Youichi Machida
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Youichi Machida has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Mitsuhiro Tozaki
Kameda Kyobashi Clinic
2 shared publicationsTamiko Yoshida
Kameda Kyobashi Clinic
2 shared publicationsA. Toriihara
1 shared publicationAi Saita
Kameda Kyobashi Clinic
1 shared publicationAkiko Shimauchi
Kameda Kyobashi Clinic
1 shared publicationAkira Takemoto
Tokyo Medical and Dental University Graduate School
1 shared publication
Latest Publications
- 18 March 2015
- Published by Springer Nature in Breast Cancer
- Vol. 22 (3) , 253-261
Breast density: the trend in breast cancer screening
The primary modality for breast cancer screening is mammography. Recent investigations, however, have indicated that an insufficient number of life-threatening cases have been detected by mammography while mammography can often results in a large number of overdiagnoses. To make breast cancer screening more effective, potential factors that influence screening efficacy need to be elucidated. Breast density is one of limiting factors for breast cancer detection using mammography. In this article, influence of breast density on breast screening is explained. Current topics related to breast density, objective assessment of breast density using applications, revision of breast composition classification in Breast Imaging-Reporting and Data System Mammography fifth edition, and legislative movement regarding breast density in the United States, are also mentioned in this review article.
- 18 March 2015
- Published by Springer Nature in Breast Cancer
- Vol. 22 (3) , 253-261
Breast density: the trend in breast cancer screening
The primary modality for breast cancer screening is mammography. Recent investigations, however, have indicated that an insufficient number of life-threatening cases have been detected by mammography while mammography can often results in a large number of overdiagnoses. To make breast cancer screening more effective, potential factors that influence screening efficacy need to be elucidated. Breast density is one of limiting factors for breast cancer detection using mammography. In this article, influence of breast density on breast screening is explained. Current topics related to breast density, objective assessment of breast density using applications, revision of breast composition classification in Breast Imaging-Reporting and Data System Mammography fifth edition, and legislative movement regarding breast density in the United States, are also mentioned in this review article.
- 18 May 2014
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 32 (9) , 561-567
Feasibility study of a breast density measurement within a direct photon-counting mammography scanner system
To evaluate the clinical feasibility of breast density measurements by a new application within a direct photon-counting mammography scanner system. A retrospective study of consecutive women who underwent mammography using a direct photon-counting mammography scanner system (MicroDose mammography SI; Philips Digital Mammography Sweden AB) was performed at the authors’ institution between September and December 2013. Quantitative volumetric glandularity measurements were performed automatically for each acquired mammographic image using an application (Breast Density Measurement; Philips Digital Mammography Sweden AB). The quantitative volumetric glandularity of each breast was defined as the average values for the mediolateral oblique (MLO) and craniocaudal (CC) mammogram views. Of the 44 women who underwent bilateral mammogram acquisitions, the breast density measurements were performed successfully in 40 patients (90.9 %). A very good to excellent correlation in the quantitative breast density measurements acquired from the MLO and CC images was obtained in the 40 evaluable patients (R = 0.99). The calculated volumetric glandularity using this new application should correspond well with the true volumetric density of each breast.
- 18 May 2014
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 32 (9) , 561-567
Feasibility study of a breast density measurement within a direct photon-counting mammography scanner system
To evaluate the clinical feasibility of breast density measurements by a new application within a direct photon-counting mammography scanner system. A retrospective study of consecutive women who underwent mammography using a direct photon-counting mammography scanner system (MicroDose mammography SI; Philips Digital Mammography Sweden AB) was performed at the authors’ institution between September and December 2013. Quantitative volumetric glandularity measurements were performed automatically for each acquired mammographic image using an application (Breast Density Measurement; Philips Digital Mammography Sweden AB). The quantitative volumetric glandularity of each breast was defined as the average values for the mediolateral oblique (MLO) and craniocaudal (CC) mammogram views. Of the 44 women who underwent bilateral mammogram acquisitions, the breast density measurements were performed successfully in 40 patients (90.9 %). A very good to excellent correlation in the quantitative breast density measurements acquired from the MLO and CC images was obtained in the 40 evaluable patients (R = 0.99). The calculated volumetric glandularity using this new application should correspond well with the true volumetric density of each breast.
