Jian Rong Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jian Rong Xu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Jia Hua
Department of Radiology, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
2 shared publicationsJian Ying Li
CT Imaging Research Center, GE Healthcare China, Beijing, People’s Republic of China
2 shared publicationsLi Jun Qian
Department of Radiology, Renji Hospital, Shanghai Jiaotong University School of Medicine, No. 1630 Dongfang Rd. Pudong, Shanghai, 200127, People's Republic of China
2 shared publicationsQiang Xia
Department of Hepatic Surgery, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, People’s Republic of China
2 shared publicationsYan Yin
Department of Radiology, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
2 shared publicationsYu Fan Cheng
Liver Transplantation Program, Chang Gung Memorial Hospital–Kaohsiung Medical Center, Chang Gung University College of Medicine, Kaohsiung, Taiwan
2 shared publications
Latest Publications
- Open Access
- 7 May 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (5) , e63140
Optimal Monochromatic Energy Levels in Spectral CT Pulmonary Angiography for the Evaluation of Pulmonary Embolism
The aim of this study was to determine the optimal monochromatic spectral CT pulmonary angiography (sCTPA) levels to obtain the highest image quality and diagnostic confidence for pulmonary embolism detection. The Institutional Review Board of the Shanghai Jiao Tong University School of Medicine approved this study, and written informed consent was obtained from all participating patients. Seventy-two patients with pulmonary embolism were scanned with spectral CT mode in the arterial phase. One hundred and one sets of virtual monochromatic spectral (VMS) images were generated ranging from 40 keV to 140 keV. Image noise, clot diameter and clot to artery contrast-to-noise ratio (CNR) from seven sets of VMS images at selected monochromatic levels in sCTPA were measured and compared. Subjective image quality and diagnostic confidence for these images were also assessed and compared. Data were analyzed by paired t test and Wilcoxon rank sum test. The lowest noise and the highest image quality score for the VMS images were obtained at 65 keV. The VMS images at 65 keV also had the second highest CNR value behind that of 50 keV VMS images. There was no difference in the mean noise and CNR between the 65 keV and 70 keV VMS images. The apparent clot diameter correlated with the keV levels. The optimal energy level for detecting pulmonary embolism using dual-energy spectral CT pulmonary angiography was 65–70 keV. Virtual monochromatic spectral images at approximately 65–70 keV yielded the lowest image noise, high CNR and highest diagnostic confidence for the detection of pulmonary embolism.
- 7 May 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (5) , e63140
Open AccessOptimal Monochromatic Energy Levels in Spectral CT Pulmonary Angiography for the Evaluation of Pulmonary Embolism
The aim of this study was to determine the optimal monochromatic spectral CT pulmonary angiography (sCTPA) levels to obtain the highest image quality and diagnostic confidence for pulmonary embolism detection. The Institutional Review Board of the Shanghai Jiao Tong University School of Medicine approved this study, and written informed consent was obtained from all participating patients. Seventy-two patients with pulmonary embolism were scanned with spectral CT mode in the arterial phase. One hundred and one sets of virtual monochromatic spectral (VMS) images were generated ranging from 40 keV to 140 keV. Image noise, clot diameter and clot to artery contrast-to-noise ratio (CNR) from seven sets of VMS images at selected monochromatic levels in sCTPA were measured and compared. Subjective image quality and diagnostic confidence for these images were also assessed and compared. Data were analyzed by paired t test and Wilcoxon rank sum test. The lowest noise and the highest image quality score for the VMS images were obtained at 65 keV. The VMS images at 65 keV also had the second highest CNR value behind that of 50 keV VMS images. There was no difference in the mean noise and CNR between the 65 keV and 70 keV VMS images. The apparent clot diameter correlated with the keV levels. The optimal energy level for detecting pulmonary embolism using dual-energy spectral CT pulmonary angiography was 65–70 keV. Virtual monochromatic spectral images at approximately 65–70 keV yielded the lowest image noise, high CNR and highest diagnostic confidence for the detection of pulmonary embolism.
