KSKaren G. Schüepp

Karen G. Schüepp

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Karen G. Schüepp has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Daniel A. Straub

    Swiss Paediatric Respiratory Research Group, Division of Respiratory Medicine, University Children's Hospital, Zürich, Switzerland

    1 shared publication
  • Harm A.W.M. Tiddens

    Erasmus Medical Center/Sophia Children's Hospital, Rotterdam, The Netherlands

    1 shared publication
  • Hettje M. Janssens

    Erasmus Medical Center/Sophia Children's Hospital, Rotterdam, The Netherlands

    1 shared publication
  • Johannes H. Wildhaber

    Swiss Paediatric Respiratory Research Group, Division of Respiratory Medicine, University Children's Hospital, Zürich, Switzerland

    1 shared publication
  • Juergen Jauernig

    PARI Aerosol Research Institute, Munich, Germany

    1 shared publication
  • Manfred Keller

    PARI Aerosol Research Institute, Munich, Germany

    1 shared publication

Latest Publications

  • In Vitro Determination of the Optimal Particle Size for Nebulized Aerosol Delivery to Infants

    by Karen G. Schüepp, Juergen Jauernig, Hettje M. Janssens, Harm A.W.M. Tiddens, Daniel A. Straub, Roland Stangl, Manfred Keller, Johannes H. Wildhaber

    We investigated the in vitro influence of breathing patterns on lung dose (LD) and particle size distribution in an infant upper airway cast model in order to determine the optimal particle size for nebulized aerosol delivery to infants. Budesol (nebulizer solution of budesonide) delivery from a perforated vibrating membrane nebulizer (eFlow® Baby functional prototype) through an upper airway cast of a nine month old infant (SAINT-model) was measured at a fixed respiratory rate (RR) of 30 breaths per minute (bpm) and a tidal volume (Vt) of 50, 100, and 200 mL, respectively, and at a fixed Vt of 100 mL and a RR of 30, 60, and 78 bpm, respectively. LD expressed as a percentage of the nominal dose (ND; range, 5.8–30.3%) decreased with increasing Vt (p < 0.001) and with increasing RR (p < 0.001). Median mass aerodynamic diameter (MMAD) after passage (range, 2.4–3.4 μm) through the upper airway cast showed a negative correlation with increasing Vt (p < 0.001) and with increasing RR (p = 0.015). Particles available as LD for all simulated breathing pattern showed a particle size distribution with a MMAD of 2.4 μm and a geometric standard deviation (GSD) of 1.56. From our in vitro study, we conclude that the optimal particle size for nebulized aerosols for inhalation therapy for infants should have a MMAD of <2.4 μm.