Petro Moilanen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Petro Moilanen has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Jussi Timonen
University of Jyväskylä Department of Physics and Department of Health Sciences Jyväskylä FI-40014, Finland
5 shared publicationsSulin Cheng
University of Jyväskylä Department of Physics and Department of Health Sciences Jyväskylä FI-40014, Finland
5 shared publicationsMaryline Talmant
Université Pierre et Marie Curie - Paris 6 Laboratoire d’Imagerie Paramétrique UMR7623 Paris F-75005, France and , Paris F-75005, France
3 shared publications- Pascal Laugier
Sorbonne Universités, UPMC Univ Paris 06, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale (LIB), 15 rue de l'école de médecine, 75006, Paris, France
3 shared publications Vantte Kilappa
University of Jyväskylä Department of Physics and Department of Health Sciences Jyväskylä FI-40014, Finland
3 shared publicationsJ. Timonen
Department of Physics,University of Jyväskylä, Jyväskylä, Finland
2 shared publications
Latest Publications
- 1 October 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 124 (4) , 2364-2373
Modeling the impact of soft tissue on axial transmission measurements of ultrasonic guided waves in human radius
Recent in vitro and simulation studies have shown that guided waves measured at low ultrasound frequencies (f=200 kHz) can characterize both material properties and geometry of the cortical bone wall. In particular, a method for an accurate cortical thickness estimation from ultrasound velocity data has been presented. The clinical application remains, however, a challenge as the impact of a layer of soft tissue on top of the bone is not yet well established, and this layer is expected to affect the dispersion and relative intensities of guided modes. The present study is focused on the theoretical modeling of the impact of an overlying soft tissue. A semianalytical method and finite-difference time domain simulations were used. The models developed were shown to predict consistently real in vivo data on human radii. As a conclusion, clinical guided wave data are not consistent with in vitro data or related in vitro models, but use of an adequate in vivo model, such as the one introduced here, is necessary. A theoretical model that accounts for the impact of an overlying soft tissue could thus be used in clinical applications.
- 1 October 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 124 (4) , 2364-2373
Modeling the impact of soft tissue on axial transmission measurements of ultrasonic guided waves in human radius
Recent in vitro and simulation studies have shown that guided waves measured at low ultrasound frequencies (f=200 kHz) can characterize both material properties and geometry of the cortical bone wall. In particular, a method for an accurate cortical thickness estimation from ultrasound velocity data has been presented. The clinical application remains, however, a challenge as the impact of a layer of soft tissue on top of the bone is not yet well established, and this layer is expected to affect the dispersion and relative intensities of guided modes. The present study is focused on the theoretical modeling of the impact of an overlying soft tissue. A semianalytical method and finite-difference time domain simulations were used. The models developed were shown to predict consistently real in vivo data on human radii. As a conclusion, clinical guided wave data are not consistent with in vitro data or related in vitro models, but use of an adequate in vivo model, such as the one introduced here, is necessary. A theoretical model that accounts for the impact of an overlying soft tissue could thus be used in clinical applications.
- 3 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 55 (6) , 1277-1286
Ultrasonic guided waves in bone
Recent progress in quantitative ultrasound (QUS) has shown increasing interest toward measuring long bones by ultrasonic guided waves. This technology is widely used in the field of nondestructive testing and evaluation of different waveguide structures. Cortical bone provides such an elastic waveguide and its ability to sustain loading and resist fractures is known to be related to its mechanical properties at different length scales. Because guided waves could yield diverse characterizations of the bone's mechanical properties at the macroscopic level, the method of guided waves has a strong potential over the standardized bone densitometry as a tool for bone assessment. Despite this, development of guided wave methods is challenging, e.g., due to interferences and rnultiparametric inversion problems. This paper discusses the promises and challenges related to bone characterization by ultrasonic guided waves.
- 3 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 55 (6) , 1277-1286
Ultrasonic guided waves in bone
Recent progress in quantitative ultrasound (QUS) has shown increasing interest toward measuring long bones by ultrasonic guided waves. This technology is widely used in the field of nondestructive testing and evaluation of different waveguide structures. Cortical bone provides such an elastic waveguide and its ability to sustain loading and resist fractures is known to be related to its mechanical properties at different length scales. Because guided waves could yield diverse characterizations of the bone's mechanical properties at the macroscopic level, the method of guided waves has a strong potential over the standardized bone densitometry as a tool for bone assessment. Despite this, development of guided wave methods is challenging, e.g., due to interferences and rnultiparametric inversion problems. This paper discusses the promises and challenges related to bone characterization by ultrasonic guided waves.
