Lin Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lin Xie has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Yan Liang
Key Lab of Drug Metabolism & Pharmacokinetics, China Pharmaceutical University, Nanjing, Jiangsu Province, China
6 shared publicationsGuang-Ji Wang
Key Lab of Drug Metabolism & Pharmacokinetics, China Pharmaceutical University, Nanjing 210038, China
3 shared publicationsAn Kang
Key Lab of Drug Metabolism & Pharmacokinetics, China Pharmaceutical University, Nanjing 210038, China
2 shared publications- Guangji Wang
Jiangsu Provincial Key Laboratory of Drug Metabolism and Pharmacokinetics, China Pharmaceutical University, Nanjing 210009, China
2 shared publications Hao Li
Key Lab of Drug Metabolism and Pharmacokinetics , China Pharmaceutical University , China
2 shared publicationsWei-Dong Chen
China Pharmaceutical University
2 shared publications
Latest Publications
- Open Access
- 12 June 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (6) , e98717
Pharmacokinetic Compatibility of Ginsenosides and Schisandra Lignans in Shengmai-san: From the Perspective of P-Glycoprotein
Phytochemical-mediated alterations in P-glycoprotein (P-gp) activity may result in herb-drug interactions by altering drug pharmacokinetics. Shengmai-san, a traditional Chinese herbal medicine composed by Panax Ginseng, Ophiopogon Japonicus, and Schisandra Chinensis, is routinely being used for treating various coronary heart diseases. In our previous studies, Schisandra Lignans Extract (SLE) was proved as a strong P-gp inhibitor, and herein, the compatibility of Shengmai-san was studied by investigating the influence of SLE on the pharmacokinetics of the ginsenosides from the perspective of P-gp. Pharmacokinetic experiments were firstly performed based on in vitro uptake, efflux and transport experiments in Caco-2, LLC-PK1 wild-type and MDR1-overexpressing L-MDR1 cells. During the whole experiment, digoxin, a classical P-gp substrate, was used as a positive control drug to verify the cells used are the valid models. Meanwhile, the effects of SLE on the pharmacokinetics of ginsenosides were further investigated in rats after single-dose and multi-dose of SLE. The efflux ratios of ginsenoside Rb2, Rc, Rg2, Rg3, Rd and Rb1 were found more than 3.5 in L-MDR1 cells and can be decreased significantly by verapamil (a classical P-gp inhibitor). Contrarily, the efflux ratios of other ginsenosides (Rh1, F1, Re, and Rg1) were lower than 2.0 and not affected by verapamil. Then, the effects of SLE on the uptake and transport of ginsenosides were investigated, and SLE was found can significantly enhance the uptake and inhibit the efflux ratio of ginsenoside Rb2, Rc, Rg2, Rg3, Rd and Rb1 in Caco-2 and L-MDR1 cells. Besides, In vivo experiments showed that single-dose and multi-dose of SLE at 500 mg/kg could increase the area under the plasma concentration time curve of Rb2, Rc and Rd significantly without affecting terminal elimination half-time. In conclusion, SLE could enhance the exposure of ginsenosides Rb2, Rc, Rg2, Rg3, Rd and Rb1 significantly.
