ABAlessandra Biondi

Alessandra Biondi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alessandra Biondi has a total of 420 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The Contour Neurovascular System Versus Woven Endobridge for Endovascular Embolization of Cerebral Aneurysms: A Propensity Score-matched Cohort Study

    by Christoph J. Griessenauer, Sherief Ghozy, Hamza A. Salim, Nimer Adeeb, Basel Musmar, Alessandra Biondi, Fritz Wodarg, Thomas Liebig, Tufail Patankar, Sal Lamin, et al.

    BACKGROUND AND OBJECTIVES: The Woven Endobridge (WEB) and the Contour Neurovascular System (Contour) are both intrasaccular devices used to treat cerebral aneurysms. We compared outcomes of these 2 devices using data from 2 large registries. METHODS: Data were sourced from the WorldWideWEB Consortium, which included 1363 cases treated with WEB from 2017, and a registry of 277 Contour cases from 10 European centers starting the same year. Patient demographics, aneurysm characteristics, procedural specifics, and outcomes were analyzed. Propensity score matching was applied for comparison. RESULTS: Before matching, the Contour group had more men (37.9% vs 30.8%), more asymptomatic cases (83.4% vs 70.3%), and fewer acute subarachnoid hemorrhage cases (10.8% vs 26.2%). After matching, no significant differences were found in demographics or aneurysm characteristics between groups. The median age was 60 years, and median aneurysm dimensions were comparable. Logistic regression showed no significant differences between WEB and Contour in achieving complete occlusion (odds ratio [OR] = 1.01, 95% CI, 0.67-1.52, P = .971), adequate occlusion (OR = 0.85, 95% CI, 0.41-1.76, P = .665), or achieving modified Rankin Scale 0 to 2 at last follow-up (OR = 0.48, 95% CI, 0.21-1.02, P = .064). Retreatment (OR = 2.23, P = .086), thromboembolic complications (OR = 0.75, P = .452), and adjunctive treatment use (OR = 1.93, P = .141) were also similar. CONCLUSION: The WEB and Contour demonstrated comparable clinical and angiographic outcomes in this large multicenter study comprised majority small, asymptomatic cerebral aneurysms.

  • Open Access

    Long-term clinical follow-up of intracranial aneurysms treated with flow diverter devices: a bicentric retrospective study

    by Mahmoud Moubark, Alessandra Biondi, Moustafa Othman, Michael Findler, Giovanni Vitale, Francis Turjman

    Background: Flow diverter devices (FDDs) have revolutionized the treatment of intracranial aneurysms. However, comprehensive long-term outcome data across multiple device platforms remain limited, with most prior studies focusing exclusively on Pipeline embolization device (PED) outcomes. This study reports extensive long-term clinical follow-up of patients treated with various types of FDDs, providing critical safety and efficacy data for contemporary practice. Methods: We conducted a retrospective analysis of intracranial aneurysms treated with FDDs from February 2011 to July 2016 in two tertiary care centers in France. The study included 209 patients with 216 cerebral aneurysms (91.2% anterior circulation, 8.8% posterior circulation; 66.2% unruptured, 31.0% recanalized, 2.8% ruptured). The duration of clinical and angiographic follow-up ranged from 24 to 156 months. Kaplan–Meier analysis performed for complication-free survival and aneurysm occlusion durability. Multivariate analysis showed risk factors for delayed complications. Results: Long-term follow-up data were available for 202/209 (96.7%) patients. The early permanent morbidity and mortality rates were 3.8% and 1.4%, respectively. Between 12 and 18 months, procedure-related complications occurred in 5 of 202 patients (2.5%): two ischemic events, one delayed rupture, one silent intrastent stenosis, and one case of seizures following antiplatelet withdrawal. Only three patients (1.5%) were symptomatic. At the 24-month follow-up, complete aneurysm occlusion achieved in 81.0% of the patients, with adequate occlusion in 93.3%. Kaplan–Meier analysis revealed 97.5% complication-free survival at 18 months, with sustained durability thereafter. Multiple FDDs were the only significant independent predictor of delayed complications (OR: 7.066, 95% CI: 1.049–47.606, P < 0.045). No procedure-related complications or deaths occurred after 18 months. Conclusion: Beyond 18 months of follow-up, FDD treatment for intracranial aneurysms proves exceptional safety with no delayed complications, regardless of device type. However, the findings of this study also show 18 months as a critical threshold for complication risk assessment, a key implication that clinicians and researchers need to be aware of. The study also underscores the need for modified management strategies when multiple overlapping FDDs are deployed, which significantly increases the risk of delayed complications.

