, similar to commercial CE & microchip (capillary electrophoresis) systems, but more compact. This system can be potentially used for mobile/portable chemical analysis equipment. Un-doped silicon wafer & ultra-thin borofloat glass (Pyrex) wafers have been used to fabricate the device. Double-L injection feature, micro pillars column, bypass separation channel & hybrid- referenced C4D electrodes were designed to achieve a high SNR (signal to noise ratio), easy- separation, for a durable and reusable μTAS for CE use.
- 1 October 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 757 (1) , 012042
Open AccessA novel CE microchip with micro pillars column & double-L injection design for Capacitance Coupled Contactless Conductivity detection technology
This novel capillary electrophoresis microchip, or also known as μTAS (micro total analysis system) was designed to separate complex aqueous based compounds, similar to commercial CE & microchip (capillary electrophoresis) systems, but more compact. This system can be potentially used for mobile/portable chemical analysis equipment. Un-doped silicon wafer & ultra-thin borofloat glass (Pyrex) wafers have been used to fabricate the device. Double-L injection feature, micro pillars column, bypass separation channel & hybrid- referenced C4D electrodes were designed to achieve a high SNR (signal to noise ratio), easy- separation, for a durable and reusable μTAS for CE use.
- 24 May 2016
- Published by Taylor & Francis in Analytical Letters
- Vol. 50 (1) , 1-32
Electrochemical Immunosensors for Food Analysis: A Review of Recent Developments
Electrochemical immunosensors have the potential to transform analytical procedures within the food industry by providing highly specific, rapid, and inexpensive determination of pathogens. In this paper, recent advances in this area are outlined. In particular, attention is paid to new methods that have been developed for the modification of working electrode surfaces. Many advances have been related to the use of novel nanomaterials such as carbon nanotubes, graphene, and metallic nanoparticles, often used in conjunction with each other or polymers. The use of these materials has generally provided superior sensor sensitivity. The application of immunosensors to the detection of a range of pathogens in real samples is then investigated to establish whether they provide solutions in practical applications.
- 24 May 2016
- Published by Taylor & Francis in Analytical Letters
- Vol. 50 (1) , 1-32
Electrochemical Immunosensors for Food Analysis: A Review of Recent Developments
Electrochemical immunosensors have the potential to transform analytical procedures within the food industry by providing highly specific, rapid, and inexpensive determination of pathogens. In this paper, recent advances in this area are outlined. In particular, attention is paid to new methods that have been developed for the modification of working electrode surfaces. Many advances have been related to the use of novel nanomaterials such as carbon nanotubes, graphene, and metallic nanoparticles, often used in conjunction with each other or polymers. The use of these materials has generally provided superior sensor sensitivity. The application of immunosensors to the detection of a range of pathogens in real samples is then investigated to establish whether they provide solutions in practical applications.
- 22 May 2015
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 59 (8) , 962-974
Nerve localization techniques for peripheral nerve block and possible future directions
Background: Ultrasound guidance is now a standard nerve localization technique for peripheral nerve block (PNB). Ultrasonography allows simultaneous visualization of the target nerve, needle, local anesthetic injectate, and surrounding anatomical structures. Accurate deposition of local anesthetic next to the nerve is essential to the success of the nerve block procedure. Due to limitations in the visibility of both needle tip and nerve surface, the precise relationship between needle tip and target nerve is unknown at the moment of injection. Importantly, nerve injury may result both from an inappropriately placed needle tip and inappropriately placed local anesthetic. The relationship between the block needle tip and target nerve is of paramount importance to the safe conduct of peripheral nerve block.Methods: This review summarizes the evolution of nerve localization in regional anesthesia, characterizes a problem faced by clinicians in performing ultrasound‐guided nerve block, and explores the potential technological solutions to this problem.Results: To date, technology newly applied to PNB includes real‐time 3D imaging, multi‐planar magnetic needle guidance, and inline injection pressure monitoring. This review postulates that optical reflectance spectroscopy and bioimpedance may allow for accurate identification of the relationship between needle tip and target nerve, currently a high priority deficit in PNB techniques.Conclusions: Until it is known how best to define the relationship between needle and nerve at the moment of injection, some common sense principles are suggested.