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3634
Array transducer applied to low-frequency guided wave ultrasonography: An in vivo study on human radius and tibia
Velocity (V FAS ) of a first arriving signal for f < 0.5 MHz is expected to have an enhanced sensitivity to endosteal osteoporotic changes as compared to using higher frequencies. In this study a group of males and females (aged 10‐87 years) was measured by using a new array probe (f c = 0.4 MHz) on the radius and tibia. In addition, peripheral quantitative computed tomography was used to assess the bone mineral density (BMD) and cortical thickness (CTh) at the same bone locations. Initial results (n=57) showed that the repeatability error of the V FAS data (CV rms ) was 0.5%. When V FAS data for the radius was plotted by age it characterized well, yet better than BMD or CTh, the typical growth and loss curve of bone. V FAS for the radius was strongly correlated with total BMD (r = 0.84, p < 0.001), cortical BMD (r = 0.77, p < 0.001), subcortical BMD (r = 0.66, p < 0.001) and CTh (r = 0.59, p < 0.001). Corresponding results for the tibia were similar but clearly weaker than those for the radius. In conclusion, the low‐frequency V FAS had good accuracy and it predicted well both the geometry and material properties throughout the cortex.
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3634
Array transducer applied to low-frequency guided wave ultrasonography: An in vivo study on human radius and tibia
Velocity (V FAS ) of a first arriving signal for f < 0.5 MHz is expected to have an enhanced sensitivity to endosteal osteoporotic changes as compared to using higher frequencies. In this study a group of males and females (aged 10‐87 years) was measured by using a new array probe (f c = 0.4 MHz) on the radius and tibia. In addition, peripheral quantitative computed tomography was used to assess the bone mineral density (BMD) and cortical thickness (CTh) at the same bone locations. Initial results (n=57) showed that the repeatability error of the V FAS data (CV rms ) was 0.5%. When V FAS data for the radius was plotted by age it characterized well, yet better than BMD or CTh, the typical growth and loss curve of bone. V FAS for the radius was strongly correlated with total BMD (r = 0.84, p < 0.001), cortical BMD (r = 0.77, p < 0.001), subcortical BMD (r = 0.66, p < 0.001) and CTh (r = 0.59, p < 0.001). Corresponding results for the tibia were similar but clearly weaker than those for the radius. In conclusion, the low‐frequency V FAS had good accuracy and it predicted well both the geometry and material properties throughout the cortex.
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3631
Ultrasonic guided waves in bone
Recent progress in quantitative ultrasound (QUS) has shown increasing interest towards measuring long bones by ultrasonicguided waves. This technology is widely used in the field of non‐destructive testing and evaluation of different waveguide structures. Cortical bone provides such an elastic waveguide and its ability to sustain loading and resist fractures is known to relate to its mechanical properties at different length scales. As guided waves could yield diverse characterization of bone's mechanical properties at the macroscopic level, the method of guided waves has a strong potential over the standardized bone densitometry as a tool for bone assessment. Despite this, development of guided wave methods is challenging, e.g., due to interferences and multiparametric inversion problem. This paper discusses the promises and challenges related to bones characterization by ultrasonicguided waves.
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3631
Ultrasonic guided waves in bone
Recent progress in quantitative ultrasound (QUS) has shown increasing interest towards measuring long bones by ultrasonicguided waves. This technology is widely used in the field of non‐destructive testing and evaluation of different waveguide structures. Cortical bone provides such an elastic waveguide and its ability to sustain loading and resist fractures is known to relate to its mechanical properties at different length scales. As guided waves could yield diverse characterization of bone's mechanical properties at the macroscopic level, the method of guided waves has a strong potential over the standardized bone densitometry as a tool for bone assessment. Despite this, development of guided wave methods is challenging, e.g., due to interferences and multiparametric inversion problem. This paper discusses the promises and challenges related to bones characterization by ultrasonicguided waves.
