Lisa Feuchtbaum
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lisa Feuchtbaum has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
George Cunningham
California Department of Health Services, Genetic Disease Branch, Richmond, CA (USA)
3 shared publicationsLisa Faulkner
Genetic Disease Laboratory, California Department of Health Services, Richmond, California
2 shared publications- Robert J. Currier
Department of Pediatrics, University of California, San Francisco, CA 94158, USA
2 shared publications Ajit Bhandal
Public Health Institute, Berkeley, California
1 shared publicationFred Lorey
Genetic Disease Branch
1 shared publicationFred W. Lorey
1 shared publication
Latest Publications
- 1 September 2007
- Published by SAGE Publications in Journal of Empirical Research on Human Research Ethics
- Vol. 2 (3) , 3-14
Questioning the Need for Informed Consent: A Case Study of California's Experience with a Pilot Newborn Screening Research Project
California provides mandatory newborn screening for disorders that cause irreversible, severe disabilities if not identified and treated early in life. Parental consent is not required. In 2001, the Genetic Disease Branch was mandated to pilot test a new technology that could identify many additional disorders using the same blood specimen already collected. Study participation required informed consent, which was obtained for 47% of births during the study timeframe. The inability of hospitals to carry out the consent procedure for all newborns resulted in denial of testing and missed cases. If informed consent were waived, all newborns could have been tested. Several empirical questions are posed and each is examined from the perspective of society, the parents and the newborn. It is concluded that the legitimate needs of society and the interests of newborns should not be sacrificed to respond to the autonomy interests of the few parents who did not wish their infant to participate in the study, and that in the future, parental consent should be waived for projects evaluating new screening technologies.
- 1 September 2007
- Published by SAGE Publications in Journal of Empirical Research on Human Research Ethics
- Vol. 2 (3) , 3-14
Questioning the Need for Informed Consent: A Case Study of California's Experience with a Pilot Newborn Screening Research Project
California provides mandatory newborn screening for disorders that cause irreversible, severe disabilities if not identified and treated early in life. Parental consent is not required. In 2001, the Genetic Disease Branch was mandated to pilot test a new technology that could identify many additional disorders using the same blood specimen already collected. Study participation required informed consent, which was obtained for 47% of births during the study timeframe. The inability of hospitals to carry out the consent procedure for all newborns resulted in denial of testing and missed cases. If informed consent were waived, all newborns could have been tested. Several empirical questions are posed and each is examined from the perspective of society, the parents and the newborn. It is concluded that the legitimate needs of society and the interests of newborns should not be sacrificed to respond to the autonomy interests of the few parents who did not wish their infant to participate in the study, and that in the future, parental consent should be waived for projects evaluating new screening technologies.
- 1 May 2006
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 117, S253-60
Tandem mass spectrometry program implementation challenges for state newborn screening programs: national survey of barriers and issues.
A national survey was undertaken to identify the barriers faced by states that have already implemented tandem mass spectrometry (MS/MS) screening and those that have not yet done so. In April 2004, a 10-question survey was mailed to 106 individuals identified as key newborn screening contacts in each state. The survey requested information on issues that affected the state's ability to expand newborn screening to include MS/MS technology. Representatives from 51 of 53 states/territories responded to the survey. Of the 51 responding states, 32 (63%) said that they are offering MS/MS screening currently. The top 2 issues that most affected the ability of states to add MS/MS screening were difficulty acquiring support within the organization (66%) and funding limitations (63%). The screening criteria that were most difficult to address were knowledge about the natural history of MS/MS-detectable disorders if untreated (37%), the short-term costs of screening and diagnosis (36%), and the long-term follow-up costs (34%). The top-ranked laboratory issues were the high costs of equipment and supplies (53%) and the development of appropriate population-specific cutoff values (41%). The top-ranked follow-up issues were the availability of accepted protocols and guidelines for MS/MS diagnostic evaluations (59%) and the availability of adequate educational materials describing the disorders (44%). Several of the issues identified can be addressed through improved, more-comprehensive, patient surveillance systems that track patient health status and health services utilization, although other approaches need to be developed. Through a better understanding of these issues and challenges, the community of professionals who are concerned with the quality and scope of newborn screening may be better able to help states develop strategies to overcome these barriers.
- 1 May 2006
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 117, S253-60
Tandem mass spectrometry program implementation challenges for state newborn screening programs: national survey of barriers and issues.
