Jiuru Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiuru Lu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Fei Nie
School of Chemistry and Material Science, Shaanxi Normal University, Xi'an 710062, China
7 shared publicationsJianxiu Du
School of Chemistry and Materials Science, Shaanxi Normal University , Xi'an 710062, China
5 shared publicationsYunhua He
School Of Chemistry and Materials Science, Shaanxi Normal University, Xi'an 710062, China
5 shared publications- Mei Liu
College of Food Engineering and Nutritional Science, Shaanxi Normal University, Xi’an 710119, China
2 shared publications Na Feng
School of Chemistry and Materials Science, Shaanxi Normal University, Xi’an, P.R. China
2 shared publicationsYinhuan Li
School of Chemistry and Materials Science, ShaanXi Normal University, Xi'an 710062, People's Republic of China
2 shared publications
Latest Publications
- 4 January 2008
- Published by Wiley in Luminescence
- Vol. 23 (1) , 32-36
Chemiluminescence determination of bromhexine hydrochloride with morin as chemiluminescent reagent
A new chemiluminescence (CL) reaction was observed when cerium(IV) solution was injected into bromhexine hydrochloride–morin solution. Based on this, a flow‐injection CL method for the determination of bromhexine hydrochloride was established. A possible mechanism of the CL reaction was proposed via the investigation of the CL kinetic characteristics, the CL spectrum and the fluorescence spectra of some related substances. Under optimum conditions, the CL signal was correlated linearly with concentration of bromhexine hydrochloride over the range 2.0 × 10–9–2.0 × 10–7 g/mL, with a linear correlation of 0.9995. The detection limit was 9 × 10–10 g/mL bromhexine hydrochloride and the relative standard deviation was 1.0% (c = 2.0 × 10–8 g/mL bromhexine hydrochloride, n = 11). The method was applied to the determination of bromhexine hydrochloride in pharmaceutical preparations and human urine samples with satisfactory results. Copyright © 2008 John Wiley & Sons, Ltd.
- 4 January 2008
- Published by Wiley in Luminescence
- Vol. 23 (1) , 32-36
Chemiluminescence determination of bromhexine hydrochloride with morin as chemiluminescent reagent
A new chemiluminescence (CL) reaction was observed when cerium(IV) solution was injected into bromhexine hydrochloride–morin solution. Based on this, a flow‐injection CL method for the determination of bromhexine hydrochloride was established. A possible mechanism of the CL reaction was proposed via the investigation of the CL kinetic characteristics, the CL spectrum and the fluorescence spectra of some related substances. Under optimum conditions, the CL signal was correlated linearly with concentration of bromhexine hydrochloride over the range 2.0 × 10–9–2.0 × 10–7 g/mL, with a linear correlation of 0.9995. The detection limit was 9 × 10–10 g/mL bromhexine hydrochloride and the relative standard deviation was 1.0% (c = 2.0 × 10–8 g/mL bromhexine hydrochloride, n = 11). The method was applied to the determination of bromhexine hydrochloride in pharmaceutical preparations and human urine samples with satisfactory results. Copyright © 2008 John Wiley & Sons, Ltd.
- 1 December 2007
- Published by Taylor & Francis in Analytical Letters
- Vol. 40 (18) , 3405-3416
Post‐chemiluminescence Method of the Determination of Loperamide Hydrochloride in Human Plasma and Pharmaceutical by Using Dichlorofluorescein as Chemiluminescence Reagent
A post‐chemiluminescence (PCL) was observed when loperamide hydrochloride solution was injected into the reaction mixture after the finish of CL reaction of alkaline N‐Chlorosuccinimide (NCS) and dichlorofluorescein. Based on this phenomenon, a simple, sensitive and fast flow injection PCL method was established for the determination of loperamide hydrochloride. The possible mechanism for the PCL reaction was discussed via the investigation of the CL kinetic characteristics, the CL spectra, the fluorescence spectra. The PCL intensity responded linearly to the concentration of loperamide hydrochloride in the range 8.0×10−10 to 6.0×10−7 g · ml−1 with a linear correlation of 0.9995. The detection limit was 4×10−10 g · ml−1. The relative standard deviation was 2.4% for 4.0×10−8 g · ml−1 loperamide hydrochloride (n=11). This method has been applied to the determination of loperamide hydrochloride in human plasma and pharmaceutical samples with satisfactory results.
