JBJustus‐Martijn Brinkman

Justus‐Martijn Brinkman

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Justus‐Martijn Brinkman has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Christof Hurschler

    Laboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany

    3 shared publications
  • R. J. van Heerwaarden

    <!--1--> Department of Orthopaedics, Limb Deformity Reconstruction Unit Sint Maartenskliniek P.O. Box 8000 3440 JD Woerden The Netherlands

    3 shared publications
  • A. E. Staubli

    <!--3--> Department of Orthopaedic Surgery Privatklinik Sonnmatt Hemschlenstrasse 6000 Lucerne 15 Switzerland

    2 shared publications
  • D. Freiling

    <!--3--> Department of Trauma and Reconstructive Surgery Henriettenstiftung, Marienstrasse 72‐90 30171 Hannover Germany

    1 shared publication
  • J. D. Agneskirchner

    <!--3--> Department of Trauma and Reconstructive Surgery Henriettenstiftung, Marienstrasse 72‐90 30171 Hannover Germany

    1 shared publication
  • Peter Walker

    Orthopedics Hip and Knee Clinic Sydney New South Wales Australia

    1 shared publication

Latest Publications

  • Midterm results using a medial pivot total knee replacement compared with the Australian National Joint Replacement Registry data

    by Justus‐Martijn Brinkman, Preet Singh Bubra, Peter Walker, William R. Walsh, Warrick J. M. Bruce

    Background: In order to emulate normal knee kinematics more closely, and thereby potentially improve wear characteristics and implant longevity, the medial pivot‐type knee replacement geometry was designed. In the current study the outcome of 50 consecutive knee replacements using a medial pivot‐type knee replacement was compared with the results in the Australian Orthopaedic Association National Joint Replacement Registry.Methods: Pre‐ and post‐operatively at follow‐up evaluation consisted of the Knee Society score system and the Western Ontario and McMaster Universities Arthritis Index Score. Patient satisfaction was documented using 5‐point Likert‐type scales. Standard radiographs were used to assess signs of radiographic failure. Revisions were subcategorized into major total, major partial and minor. Patient records were cross‐referenced against the Australian Orthopaedic Associations National Joint Replacement Registry's and the outcome compared with the registry's subset of data on the medial pivot knee used.Results: According to the patients' Knee Society score system and Western Ontario and McMaster Universities Arthritis Index scores, there was good pain relief and functional improvement; none of the implants showed radiographic signs of failure. There was one minor revision. There was no statistically significant difference in revision rate compared with the registry results.Discussion: The medial pivot knee‐type implant in this series provided pain relief, functional improvement and a revision rate, similar to what is reported in the literature after a longer follow‐up period, which is reassuring for those who use this type of implant on a day‐to‐day basis.


  • Axial and torsional stability of an improved single‐plane and a new bi‐plane osteotomy technique for supracondylar femur osteotomies

    by J.‐M. Brinkman, C. Hurschler, A. E. Staubli, R. J. van Heerwaarden

    Purpose: An important disadvantage of the standard medial closing‐wedge distal femur osteotomy for lateral compartment osteoarthritis of the knee is the immediate effects on the extensor mechanism function. Therefore, a novel bi‐plane osteotomy technique was developed. The stability and stiffness of this newly developed technique and a modification of the proximal screw configuration were tested in a composite femur model and compared to the standard single‐plane technique. Research question was if the new bi‐plane technique and/or modified screw configuration would improve the stability and stiffness of the construct.Methods: In 12 femurs, motion at the osteotomy under axial and torsion loading was measured using a 3D motion analysis system. All were subsequently tested to failure. The data recorded were used to calculate stability and stiffness of the constructs.Results: The stability and stiffness were highest in the bi‐plane technique under axial loads, but were lower under torsional loading, compared to the single‐plane technique. The screw configuration modification improved axial stability and stiffness, but had no influence on torsional stability.Conclusion: In replicate femurs, the new bi‐plane technique improved axial stability, but in contrast to what was theorized, decreased torsional stability, compared to the single‐plane technique. The addition of a bi‐cortical screw proximally improved stability under axial loading, but not torsion. Further clinical testing will have to prove if early full weight bearing using the new bi‐plane technique is possible.


  • Axial and torsional stability of supracondylar femur osteotomies: biomechanical comparison of the stability of five different plate and osteotomy configurations

    by J.‐M. Brinkman, C. Hurschler, J. D. Agneskirchner, D. Freiling, R. J. van Heerwaarden

    Purpose: Little is known regarding the biomechanical stability and stiffness of implants and techniques used in supracondylar femur osteotomies (SCO). Therefore, fixation stability and stiffness of implants to bone was investigated under simulated physiological loading conditions using a composite femur model and a 3D motion‐analysis system.Methods: Five osteotomy configurations were investigated: (1) oblique medial closing‐wedge fixated with an angle‐stable implant; (2) oblique and (3) perpendicular medial closing‐wedge, both fixated with an angled blade plate; and lateral opening‐wedge fixated with (4) a spacer plate and (5) an angle‐stable lateral implant. The motion measured at the osteotomy was used to calculate the stiffness and stability of the constructs.Results: The least amount of motion and highest stiffness was measured in the medial oblique closing‐wedge osteotomy fixated with the angled blade plate. The lateral opening‐wedge techniques were less stable and had a lower stiffness compared with the medial; the oblique saw cuts were more stable and had a higher stiffness than the perpendicular.Conclusion: This experimental study presents baseline data on the differences in the primary stability of bone–implant constructs used in SCO. The data in this study can be used as reference for future testing of SCO techniques. Furthermore, it is recommended that based on the differences found, the early postoperative rehabilitation protocol is tailored to the stability and stiffness of the fixation method used.