  • Correction to: Silk vista baby for the treatment of distal anterior cerebral artery aneurysms

    by Luca Scarcia, Frédéric Clarençon, Adam A. Dmytriw, Eimad Shotar, Pascal Jabbour, Marios Psychogios, Peter Sporns, Ajit S. Puri, Ameer E. Hassan, Oktay Algin, et al.

  • Flow Diversion versus Coiling with or without Stenting for Unruptured Wide-Neck Intracranial Aneurysms: A Randomized Comparison

    by William Boisseau, Xavier Combaz, Olivier Levrier, Stanislas Smajda, Simon Escalard, Michel Piotin, Alessandra Biondi, Guillaume Charbonnier, Cyril Dargazanli, Anne Laure Derelle, et al.

    BACKGROUND AND PURPOSE: There are few randomized trials comparing coiling (with or without stenting) and flow diversion (FD) for the treatment of wide-necked unruptured intracranial aneurysms (UIAs). MATERIALS AND METHODS: EVIDENCE was an investigator-led randomized (1:1) trial conducted in 7 French university hospitals. Patients with 7-20mm intradural UIAs with a 4-10mm neck and a “dome/neck” ratio ≥1 were randomly allocated to coiling with or without adjunctive stenting or FD alone. The composite primary efficacy outcome was “treatment failure,” defined as initial failure to treat the aneurysm; aneurysm rupture or retreatment during follow-up; death or dependency (mRS> 2); or an angiographic residual aneurysm adjudicated by an independent core laboratory at 12 months. The primary hypothesis (revised for slow accrual) was that FD would decrease treatment failures from 35% to 10%, requiring 90 patients. Primary analyses were intent to treat. RESULTS: Among the 91 enrolled patients, 4 (2 in each group) withdrew consent; 87 patients were included in the analysis: 43 in the FD group and 44 in the control group. Most patients had < 10mm (57/87; 65.5%) asymptomatic ophthalmic aneurysms (75/87, 82.2%). A poor primary outcome, ascertainable in 86 patients, was reached in 8/43 FD patients (18.6%, 95%CI 9.7%-32.6%) as compared to 10/43 coiling patients (23.3%, 95 CI 13.1%-37.7%) (RR = 0.80, 95%CI [0.35-1.83]; p=0.60). Serious adverse events were similar. CONCLUSIONS: For patients with mostly unruptured, wide-necked ophthalmic aneurysms <10mm, FD was not shown superior to coiling with or without stenting. ABBREVIATIONS: FD= Flow Diversion; SAC=Stent-Assisted Coiling; UIAs= Unruptured Intracranial Aneurysms.


  • Silk Vista Baby for the treatment of distal anterior cerebral artery aneurysms

    by Luca Scarcia, Frédéric Clarençon, Adam A. Dmytriw, Eimad Shotar, Pascal Jabbour, Marios Psychogios, Peter Sporns, Ajit S. Puri, Ameer E. Hassan, Oktay Algin, et al.