- 1 December 2007
- Published by Taylor & Francis in Analytical Letters
- Vol. 40 (18) , 3405-3416
Post‐chemiluminescence Method of the Determination of Loperamide Hydrochloride in Human Plasma and Pharmaceutical by Using Dichlorofluorescein as Chemiluminescence Reagent
A post‐chemiluminescence (PCL) was observed when loperamide hydrochloride solution was injected into the reaction mixture after the finish of CL reaction of alkaline N‐Chlorosuccinimide (NCS) and dichlorofluorescein. Based on this phenomenon, a simple, sensitive and fast flow injection PCL method was established for the determination of loperamide hydrochloride. The possible mechanism for the PCL reaction was discussed via the investigation of the CL kinetic characteristics, the CL spectra, the fluorescence spectra. The PCL intensity responded linearly to the concentration of loperamide hydrochloride in the range 8.0×10−10 to 6.0×10−7 g · ml−1 with a linear correlation of 0.9995. The detection limit was 4×10−10 g · ml−1. The relative standard deviation was 2.4% for 4.0×10−8 g · ml−1 loperamide hydrochloride (n=11). This method has been applied to the determination of loperamide hydrochloride in human plasma and pharmaceutical samples with satisfactory results.
- 4 July 2007
- Published by Wiley in Luminescence
- Vol. 22 (5) , 480-486
Novel chemiluminescence system with calcein as chemiluminescent reagent
Chemiluminescence (CL) was observed when calcein reacted with potassium ferricyanide. Several metal ions and organic compounds could enhance this CL signal. The possible mechanisms for the CL reactions and the enhancement effect were investigated via studies of the CL kinetic characteristics, the CL spectra of some related reactions, the UV absorption spectra and the fluorescence spectra of some substances. The merits of figures for some substances with CL activity were obtained. A new CL system with calcein as the CL reagent was preliminarily established. Copyright © 2007 John Wiley & Sons, Ltd.
- 4 July 2007
- Published by Wiley in Luminescence
- Vol. 22 (5) , 480-486
Novel chemiluminescence system with calcein as chemiluminescent reagent
Chemiluminescence (CL) was observed when calcein reacted with potassium ferricyanide. Several metal ions and organic compounds could enhance this CL signal. The possible mechanisms for the CL reactions and the enhancement effect were investigated via studies of the CL kinetic characteristics, the CL spectra of some related reactions, the UV absorption spectra and the fluorescence spectra of some substances. The merits of figures for some substances with CL activity were obtained. A new CL system with calcein as the CL reagent was preliminarily established. Copyright © 2007 John Wiley & Sons, Ltd.
- 30 April 2007
- Published by Wiley in Luminescence
- Vol. 22 (4) , 326-330
Direct chemiluminescence determination of ibuprofen by the enhancement of the KMnO4–sulphite reaction
A simple, rapid, flow‐injection chemiluminescence (CL) method is described for the determination of ibuprofen. A strong CL signal was detected when a mixture of the analyte and sulphite was injected into acidic KMnO4. The CL signal is proportional to the concentration of ibuprofen in the range 0.1–10.0 mg/L. The detection limit is 0.02 mg/L ibuprofen, the relative standard deviation is 1.8% (0.5 mg/L ibuprofen; n = 11) and the sample measurement frequency is 120/h. The proposed method was successfully applied to the determination of ibuprofen in pharmaceutical preparations and in spiked urine samples. The mechanism of the CL reaction is also discussed. Copyright © 2007 John Wiley & Sons, Ltd.