- 24 May 2012
- Published by Springer Nature in European Radiology
- Vol. 22 (10) , 2178-2185
Differentiation of neoplastic from bland macroscopic portal vein thrombi using dual-energy spectral CT imaging: a pilot study
Objectives To assess the feasibility and value of dual-energy spectral computed tomography (DESCT) imaging for differentiating neoplastic from bland macroscopic portal vein (PV) thrombi. Methods Computed tomography (CT) images of 44 patients with macroscopic PV thrombus (bland group, n = 16; neoplastic group, n = 28) were reviewed. Iodine-based material decomposition images in the portal venous phase were reconstructed to compare the iodine indices between groups, including thrombus iodine density (I T), thrombus–aorta iodine density ratio (I T/I A), and thrombus–PV iodine density ratio (I T/I P). Differential diagnostic performances of DESCT were calculated in the subgroup of 21 patients with histopathological evidence (bland group, n = 12; neoplastic group, n = 9). Results The iodine indices of the neoplastic group were significantly higher than those in the bland group (P < 0.001). A threshold I T of 1.14 mg/mL, I T/I A of 0.17, and I T/I P of 0.17 in the portal venous phase yielded 100 %, 88.9 %, and 100 % sensitivity, and 91.7 %, 91.7 %, and 83.3 % specificity, respectively, in differentiating neoplastic from bland PV thrombi. Conclusions DESCT imaging with quantification of thrombus iodine density in the portal venous phase appears to be a promising new method for distinguishing neoplastic from bland macroscopic PV thrombi. Key Points • Differentiating the nature of portal vein thrombus is of great clinical significance. • Iodine-based material decomposition imaging reflects iodine distribution after contrast media administration. • Dual-energy CT with iodine quantification can distinguish bland from neoplastic PV thrombi.
- 24 May 2012
- Published by Springer Nature in European Radiology
- Vol. 22 (10) , 2178-2185
Differentiation of neoplastic from bland macroscopic portal vein thrombi using dual-energy spectral CT imaging: a pilot study
Objectives To assess the feasibility and value of dual-energy spectral computed tomography (DESCT) imaging for differentiating neoplastic from bland macroscopic portal vein (PV) thrombi. Methods Computed tomography (CT) images of 44 patients with macroscopic PV thrombus (bland group, n = 16; neoplastic group, n = 28) were reviewed. Iodine-based material decomposition images in the portal venous phase were reconstructed to compare the iodine indices between groups, including thrombus iodine density (I T), thrombus–aorta iodine density ratio (I T/I A), and thrombus–PV iodine density ratio (I T/I P). Differential diagnostic performances of DESCT were calculated in the subgroup of 21 patients with histopathological evidence (bland group, n = 12; neoplastic group, n = 9). Results The iodine indices of the neoplastic group were significantly higher than those in the bland group (P < 0.001). A threshold I T of 1.14 mg/mL, I T/I A of 0.17, and I T/I P of 0.17 in the portal venous phase yielded 100 %, 88.9 %, and 100 % sensitivity, and 91.7 %, 91.7 %, and 83.3 % specificity, respectively, in differentiating neoplastic from bland PV thrombi. Conclusions DESCT imaging with quantification of thrombus iodine density in the portal venous phase appears to be a promising new method for distinguishing neoplastic from bland macroscopic PV thrombi. Key Points • Differentiating the nature of portal vein thrombus is of great clinical significance. • Iodine-based material decomposition imaging reflects iodine distribution after contrast media administration. • Dual-energy CT with iodine quantification can distinguish bland from neoplastic PV thrombi.