    Purpose Treating small-caliber vessel aneurysms with flow diverters poses challenges due to narrow luminal diameters and tortuous vasculature, which complicate the navigation and deployment of conventional devices using standard microcatheters. The Silk Vista Baby (SVB, Balt, Montmorency, France) flow diverter was developed to treat intracranial aneurysms located in smaller vessels or more distal segments and is compatible with 0.017″ microcatheters. We present the largest multicenter analysis to date evaluating the outcomes of SVB use in unruptured distal anterior cerebral artery (DACA) aneurysms. Methods Retrospective data from 20 centers were reviewed for patients with unruptured DACA aneurysms treated with the SVB. Demographic information, clinical presentation, radiographic characteristics, complications, and outcomes were recorded. Results Seventy-nine patients (79 DACA aneurysms) were treated between January 2018 and December 2022; 59 were female (74.7%), and the median age was 61 years (IQR 53–67). Most aneurysms were saccular (89.9%), and 65.8% involved a branch. The median parent vessel diameter was 1.9 mm (IQR 1.7–2.1). A single stent was implanted in 97.5% of cases; 2.5% required two stents. The median imaging follow-up duration was 12 months (IQR 9.5–24). At the last follow-up, 76% of aneurysms showed complete or near-complete occlusion (O’Kelly–Marotta scale C or D, Raymond-Roy 1 or 2). Overall, thromboembolic or hemorrhagic complications occurred in 14% of patients, with two cases being symptomatic. The mortality rate was 0%, and the retreatment rate was 1.3%. Conclusion In this multicenter series, the SVB flow diverter represented a valuable treatment option for distal anterior cerebral artery (DACA) aneurysms.


  • Flow-diverting stents for the treatment of unruptured distal anterior cerebral artery aneurysms: analysis of the CRETA Registry

    by Luca Scarcia, Frédéric Clarençon, Adam A Dmytriw, Eimad Shotar, Kevin Premat, Pascal Jabbour, Stavropoula I Tjoumakaris, Reid Gooch, Marios-Nikos Psychogios, Nikolaos Ntoulias, et al.

    Background Data about the safety and the efficacy of flow diversion for distal anterior cerebral artery (DACA) aneurysms are limited. We present the largest multicenter analysis evaluating the outcomes of flow diversion in unruptured DACA aneurysm treatment. Methods Databases from 39 centers were retrospectively reviewed for unruptured DACA aneurysms treated with flow-diverting stents. Demographics, clinical presentation, radiographic characteristics, procedural complications, and outcomes were assessed. Results A total of 168 patients with 168 unruptured DACA aneurysms were treated between January 2018 and December 2022. One hundred and twenty-five were women (74.4%) and the median age was 61 (IQR 52–67) years. The most common morphology was saccular (91.7%), with branch involvement in 61.9% of cases. Median parent vessel diameter was 1.9 mm (IQR 1.7–2.2) and stents were successfully deployed in 99.4% of cases. In 96.4% a single stent was implanted, while 3.6% of cases required two stents. Median imaging follow-up was 16.5 (IQR 7–24) months. At last follow-up the rate of occlusion (O’Kelly–Marotta scale C or D) was 82.1%. Symptomatic thromboembolic or hemorrhagic complications occurred in 5.3% of patients and the mortality rate was 0.6%. The rate of retreatment was 1.2%. Conclusions Flow-diverting stents are a reasonably safe and effective treatment option for unruptured DACA aneurysms.


  • Contour Neurovascular System for endovascular embolization of cerebral aneurysms: a multicenter cohort study of 10 European neurovascular centers

    by Christoph J Griessenauer, Sherief Ghozy, Alessandra Biondi, Constantin Hecker, Fritz Wodarg, Thomas Liebig, Tufail Patankar, Saleh Lamin, Mario Martínez-Galdámez, Christophe Cognard, et al.

