FMFred W. McLafferty

Fred W. McLafferty

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fred W. McLafferty has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Detection of four oxidation sites in viral prolyl-4-hydroxylase by top-down mass spectrometry

    by Ying Ge, Brian G. Lawhorn, Mariam ElNaggar, Siu Kwan Sze, Tadhg P. Begley, Fred W. McLafferty


  • Open Access

    Secondary and tertiary structures of gaseous protein ions characterized by electron capture dissociation mass spectrometry and photofragment spectroscopy

    by HanBin Oh, Kathrin Breuker, Siu Kwan Sze, Ying Ge, Barry K. Carpenter, Fred W. McLafferty

    Over the last decade a variety of MS measurements, such as H/D exchange, collision cross sections, and electron capture dissociation (ECD), have been used to characterize protein folding in the gas phase, in the absence of solvent. To the extensive data already available on ubiquitin, here photofragmentation of its ECD-reduced (M + nH)(n−1)+• ions shows that only the 6+ to 9+, not the 10+ to 13+ ions, have tertiary noncovalent bonding; this is indicated as hydrogen bonding by the 3,050–3,775 cm−1 photofragment spectrum. ECD spectra and H/D exchange of the 13+ ions are consistent with an all α-helical secondary structure, with the 11+ and 10+ ions sufficiently destabilized to denature small bend regions near the helix termini. In the 8+ and 9+ ions these terminal helical regions are folded over to be antiparallel and noncovalently bonded to part of the central helix, whereas this overlap is extended in the 7+, 6+, and, presumably, 5+ ions to form a highly stable three-helix bundle. Thermal denaturing of the 7+ to 9+ conformers both peels and slides back the outer helices from the central one, but for the 6+ conformer, this instead extends the protein ends away to shrink the three-helix bundle. Thus removal of H2O from a native protein negates hydrophobic interactions, preferentially stabilizes the α-helical secondary structure with direct solvation of additional protons, and increases tertiary interhelix dipole-dipole and hydrogen bonding.


  • Top-down mass spectrometry of a 29-kDa protein for characterization of any posttranslational modification to within one residue

    by Siu Kwan Sze, Ying Ge, HanBin Oh, Fred W. McLafferty

    A mass difference between the measured molecular weight of a protein and that of its DNA-predicted sequence indicates sequence errors and/or posttranslational modifications. In the top-down mass spectrometry approach, the measured molecular ion is dissociated, and these fragment masses are matched against those predicted from the protein sequence to restrict the locations of the errors/modifications. The proportion of the ion9s interresidue bonds that are cleaved determines the specificity of such locations; previously, ubiquitin (76 residues) was the largest for which all such bonds were dissociated. Now, cleavages are achieved for carbonic anhydrase at 250 of the 258 interresidue locations. Cleavages of three spectra would define posttranslational modifications at 235 residues to within one residue. For 24 of the 34 possible phosphorylation sites, the cleavages of one spectrum would delineate exactly all −PO3H substitutions. This result has been achieved with electron-capture dissociation by minimizing the further cleavage of primary product ions and by denaturing the tertiary noncovalent bonding of the molecular ions under a variety of conditions.


  • Automated de novo sequencing of proteins by tandem high-resolution mass spectrometry

    by David M. Horn, Roman A. Zubarev, Fred W. McLafferty

    A de novo sequencing program for proteins is described that uses tandem MS data from electron capture dissociation and collisionally activated dissociation of electrosprayed protein ions. Computer automation is used to convert the fragment ion mass values derived from these spectra into the most probable protein sequence, without distinguishing Leu/Ile. Minimum human input is necessary for the data reduction and interpretation. No extra chemistry is necessary to distinguish N- and C-terminal fragments in the mass spectra, as this is determined from the electron capture dissociation data. With parts-per-million mass accuracy (now available by using higher field Fourier transform MS instruments), the complete sequences of ubiquitin (8.6 kDa) and melittin (2.8 kDa) were predicted correctly by the program. The data available also provided 91% of the cytochrome c (12.4 kDa) sequence (essentially complete except for the tandem MS-resistant region K 13 –V 20 that contains the cyclic heme). Uncorrected mass values from a 6-T instrument still gave 86% of the sequence for ubiquitin, except for distinguishing Gln/Lys. Extensive sequencing of larger proteins should be possible by applying the algorithm to pieces of ≈10-kDa size, such as products of limited proteolysis.


  • Unknown identification using reference mass spectra. Quality evaluation of databases

    by Fred W. McLafferty, Douglas A. Stauffer, Stanton Y. Loh, Chrysotomos Wesdemiotis

    The high success of the "uncertified" mass spectrometry spectral collection started in 1956 demonstrated qualitatively that a partial reference mass spectrum, even one measured routinely, can be of real value. Correct matchings were still possible despite reference errors, which almost never led to close matches that were incorrect. This study shows quantitatively that the number of different compounds, not the number of peaks in a spectrum, is by far the most important determinant of database efficiency for identifying a "global" unknown. A statistical evaluation of matching performance shows that only 6, 12, and 18 peaks in a reference spectrum are 13%, 67%, and 96%, respectively, as valuable as hundreds of peaks. Also, a separately measured second spectrum of the same compound is 50% as valuable as the first. Database expansion that tripled the number of possible wrong answers only reduced the proportion of correct identifications by 5%. Corrections of a mass or abundance error in each of six reference spectra increase the database matching performance by as much as the addition of one spectrum of a new compound. A new "matching quality index" based statistically on these values indicates that the largest database is also by far the most effective for matching unknowns.


  • Efficient sequence analysis of the six gene products (7‐74 kDA) from the escherichia coli thiamin biosynthetic operon by tandem high‐resolution mass spectrometry

    by Neil L. Kelleher, Sean V. Taylor, David Grannis, Cynthia Kinsland, Hsiu‐Ju Chiu, Tadhg P. Begley, Fred W. Mclafferty

    The 105resolving power and MS/MS capabilities of Fourier‐transform mass spectrometry provide electrospray ionization mass spectra containing > 100 molecular and fragment ion mass values of high accuracy. Applying these spectra to the detection and localization of errors and modifications in the DNA‐derived sequences of proteins is illustrated with the thiCEFSGH thiamin biosynthesis operon from Escherichia coli. Direct fragmentation of the multiply‐charged intact protein ions produces large fragment ions covering the entire sequence; further dissociation of these fragment ions provides information on their sequences. For ThiE (23 kDa), the entire sequence was verified in a single spectrum with an accurate (0.3 Da) molecular weight (Mr) value, with confirmation from MS/MS fragment masses. Those for ThiH (46 kDa) showed that the Mr value (1 Da error) represented the protein without the start Met residue. For ThiF (27 kDa), MS/MS localized a sequence discrepancy to a 34 residue peptide. The first 107 residues of ThiC (74 kDa) were shown to be correct, with C‐terminal heterogeneity indicated. For ThiG (predicted Mr = 34 kDa), ESI/FTMS showed two components of 7,310.74 (ThiS) and 26,896.5 Da (ThiG); MS/MS uncovered three reading frame errors and a stop codon for the first protein. MS/MS ions are consistent with 68 fragments predicted by the corrected ThiS/ThiG DNA sequences.