- 1 January 2012
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 47 (1) , 85-91
Pulmonary Embolism Detection and Characterization Through Quantitative Iodine-Based Material Decomposition Images With Spectral Computed Tomography Imaging
Objectives: To assess the diagnostic value of pulmonary embolism (PE) detection and characterization through quantitative iodine-based material decomposition images with spectral computed tomography (CT) imaging. Materials and Methods: Fifty-three patients underwent CT pulmonary angiography (CTPA) with spectral imaging mode with the simultaneous acquisition of 80 kVp and 140 kVp on a GE Discovery CT750HD scanner to generate monochromatic CTPA and material decomposition images. CTPA images were reviewed for the presence, localization, and degree (occlusive or nonocclusive) of PE. The iodine distribution in the lung parenchyma on the iodine-based material decomposition images was used to identify perfusion defects, which were then correlated to the CTPA findings. The iodine densities for the perfusion defects and the normal lung parenchyma were measured and statistically compared. Twelve PE patients underwent anticoagulation, and the iodine densities for the perfusion defects before and after the treatment were also measured and compared. The receiver operating characteristics curve was generated to assess the differential diagnostic performances of iodine density in distinguishing the presence or absence of PE and the occlusive or nonocclusive PE. Results: A total of 93 clots (51 occlusive and 42 nonocclusive) were found in 19 patients with lobar (26), segmental (54), or subsegmental (13) distribution. CTPA identified 88 clots initially and 5 more retrospectively with the help of iodine mapping. Thirty-three of 34 normal CTPA patients had symmetric iodine distribution. All occlusive clots and 11 nonocclusive clots showed clear evidence of iodine distribution defects. There was a significant difference for the iodine density among normal lung parenchyma (1.89 mg/mL [0.85–3.29 mg/mL]), nonocclusive perfusion defects (0.83 mg/mL [0.44–1.26 mg/mL]), and occlusive perfusion defects (0.27 mg/mL [0.00–0.62 mg/mL]) (P < 0.001). The iodine densities of perfusion defects before and after anticoagulation were significantly different (P < 0.001). Receiver operating characteristics analyses showed high discriminatory power for using the quantification of iodine density in distinguishing the presence or absence of PE and the occlusive or nonocclusive PE. Conclusions: Spectral CT imaging generated both monochromatic CTPA images for morphologic analysis of PE and material decomposition images for quantitative depiction of pulmonary blood flow and perfusion defects. Quantification of iodine density may be used as a predictor in distinguishing the presence or absence of PE and the severity of PE.
- 1 January 2012
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 47 (1) , 85-91
Pulmonary Embolism Detection and Characterization Through Quantitative Iodine-Based Material Decomposition Images With Spectral Computed Tomography Imaging
Objectives: To assess the diagnostic value of pulmonary embolism (PE) detection and characterization through quantitative iodine-based material decomposition images with spectral computed tomography (CT) imaging. Materials and Methods: Fifty-three patients underwent CT pulmonary angiography (CTPA) with spectral imaging mode with the simultaneous acquisition of 80 kVp and 140 kVp on a GE Discovery CT750HD scanner to generate monochromatic CTPA and material decomposition images. CTPA images were reviewed for the presence, localization, and degree (occlusive or nonocclusive) of PE. The iodine distribution in the lung parenchyma on the iodine-based material decomposition images was used to identify perfusion defects, which were then correlated to the CTPA findings. The iodine densities for the perfusion defects and the normal lung parenchyma were measured and statistically compared. Twelve PE patients underwent anticoagulation, and the iodine densities for the perfusion defects before and after the treatment were also measured and compared. The receiver operating characteristics curve was generated to assess the differential diagnostic performances of iodine density in distinguishing the presence or absence of PE and the occlusive or nonocclusive PE. Results: A total of 93 clots (51 occlusive and 42 nonocclusive) were found in 19 patients with lobar (26), segmental (54), or subsegmental (13) distribution. CTPA identified 88 clots initially and 5 more retrospectively with the help of iodine mapping. Thirty-three of 34 normal CTPA patients had symmetric iodine distribution. All occlusive clots and 11 nonocclusive clots showed clear evidence of iodine distribution defects. There was a significant difference for the iodine density among normal lung parenchyma (1.89 mg/mL [0.85–3.29 mg/mL]), nonocclusive perfusion defects (0.83 mg/mL [0.44–1.26 mg/mL]), and occlusive perfusion defects (0.27 mg/mL [0.00–0.62 mg/mL]) (P < 0.001). The iodine densities of perfusion defects before and after anticoagulation were significantly different (P < 0.001). Receiver operating characteristics analyses showed high discriminatory power for using the quantification of iodine density in distinguishing the presence or absence of PE and the occlusive or nonocclusive PE. Conclusions: Spectral CT imaging generated both monochromatic CTPA images for morphologic analysis of PE and material decomposition images for quantitative depiction of pulmonary blood flow and perfusion defects. Quantification of iodine density may be used as a predictor in distinguishing the presence or absence of PE and the severity of PE.
