JAJorge L. Alio

Jorge L. Alio

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jorge L. Alio has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Microbial Keratitis After Intrastromal Corneal Ring Segment Implantation

    by M. Emilia Mulet, Juan J. Pérez-Santonja, Consuelo Ferrer, Jorge L. Alió

    PURPOSE: To evaluate the incidence of acute microbial keratitis after intrastromal corneal ring segment implantation and to investigate whether microbial keratitis is related to the intrastromal corneal ring type or surgical technique. METHODS: Intrastromal corneal ring segments were implanted in 212 eyes of 149 patients. Two different types of intrastromal corneal ring segments were used during the study, Intacs and Ferrara rings, and two surgical techniques were used for intrastromal corneal ring segment implantation, manual and femtosecond laser. RESULTS: One hundred thirty-four eyes (63.2%) underwent Intacs implantation and 78 (36.8%) eyes received Ferrara rings. Corneal tunnels were created using the manual technique in 119 (56.1%) eyes and by femtosecond laser in 93 (43.9%) eyes. Three cases (1.4%) of acute microbial keratitis were clinically identified. Cultures were positive in 2 eyes and negative in 1 eye, and polymerase chain reaction was positive in all 3 cases. The microorganisms isolated from cultures were Streptococcus mitis and Staphylococcus aureus . In 2 cases, the femtosecond laser technique was used (1 eye Intacs, 1 eye Ferrara), and in 1 case, the manual technique was used (Intacs). No statistically significant difference was noted between techniques ( P =.582) or segment type ( P =1.000). In all cases, intrastromal corneal ring segments were explanted and intensive topical antibiotics were used with clinical success. CONCLUSIONS: Acute microbial keratitis incidence after intrastromal corneal ring segment implantation was 1.4%. Gram-positive cocci were the organisms isolated more frequently. Proper management of this condition requires intrastromal corneal ring segment explantation and intensive topical antibiotics. [ J Refract Surg . 2010;26:364–369.]


  • Spontaneous Bilateral, Recurrent, Late-onset Diffuse Lamellar Keratitis After LASIK in a Patient With Cogan's Syndrome

    by Jaime Javaloy, Carlos Barrera, Gonzalo Muñoz, Juan J. Pérez-Santonja, María T. Vidal, Jorge L. Alió

    Purpose: To report a patient with severe and progressive bilateral deafness who suffered recurrent episodes of diffuse lamellar keratitis (DLK) in both eyes ⩾4 months after undergoing uneventful LASIK for myopia. Methods: Four months after LASIK, the patient presented with blurred vision in the left eye. Best spectacle-corrected visual acuity was 0.9. Slit-lamp examination revealed aggregates of white cells at the paracentral and mid-peripheral interface without affecting the visual axis. Diffuse lamellar keratitis stage II was diagnosed and intensive corticosteroid treatment was started. Uncorrected visual acuity (UCVA) in the right eye was 1.2 with no signs of DLK. Results: One week after initiating corticosteroid treatment, UCVA improved (1.2) in the left eye. Diffuse lamellar keratitis was diagnosed in the left eye again at 9 months and in the right eye at 15 months after LASIK. The patient was later diagnosed with atypical Cogan's syndrome. Conclusions: Recurrent and late-onset DLK may be due to other patient systemic conditions predisposing to interstitial keratitis, such as Cogan's syndrome. [ J Refract Surg. 2008;24:548–550.]


  • Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes

    by Dolores Ortiz, David Piñero, Mohamed H. Shabayek, Francisco Arnalich-Montiel, Jorge L. Alió