- 30 April 2007
- Published by Wiley in Luminescence
- Vol. 22 (4) , 326-330
Direct chemiluminescence determination of ibuprofen by the enhancement of the KMnO4–sulphite reaction
A simple, rapid, flow‐injection chemiluminescence (CL) method is described for the determination of ibuprofen. A strong CL signal was detected when a mixture of the analyte and sulphite was injected into acidic KMnO4. The CL signal is proportional to the concentration of ibuprofen in the range 0.1–10.0 mg/L. The detection limit is 0.02 mg/L ibuprofen, the relative standard deviation is 1.8% (0.5 mg/L ibuprofen; n = 11) and the sample measurement frequency is 120/h. The proposed method was successfully applied to the determination of ibuprofen in pharmaceutical preparations and in spiked urine samples. The mechanism of the CL reaction is also discussed. Copyright © 2007 John Wiley & Sons, Ltd.
- 21 June 2006
- Published by Wiley in Luminescence
- Vol. 21 (4) , 251-255
Chemiluminescence flow‐injection analysis of β‐lactam antibiotics using the luminol–permanganate reaction
A new flow injection chemiluminescence (CL) method has been developed for the determination of six β‐lactam antibiotics, including amoxicillin, cefadroxil, cefoperazone sodium, cefazolin sodium, cefradine and ceftriaxone sodium. When the antibiotic was injected into a stream of KMnO4 with alkaline luminol, a strong CL signal was produced. The method allows the measurements of 0.1–50.0 mg/L amoxicillin, 0.1–80.0 mg/L cefadroxil, 1.0–30.0 mg/L cefoperazone sodium, 1.0–30.0 mg/L cefazolin sodium, 3.0–50.0 mg/L cefradine and 3.0–50.0 mg/L ceftriaxone sodium. The detection limits are 0.05 mg/L for amoxycillin, 0.05 mg/L for cefadroxil, 0.4 mg/L for cefoperazonum sodium, 0.4 mg/L for cefazolin sodium, 0.8 mg/L for cefradine and 0.8 mg/L for ceftriaxone sodium. The relative standard deviations in 11 repeated measurements are 0.6%, 0.8%, 1.5%, 1.2%, 0.4% and 0.3% for 3.0 mg/L amoxicillin, 1.0 mg/L cefadroxil, 10.0 mg/L cefoperazone sodium, 10.0 mg/L cefazolin sodium, 10.0 mg/L cefradine and 10.0 mg/L ceftriaxone sodium, respectively. The method was successfully applied to the determination of amoxicillin in pharmaceutical preparations. A possible CL reaction mechanism is also discussed. Copyright © 2006 John Wiley & Sons, Ltd.
- 21 June 2006
- Published by Wiley in Luminescence
- Vol. 21 (4) , 251-255
Chemiluminescence flow‐injection analysis of β‐lactam antibiotics using the luminol–permanganate reaction
A new flow injection chemiluminescence (CL) method has been developed for the determination of six β‐lactam antibiotics, including amoxicillin, cefadroxil, cefoperazone sodium, cefazolin sodium, cefradine and ceftriaxone sodium. When the antibiotic was injected into a stream of KMnO4 with alkaline luminol, a strong CL signal was produced. The method allows the measurements of 0.1–50.0 mg/L amoxicillin, 0.1–80.0 mg/L cefadroxil, 1.0–30.0 mg/L cefoperazone sodium, 1.0–30.0 mg/L cefazolin sodium, 3.0–50.0 mg/L cefradine and 3.0–50.0 mg/L ceftriaxone sodium. The detection limits are 0.05 mg/L for amoxycillin, 0.05 mg/L for cefadroxil, 0.4 mg/L for cefoperazonum sodium, 0.4 mg/L for cefazolin sodium, 0.8 mg/L for cefradine and 0.8 mg/L for ceftriaxone sodium. The relative standard deviations in 11 repeated measurements are 0.6%, 0.8%, 1.5%, 1.2%, 0.4% and 0.3% for 3.0 mg/L amoxicillin, 1.0 mg/L cefadroxil, 10.0 mg/L cefoperazone sodium, 10.0 mg/L cefazolin sodium, 10.0 mg/L cefradine and 10.0 mg/L ceftriaxone sodium, respectively. The method was successfully applied to the determination of amoxicillin in pharmaceutical preparations. A possible CL reaction mechanism is also discussed. Copyright © 2006 John Wiley & Sons, Ltd.