- 18 May 2013
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 31 (9) , 623-626
Adrenal cortical adenoma arising from an adrenohepatic union
Although the observation of an adrenohepatic union is not a rare occurrence during autopsies, cases associated with this clinical entity are rarely described. We report a case with an adrenal cortical adenoma arising from adrenohepatic union tissue in a patient with a past history of a liver mass.
- 18 May 2013
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 31 (9) , 623-626
Adrenal cortical adenoma arising from an adrenohepatic union
Although the observation of an adrenohepatic union is not a rare occurrence during autopsies, cases associated with this clinical entity are rarely described. We report a case with an adrenal cortical adenoma arising from adrenohepatic union tissue in a patient with a past history of a liver mass.
- 1 January 2013
- Published by Elsevier in European Journal of Surgical Oncology
- Vol. 39 (1) , 26-30
Diagnostic performance of fluorodeoxyglucose-positron emission tomography/computed tomography combined with ultrasonography-guided fine needle aspiration cytology for identifying axillary lymph node status in patients with breast cancer
- 1 January 2013
- Published by Elsevier in European Journal of Surgical Oncology
- Vol. 39 (1) , 26-30
Diagnostic performance of fluorodeoxyglucose-positron emission tomography/computed tomography combined with ultrasonography-guided fine needle aspiration cytology for identifying axillary lymph node status in patients with breast cancer
- 3 April 2012
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 26 (5) , 426-435
Evaluation of sequential FDG-PET/CT for monitoring bone metastasis of breast cancer during therapy: correlation between morphological and metabolic changes with tumor markers
The purpose of this study was to clarify the significance of positron emission tomography (PET) and computed tomography (CT) findings for evaluating the bone metastasis of breast cancer during therapy. Forty-seven patients with bone metastases from breast cancer who underwent sequential FDG-PET/CT studies during therapy were enrolled. A total of 771 lesions were identified. The changes in the PET and CT findings were compared with the tumor marker levels in each patient by calculating the weighted kappa value. The correlation between the PET and CT findings was examined for each lesion by an adjusted Chi-square test. The change in the tumor marker levels was substantially correlated with the PET findings and moderately correlated with the CT findings (weighted kappa = 0.780 and 0.585 for quadratic weighting, respectively). An increase in FDG uptake was correlated with lytic changes on the CT images (62/65, 95.4 %, p < 0.05). Sclerotic changes suggested improvement, but sclerosis and progression occurred at the same time in some lesions. Changes of FDG uptake are useful for evaluating individual bone metastases in cases of breast cancer during therapy. Lytic change on CT images suggests progression of bone metastasis. The lysis-progression/sclerosis-improvement pattern was observed in the majority of subjects, but a sclerosis-progression pattern was also observed. The hybrid pattern of increase of FDG uptake on PET/lytic change on CT is most accurate to show progression of bone metastases. Assessments of these processes during therapy are necessary for the precise evaluation of bone metastases.
- 3 April 2012
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 26 (5) , 426-435
Evaluation of sequential FDG-PET/CT for monitoring bone metastasis of breast cancer during therapy: correlation between morphological and metabolic changes with tumor markers
The purpose of this study was to clarify the significance of positron emission tomography (PET) and computed tomography (CT) findings for evaluating the bone metastasis of breast cancer during therapy. Forty-seven patients with bone metastases from breast cancer who underwent sequential FDG-PET/CT studies during therapy were enrolled. A total of 771 lesions were identified. The changes in the PET and CT findings were compared with the tumor marker levels in each patient by calculating the weighted kappa value. The correlation between the PET and CT findings was examined for each lesion by an adjusted Chi-square test. The change in the tumor marker levels was substantially correlated with the PET findings and moderately correlated with the CT findings (weighted kappa = 0.780 and 0.585 for quadratic weighting, respectively). An increase in FDG uptake was correlated with lytic changes on the CT images (62/65, 95.4 %, p < 0.05). Sclerotic changes suggested improvement, but sclerosis and progression occurred at the same time in some lesions. Changes of FDG uptake are useful for evaluating individual bone metastases in cases of breast cancer during therapy. Lytic change on CT images suggests progression of bone metastasis. The lysis-progression/sclerosis-improvement pattern was observed in the majority of subjects, but a sclerosis-progression pattern was also observed. The hybrid pattern of increase of FDG uptake on PET/lytic change on CT is most accurate to show progression of bone metastases. Assessments of these processes during therapy are necessary for the precise evaluation of bone metastases.