    To compare the biomechanical properties of normal, post-laser in situ keratomileusis (LASIK), and keratoconic corneas evaluated by corneal hysteresis and the corneal resistance factor measured with the Reichert Ocular Response Analyzer (ORA). Instituto Oftalmológico de Alicante, Vissum, Alicante, Spain. Two hundred fifty eyes were divided into 3 groups: normal (control group), post-LASIK, and keratoconus. The corneal biomechanical properties were measured with the ORA, which uses a dynamic bidirectional applanation process. The main outcome measures were intraocular pressure, corneal hysteresis, and the corneal resistance factor. The control group had 165 eyes; the LASIK group, 65 eyes; and the keratoconus group, 21 eyes. In the control group, the mean corneal hysteresis value was 10.8 mm Hg +/- 1.5 (SD) and the mean corneal resistance factor, 11.0 +/- 1.6 mm Hg. The corneal hysteresis value was lower in older eyes, and the difference between the youngest age group (9 to 14 years) and oldest age group (60 to 80 years) was statistically significant (P = .01, t test). One month after LASIK, corneal hysteresis and the corneal resistance factor decreased significantly, from 10.44 to 9.3 mm Hg and from 10.07 to 8.13 mm Hg, respectively. In the keratoconus group, the mean corneal hysteresis was 7.5 +/- 1.2 mm Hg and the mean corneal resistance factor, 6.2 +/- 1.9 mm Hg. There were statistically significant differences in both biomechanical parameters between keratoconic eyes and post-LASIK eyes (P<.001, t test). The corneal hysteresis and corneal resistance factor values were significantly lower in keratoconic eyes than in post-LASIK eyes. Future work is needed to determine whether these differences are useful in detecting keratoconus when other diagnostic tests are equivocal.


  • Treatment of Ocular Surface Syndrome After LASIK With Autologous Platelet-rich Plasma

    by Jorge L. Alio, Silvia Pastor, Jose Ruiz-Colecha, Alejandra Rodriguez, Alberto Artola

    Purpose: To ascertain the usefulness of platelet-rich plasma in the treatment of patients suffering from symptomatic ocular surface syndrome following LASIK. Methods: Twenty-six eyes (9 women and 4 men) affected by symptomatic ocular surface syndrome were treated with topical eye drops of autologous platelet-rich plasma and results were reported at 4 weeks. Topical platelet-rich plasma was prepared from total blood and enriched in platelets by centrifugation. Results: Eighty-five percent of patients experienced significant improvement of symptoms; best spectacle-corrected visual acuity increased 1 to 2 lines in 54%; fluorescein staining analysis showed a 69% full fluorescein disappearance; and tear break-up time increased >2 seconds in 46%. Only one patient developed intolerance to platelet-rich plasma after 4 weeks. Conclusions: Autologous platelet-rich plasma was effective in the treatment of patients with ocular surface syndrome following LASIK, with symptoms generally relieved and a positive effect on punctate keratitis. [ J Refract Surg . 2007;23:617–619.]


  • Symptomatic Dry Eye Treatment with Autologous Platelet-Rich Plasma

    by Jorge L. Alio, José R. Colecha, Silvia Pastor, Alejandra Rodriguez, Alberto Artola

    Background: Autologous platelet-rich plasma (PRP) has been proven to be very effective on tissue regeneration and wound healing. Here we investigate the potential use of PRP in the treatment of symptomatic dry eye. Methods: Eighteen consecutive patients with symptomatic dry eye were treated with topical PRP and followed up for 1 month. Disappearance of subjective symptoms, increase in best corrected visual acuity, tear meniscus, tear breakup time, decrease in inflammation, fluorescein staining and improvement in impression cytology were measured. Results: Symptoms improved significantly in 89% of the patients, 28% improved at least 1 line of best corrected visual acuity. A significant improvement on lachrymal meniscus and conjunctival hyperemia and a decrease or disappearance of corneal fluorescein staining were observed. Impression cytology revealed a significant increase in conjunctival goblet cells. Conclusion: Treatment of patients suffering from significant dry eye symptoms with autologous RPR proved to be very effective, improving both patient symptoms and major clinical signs.