- 18 March 2006
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 385 (1) , 153-160
Investigating the post-chemiluminescence behavior of phenothiazine medications in the luminol–potassium ferricyanide system: molecular imprinting–post-chemiluminescence method for the determination of chlorpromazine hydrochloride
A new post-chemiluminescence (PCL) phenomenon was observed when phenothiazine medications were injected into the reaction mixture after the chemiluminescence (CL) reaction of luminol and potassium ferricyanide had finished. A possible reaction mechanism was proposed based on studies of the kinetic characteristics of the CL, CL spectra, fluorescence spectra, and on other experiments. The feasibility of determining various phenothiazine medications by utilizing these PCL reactions was examined. A molecular imprinting–post-chemiluminescence (MI-PCL) method was established for the determination of chlorpromazine hydrochloride using a chlorpromazine hydrochloride-imprinted polymer (MIP) as the recognition material. The method displayed high selectivity and high sensitivity. The linear range of the method was 1.0×10−8∼1.0×10−6, with a linear correlation coefficient of 0.9985. The detection limit was 3×10−9 g/ml chlorpromazine hydrochloride, and the relative standard deviation for a 1.0×10−7 g/ml chlorpromazine hydrochloride solution was 4.0% (n=11). The method has been applied to the determination of chlorpromazine hydrochloride in urine and animal drinking water with satisfactory results.
- 18 March 2006
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 385 (1) , 153-160
Investigating the post-chemiluminescence behavior of phenothiazine medications in the luminol–potassium ferricyanide system: molecular imprinting–post-chemiluminescence method for the determination of chlorpromazine hydrochloride
A new post-chemiluminescence (PCL) phenomenon was observed when phenothiazine medications were injected into the reaction mixture after the chemiluminescence (CL) reaction of luminol and potassium ferricyanide had finished. A possible reaction mechanism was proposed based on studies of the kinetic characteristics of the CL, CL spectra, fluorescence spectra, and on other experiments. The feasibility of determining various phenothiazine medications by utilizing these PCL reactions was examined. A molecular imprinting–post-chemiluminescence (MI-PCL) method was established for the determination of chlorpromazine hydrochloride using a chlorpromazine hydrochloride-imprinted polymer (MIP) as the recognition material. The method displayed high selectivity and high sensitivity. The linear range of the method was 1.0×10−8∼1.0×10−6, with a linear correlation coefficient of 0.9985. The detection limit was 3×10−9 g/ml chlorpromazine hydrochloride, and the relative standard deviation for a 1.0×10−7 g/ml chlorpromazine hydrochloride solution was 4.0% (n=11). The method has been applied to the determination of chlorpromazine hydrochloride in urine and animal drinking water with satisfactory results.
- Open Access
- 1 September 2005
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 29 (6) , 528-532
Determination of Morphine by Molecular Imprinting-Chemiluminescence Method
A molecular imprinted polymer of morphine was synthesized. Using the imprinted polymer as the recognition material, sodium sulfite as the protective agent, and a potassium permanganatemorphine chemiluminescence system as the detection system, a molecular imprinting-chemiluminescence method for the determination of morphine was established. The linear response range of this method was 5.0 × 10−9–1.0 × 10−6 g/mL (r = 0.9981) and the detection limit was 2 × 10−9 g/mL. The coefficient of variation for 1.0 × 10−7 g/mL morphine solution was 2.8% (n = 9). This method was applied to the determination of morphine in the urine of the heroin abusers with satisfactory results.