A national survey was undertaken to identify the barriers faced by states that have already implemented tandem mass spectrometry (MS/MS) screening and those that have not yet done so. In April 2004, a 10-question survey was mailed to 106 individuals identified as key newborn screening contacts in each state. The survey requested information on issues that affected the state's ability to expand newborn screening to include MS/MS technology. Representatives from 51 of 53 states/territories responded to the survey. Of the 51 responding states, 32 (63%) said that they are offering MS/MS screening currently. The top 2 issues that most affected the ability of states to add MS/MS screening were difficulty acquiring support within the organization (66%) and funding limitations (63%). The screening criteria that were most difficult to address were knowledge about the natural history of MS/MS-detectable disorders if untreated (37%), the short-term costs of screening and diagnosis (36%), and the long-term follow-up costs (34%). The top-ranked laboratory issues were the high costs of equipment and supplies (53%) and the development of appropriate population-specific cutoff values (41%). The top-ranked follow-up issues were the availability of accepted protocols and guidelines for MS/MS diagnostic evaluations (59%) and the availability of adequate educational materials describing the disorders (44%). Several of the issues identified can be addressed through improved, more-comprehensive, patient surveillance systems that track patient health status and health services utilization, although other approaches need to be developed. Through a better understanding of these issues and challenges, the community of professionals who are concerned with the quality and scope of newborn screening may be better able to help states develop strategies to overcome these barriers.
- Open Access
- 1 May 2006
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 117 (Supplement) , S261-S269
California's Experience Implementing a Pilot Newborn Supplemental Screening Program Using Tandem Mass Spectrometry
OBJECTIVE. In response to a California legislative mandate, a pilot tandem mass spectrometry (MS/MS) screening program was undertaken by the Genetic Disease Branch of the California Department of Health Services between January 2002 and June 2003. This article outlines the Genetic Disease Branch approach to implementing the MS/MS pilot program and the program evaluation strategies used. METHODS. Through the use of multiple data collection methods, we were able to describe hospital participation patterns, screening test uptake, screening test performance, follow-up services utilization, and provider and family satisfaction with the educational materials and follow-up services provided. RESULTS. During the 18-month pilot program, just more than one half of California's 755698 newborns were offered MS/MS screening; among this group, 90% of parents chose to have their newborns screened. Fifty-one newborns were identified with MS/MS-detectable disorders, among 461 patients referred for follow-up testing (0.13% of the screened population). One disorder was diagnosed successfully for every 6939 newborns screened and for every 9 infants referred (excluding phenylketonuria). The overall California population prevalence of MS/MS-detectable disorders was 1 case per 6500 infants (excluding phenylketonuria). The positive predictive value for medium-chain acyl-CoA dehydrogenase deficiency was 86.7%, whereas the positive predictive value for short-chain acyl-CoA dehydrogenase deficiency was 21.6%. For a sample from Hawaii, 1 isovaleric aciduria case was detected among 6132 newborns. CONCLUSIONS. Evaluation of the California MS/MS screening pilot program demonstrated that this technology was effective in identifying additional metabolic disorders. The positive predictive value of screening was particularly good for medium-chain acyl-CoA dehydrogenase deficiency. Overall, patient referral rates were very acceptable. The utility of the program was also demonstrated by positive reviews from patients and providers.
- 1 May 2006
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 117 (Supplement) , S261-S269
Open AccessCalifornia's Experience Implementing a Pilot Newborn Supplemental Screening Program Using Tandem Mass Spectrometry
OBJECTIVE. In response to a California legislative mandate, a pilot tandem mass spectrometry (MS/MS) screening program was undertaken by the Genetic Disease Branch of the California Department of Health Services between January 2002 and June 2003. This article outlines the Genetic Disease Branch approach to implementing the MS/MS pilot program and the program evaluation strategies used. METHODS. Through the use of multiple data collection methods, we were able to describe hospital participation patterns, screening test uptake, screening test performance, follow-up services utilization, and provider and family satisfaction with the educational materials and follow-up services provided. RESULTS. During the 18-month pilot program, just more than one half of California's 755698 newborns were offered MS/MS screening; among this group, 90% of parents chose to have their newborns screened. Fifty-one newborns were identified with MS/MS-detectable disorders, among 461 patients referred for follow-up testing (0.13% of the screened population). One disorder was diagnosed successfully for every 6939 newborns screened and for every 9 infants referred (excluding phenylketonuria). The overall California population prevalence of MS/MS-detectable disorders was 1 case per 6500 infants (excluding phenylketonuria). The positive predictive value for medium-chain acyl-CoA dehydrogenase deficiency was 86.7%, whereas the positive predictive value for short-chain acyl-CoA dehydrogenase deficiency was 21.6%. For a sample from Hawaii, 1 isovaleric aciduria case was detected among 6132 newborns. CONCLUSIONS. Evaluation of the California MS/MS screening pilot program demonstrated that this technology was effective in identifying additional metabolic disorders. The positive predictive value of screening was particularly good for medium-chain acyl-CoA dehydrogenase deficiency. Overall, patient referral rates were very acceptable. The utility of the program was also demonstrated by positive reviews from patients and providers.