- 22 May 2015
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 59 (8) , 962-974
Nerve localization techniques for peripheral nerve block and possible future directions
Background: Ultrasound guidance is now a standard nerve localization technique for peripheral nerve block (PNB). Ultrasonography allows simultaneous visualization of the target nerve, needle, local anesthetic injectate, and surrounding anatomical structures. Accurate deposition of local anesthetic next to the nerve is essential to the success of the nerve block procedure. Due to limitations in the visibility of both needle tip and nerve surface, the precise relationship between needle tip and target nerve is unknown at the moment of injection. Importantly, nerve injury may result both from an inappropriately placed needle tip and inappropriately placed local anesthetic. The relationship between the block needle tip and target nerve is of paramount importance to the safe conduct of peripheral nerve block.Methods: This review summarizes the evolution of nerve localization in regional anesthesia, characterizes a problem faced by clinicians in performing ultrasound‐guided nerve block, and explores the potential technological solutions to this problem.Results: To date, technology newly applied to PNB includes real‐time 3D imaging, multi‐planar magnetic needle guidance, and inline injection pressure monitoring. This review postulates that optical reflectance spectroscopy and bioimpedance may allow for accurate identification of the relationship between needle tip and target nerve, currently a high priority deficit in PNB techniques.Conclusions: Until it is known how best to define the relationship between needle and nerve at the moment of injection, some common sense principles are suggested.
- 5 October 2012
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 137 (24) , 5839-5844
Electrochemical immunosensor modified with self-assembled monolayer of 11-mercaptoundecanoic acid on gold electrodes for detection of benzo[a]pyrene in water
Well-oriented bio-conjugates on gold electrode surfaces will indirectly influence the molecular recognition of antigens to surface bound antibodies thus improving the detection performance of electrochemical immunosensors. This paper describes the modification of self-assembled monolayers (SAMs) on gold electrode surface with 11-mercaptoundecanoic acid (11-MUA). Activation of carboxylic acid terminal was performed by reaction of a mixture of water soluble carbodiimide and N-hydrosuccinimide (NHS) on the electrode surfaces. Characterisation of the SAM formation on the gold electrode was performed using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and contact angle measurements. An amperometric immunosensor was developed for the screening of polycyclic aromatic hydrocarbons (PAHs) in water. The system consists of gold as the working electrode, platinum as the counter electrode and a Ag/AgCl reference electrode. This three electrode system is integrated on a single chip. The measurement employs the enzyme-linked immunosorbent assay (ELISA) principle. Benzo[a]pyrene (BaP) was detected using an immunological reaction by measuring the alkaline phosphatase (AP) enzymatic reaction towards the substrate para-amino phenyl phosphate (pAPP). A competitive assay was performed within the electrode using AP as the labelled-enzyme. A lower limit of detection (5.6 ng ml−1) of BaP was achieved after the activation of the mixture of carbodiimide and succinimide with the alkanethiol SAM on the gold electrode in comparison to that obtained for the unmodified electrode (14.2 ng ml−1). The developed surface functionalised sensor demonstrated acceptable reproducibility and good stability, with a wide linear response to BaP (4–140 ng ml−1).
