Manfred Mürtz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Manfred Mürtz has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
P. Hering
Institut für Lasermedizin, Universität Düsseldorf, Düsseldorf, Germany
6 shared publicationsD. Halmer
Universität Düsseldorf, Institut für Lasermedizin, Düsseldorf, Germany
2 shared publicationsDaniel Halmer
Institut für Lasermedizin, Heinrich-Heine-Universität Düsseldorf, Universitätsstr. 1, 40225, Düsseldorf, Germany
2 shared publicationsH. Dahnke
Institut für Lasermedizin, Universität Düsseldorf, 40225 Düsseldorf, Germany DE
2 shared publicationsM. Horstjann
Universität Düsseldorf, Institut für Lasermedizin, Düsseldorf, Germany
2 shared publicationsPeter Hering
Institut für Lasermedizin , Heinrich-Heine-Universität Düsseldorf , Universitätsstr. 1, 40225, Düsseldorf, Germany
2 shared publications
Latest Publications
- 28 February 2009
- Published by Springer Nature in Applied Physics B
- Vol. 95 (2) , 281-286
Infrared laser-spectroscopic analysis of 14NO and 15NO in human breath
- 28 February 2009
- Published by Springer Nature in Applied Physics B
- Vol. 95 (2) , 281-286
Infrared laser-spectroscopic analysis of 14NO and 15NO in human breath
- 3 October 2008
- Published by Springer Nature in Applied Physics B
- Vol. 93 (2-3) , 713-723
Magnetic Faraday modulation spectroscopy of the 1–0 band of 14NO and 15NO
- 3 October 2008
- Published by Springer Nature in Applied Physics B
- Vol. 93 (2-3) , 713-723
Magnetic Faraday modulation spectroscopy of the 1–0 band of 14NO and 15NO
- 24 June 2006
- Published by Springer Nature in Applied Physics B
- Vol. 85 (2-3) , 437-443
Online monitoring of ethane traces in exhaled breath with a difference frequency generation spectrometer
- 24 June 2006
- Published by Springer Nature in Applied Physics B
- Vol. 85 (2-3) , 437-443
Online monitoring of ethane traces in exhaled breath with a difference frequency generation spectrometer
- 1 December 2005
- Published by Taylor & Francis in Isotopes in Environmental and Health Studies
- Vol. 41 (4) , 303-311
Time resolved simultaneous detection of14NO and15NO via mid-infrared cavity leak-out spectroscopy
We present a ring-down absorption spectrometer based on a continuous-wave CO laser in the mid-infrared spectral region near λ = 5 μm. Using a linear ring-down cavity (length: 0.5 m) with high reflective mirrors (R = 99.988 %), we observed a noise-equivalent absorption coefficient of 3 × 10−10 cm−1Hz−1/2. This corresponds to a noise-equivalent concentration of 800 parts per trillion (ppt) for 14NO and 40 ppt for 15NO in 1 s averaging time. We achieve a time resolution of 1 s which allows time resolved simultaneous detection of the two N isotopes. The δ15N value was obtained with a precision of ±1.2‰ in a sample with a NO fraction of 11 ppm. The simultaneous detection enables the use of 15NO as a tracer molecule for endogenous biomedical processes.
- 1 December 2005
- Published by Taylor & Francis in Isotopes in Environmental and Health Studies
- Vol. 41 (4) , 303-311
Time resolved simultaneous detection of14NO and15NO via mid-infrared cavity leak-out spectroscopy
We present a ring-down absorption spectrometer based on a continuous-wave CO laser in the mid-infrared spectral region near λ = 5 μm. Using a linear ring-down cavity (length: 0.5 m) with high reflective mirrors (R = 99.988 %), we observed a noise-equivalent absorption coefficient of 3 × 10−10 cm−1Hz−1/2. This corresponds to a noise-equivalent concentration of 800 parts per trillion (ppt) for 14NO and 40 ppt for 15NO in 1 s averaging time. We achieve a time resolution of 1 s which allows time resolved simultaneous detection of the two N isotopes. The δ15N value was obtained with a precision of ±1.2‰ in a sample with a NO fraction of 11 ppm. The simultaneous detection enables the use of 15NO as a tracer molecule for endogenous biomedical processes.
