R. V. Robertson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
R. V. Robertson has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
G. D. Earle
Center for Space Science and Engineering Research, Virginia Tech, Blacksburg, Virginia 24060, USA
2 shared publications- L. J. Kordella
Bradley Department of Electrical and Computer Engineering Virginia Polytechnic Institute and State University Blacksburg VA USA
2 shared publications R. L. Davidson
Electrical and Computer Engineering Department, Utah State University, Logan, Utah 84322, USA
2 shared publicationsS. Noel
Center for Space Science and Engineering Research, Virginia Tech, Blacksburg, Virginia 24060, USA
2 shared publications- V. Garg
Lutron Electronics, Allentown, Pennsylvania 18106, USA
2 shared publications - André Luiz Felix Rodacki
Department of Physical Education, Federal University of Paraná, Curitiba, Paraná, Brazil
1 shared publication
Latest Publications
- 1 October 2018
- Published by Taylor & Francis in Experimental Aging Research
- Vol. 44 (5) , 397-410
Validity, Reliability, and Diagnostic Accuracy of Ratings of Perceived Exertion to Identify Dependence in Performing Self-care Activities in Older Women
Background: Dependence in self-care activities among older women has been previously evaluated through performance-based tests. However, these tests have presented inability to accurately distinguish between dependent and independent older adults in performing activities of daily living. Aim: To examine the validity, reliability, and diagnostic accuracy of rating of perceived exertion (RPE) to identify dependence in performing self-care activities in older women. Methods: Thirty-five older women performed two different constant-load tasks (walking on treadmill at 4 km/h for five minutes and arm curls with two kg for one minute), reporting RPE at the end, in four sessions. Performance-based tests (30-second chair stand and 6-minute walk) were also evaluated. Katz Index and Lawton and Brody questionnaires were applied to evaluate the dependence level in performing basic and instrumental activities of daily living. Results: RPE was greater on the first session (RPE 14 ± 2) than second session (RPE 13 ± 2), while it was similar through other sessions, with high values of intraclass coefficient correlation (0.96–0.99). Basic activities of daily living and instrumental activities of daily living presented high correlations with RPE measures (0.75–0.82), whereas performance-based tests presented moderate correlations (0.47–0.59). RPE responses explained the most variance in identifying dependence in self-care activities and presented high diagnostic accuracy to differentiate dependent from independent older women. So the hypotheses had been confirmed that RPE responses in constant-load exercise are better predictors of dependence in self-care activities than performance-based tests. Conclusions: RPE of constant-load physical tasks was valid, reliable, and accurate in identifying dependence in performing self-care activities in older women; therefore, it is possible to use the perceived exertion to identify dependence in performing activities of daily living in older women.
- 1 October 2018
- Published by Taylor & Francis in Experimental Aging Research
- Vol. 44 (5) , 397-410
Validity, Reliability, and Diagnostic Accuracy of Ratings of Perceived Exertion to Identify Dependence in Performing Self-care Activities in Older Women
Background: Dependence in self-care activities among older women has been previously evaluated through performance-based tests. However, these tests have presented inability to accurately distinguish between dependent and independent older adults in performing activities of daily living. Aim: To examine the validity, reliability, and diagnostic accuracy of rating of perceived exertion (RPE) to identify dependence in performing self-care activities in older women. Methods: Thirty-five older women performed two different constant-load tasks (walking on treadmill at 4 km/h for five minutes and arm curls with two kg for one minute), reporting RPE at the end, in four sessions. Performance-based tests (30-second chair stand and 6-minute walk) were also evaluated. Katz Index and Lawton and Brody questionnaires were applied to evaluate the dependence level in performing basic and instrumental activities of daily living. Results: RPE was greater on the first session (RPE 14 ± 2) than second session (RPE 13 ± 2), while it was similar through other sessions, with high values of intraclass coefficient correlation (0.96–0.99). Basic activities of daily living and instrumental activities of daily living presented high correlations with RPE measures (0.75–0.82), whereas performance-based tests presented moderate correlations (0.47–0.59). RPE responses explained the most variance in identifying dependence in self-care activities and presented high diagnostic accuracy to differentiate dependent from independent older women. So the hypotheses had been confirmed that RPE responses in constant-load exercise are better predictors of dependence in self-care activities than performance-based tests. Conclusions: RPE of constant-load physical tasks was valid, reliable, and accurate in identifying dependence in performing self-care activities in older women; therefore, it is possible to use the perceived exertion to identify dependence in performing activities of daily living in older women.
- 1 September 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (9) , 095001
A neutral wind instrument for nano-satellite platforms
Here we describe the first neutral wind sensor developed specifically for use on resource limited nano-satellite platforms. The instrument is a next generation redesign of the ram wind sensor flown on the Communications/Navigation Outage Forecasting System satellite for measurements of neutral velocity, temperature, and composition. Results of subsystem tests in vacuum conditions show low-power operation, promising design, and good resolution of measured parameters over the operational pressure and energy ranges expected in the low Earth orbit environment.
- 1 September 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (9) , 095001
A neutral wind instrument for nano-satellite platforms
Here we describe the first neutral wind sensor developed specifically for use on resource limited nano-satellite platforms. The instrument is a next generation redesign of the ram wind sensor flown on the Communications/Navigation Outage Forecasting System satellite for measurements of neutral velocity, temperature, and composition. Results of subsystem tests in vacuum conditions show low-power operation, promising design, and good resolution of measured parameters over the operational pressure and energy ranges expected in the low Earth orbit environment.
- 1 December 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 86 (12) , 124501
A versatile retarding potential analyzer for nano-satellite platforms
The design of the first retarding potential analyzer (RPA) built specifically for use on resource-limited cubesat platforms is described. The size, mass, and power consumption are consistent with the limitations of a nano-satellite, but the performance specifications are commensurate with those of RPAs flown on much larger platforms. The instrument is capable of measuring the ion density, temperature, and the ram component of the ion velocity in the spacecraft reference frame, while also providing estimates of the ion composition. The mechanical and electrical designs are described, as are the operating modes, command and data structure, and timing scheme. Test data obtained using an ion source inside a laboratory vacuum chamber are presented to validate the performance of the new design.
- 1 December 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 86 (12) , 124501
A versatile retarding potential analyzer for nano-satellite platforms
The design of the first retarding potential analyzer (RPA) built specifically for use on resource-limited cubesat platforms is described. The size, mass, and power consumption are consistent with the limitations of a nano-satellite, but the performance specifications are commensurate with those of RPAs flown on much larger platforms. The instrument is capable of measuring the ion density, temperature, and the ram component of the ion velocity in the spacecraft reference frame, while also providing estimates of the ion composition. The mechanical and electrical designs are described, as are the operating modes, command and data structure, and timing scheme. Test data obtained using an ion source inside a laboratory vacuum chamber are presented to validate the performance of the new design.