- 1 October 2007
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 122 (4) , 2439-2445
Ultrasonically determined thickness of long cortical bones: Three-dimensional simulations of in vitro experiments
It was reported in a previous study that simulated guided wave axial transmission velocities on two-dimensional (2D) numerically reproduced geometry of long bones predicted moderately real in vitro ultrasound data on the same bone samples. It was also shown that fitting of ultrasound velocity with simple analytical model yielded a precise estimate (UTh) for true cortical bone thickness. This current study expands the 2D bone model into three dimensions (3D). To this end, wave velocities and UTh were determined from experiments and from time-domain finite-difference simulations of wave propagation, both performed on a collection of 10 human radii (29 measurement sites). A 3D numerical bone model was developed with tuneable fixed material properties and individualized geometry based on X-ray computed tomography reconstructions of real bones. Simulated UTh data were in good accordance (root-mean-square error was 0.40 mm; r(2)=0.79, p<0.001) with true cortical thickness, and hence the measured phase velocity can be well estimated by using a simple analytical inversion model also in 3D. Prediction of in vitro data was improved significantly (by 10% units) and the upgraded bone model thus explained most of the variability (up to 95% when sites were carefully matched) observed in in vitro ultrasound data.
- 1 October 2007
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 122 (4) , 2439-2445
Ultrasonically determined thickness of long cortical bones: Three-dimensional simulations of in vitro experiments
It was reported in a previous study that simulated guided wave axial transmission velocities on two-dimensional (2D) numerically reproduced geometry of long bones predicted moderately real in vitro ultrasound data on the same bone samples. It was also shown that fitting of ultrasound velocity with simple analytical model yielded a precise estimate (UTh) for true cortical bone thickness. This current study expands the 2D bone model into three dimensions (3D). To this end, wave velocities and UTh were determined from experiments and from time-domain finite-difference simulations of wave propagation, both performed on a collection of 10 human radii (29 measurement sites). A 3D numerical bone model was developed with tuneable fixed material properties and individualized geometry based on X-ray computed tomography reconstructions of real bones. Simulated UTh data were in good accordance (root-mean-square error was 0.40 mm; r(2)=0.79, p<0.001) with true cortical thickness, and hence the measured phase velocity can be well estimated by using a simple analytical inversion model also in 3D. Prediction of in vitro data was improved significantly (by 10% units) and the upgraded bone model thus explained most of the variability (up to 95% when sites were carefully matched) observed in in vitro ultrasound data.
- 1 September 2007
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 122 (3) , 1818-1826
Ultrasonically determined thickness of long cortical bones: Two-dimensional simulations ofin vitroexperiments
Previously it has been demonstrated that cortical bone thickness can be estimated from ultrasonic guided-wave measurements, in an axial transmission configuration, together with an appropriate analytical model. This study considers the impact of bone thickness variation within the measurement region on the ultrasonically determined thickness (UTh). To this end, wave velocities and UTh were determined from experiments and from time-domain finite-difference simulations of wave propagation, both performed on a set of ten human radius specimens (29 measurement sites). A two-dimensional numerical bone model was developed with tunable material properties and individualized geometry based on x-ray computed-tomography reconstructions of human radius. Cortical thickness (CTh) was determined from the latter. UTh data for simulations were indeed in a excellent accordance (root-mean-square error was 0.26mm; r2=0.94, p<0.001) with average CTh within the measurement region. These results indicate that despite variations in cortical thickness along the propagation path, the measured phase velocity can be satisfactorily modeled by a simple analytical model (the A0 plate mode in this case). Most of the variability (up to 85% when sites were carefully matched) observed in the in vitro ultrasound data was explained through simulations by variability in the cortical thickness alone.
- 1 September 2007
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 122 (3) , 1818-1826
Ultrasonically determined thickness of long cortical bones: Two-dimensional simulations ofin vitroexperiments
Previously it has been demonstrated that cortical bone thickness can be estimated from ultrasonic guided-wave measurements, in an axial transmission configuration, together with an appropriate analytical model. This study considers the impact of bone thickness variation within the measurement region on the ultrasonically determined thickness (UTh). To this end, wave velocities and UTh were determined from experiments and from time-domain finite-difference simulations of wave propagation, both performed on a set of ten human radius specimens (29 measurement sites). A two-dimensional numerical bone model was developed with tunable material properties and individualized geometry based on x-ray computed-tomography reconstructions of human radius. Cortical thickness (CTh) was determined from the latter. UTh data for simulations were indeed in a excellent accordance (root-mean-square error was 0.26mm; r2=0.94, p<0.001) with average CTh within the measurement region. These results indicate that despite variations in cortical thickness along the propagation path, the measured phase velocity can be satisfactorily modeled by a simple analytical model (the A0 plate mode in this case). Most of the variability (up to 85% when sites were carefully matched) observed in the in vitro ultrasound data was explained through simulations by variability in the cortical thickness alone.