- 12 June 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (6) , e98717
Open AccessPharmacokinetic Compatibility of Ginsenosides and Schisandra Lignans in Shengmai-san: From the Perspective of P-Glycoprotein
Phytochemical-mediated alterations in P-glycoprotein (P-gp) activity may result in herb-drug interactions by altering drug pharmacokinetics. Shengmai-san, a traditional Chinese herbal medicine composed by Panax Ginseng, Ophiopogon Japonicus, and Schisandra Chinensis, is routinely being used for treating various coronary heart diseases. In our previous studies, Schisandra Lignans Extract (SLE) was proved as a strong P-gp inhibitor, and herein, the compatibility of Shengmai-san was studied by investigating the influence of SLE on the pharmacokinetics of the ginsenosides from the perspective of P-gp. Pharmacokinetic experiments were firstly performed based on in vitro uptake, efflux and transport experiments in Caco-2, LLC-PK1 wild-type and MDR1-overexpressing L-MDR1 cells. During the whole experiment, digoxin, a classical P-gp substrate, was used as a positive control drug to verify the cells used are the valid models. Meanwhile, the effects of SLE on the pharmacokinetics of ginsenosides were further investigated in rats after single-dose and multi-dose of SLE. The efflux ratios of ginsenoside Rb2, Rc, Rg2, Rg3, Rd and Rb1 were found more than 3.5 in L-MDR1 cells and can be decreased significantly by verapamil (a classical P-gp inhibitor). Contrarily, the efflux ratios of other ginsenosides (Rh1, F1, Re, and Rg1) were lower than 2.0 and not affected by verapamil. Then, the effects of SLE on the uptake and transport of ginsenosides were investigated, and SLE was found can significantly enhance the uptake and inhibit the efflux ratio of ginsenoside Rb2, Rc, Rg2, Rg3, Rd and Rb1 in Caco-2 and L-MDR1 cells. Besides, In vivo experiments showed that single-dose and multi-dose of SLE at 500 mg/kg could increase the area under the plasma concentration time curve of Rb2, Rc and Rd significantly without affecting terminal elimination half-time. In conclusion, SLE could enhance the exposure of ginsenosides Rb2, Rc, Rg2, Rg3, Rd and Rb1 significantly.
- 15 June 2008
- Published by Elsevier in International Journal of Mass Spectrometry
- Vol. 273 (3) , 132-137
Selective, sensitive and simple LC–APCI–MS method for the quantitation of Alpha-Tocopheryl Nicotinate in human plasma
- 15 June 2008
- Published by Elsevier in International Journal of Mass Spectrometry
- Vol. 273 (3) , 132-137
Selective, sensitive and simple LC–APCI–MS method for the quantitation of Alpha-Tocopheryl Nicotinate in human plasma
- 4 July 2007
- Published by Springer Nature in Chromatographia
- Vol. 66 (3-4) , 165-170
Simple, Sensitive, and Rapid LC–ESI-MS Method for Quantification of Mitiglinide in Human Urine
- 4 July 2007
- Published by Springer Nature in Chromatographia
- Vol. 66 (3-4) , 165-170
Simple, Sensitive, and Rapid LC–ESI-MS Method for Quantification of Mitiglinide in Human Urine
- 1 June 2006
- Published by Taylor & Francis in Analytical Letters
- Vol. 39 (7) , 1365-1379
Simple, Sensitive, and Rapid LC–MS Method for the Quantitation of Indapamide in Human Plasma—Application to Pharmacokinetic Studies
A sensitive and specific liquid chromatography electrospray ionization mass spectrometry (LC–ESI–MS) method was developed and validated for the identification and quantification of indapamide in human plasma. After the addition of the internal standard (IS) and 0.1 M sodium hydroxide solution, plasma samples were extracted with diethyl ether. The organic layer was evaporated under a stream of nitrogen at 40°C. The residue was reconstituted with 200 µL methanol. The compounds were separated on a stainless‐steel column (C18 Shim‐pack 5 µm 150 mm×2.0 mm I.D., Shimadzu) at a flow rate of 0.2 mL/min by a gradient elution. Detection was performed on a single quadrupole mass spectrometer by selected ion monitoring (SIM) mode via an electrospray ionization (ESI) source. The method was proved to be sensitive and specific by testing six different plasma batches. Linearity was established for the range of concentrations 0.5–100.0 ng/mL with a coefficient of determination (r) of 0.9998 and good back‐calculated accuracy and precision. The intra‐ and inter‐day precision (RSD%) was lower than 10% and accuracy ranged from 85% to 115%. The lower limit of quantification was identifiable and reproducible at 0.2 ng/mL with 0.2 mL plasma. The proposed method enables the unambiguous identification and quantification of indapamide for pharmacokinetic, bioavailability, or bioequivalence studies.