- 1 May 2006
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 117 (Supplement) , S280-S286
Economic Evaluation of Tandem Mass Spectrometry Screening in California
OBJECTIVE. On the basis of California’s experience implementing a pilot tandem mass spectrometry (MS/MS) screening program, an economic evaluation was conducted to determine the economic benefits and costs of a statewide MS/MS screening program. METHODS. Cost-effectiveness, benefit/cost, and cost-utility analyses were conducted with a base-case set of assumptions. The base-case assumptions were varied by using a set of more-favorable and less-favorable assumptions to test the robustness of the analysis findings. RESULTS. The total estimated, annualized, incremental costs of MS/MS screening of 540000 births in California were nearly $5.7 million; 83 affected newborns would be identified. Screening would reduce the expected lifetime costs of medical care for affected newborns by $7.2 million ($9.0 million in the best-case scenario and $1.8 million in the worst-case scenario). When all program costs and savings were considered, screening saved $1.5 million ($3.4 million saved in the best-case scenario and $3.8 million additional costs in the worst-case scenario). With only incremental program costs, the cost per life saved was $708000 and the cost per case detected was $68000. With consideration of the projected lifetime medical care costs, the total cost per case detected was $132000. MS/MS screening produced a benefit/cost ratio of $9.32 ($11.67 with the best-case set of assumptions and $4.34 with the worst-case set of assumptions). In this analysis, the benefits of screening exceeded total program costs by $47.1 million (the net incremental benefit). In the worst-case scenario, the net incremental benefit of screening was $18.9 million. Screening saved 949 quality-adjusted life-years (QALYs) and saved $1628 per QALY in the base case analysis. Under the worst-case scenario, the cost per QALY was $14922. CONCLUSIONS. We found that the benefits of MS/MS screening outweighed the costs and that the net benefits were significant and robust in various scenarios with various conservative underlying assumptions.
- 1 May 2006
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 117 (Supplement) , S280-S286
Economic Evaluation of Tandem Mass Spectrometry Screening in California
OBJECTIVE. On the basis of California’s experience implementing a pilot tandem mass spectrometry (MS/MS) screening program, an economic evaluation was conducted to determine the economic benefits and costs of a statewide MS/MS screening program. METHODS. Cost-effectiveness, benefit/cost, and cost-utility analyses were conducted with a base-case set of assumptions. The base-case assumptions were varied by using a set of more-favorable and less-favorable assumptions to test the robustness of the analysis findings. RESULTS. The total estimated, annualized, incremental costs of MS/MS screening of 540000 births in California were nearly $5.7 million; 83 affected newborns would be identified. Screening would reduce the expected lifetime costs of medical care for affected newborns by $7.2 million ($9.0 million in the best-case scenario and $1.8 million in the worst-case scenario). When all program costs and savings were considered, screening saved $1.5 million ($3.4 million saved in the best-case scenario and $3.8 million additional costs in the worst-case scenario). With only incremental program costs, the cost per life saved was $708000 and the cost per case detected was $68000. With consideration of the projected lifetime medical care costs, the total cost per case detected was $132000. MS/MS screening produced a benefit/cost ratio of $9.32 ($11.67 with the best-case set of assumptions and $4.34 with the worst-case set of assumptions). In this analysis, the benefits of screening exceeded total program costs by $47.1 million (the net incremental benefit). In the worst-case scenario, the net incremental benefit of screening was $18.9 million. Screening saved 949 quality-adjusted life-years (QALYs) and saved $1628 per QALY in the base case analysis. Under the worst-case scenario, the cost per QALY was $14922. CONCLUSIONS. We found that the benefits of MS/MS screening outweighed the costs and that the net benefits were significant and robust in various scenarios with various conservative underlying assumptions.