- 5 October 2012
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 137 (24) , 5839-5844
Electrochemical immunosensor modified with self-assembled monolayer of 11-mercaptoundecanoic acid on gold electrodes for detection of benzo[a]pyrene in water
Well-oriented bio-conjugates on gold electrode surfaces will indirectly influence the molecular recognition of antigens to surface bound antibodies thus improving the detection performance of electrochemical immunosensors. This paper describes the modification of self-assembled monolayers (SAMs) on gold electrode surface with 11-mercaptoundecanoic acid (11-MUA). Activation of carboxylic acid terminal was performed by reaction of a mixture of water soluble carbodiimide and N-hydrosuccinimide (NHS) on the electrode surfaces. Characterisation of the SAM formation on the gold electrode was performed using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and contact angle measurements. An amperometric immunosensor was developed for the screening of polycyclic aromatic hydrocarbons (PAHs) in water. The system consists of gold as the working electrode, platinum as the counter electrode and a Ag/AgCl reference electrode. This three electrode system is integrated on a single chip. The measurement employs the enzyme-linked immunosorbent assay (ELISA) principle. Benzo[a]pyrene (BaP) was detected using an immunological reaction by measuring the alkaline phosphatase (AP) enzymatic reaction towards the substrate para-amino phenyl phosphate (pAPP). A competitive assay was performed within the electrode using AP as the labelled-enzyme. A lower limit of detection (5.6 ng ml−1) of BaP was achieved after the activation of the mixture of carbodiimide and succinimide with the alkanethiol SAM on the gold electrode in comparison to that obtained for the unmodified electrode (14.2 ng ml−1). The developed surface functionalised sensor demonstrated acceptable reproducibility and good stability, with a wide linear response to BaP (4–140 ng ml−1).
- 1 August 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2010 (1094687X) , 302-304
Development of a toxin screening multi-parameter on-line biochip system ‘Toxichip’
The development of a cell based biochip-sensing platform that examines the effects of toxic chemicals both electrically and optically is presented. The name of this sensing platform is called Toxichip. Toxichip aims to develop and promote alternative novel in-vitro testing methods for the monitoring of a vast array of toxins, thus alleviating the current demand for animal sacrifice while also permitting high throughput screening. Cell-based biosensors (CBBs), which treat living cells as sensing elements, are able to detect the functional information of biologically active analytes and also provide quantitative analysis. In general, they maintain living cells and observe the cellular physiological response after subjecting cells to toxin stimuli and verify the presence and the concentration of these stimuli. CBBs characterise with high sensitivity, excellent selectivity and a fast response time. There has been increased interest in the use of microelectronic biosensors that allow cellular activity to be analysed in vitro.
- 1 August 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2010 (1094687X) , 302-304
Development of a toxin screening multi-parameter on-line biochip system ‘Toxichip’
The development of a cell based biochip-sensing platform that examines the effects of toxic chemicals both electrically and optically is presented. The name of this sensing platform is called Toxichip. Toxichip aims to develop and promote alternative novel in-vitro testing methods for the monitoring of a vast array of toxins, thus alleviating the current demand for animal sacrifice while also permitting high throughput screening. Cell-based biosensors (CBBs), which treat living cells as sensing elements, are able to detect the functional information of biologically active analytes and also provide quantitative analysis. In general, they maintain living cells and observe the cellular physiological response after subjecting cells to toxin stimuli and verify the presence and the concentration of these stimuli. CBBs characterise with high sensitivity, excellent selectivity and a fast response time. There has been increased interest in the use of microelectronic biosensors that allow cellular activity to be analysed in vitro.
- 20 January 2009
- Published by Taylor & Francis in Analytical Letters
- Vol. 42 (1) , 1-28
Comparison of Cell-Based Biosensors with Traditional Analytical Techniques for Cytotoxicity Monitoring and Screening of Polycyclic Aromatic Hydrocarbons in the Environment
Today, special attention is paid to the environmental pollution effects of polycyclic aromatic hydrocarbons (PAHs), which are carcinogenic and mutagenic compounds. They are also widely distributed in the environment and can be found in water, soil, and plants. For this reason, various technologies have been developed to detect and screen for PAHs, and one of the recent developments is cell-based biosensors (CBBs). This type of sensor allows for real-time measurements by detecting the impedance of cellular behavior, which has been proven sensitive to toxic compounds. This articles presents a review of the previous work on CBBs for environmental monitoring of PAHs, in comparison with other conventional methods, which are based on chromatographic techniques and immunoassay.