- 1 June 2006
- Published by Taylor & Francis in Analytical Letters
- Vol. 39 (7) , 1365-1379
Simple, Sensitive, and Rapid LC–MS Method for the Quantitation of Indapamide in Human Plasma—Application to Pharmacokinetic Studies
A sensitive and specific liquid chromatography electrospray ionization mass spectrometry (LC–ESI–MS) method was developed and validated for the identification and quantification of indapamide in human plasma. After the addition of the internal standard (IS) and 0.1 M sodium hydroxide solution, plasma samples were extracted with diethyl ether. The organic layer was evaporated under a stream of nitrogen at 40°C. The residue was reconstituted with 200 µL methanol. The compounds were separated on a stainless‐steel column (C18 Shim‐pack 5 µm 150 mm×2.0 mm I.D., Shimadzu) at a flow rate of 0.2 mL/min by a gradient elution. Detection was performed on a single quadrupole mass spectrometer by selected ion monitoring (SIM) mode via an electrospray ionization (ESI) source. The method was proved to be sensitive and specific by testing six different plasma batches. Linearity was established for the range of concentrations 0.5–100.0 ng/mL with a coefficient of determination (r) of 0.9998 and good back‐calculated accuracy and precision. The intra‐ and inter‐day precision (RSD%) was lower than 10% and accuracy ranged from 85% to 115%. The lower limit of quantification was identifiable and reproducible at 0.2 ng/mL with 0.2 mL plasma. The proposed method enables the unambiguous identification and quantification of indapamide for pharmacokinetic, bioavailability, or bioequivalence studies.
- 11 April 2006
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 41 (1) , 256-260
Simple, sensitive and rapid LC–ESI–MS method for the quantitation of lafutidine in human plasma—Application to pharmacokinetic studies
- 11 April 2006
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 41 (1) , 256-260
Simple, sensitive and rapid LC–ESI–MS method for the quantitation of lafutidine in human plasma—Application to pharmacokinetic studies
- 17 January 2006
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 20 (4) , 523-528
Simple, sensitive and rapid liquid chromatography/atmospheric pressure chemical ionization mass spectrometric method for the quantitation of Ranolazine in rat plasma
A sensitive and specific method using liquid chromatography with atmospheric pressure chemical ionization mass spectrometry (LC/APCI‐MS) has been developed and validated for the identification and quantification of Ranolazine in rat plasma. A simple liquid–liquid extraction procedure was followed by injection of the extracts onto a C 18 column with isocratic elution and detection using a single quadrupole mass spectrometer in selected ion monitoring (SIM) mode. The method was tested using six different batches of blank plasma. Linearity was established for the concentration range 0.02–10.0 µg/mL, with a coefficient of determination ( r ) of 0.9998 and good back‐calculated accuracy and precision. The intra‐ and inter‐day precision (relative standard deviation (RSD) %) was lower than 10%, and accuracy ranged from 85 to 115%. The lower limit of quantification was reproducible at 0.01 µg/mL with 20 µL plasma. The proposed method enables the unambiguous identification and quantification of Ranolazine for pre‐clinical and clinical studies. Copyright © 2006 John Wiley & Sons, Ltd.
- 17 January 2006
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 20 (4) , 523-528
Simple, sensitive and rapid liquid chromatography/atmospheric pressure chemical ionization mass spectrometric method for the quantitation of Ranolazine in rat plasma
A sensitive and specific method using liquid chromatography with atmospheric pressure chemical ionization mass spectrometry (LC/APCI‐MS) has been developed and validated for the identification and quantification of Ranolazine in rat plasma. A simple liquid–liquid extraction procedure was followed by injection of the extracts onto a C 18 column with isocratic elution and detection using a single quadrupole mass spectrometer in selected ion monitoring (SIM) mode. The method was tested using six different batches of blank plasma. Linearity was established for the concentration range 0.02–10.0 µg/mL, with a coefficient of determination ( r ) of 0.9998 and good back‐calculated accuracy and precision. The intra‐ and inter‐day precision (relative standard deviation (RSD) %) was lower than 10%, and accuracy ranged from 85 to 115%. The lower limit of quantification was reproducible at 0.01 µg/mL with 20 µL plasma. The proposed method enables the unambiguous identification and quantification of Ranolazine for pre‐clinical and clinical studies. Copyright © 2006 John Wiley & Sons, Ltd.