A. Hoffmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
A. Hoffmann has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
A. Delgard
UMR 5221 CNRS-Université de Montpellier 1 Laboratoire Charles Coulomb (L2C) 34095 Montpellier, France
1 shared publicationA. Segovia-Mera
UMR 5221 CNRS-Université de Montpellier 1 Laboratoire Charles Coulomb (L2C) 34095 Montpellier, France
1 shared publication- Andrea Murari
Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova, Italy
1 shared publication B. Chenaud
UMR 5221 CNRS-Université de Montpellier 1 Laboratoire Charles Coulomb (L2C) 34095 Montpellier, France
1 shared publication- B. Sagnes
IES, University of Montpellier, CNRS, Montpellier 34095, France
1 shared publication - Bharat L. Bhuva
Vanderbilt University, Nashville, USA
1 shared publication
Latest Publications
- 5 June 2026
- Published by World Scientific Pub Co Pte Ltd in Fluctuation and Noise Letters
- Vol. 25 (05)
X-Ray Impact on Generation-Recombination Low-Frequency Noise Components for Advanced Si/SiGe:C HBTs
This study presents an investigation of X-ray dose impact on Low-Frequency Noise Generation-Recombination components for NPN Si/SiGe:C heterojunction bipolar transistors (HBTs) developed in two BiCMOS technologies. Generation-Recombination (G-R) components are examined in detail both before and after irradiation. Compact modeling for these excess noise components is established after X-ray exposure. They are studied over the irradiation process as a function of current biases and geometrical parameters to locate the noise sources. A thermal annealing process at two temperatures, 100 ∘ C and 130 ∘ C, is accomplished to investigate any possible healing effects on Low-Frequency Noise spectra.
- 5 June 2026
- Published by World Scientific Pub Co Pte Ltd in Fluctuation and Noise Letters
- Vol. 25 (05)
X-Ray Impact on Generation-Recombination Low-Frequency Noise Components for Advanced Si/SiGe:C HBTs
This study presents an investigation of X-ray dose impact on Low-Frequency Noise Generation-Recombination components for NPN Si/SiGe:C heterojunction bipolar transistors (HBTs) developed in two BiCMOS technologies. Generation-Recombination (G-R) components are examined in detail both before and after irradiation. Compact modeling for these excess noise components is established after X-ray exposure. They are studied over the irradiation process as a function of current biases and geometrical parameters to locate the noise sources. A thermal annealing process at two temperatures, 100 ∘ C and 130 ∘ C, is accomplished to investigate any possible healing effects on Low-Frequency Noise spectra.
- 8 January 2016
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 119 (2) , 024501
Sensitivity and noise of micro-Hall magnetic sensors based on InGaAs quantum wells
We study the room-temperature performance of micro-Hall magnetic sensors based on pseudomorphic InGaAs quantum wells. Active areas of our sensors range from 1 to 80 μm. We focus on the smallest detectable magnetic fields in small sensors and perform a systematic study of noise at room temperature in the frequency range between 1 Hz and 100 kHz. Our data are interpreted by the mobility fluctuation model. The Hooge parameter is determined for the applied technology. We show that, independently of the experimental frequency, the ratio of sensitivity to noise is proportional to characteristic length of the sensor. The resolution of 1 mG/Hz is achievable in a 3μm sensor at room temperature.
- 8 January 2016
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 119 (2) , 024501
Sensitivity and noise of micro-Hall magnetic sensors based on InGaAs quantum wells
We study the room-temperature performance of micro-Hall magnetic sensors based on pseudomorphic InGaAs quantum wells. Active areas of our sensors range from 1 to 80 μm. We focus on the smallest detectable magnetic fields in small sensors and perform a systematic study of noise at room temperature in the frequency range between 1 Hz and 100 kHz. Our data are interpreted by the mobility fluctuation model. The Hooge parameter is determined for the applied technology. We show that, independently of the experimental frequency, the ratio of sensitivity to noise is proportional to characteristic length of the sensor. The resolution of 1 mG/Hz is achievable in a 3μm sensor at room temperature.
- 1 December 1999
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 46 (6) , 1804-1808
Light emission studies of total dose and hot carrier effects on silicon junctions
- 1 December 1999
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 46 (6) , 1804-1808
Light emission studies of total dose and hot carrier effects on silicon junctions
- 1 January 1997
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 68 (1) , 951-954
Signal processing and general purpose data acquisition system for on-line tomographic measurements
New analog signal conditioning electronics and data acquisition systems have been developed for the soft x-ray and bolometric tomography diagnostic in the reverse field pinch experiment (RFX). For the soft x-ray detectors the analog signal processing includes a fully differential current to voltage conversion, with up to a 200 kHz bandwidth. For the bolometers, a 50 kHz carrier frequency amplifier allows a maximum bandwidth of 10 kHz. In both cases the analog signals are digitized with a 1 MHz sampling rate close to the diagnostic and are transmitted via a transparent asynchronous xmitter/receiver interface (TAXI) link to purpose built Versa Module Europa (VME) modules which perform data acquisition. A software library has been developed for data preprocessing and tomographic reconstruction. It has been written in C language and is self-contained, i.e., no additional mathematical library is required. The package is therefore platform-free: in particular it can perform online analysis in a real-time application, such as continuous display and feedback, and is portable for long duration fusion or other physical experiments. Due to the modular organization of the library, new preprocessing and analysis modules can be easily integrated in the environment. This software is implemented in RFX over three different platforms: open VMS, digital Unix, and VME 68040 CPU.
- 1 January 1997
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 68 (1) , 951-954
Signal processing and general purpose data acquisition system for on-line tomographic measurements
New analog signal conditioning electronics and data acquisition systems have been developed for the soft x-ray and bolometric tomography diagnostic in the reverse field pinch experiment (RFX). For the soft x-ray detectors the analog signal processing includes a fully differential current to voltage conversion, with up to a 200 kHz bandwidth. For the bolometers, a 50 kHz carrier frequency amplifier allows a maximum bandwidth of 10 kHz. In both cases the analog signals are digitized with a 1 MHz sampling rate close to the diagnostic and are transmitted via a transparent asynchronous xmitter/receiver interface (TAXI) link to purpose built Versa Module Europa (VME) modules which perform data acquisition. A software library has been developed for data preprocessing and tomographic reconstruction. It has been written in C language and is self-contained, i.e., no additional mathematical library is required. The package is therefore platform-free: in particular it can perform online analysis in a real-time application, such as continuous display and feedback, and is portable for long duration fusion or other physical experiments. Due to the modular organization of the library, new preprocessing and analysis modules can be easily integrated in the environment. This software is implemented in RFX over three different platforms: open VMS, digital Unix, and VME 68040 CPU.