Jin-Long Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jin-Long Huang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Min-Chi Chen
Taichung Veterans General Hospital
2 shared publicationsChih-Tai Ting
National Yang Ming University
1 shared publicationChin-Fang Hung
Cardiovascular Center, Taichung Veterans General Hospital
1 shared publicationChung-Chi Wang
Taichung Veterans General Hospital
1 shared publicationClayton Chi-Chang Chen
Taichung Veterans General Hospital
1 shared publicationHo-Yi Lei
Cardiovascular Center, Taichung Veterans General Hospital
1 shared publication
Latest Publications
- 21 August 2010
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 26 (S2) , 223-235
Global and regional wall motion abnormalities of pacing-induced heart failure assessed by multi-detector row CT: a patient and canine model study
This study used multi-detector row CT (MDCT) to evaluate the regional geometric parameters of left ventricle (LV) in patients and dogs after right ventricular apical (RVA) pacing. First, we measured and compared the global and regional wall motion parameters derived from MDCT images between three patients post RVA pacing and seven age-matched healthy subjects. The LV ejection fraction (LVEF), LV end-diastolic volume and LV end-systolic volume were measured. We also measured the regional wall thickness, wall thickening and regional wall motion in 12 different segments of the LV. Second, we performed MDCT scan on five dogs as the study group (pacing wire + RVA pacing, 2 months) and four dogs as the sham control group (pacing wire, 2 months). The global and regional geometric parameters were compared within both human and canine groups. Compared with normal subjects, patients post RVA pacing had low LVEF (60.4 ± 10.5 vs. 33.2 ± 17.6, P = 0.014), impaired regional wall thickening and regional wall motion, particularly in segments near the pacing lead. Some segments near the pacing lead were showing dyskinesia after pacing. These findings were successfully reproduced in the canine model. We found that RVA pacing can result in impaired regional wall thickening and regional wall motion, particularly in segments near the pacing lead.
- 21 August 2010
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 26 (S2) , 223-235
Global and regional wall motion abnormalities of pacing-induced heart failure assessed by multi-detector row CT: a patient and canine model study
This study used multi-detector row CT (MDCT) to evaluate the regional geometric parameters of left ventricle (LV) in patients and dogs after right ventricular apical (RVA) pacing. First, we measured and compared the global and regional wall motion parameters derived from MDCT images between three patients post RVA pacing and seven age-matched healthy subjects. The LV ejection fraction (LVEF), LV end-diastolic volume and LV end-systolic volume were measured. We also measured the regional wall thickness, wall thickening and regional wall motion in 12 different segments of the LV. Second, we performed MDCT scan on five dogs as the study group (pacing wire + RVA pacing, 2 months) and four dogs as the sham control group (pacing wire, 2 months). The global and regional geometric parameters were compared within both human and canine groups. Compared with normal subjects, patients post RVA pacing had low LVEF (60.4 ± 10.5 vs. 33.2 ± 17.6, P = 0.014), impaired regional wall thickening and regional wall motion, particularly in segments near the pacing lead. Some segments near the pacing lead were showing dyskinesia after pacing. These findings were successfully reproduced in the canine model. We found that RVA pacing can result in impaired regional wall thickening and regional wall motion, particularly in segments near the pacing lead.
- 12 October 2006
- Published by Springer Nature in Pediatric Radiology
- Vol. 36 (12) , 1273-1282
Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility
Echocardiography is the first-line modality for the investigation of neonatal congenital heart disease. Diagnostic cardiac catheterization, which has a small but recognized risk, is usually performed if echocardiography fails to provide a confident evaluation of the lesions. To verify the technical and clinical feasibilities of replacing diagnostic cardiac catheterization with multidetector-row CT (MDCT) in neonatal complex congenital heart disease. Over a 1-year period we prospectively enrolled all neonates with complex congenital heart disease referred for diagnostic cardiac catheterization after initial assessment by echocardiography. MDCT was performed using a 40-detector-row CT scanner with dual syringe injection. A multidisciplinary congenital heart disease team evaluated the MDCT images and decided if further diagnostic cardiac catheterization was necessary. The accuracy of MDCT in detecting separate cardiovascular anomalies and bolus geometry of contrast enhancement were calculated. A total of 14 neonates were included in the study. No further diagnostic cardiac catheterization was needed in any neonate. The accuracy of MDCT in diagnosing separate cardiovascular anomalies was 98% (53/54) with only one atrial septal defect missed in a patient with coarctation syndrome. The average cardiovascular enhancement in evaluated chambers was 471 HU. No obvious beam-hardening artefact was observed. The technical and clinical feasibility of MDCT in complex congenital heart disease in neonates is confirmed. After initial assessment with echocardiography, MDCT could probably replace diagnostic cardiac catheterization for further anatomical clarification in neonates.
- 12 October 2006
- Published by Springer Nature in Pediatric Radiology
- Vol. 36 (12) , 1273-1282
Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility
Echocardiography is the first-line modality for the investigation of neonatal congenital heart disease. Diagnostic cardiac catheterization, which has a small but recognized risk, is usually performed if echocardiography fails to provide a confident evaluation of the lesions. To verify the technical and clinical feasibilities of replacing diagnostic cardiac catheterization with multidetector-row CT (MDCT) in neonatal complex congenital heart disease. Over a 1-year period we prospectively enrolled all neonates with complex congenital heart disease referred for diagnostic cardiac catheterization after initial assessment by echocardiography. MDCT was performed using a 40-detector-row CT scanner with dual syringe injection. A multidisciplinary congenital heart disease team evaluated the MDCT images and decided if further diagnostic cardiac catheterization was necessary. The accuracy of MDCT in detecting separate cardiovascular anomalies and bolus geometry of contrast enhancement were calculated. A total of 14 neonates were included in the study. No further diagnostic cardiac catheterization was needed in any neonate. The accuracy of MDCT in diagnosing separate cardiovascular anomalies was 98% (53/54) with only one atrial septal defect missed in a patient with coarctation syndrome. The average cardiovascular enhancement in evaluated chambers was 471 HU. No obvious beam-hardening artefact was observed. The technical and clinical feasibility of MDCT in complex congenital heart disease in neonates is confirmed. After initial assessment with echocardiography, MDCT could probably replace diagnostic cardiac catheterization for further anatomical clarification in neonates.