- 1 September 1999
- Published by SAGE Publications in Genetic Testing
- Vol. 3 (3) , 265-272
Neural Tube Defect Prevalence in California (1990-1994): Eliciting Patterns by Type of Defect and Maternal Race/Ethnicity
This study presents race/ethnicity-specific prevalence estimates of neural tube defects (NTDs) in California using 5 years of population-based data. NTD prevalence estimates include prenatally diagnosed cases, as well as cases diagnosed at birth. The California NTD Registry contains NTD case reports identified through the California Maternal Serum Alpha-Feto Protein (AFP) Screening Program, the California Birth Defects Monitoring Program, and additional reports from clinicians and clinics throughout the state. These data were used to estimate NTD prevalence in a large population-based study (n = 1,618,279). The overall NTD prevalence among White, Black, Hispanic, and Asian women are reported, as well as race/ethnic prevalence, for anencephaly, spina bifida, and encephalocele. Rates are expressed as the number of cases per 1,000 women screened between 1990 and 1994. Among 1,457 women with an NTD-affected pregnancy, the overall rate for anencephaly, spina bifida, and encephalocele was 0.49 (95% CI 0.46-0.53), 0.42 (95% CI 0.38-0.45), and 0.08 (95% CI 0.07-0.09), respectively. When these types of NTDs are combined, Hispanic women had the highest overall rate (1.12, 95% CI 1.04-1.21), followed by Whites (0.96, 95% CI 0.89-1.04), Blacks (0.75, 95% CI 0.59-0.91), and Asians (0.75, 95% CI 0.60-0.90). Hispanic women were 45% more likely than White women to have a pregnancy affected with anencephaly (odds ratio = 1.45, 95% CI 1.24-1.70), while Asian women were over two times less likely to have a pregnancy affected with spina bifida (odds ratio = 0.44, 95% CI 0.29-0.65). Considerable variation exists in the prevalence of NTDs by race/ethnicity and by type of NTD, with Hispanic women exhibiting the highest overall NTD rate.
- 1 September 1999
- Published by SAGE Publications in Genetic Testing
- Vol. 3 (3) , 265-272
Neural Tube Defect Prevalence in California (1990-1994): Eliciting Patterns by Type of Defect and Maternal Race/Ethnicity
This study presents race/ethnicity-specific prevalence estimates of neural tube defects (NTDs) in California using 5 years of population-based data. NTD prevalence estimates include prenatally diagnosed cases, as well as cases diagnosed at birth. The California NTD Registry contains NTD case reports identified through the California Maternal Serum Alpha-Feto Protein (AFP) Screening Program, the California Birth Defects Monitoring Program, and additional reports from clinicians and clinics throughout the state. These data were used to estimate NTD prevalence in a large population-based study (n = 1,618,279). The overall NTD prevalence among White, Black, Hispanic, and Asian women are reported, as well as race/ethnic prevalence, for anencephaly, spina bifida, and encephalocele. Rates are expressed as the number of cases per 1,000 women screened between 1990 and 1994. Among 1,457 women with an NTD-affected pregnancy, the overall rate for anencephaly, spina bifida, and encephalocele was 0.49 (95% CI 0.46-0.53), 0.42 (95% CI 0.38-0.45), and 0.08 (95% CI 0.07-0.09), respectively. When these types of NTDs are combined, Hispanic women had the highest overall rate (1.12, 95% CI 1.04-1.21), followed by Whites (0.96, 95% CI 0.89-1.04), Blacks (0.75, 95% CI 0.59-0.91), and Asians (0.75, 95% CI 0.60-0.90). Hispanic women were 45% more likely than White women to have a pregnancy affected with anencephaly (odds ratio = 1.45, 95% CI 1.24-1.70), while Asian women were over two times less likely to have a pregnancy affected with spina bifida (odds ratio = 0.44, 95% CI 0.29-0.65). Considerable variation exists in the prevalence of NTDs by race/ethnicity and by type of NTD, with Hispanic women exhibiting the highest overall NTD rate.