MSMiho Shidahara

Miho Shidahara

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Miho Shidahara has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Improvement of likelihood estimation in Logan graphical analysis using maximum a posteriori for neuroreceptor PET imaging

    by Miho Shidahara, Chie Seki, Mika Naganawa, Muneyuki Sakata, Masatomo Ishikawa, Hiroshi Ito, Iwao Kanno, Kiichi Ishiwata, Yuichi Kimura

    To reduce variance of the total volume of distribution (V T) image, we improved likelihood estimation in graphical analysis (LEGA) for dynamic positron emission tomography (PET) images using maximum a posteriori (MAP).


  • Optimal scan time of oxygen-15-labeled gas inhalation autoradiographic method for measurement of cerebral oxygen extraction fraction and cerebral oxygen metabolic rate

    by Miho Shidahara, Hiroshi Watabe, Kyeong Min Kim, Nobuyuki Kudomi, Hiroshi Ito, Hidehiro Iida

    Regional cerebral blood flow (CBF), cerebral blood volume, oxygen extraction fraction (OEF), and cerebral metabolic rate of oxygen (CMRO2) can be estimated from C15O, H2 15O, and 15O2 tracers and positron emission tomography (PET) using an autoradiographic (ARG) method. Our objective in this study was to optimize the scan time for 15O2 gas study for accurate estimation of OEF and CMRO2. We evaluated statistical noise in OEF by varying the scan time and error caused by the tissue heterogeneity in estimated OEF and CMRO2 using computer simulations. The characteristics of statistical noise were investigated by signal-to-noise (S/N) ratio from repeated tissue time activity curves with noise, which were generated using measured averaged arterial input function and assuming CBF = 20, 50, and 80 (ml/100 g per minute). Error caused by tissue heterogeneity was also investigated by estimated OEF and CMRO2 from tissue time activity curve with mixture of gray and white matter varying fraction of mixture. In the simulations, three conditions were assumed (i) CBF in gray and white matter (CBFg and CBFw) was 80 and 20, OEF in gray and white matter (E g and E w) was 0.4 and 0.3, (ii) CBFg and CBFw decreased by 50%, and E g and E w increased by 50% when compared with conditions (i) and (iii). CBFg and CBFw decreased by 80%, and E g and E w increased by 50% when compared with condition (i). The longer scan time produced the better S/N ratio of estimated OEF value from three CBF values (20, 50, and 80). Errors of estimated OEF for three conditions owing to tissue heterogeneity decreased, as scan time took longer. Meanwhile in the case of CMRO2, 3 min of scan time was desirable. The optimal scan time of 15O2 inhalation study with the ARG method was concluded to be 3 min from taking into account for maintaining the S/N ratio and the quantification of accurate OEF and CMRO2.


  • Wavelet denoising for voxel-based compartmental analysis of peripheral benzodiazepine receptors with 18F-FEDAA1106

    by Miho Shidahara, Yoko Ikoma, Chie Seki, Yota Fujimura, Mika Naganawa, Hiroshi Ito, Tetsuya Suhara, Iwao Kanno, Yuichi Kimura

    We evaluated the noise reduction capability of wavelet denoising for estimated binding potential (BP) images (k 3/k 4) of the peripheral benzodiazepine receptor using 18F-FEDAA1106 and nonlinear least-square fitting.


  • PET kinetic analysis: wavelet denoising of dynamic PET data with application to parametric imaging

    by Miho Shidahara, Yoko Ikoma, Jeff Kershaw, Yuichi Kimura, Mika Naganawa, Hiroshi Watabe

    Physiological functions (e.g., cerebral blood flow, glucose metabolism, and neuroreceptor binding) can be investigated as parameters estimated by kinetic modeling using dynamic positron emission tomography (PET) images. Imaging of these physiological parameters, called parametric imaging, can locate the regional distribution of functionalities. However, the most serious technical issue affecting parametric imaging is noise in dynamic PET data. This review describes wavelet denoising of dynamic PET images for improving image quality in estimated parametric images. Wavelet denoising provides significantly improved quality directly to dynamic PET images and indirectly to estimated parametric images. The application of wavelet denoising to radio-ligand and kinetic analysis is still in the development stage, but even so, it is thought that wavelet techniques will have a substantial impact on nuclear medicine in the near future.


  • Wavelet Denoising of Dynamic PET Data: Application to the Parametric Imaging of Peripheral Benzodiazepine Receptor

    by Miho Shidahara, Yoko Ikoma, Chie Seki, Yota Fujimura, Kin-Ei Yoshida, Hiroshi Ito, Tetsuya Suhara, Iwao Kanno

    Low signal-to-noise ratio (SNR) of time activity curve (TAC) at the voxel level causes severe bias and poor precision for estimated binding potential (BP) in peripheral benzodiazepine receptor (PBR) using nonlinear least square (NLS) fitting. The purpose of this study is to evaluate noise reduction capability of wavelet denoising for estimated BP image. We applied spatial (3D) wavelet denoising to simulate data and clinical dynamic image of PBR using 18F-FEDAA1106. For denoising process, wavelet coefficient for each sub-band was thresholded by soft-threshold method. In simulation study, we generated human mimicked dynamic phantom images and then evaluated the bias of BP from denoised image compared with that from true BP image. In clinical application, BP image with/without wavelet denoising for a subject were compared. Overestimation of BP values was 10~13% in case of noise level 10% of simulation. Wavelet denoising improved overestimated BP values almost a few percent. In clinical, wavelet denoising can compensate the noise in dynamic image, however, difference between BP images of with/without wavelet denoising were not so apparent. Wavelet denoising improve the quality of dynamic images, however, further optimization will be required for improving SNR of BP images.