- 1 February 2004
- Published by Springer Nature in Applied Physics B
- Vol. 78 (3) , 513-517
Online monitoring of biogenic nitric oxide with a QC laser-based Faraday modulation technique
- 1 February 2004
- Published by Springer Nature in Applied Physics B
- Vol. 78 (3) , 513-517
Online monitoring of biogenic nitric oxide with a QC laser-based Faraday modulation technique
- Open Access
- 1 December 2003
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 95 (6) , 2583-2590
Online recording of ethane traces in human breath via infrared laser spectroscopy
A method is described for rapidly measuring the ethane concentration in exhaled human breath. Ethane is considered a volatile marker for lipid peroxidation. The breath samples are analyzed in real time during single exhalations by means of infrared cavity leak-out spectroscopy. This is an ultrasensitive laser-based method for the analysis of trace gases on the sub-parts per billion level. We demonstrate that this technique is capable of online quantifying of ethane traces in exhaled human breath down to 500 parts per trillion with a time resolution of better than 800 ms. This study includes what we believe to be the first measured expirograms for trace fractions of ethane. The expirograms were recorded after a controlled inhalation exposure to 1 part per million of ethane. The normalized slope of the alveolar plateau was determined, which shows a linear increase over the first breathing cycles and ends in a mean value between 0.21 and 0.39 liter-1. The washout process was observed for a time period of 30 min and was modelled by a threefold exponential decay function, with decay times ranging from 12 to 24, 341 to 481, and 370 to 1,770 s. Our analyzer provides a promising noninvasive tool for online monitoring of the oxidative stress status.
- 1 December 2003
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 95 (6) , 2583-2590
Open AccessOnline recording of ethane traces in human breath via infrared laser spectroscopy
A method is described for rapidly measuring the ethane concentration in exhaled human breath. Ethane is considered a volatile marker for lipid peroxidation. The breath samples are analyzed in real time during single exhalations by means of infrared cavity leak-out spectroscopy. This is an ultrasensitive laser-based method for the analysis of trace gases on the sub-parts per billion level. We demonstrate that this technique is capable of online quantifying of ethane traces in exhaled human breath down to 500 parts per trillion with a time resolution of better than 800 ms. This study includes what we believe to be the first measured expirograms for trace fractions of ethane. The expirograms were recorded after a controlled inhalation exposure to 1 part per million of ethane. The normalized slope of the alveolar plateau was determined, which shows a linear increase over the first breathing cycles and ends in a mean value between 0.21 and 0.39 liter-1. The washout process was observed for a time period of 30 min and was modelled by a threefold exponential decay function, with decay times ranging from 12 to 24, 341 to 481, and 370 to 1,770 s. Our analyzer provides a promising noninvasive tool for online monitoring of the oxidative stress status.
- 1 September 2002
- Published by Springer Nature in Applied Physics B
- Vol. 75 (2-3) , 311-316
Rapid formaldehyde monitoring in ambient air by means of mid-infrared cavity leak-out spectroscopy
- 1 September 2002
- Published by Springer Nature in Applied Physics B
- Vol. 75 (2-3) , 311-316
Rapid formaldehyde monitoring in ambient air by means of mid-infrared cavity leak-out spectroscopy
- 1 November 2000
- Published by Optica Publishing Group in Optics Letters
- Vol. 25 (21) , 1606-1608
Real-time detection of ^13CH_4 in ambient air by use of mid-infrared cavity leak-out spectroscopy
We report on spectroscopic real-time detection of in ambient air. Our measurements were carried out by means of cavity leak-out absorption spectroscopy employing a tunable cw laser in the mid-infrared spectral region near . A CO laser in combination with tunable microwave sideband generation was used as the light source. Using a 50-cm-long ringdown cell with mirrors, we achieved a detection limit of 290 parts in (ppt) in ambient air (integration time, 100 s). The corresponding noise-equivalent absorption coefficient was .- 1 November 2000
- Published by Optica Publishing Group in Optics Letters
- Vol. 25 (21) , 1606-1608
Real-time detection of ^13CH_4 in ambient air by use of mid-infrared cavity leak-out spectroscopy
We report on spectroscopic real-time detection of in ambient air. Our measurements were carried out by means of cavity leak-out absorption spectroscopy employing a tunable cw laser in the mid-infrared spectral region near . A CO laser in combination with tunable microwave sideband generation was used as the light source. Using a 50-cm-long ringdown cell with mirrors, we achieved a detection limit of 290 parts in (ppt) in ambient air (integration time, 100 s). The corresponding noise-equivalent absorption coefficient was .