    Background Intrasaccular devices have become increasingly popular in the treatment of cerebral aneurysms, particularly at the bifurcation. Here we evaluate the Contour Neurovascular System, an intrasaccular device for the endovascular treatment of cerebral aneurysms, in a multicenter cohort study, the largest to the best of our knowledge. Methods Consecutive patients with intracranial aneurysms treated with the Contour Neurovascular System between February 2017 and October 2022 at 10 European neurovascular centers were prospectively collected and retrospectively reviewed. Patient and aneurysm characteristics, procedural details, and angiographic and clinical outcomes were evaluated. Results During the study period, 279 aneurysms (median age of patients 60 years, IQR 52–68) were treated with Contour. In 83.2% of patients the device was placed electively, whereas the remaining patients were treated in the setting of acute subarachnoid hemorrhage. The most common locations were the middle cerebral artery (26.5%) followed by the anterior communicating region (26.2%). Median aneurysm dome and neck size were 5.2 mm (IQR 4.2–7) and 3.9 mm (IQR 3–5). Contour size 7 (39%) and 9 (25%) were most used. Thromboembolic and hemorrhagic complications occurred in 6.8% and 0.4% of aneurysms, respectively. Raymond-Roy 1 and 2 occlusions at last follow-up were achieved in 63.2% and 28.3%, respectively, resulting in adequate occlusion of 91.5% of aneurysms. Conclusion This is the largest multicenter study reporting the outcome on the Contour Neurovascular System. At 1 year, the self-evaluated data on safety and efficacy are comparable to data of existing intrasaccular devices. Contour is a promising technology in the treatment of cerebral aneurysms.


  • How to use the Contour intrasaccular device: two illustrative cases

    by Alessandra Biondi, Panagiotis Primikiris, Fortunato Di Caterino, Sergio Vancheri, Giovanni Vitale, Guillaume Charbonnier

    Contour (Stryker, Kalamazoo, MI) is a relatively new endosaccular device for the treatment of intracranial aneurysms.1 2 Its unique cup-like shape permits treatment of most lesions, including wide-necked, irregular, and shallowed-shaped aneurysms. The sizing of the device only requires two parameters: neck size and equatorial plane (width). It must be positioned at the neck of the aneurysm with the device proximal marker in the parent artery. In our experience, dual antiplatelet therapy is usually not required for intrasaccular devices and this is also an advantage of the Contour device. We report two illustrative cases of wide-neck aneurysms in the anterior and posterior circulation, respectively (video 1). In this video we demonstrate the feasibility of this treatment in a middle cerebral artery bifurcation with atypical triangular shape and typical tip-basilar aneurysm. Video 1 :


  • Longitudinal radiological follow-up of individual level non-ischemic cerebral enhancing lesions following endovascular aneurysm treatment

    by Zakaria Guetarni, Remy Bernard, Grégoire Boulouis, Marc-Antoine Labeyrie, Alessandra Biondi, Stéphane Velasco, Guillaume Saliou, Bruno Bartolini, Benjamin Daumas-Duport, Romain Bourcier, et al.

    Background Non-ischemic cerebral enhancing (NICE) lesions following aneurysm endovascular therapy are exceptionally rare, with unknown longitudinal evolution. Objective To evaluate the radiological behavior of individual NICE lesions over time. Methods Patients included in a retrospective national multicentric inception cohort were analyzed. NICE lesions were defined, using MRI, as delayed onset punctate, nodular, or annular foci enhancements with peri-lesion edema, distributed in the vascular territory of the aneurysm treatment, with no other confounding disease. Lesion burden and the longitudinal behavior of individual lesions were assessed. Results Twenty-two patients were included, with a median initial lesion burden of 36 (IQR 17–54) on the first MRI scan. Of the 22 patients with at least one follow-up MRI scan, 16 (73%) had new lesions occurring mainly within the first 200 weeks after the date of the procedure. The median number of new lesions per MRI was 6 (IQR 2–16). Among the same 22 patients, 7 (32%) had recurrent lesions. The median persistent enhancement of a NICE lesion was 13 weeks (IQR 6–30). No factor was predictive of early regression of enhancement activity with lesion regression kinetics mainly being patient-dependent. Conclusions The behavior of individual NICE lesions was found to be highly variable with an overall patient-dependent regression velocity.


  • Defining the optimal size of an aspiration catheter in relation to the arterial diameter during mechanical thrombectomy for stroke

    by Guillaume Charbonnier, Panagiotis Primikiris, Maxime Desmarets, Gregory Tio, Sergio Vancheri, Fortunato Di Caterino, Giovanni Vitale, Alessandra Biondi