Karen G. Schüepp
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Karen G. Schüepp has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Daniel A. Straub
Swiss Paediatric Respiratory Research Group, Division of Respiratory Medicine, University Children's Hospital, Zürich, Switzerland
1 shared publicationHarm A.W.M. Tiddens
Erasmus Medical Center/Sophia Children's Hospital, Rotterdam, The Netherlands
1 shared publicationHettje M. Janssens
Erasmus Medical Center/Sophia Children's Hospital, Rotterdam, The Netherlands
1 shared publicationJohannes H. Wildhaber
Swiss Paediatric Respiratory Research Group, Division of Respiratory Medicine, University Children's Hospital, Zürich, Switzerland
1 shared publicationJuergen Jauernig
PARI Aerosol Research Institute, Munich, Germany
1 shared publicationManfred Keller
PARI Aerosol Research Institute, Munich, Germany
1 shared publication
Latest Publications
- 11 November 2009
- Published by Springer Nature
- p. 211-226
The Potential Harmful and Beneficial Effects of Nanoparticles in Children
- 11 November 2009
- Published by Springer Nature
- p. 211-226
The Potential Harmful and Beneficial Effects of Nanoparticles in Children
- 1 June 2005
- Published by SAGE Publications in Journal of Aerosol Medicine
- Vol. 18 (2) , 225-235
In Vitro Determination of the Optimal Particle Size for Nebulized Aerosol Delivery to Infants
We investigated the in vitro influence of breathing patterns on lung dose (LD) and particle size distribution in an infant upper airway cast model in order to determine the optimal particle size for nebulized aerosol delivery to infants. Budesol (nebulizer solution of budesonide) delivery from a perforated vibrating membrane nebulizer (eFlow® Baby functional prototype) through an upper airway cast of a nine month old infant (SAINT-model) was measured at a fixed respiratory rate (RR) of 30 breaths per minute (bpm) and a tidal volume (Vt) of 50, 100, and 200 mL, respectively, and at a fixed Vt of 100 mL and a RR of 30, 60, and 78 bpm, respectively. LD expressed as a percentage of the nominal dose (ND; range, 5.8–30.3%) decreased with increasing Vt (p < 0.001) and with increasing RR (p < 0.001). Median mass aerodynamic diameter (MMAD) after passage (range, 2.4–3.4 μm) through the upper airway cast showed a negative correlation with increasing Vt (p < 0.001) and with increasing RR (p = 0.015). Particles available as LD for all simulated breathing pattern showed a particle size distribution with a MMAD of 2.4 μm and a geometric standard deviation (GSD) of 1.56. From our in vitro study, we conclude that the optimal particle size for nebulized aerosols for inhalation therapy for infants should have a MMAD of <2.4 μm.
- 1 June 2005
- Published by SAGE Publications in Journal of Aerosol Medicine
- Vol. 18 (2) , 225-235
In Vitro Determination of the Optimal Particle Size for Nebulized Aerosol Delivery to Infants
We investigated the in vitro influence of breathing patterns on lung dose (LD) and particle size distribution in an infant upper airway cast model in order to determine the optimal particle size for nebulized aerosol delivery to infants. Budesol (nebulizer solution of budesonide) delivery from a perforated vibrating membrane nebulizer (eFlow® Baby functional prototype) through an upper airway cast of a nine month old infant (SAINT-model) was measured at a fixed respiratory rate (RR) of 30 breaths per minute (bpm) and a tidal volume (Vt) of 50, 100, and 200 mL, respectively, and at a fixed Vt of 100 mL and a RR of 30, 60, and 78 bpm, respectively. LD expressed as a percentage of the nominal dose (ND; range, 5.8–30.3%) decreased with increasing Vt (p < 0.001) and with increasing RR (p < 0.001). Median mass aerodynamic diameter (MMAD) after passage (range, 2.4–3.4 μm) through the upper airway cast showed a negative correlation with increasing Vt (p < 0.001) and with increasing RR (p = 0.015). Particles available as LD for all simulated breathing pattern showed a particle size distribution with a MMAD of 2.4 μm and a geometric standard deviation (GSD) of 1.56. From our in vitro study, we conclude that the optimal particle size for nebulized aerosols for inhalation therapy for infants should have a MMAD of <2.4 μm.