  • Optical Analysis of PresbyLASIK Treatment By a Light Propagation Algorithm

    by Dolores Ortiz, Jorge L. Alió, Carlos Illueca, David Mas, Esperanza Sala, Jorge Pérez, J. Espinosa

    Purpose: To evaluate the changes in the optical quality of corneas of hyperopic patients operated using central multifocal presbyLASIK treatment through the study of light patterns around the retinal plane. Methods: This study included eight hyperopic eyes that underwent central presbyLASIK surgery with Presby-one software using an H. Eye Tech Technovision excimer laser platform. Mean patient age was 57 years. Mean preoperative spherical equivalent refraction was 1.28±0.87 diopters (D). Mean distance decimal visual acuity with correction was 1.02±0.13 and without correction was 0.37±0.15. The optical quality was characterized by the Strehl ratio, the spot size on the retina, and objective decimal visual acuity calculated based on measured corneal topography using Fresnel propagation algorithm based on a realistic eye model. Results: The postoperative spherical equivalent refraction was −0.55±0.48 D. The distance decimal visual acuity with correction was 0.94 and without correction was 0.70. The pseudoaccommodation range was 1.60±0.40 D. A good Pearson correlation coefficient was obtained (r 2 =0.86) for the linear fit between the real and calculated decimal visual acuity for the eight eyes. The Strehl ratio value on the retinal plane increased after the surgery by a mean factor of 4.7. Conclusions: With a complete characterization of the eye and a complete propagation algorithm (that takes into account all refractive surfaces in the eye at the same time), it is possible to evaluate the optical quality in eyes of patients who have undergone central presbyLASIK treatment. [ J Refract Surg . 2007;23:39–44.]


  • LASIK in Myopic Patients With Dermatological Keloids

    by Alberto Artola, Ahmed Galal, José I Belda, Juan J Pérez-Santonja, Jose Luis Rodriguez-Prats, José María Ruiz-Moreno, Jorge L Altó

    PURPOSE: To evaluate the visual and refractive outcome of LASIK in myopic patients with a known history of dermatological keloid scar. METHODS: This retrospective case series included 10 eyes of 5 white patients with a known history of dermatological keloids. All patients had low to moderate myopia with no corneal or limbal keloid. All underwent uneventful bilateral LASIK. Postoperatively, visual outcomes, refractive outcomes, and complications were evaluated. Minimum 1-year follow-up was indicated for all patients in this study. RESULTS: Mean preoperative uncorrected visual acuity (UCVA) was 20/320 and 1 year postoperative was 20/20. Mean preoperative best spectacle-corrected visual acuity (BSCVA) was 20/25 and 1 year postoperative was 20/20. The mean preoperative spherical equivalent refraction was -5.00±2.6 diopters (D) and +0.1±0.2 D 1 year postoperative. The safety index was 1.02 and the efficacy index was 1.02. None of the eyes included in this study underwent retreatment for correction of residual error or regression up to 1 year post-operatively. No sight-threatening complications were reported. No patient reported postoperative haze, severe dry eye syndrome, or flap-related problems. CONCLUSIONS: LASIK is a safe, effective, and predictable technique for correcting low and moderate myopia in patients with dermatological keloids. [J Refract Surg. 2006;22:505-508.]


  • Adal-1 bioadhesive for sutureless recession muscle surgery: a clinical trial

    by M E Mulet, J L Alio, M M Mahiques, J M Martin

    Aims: To evaluate the efficacy and biotolerance of the Adal-1 adhesive for muscle sealing in strabismus surgery. Methods: 27 eyes were included in the study: 17 in the control group and 10 in the study group. Surgery was performed on the recession of the horizontal rectus muscles. In the control group the muscle was joined to the sclera by a Vicryl 7/0 suture. In the study group, the Adal-1 adhesive was used instead. The efficacy of the sealing of the muscle to the sclera and the biotolerance of the surrounding tissues were evaluated. Results: The muscular recession in the control group was 8.17 (SD 2.38) with displacement of the sealing point of 0.02 (1.7) mm. In the group sealed with adhesive, the muscular recession was 9.09 (3.08) and the displacement was 0.15 (1.56) mm, with no significant differences between the techniques (p0.05), but there were no differences in the other postoperative periods (Mann-Whitney U test). Conclusion: Adal-1 was an effective and safe alternative to sutures in muscle recession for strabismus surgery in this study.