- 20 January 2009
- Published by Taylor & Francis in Analytical Letters
- Vol. 42 (1) , 1-28
Comparison of Cell-Based Biosensors with Traditional Analytical Techniques for Cytotoxicity Monitoring and Screening of Polycyclic Aromatic Hydrocarbons in the Environment
Today, special attention is paid to the environmental pollution effects of polycyclic aromatic hydrocarbons (PAHs), which are carcinogenic and mutagenic compounds. They are also widely distributed in the environment and can be found in water, soil, and plants. For this reason, various technologies have been developed to detect and screen for PAHs, and one of the recent developments is cell-based biosensors (CBBs). This type of sensor allows for real-time measurements by detecting the impedance of cellular behavior, which has been proven sensitive to toxic compounds. This articles presents a review of the previous work on CBBs for environmental monitoring of PAHs, in comparison with other conventional methods, which are based on chromatographic techniques and immunoassay.
- 3 December 2008
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 139 (1) , 187-193
Monitoring of cell growth in vitro using biochips packaged with indium tin oxide sensors
- 3 December 2008
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 139 (1) , 187-193
Monitoring of cell growth in vitro using biochips packaged with indium tin oxide sensors
- 23 May 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 8 (5) , 536-542
An Integrated Optofluidic Platform for DNA Hybridization and Detection
There has been extensive research into micro total analysis systems (micro-TAS) and lab-on-a-chip research due to the benefits of increased sample throughput, reduced sample consumption, and rapid analysis times. The integration of low-cost fluidic and optical components offers the possibility of complex systems with increased functionality on a single detection platform. For the development of an integrated optofluidic system for DNA hybridization, the key areas are optical/fluidic integration and the efficiency of surface chemistry integration within the system. The impact of fluidic parameters such as flow rate, channel height, and time on hybridization performance is to optimize detection performance over conventional assay (microtiter plate formats). The use of a passive waveguide device means DNA binding events can be monitored using fluorescence excitation or refractive index measurement. The integration of the three areas is enhanced by the robustness of the waveguide material (oxide, nitride), enabling chemical functionalization by initial silanization followed by addition of a linker molecule 1,4 phenylene diisothiocyanate (PDITC) for covalent immobilization of DNA probes together with the possibility to define microfluidics on the waveguide substrate using standard SU8 photolithography. The fluidic design requires 240 nl of analyte to fill the integrated optofluidic system. Here, we report the novel integration and optimization of a covalent surface chemistry with microfluidic channels for fluidic delivery, and a standard resonant mirror (RM) waveguide detection platform. The optofluidic detection platform was tested using fluorescence and refractive index to monitor binding events between target and probe DNA. We describe the detection system, using simulations to explain the response to changes in refractive index and outline a method for covalent attachment of DNA probes surface chemistry protocol to immobilize probe DNA on the sensor surface and the optimization of fluidic design, achieving pM detection limit. We highlight the benefit of optimizing the fluidic component and its benefit in hybridization efficiency an approach often overlooked in sensor design and performance.
