So-Hee Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
So-Hee Kim has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
H.I. Kim
Food Additives and Packages Division , National Institute of Food and Drug Safety Evaluation , 194 Tongil-ro, Eungpyung-gu, Seoul, Korea
1 shared publicationH.J. Park
Graduate School of Life Sciences and Biotechnology , Korea University, Anam-dong , Seongbuk-gu, Seoul, Korea
1 shared publicationH.S. Lim
Food Additives and Packages Division , National Institute of Food and Drug Safety Evaluation , 194 Tongil-ro, Eungpyung-gu, Seoul, Korea
1 shared publicationHo-Soo Lim
Korea Food & Drug Administration
1 shared publicationHyung-Il Kim
Korea Food & Drug Administration
1 shared publicationI.S. Kwak
Food Additives and Packages Division , National Institute of Food and Drug Safety Evaluation , 194 Tongil-ro, Eungpyung-gu, Seoul, Korea
1 shared publication
Latest Publications
- 28 February 2013
- Published by Springer Nature in Food Science and Biotechnology
- Vol. 22 (S1) , 233-240
HPLC-MS/MS analysis of 9 artificial sweeteners in imported foods
- 28 February 2013
- Published by Springer Nature in Food Science and Biotechnology
- Vol. 22 (S1) , 233-240
HPLC-MS/MS analysis of 9 artificial sweeteners in imported foods
- 24 November 2010
- Published by Taylor & Francis in Food Additives & Contaminants: Part A
- Vol. 27 (12) , 1745-1754
Liquid chromatography-tandem mass spectrometry determination of N-nitrosamines released from rubber or elastomer teats and soothers
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method as an alternative to a gas chromatography-thermal energy analyser (GC-TEA) method recommended by the European Committee on Standardization (CEN) was validated for the simultaneous determination of eight N-nitrosamines released into artificial saliva from rubber or elastomer teats and soothers. N-nitroso-dipropylamine-d14 (NDPA-d14) was used as internal standard for accurate quantification. The method was validated with relatively good analytical results, including sufficiently low limits of detection (0.1–2 µg kg−1 of sample) and good linearity (r 2 > 0.99) throughout the studied concentration ranges. Intra- and inter-day precisions expressed with the relative standard deviation (RSD, %) were 3.4–8.0% and 4.4–11.3%, which were below the performance criteria based on one-half of the value derived from the Horwitz value. It was also found that the LC-MS/MS method is sufficiently rugged and successfully applicable to its routine analysis for the compliance test of Commission Directive 93/11/EEC.
- 24 November 2010
- Published by Taylor & Francis in Food Additives & Contaminants: Part A
- Vol. 27 (12) , 1745-1754
Liquid chromatography-tandem mass spectrometry determination of N-nitrosamines released from rubber or elastomer teats and soothers
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method as an alternative to a gas chromatography-thermal energy analyser (GC-TEA) method recommended by the European Committee on Standardization (CEN) was validated for the simultaneous determination of eight N-nitrosamines released into artificial saliva from rubber or elastomer teats and soothers. N-nitroso-dipropylamine-d14 (NDPA-d14) was used as internal standard for accurate quantification. The method was validated with relatively good analytical results, including sufficiently low limits of detection (0.1–2 µg kg−1 of sample) and good linearity (r 2 > 0.99) throughout the studied concentration ranges. Intra- and inter-day precisions expressed with the relative standard deviation (RSD, %) were 3.4–8.0% and 4.4–11.3%, which were below the performance criteria based on one-half of the value derived from the Horwitz value. It was also found that the LC-MS/MS method is sufficiently rugged and successfully applicable to its routine analysis for the compliance test of Commission Directive 93/11/EEC.