- 11 August 2009
- Published by Springer Nature in Abdominal Radiology
- Vol. 35 (5) , 522-527
Hemodynamic alterations in anterior segment of liver graft after right-lobe living-donor liver transplantation: computed tomography perfusion imaging findings
Background To identify hemodynamic alterations in anterior segment of liver graft after living-donor liver transplantation (LDLT) using CT perfusion imaging. Methods Perfusion images of 19 recipients 4 weeks after LDLT without reconstruction of the middle hepatic vein (MHV) tributaries were retrospectively identified. According to major MHV tributaries diameter in the right lobe graft, recipients were divided into large (≥5 mm) and small size groups (<5 mm). Blood flow (BF), blood volume (BV), and mean transit time (MTT) of anterior and posterior segments were calculated. Results In large size group, significantly decreased BF (66.98 ± 15.79 mL/min/100 g, corresponded to 37.08%), BV (8.27 ± 2.29 mL/100 g, 41.71%), and increased MTT (11.79 ± 2.10 s, 23.71%) were detected in the anterior segment compared to the posterior segment. In small size group, compared to the posterior segment, BF, BV in the anterior segment decreased 19.12%, 18.48%, respectively, and MTT increased 6.78%, where decreased BF (86.40 ± 21.39 mL/min/100 g) and BV (11.50 ± 2.59 mL/min/100 g) reached statistical significance. Perfusion imbalance in large size group was more remarkable than those in small size group. Conclusions CT liver perfusion imaging enabled quantification of hemodynamic alterations in right-lobe liver graft after LDLT. Compared to small ones, ligation of large MHV tributaries could bring about more marked perfusion imbalance between anterior and posterior segments.
- 11 August 2009
- Published by Springer Nature in Abdominal Radiology
- Vol. 35 (5) , 522-527
Hemodynamic alterations in anterior segment of liver graft after right-lobe living-donor liver transplantation: computed tomography perfusion imaging findings
Background To identify hemodynamic alterations in anterior segment of liver graft after living-donor liver transplantation (LDLT) using CT perfusion imaging. Methods Perfusion images of 19 recipients 4 weeks after LDLT without reconstruction of the middle hepatic vein (MHV) tributaries were retrospectively identified. According to major MHV tributaries diameter in the right lobe graft, recipients were divided into large (≥5 mm) and small size groups (<5 mm). Blood flow (BF), blood volume (BV), and mean transit time (MTT) of anterior and posterior segments were calculated. Results In large size group, significantly decreased BF (66.98 ± 15.79 mL/min/100 g, corresponded to 37.08%), BV (8.27 ± 2.29 mL/100 g, 41.71%), and increased MTT (11.79 ± 2.10 s, 23.71%) were detected in the anterior segment compared to the posterior segment. In small size group, compared to the posterior segment, BF, BV in the anterior segment decreased 19.12%, 18.48%, respectively, and MTT increased 6.78%, where decreased BF (86.40 ± 21.39 mL/min/100 g) and BV (11.50 ± 2.59 mL/min/100 g) reached statistical significance. Perfusion imbalance in large size group was more remarkable than those in small size group. Conclusions CT liver perfusion imaging enabled quantification of hemodynamic alterations in right-lobe liver graft after LDLT. Compared to small ones, ligation of large MHV tributaries could bring about more marked perfusion imbalance between anterior and posterior segments.