- 23 May 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 8 (5) , 536-542
An Integrated Optofluidic Platform for DNA Hybridization and Detection
There has been extensive research into micro total analysis systems (micro-TAS) and lab-on-a-chip research due to the benefits of increased sample throughput, reduced sample consumption, and rapid analysis times. The integration of low-cost fluidic and optical components offers the possibility of complex systems with increased functionality on a single detection platform. For the development of an integrated optofluidic system for DNA hybridization, the key areas are optical/fluidic integration and the efficiency of surface chemistry integration within the system. The impact of fluidic parameters such as flow rate, channel height, and time on hybridization performance is to optimize detection performance over conventional assay (microtiter plate formats). The use of a passive waveguide device means DNA binding events can be monitored using fluorescence excitation or refractive index measurement. The integration of the three areas is enhanced by the robustness of the waveguide material (oxide, nitride), enabling chemical functionalization by initial silanization followed by addition of a linker molecule 1,4 phenylene diisothiocyanate (PDITC) for covalent immobilization of DNA probes together with the possibility to define microfluidics on the waveguide substrate using standard SU8 photolithography. The fluidic design requires 240 nl of analyte to fill the integrated optofluidic system. Here, we report the novel integration and optimization of a covalent surface chemistry with microfluidic channels for fluidic delivery, and a standard resonant mirror (RM) waveguide detection platform. The optofluidic detection platform was tested using fluorescence and refractive index to monitor binding events between target and probe DNA. We describe the detection system, using simulations to explain the response to changes in refractive index and outline a method for covalent attachment of DNA probes surface chemistry protocol to immobilize probe DNA on the sensor surface and the optimization of fluidic design, achieving pM detection limit. We highlight the benefit of optimizing the fluidic component and its benefit in hybridization efficiency an approach often overlooked in sensor design and performance.
- 25 January 2007
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (5) , 2050-2057
Selective Release of DNA from the Surface of Indium−Tin Oxide Thin Electrode Films Using Thiol−Disulfide Exchange Chemistry
A new challenge in biointerfacial science is the development of dynamic surfaces with the ability to adjust and tune the chemical functionality at the interface between the biological and nonbiological entities. In this paper we describe fabrication of indium−tin oxide (ITO) electrodes and the design of a ligand that can be switched to enable selectively controlled interactions with DNA. Tailoring the surface composition of the ITO electrode to optimize its optical and electrical properties was also studied. The surface attachment chemistry investigated utilizes thiol−disulfide exchange chemistry. This chemistry involved the covalent attachment of a thiol-functionalized silane anchor to a hydroxyl-activated ITO electrode surface. Subsequent reaction with 2-(2-pyridinyldithio)ethanamine hydrochloride formed the disulfide bridge and provided the terminal amine group, which facilitates addition of a cross-linker. DNA was then covalently bound to the cross-linker, and hybridization with the complementary Cy3-labeled target DNA was achieved. Selective release of the attached DNA was demonstrated by both chemical and electrical reduction of the disulfide bond. The surface chemistry was then recycled, and rehybridization of the target DNA was achieved. The ability to control specific release of biomolecules has applications for the development of novel biosensor platforms and a range of medical devices.
- 25 January 2007
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (5) , 2050-2057
Selective Release of DNA from the Surface of Indium−Tin Oxide Thin Electrode Films Using Thiol−Disulfide Exchange Chemistry
A new challenge in biointerfacial science is the development of dynamic surfaces with the ability to adjust and tune the chemical functionality at the interface between the biological and nonbiological entities. In this paper we describe fabrication of indium−tin oxide (ITO) electrodes and the design of a ligand that can be switched to enable selectively controlled interactions with DNA. Tailoring the surface composition of the ITO electrode to optimize its optical and electrical properties was also studied. The surface attachment chemistry investigated utilizes thiol−disulfide exchange chemistry. This chemistry involved the covalent attachment of a thiol-functionalized silane anchor to a hydroxyl-activated ITO electrode surface. Subsequent reaction with 2-(2-pyridinyldithio)ethanamine hydrochloride formed the disulfide bridge and provided the terminal amine group, which facilitates addition of a cross-linker. DNA was then covalently bound to the cross-linker, and hybridization with the complementary Cy3-labeled target DNA was achieved. Selective release of the attached DNA was demonstrated by both chemical and electrical reduction of the disulfide bond. The surface chemistry was then recycled, and rehybridization of the target DNA was achieved. The ability to control specific release of biomolecules has applications for the development of novel biosensor platforms and a range of medical devices.