- 1 February 2007
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 33 (2) , 254-262
Assessment of the cortical bone thickness using ultrasonic guided waves: Modelling and in vitro study
- 1 February 2007
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 33 (2) , 254-262
Assessment of the cortical bone thickness using ultrasonic guided waves: Modelling and in vitro study
- 1 May 2006
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 32 (5) , 709-719
Measuring guided waves in long bones: Modeling and experiments in free and immersed plates
- 1 May 2006
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 32 (5) , 709-719
Measuring guided waves in long bones: Modeling and experiments in free and immersed plates
- 1 November 2004
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 30 (11) , 1517-1521
Thickness sensitivity of ultrasound velocity in long bone phantoms
- 1 November 2004
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 30 (11) , 1517-1521
Thickness sensitivity of ultrasound velocity in long bone phantoms
- 15 October 2003
- Published by Springer Nature in Osteoporosis International
- Vol. 14 (12) , 1020-1027
Assessment of the tibia using ultrasonic guided waves in pubertal girls
The purpose of this study was to compare low frequency ultrasonic guided wave measurements with established ultrasound and bone density measurements in terms of their ability to characterize the tibia in pubertal girls. Subjects were 12–14-year-old girls (n=106) who were participating in a calcium and vitamin D intervention study. A prototype low frequency pulse transmission device consisting of a uniaxial scanning mechanism and low frequency transducers orientated perpendicularly to the limb was used to measure two ultrasound velocities in the tibia. The first velocity, V1, was that of the first arriving signal, similar to that measured by existing commercial tibial ultrasound devices. The second velocity, V2, was that of a slower wave propagating at 1,500–2,000 m/s, which has been shown elsewhere to be consistent with the lowest order antisymmetric guided mode in the bone. In addition, commercial ultrasound devices (Omnisense, Sunlight Ltd.; QUS-2, Quidel Corp.) were used to measure the speed of sound (SOS) in the tibia and the radius and attenuation (BUA) in the calcaneus. Cortical bone cross-sectional area (CSA), mineral density (BMD) and cortical thickness (cTh) of the tibia were measured using pQCT, site-matched to the ultrasound measurements. Both V1 and V2 correlated significantly with cortical BMD and with cTh and CSA. On the other hand, tibial SOS correlated with BMD, but not with cTh and CSA. These results indicate that the prototype device using guided waves captures aspects of tibial cortical bone geometry in addition to bone density, thereby potentially offering increased diagnostic information compared to existing tibial ultrasound devices.
- 15 October 2003
- Published by Springer Nature in Osteoporosis International
- Vol. 14 (12) , 1020-1027
Assessment of the tibia using ultrasonic guided waves in pubertal girls
The purpose of this study was to compare low frequency ultrasonic guided wave measurements with established ultrasound and bone density measurements in terms of their ability to characterize the tibia in pubertal girls. Subjects were 12–14-year-old girls (n=106) who were participating in a calcium and vitamin D intervention study. A prototype low frequency pulse transmission device consisting of a uniaxial scanning mechanism and low frequency transducers orientated perpendicularly to the limb was used to measure two ultrasound velocities in the tibia. The first velocity, V1, was that of the first arriving signal, similar to that measured by existing commercial tibial ultrasound devices. The second velocity, V2, was that of a slower wave propagating at 1,500–2,000 m/s, which has been shown elsewhere to be consistent with the lowest order antisymmetric guided mode in the bone. In addition, commercial ultrasound devices (Omnisense, Sunlight Ltd.; QUS-2, Quidel Corp.) were used to measure the speed of sound (SOS) in the tibia and the radius and attenuation (BUA) in the calcaneus. Cortical bone cross-sectional area (CSA), mineral density (BMD) and cortical thickness (cTh) of the tibia were measured using pQCT, site-matched to the ultrasound measurements. Both V1 and V2 correlated significantly with cortical BMD and with cTh and CSA. On the other hand, tibial SOS correlated with BMD, but not with cTh and CSA. These results indicate that the prototype device using guided waves captures aspects of tibial cortical bone geometry in addition to bone density, thereby potentially offering increased diagnostic information compared to existing tibial ultrasound devices.