- 1 September 2005
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 29 (6) , 528-532
Open AccessDetermination of Morphine by Molecular Imprinting-Chemiluminescence Method
A molecular imprinted polymer of morphine was synthesized. Using the imprinted polymer as the recognition material, sodium sulfite as the protective agent, and a potassium permanganatemorphine chemiluminescence system as the detection system, a molecular imprinting-chemiluminescence method for the determination of morphine was established. The linear response range of this method was 5.0 × 10−9–1.0 × 10−6 g/mL (r = 0.9981) and the detection limit was 2 × 10−9 g/mL. The coefficient of variation for 1.0 × 10−7 g/mL morphine solution was 2.8% (n = 9). This method was applied to the determination of morphine in the urine of the heroin abusers with satisfactory results.
- 1 July 2005
- Published by Elsevier in Analytica Chimica Acta
- Vol. 545 (2) , 129-136
Chemiluminescence determination of indapamide using indapamide-imprinted polymer as recognition material
- 1 July 2005
- Published by Elsevier in Analytica Chimica Acta
- Vol. 545 (2) , 129-136
Chemiluminescence determination of indapamide using indapamide-imprinted polymer as recognition material
- 1 July 2005
- Published by Wiley in Luminescence
- Vol. 20 (4-5) , 266-270
Post‐chemiluminescence behaviour of Ni2+, Mg2+, Cd2+ and Zn2+ in the potassium ferricyanide–luminol reaction
A new chemiluminescence (CL) reaction was observed when Ni2+, Mg2+, Cd2+ or Zn2+ was injected into the reaction mixture after the finish of the CL reaction of alkaline luminol and potassium ferricyanide. This reaction is described as a post‐chemiluminescence (PCL) reaction. The possible mechanism for the PCL was proposed based on studies of the CL kinetic characteristic and the CL spectra. The experimental conditions of the CL reactions were optimized and the feasibility of using the reaction to analyse these metal ions was evaluated. The PCL reaction method operates in the ranges: 1 × 10−7–8 × 10−6 g/L Ni2+; 3 × 10−6–2 × 10−4 g/L Mg2+; 8 × 10−7–1 × 10−4 g/L Cd2+; and 2 × 10−4–2 × 10−3 g/L Zn2+, with detection limits of 4 × 10−8 g/mL, 1 × 10−6 g/mL, 3 × 10−7 g/mL, 8 × 10−5 g/mL, respectively. Copyright © 2005 John Wiley & Sons, Ltd.
- 1 July 2005
- Published by Wiley in Luminescence
- Vol. 20 (4-5) , 266-270
Post‐chemiluminescence behaviour of Ni2+, Mg2+, Cd2+ and Zn2+ in the potassium ferricyanide–luminol reaction
A new chemiluminescence (CL) reaction was observed when Ni2+, Mg2+, Cd2+ or Zn2+ was injected into the reaction mixture after the finish of the CL reaction of alkaline luminol and potassium ferricyanide. This reaction is described as a post‐chemiluminescence (PCL) reaction. The possible mechanism for the PCL was proposed based on studies of the CL kinetic characteristic and the CL spectra. The experimental conditions of the CL reactions were optimized and the feasibility of using the reaction to analyse these metal ions was evaluated. The PCL reaction method operates in the ranges: 1 × 10−7–8 × 10−6 g/L Ni2+; 3 × 10−6–2 × 10−4 g/L Mg2+; 8 × 10−7–1 × 10−4 g/L Cd2+; and 2 × 10−4–2 × 10−3 g/L Zn2+, with detection limits of 4 × 10−8 g/mL, 1 × 10−6 g/mL, 3 × 10−7 g/mL, 8 × 10−5 g/mL, respectively. Copyright © 2005 John Wiley & Sons, Ltd.