Palash Kumar Basu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Palash Kumar Basu has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Nusrat Praween
Department of Avionics, Indian Institute of Space science and Technology, Thiruvananthapuram, Kerala, India
7 shared publications - Pammi Guru Krishna Thej
School of Computing, University of South Africa, Johannesburg, South Africa
5 shared publications - R. G. Anjitha
Indian Institute of Space Science and Technology
4 shared publications - Krishna Thej Pammi Guru
Department of Avionics, Indian Institute of Space Science and Technology, Thiruvanathapuram 695547, India
3 shared publications - Akshaya Mouly Vijayakumari
Department of Electronics and Communication, National Institute of Technology, Calicut, Kerala, India
2 shared publications - Amala Kannath
Department of Avionics, Indian Institute of Space Science and Technology, Trivandrum, Kerala, India
2 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (19) , 29632-29640
Defect-Engineered Interleaved In 2 O 3 -CuO Heterojunctions for Light-Assisted Selective Methane Detection: Impact of Vacancy Density and LED Wavelength
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (19) , 29632-29640
Defect-Engineered Interleaved In 2 O 3 -CuO Heterojunctions for Light-Assisted Selective Methane Detection: Impact of Vacancy Density and LED Wavelength
- 22 September 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1425
Electrochemical profiling of urinary extracellular vesicle proteomes to reveal differential hypoxic adaptation
- 22 September 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1425
Electrochemical profiling of urinary extracellular vesicle proteomes to reveal differential hypoxic adaptation
- 2 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 25 (3) , 391-401
An Integrated Electrochemical Biosensor Array Enabling Extracellular Vesicles Disruption and Multiplexed Lung Cancer Biomarker Detection
We introduce the EV-Disrupt and Detect System (EDDS), an innovative, portable biosensor utilizing electrochemical impedance spectroscopy (EIS) for the swift, low-volume, and economical assessment of extracellular vesicle (EVs)-related lung cancer biomarkers. The EDDS combines electric field-induced EVs disruption with the simultaneous detection of 4 critical biomarkers: TSG101, EGFR, GPC1, and GM2AP, directly from serum. EVs disruption occurred within 30 seconds utilizing a 50 mV, 1 kHz square wave, with disruption efficiency validated by nanoparticle tracking analysis (93.9%) and Western blotting to ensure protein integrity. Post-disruption, the released cargo was quantified by electrochemical impedance spectroscopy (EIS) across 4 specialized screen-printed electrodes (SPEs), with results corroborated by enzyme-linked immunosorbent test (ELISA). The electric field parameters (voltage, frequency, and duration) were optimized with 150 μL of serum, yielding a 0.218–2.809-fold enhancement in detectable biomarker concentrations. The EDDS markedly decreases processing time, cost, and technological complexity by obviating the necessity for traditional EVs isolation techniques such as ultracentrifugation or chromatography. This integrated platform facilitates direct EVs disruption and multiplexed biomarker identification within a singular workflow, providing a robust instrument for minimally invasive cancer diagnostics and advancing broader clinical applications in liquid biopsy.
- 2 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 25 (3) , 391-401
An Integrated Electrochemical Biosensor Array Enabling Extracellular Vesicles Disruption and Multiplexed Lung Cancer Biomarker Detection
We introduce the EV-Disrupt and Detect System (EDDS), an innovative, portable biosensor utilizing electrochemical impedance spectroscopy (EIS) for the swift, low-volume, and economical assessment of extracellular vesicle (EVs)-related lung cancer biomarkers. The EDDS combines electric field-induced EVs disruption with the simultaneous detection of 4 critical biomarkers: TSG101, EGFR, GPC1, and GM2AP, directly from serum. EVs disruption occurred within 30 seconds utilizing a 50 mV, 1 kHz square wave, with disruption efficiency validated by nanoparticle tracking analysis (93.9%) and Western blotting to ensure protein integrity. Post-disruption, the released cargo was quantified by electrochemical impedance spectroscopy (EIS) across 4 specialized screen-printed electrodes (SPEs), with results corroborated by enzyme-linked immunosorbent test (ELISA). The electric field parameters (voltage, frequency, and duration) were optimized with 150 μL of serum, yielding a 0.218–2.809-fold enhancement in detectable biomarker concentrations. The EDDS markedly decreases processing time, cost, and technological complexity by obviating the necessity for traditional EVs isolation techniques such as ultracentrifugation or chromatography. This integrated platform facilitates direct EVs disruption and multiplexed biomarker identification within a singular workflow, providing a robust instrument for minimally invasive cancer diagnostics and advancing broader clinical applications in liquid biopsy.
- 18 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (2) , 1-4
Colloidal Gold-Assisted Isolation and Electric Lysis of Small Exosomes for Electrochemical Detection of HER2 Cancer Biomarker
Extracellular vesicles (EVs) that contain human epidermal growth factor receptor 2 (HER2) biomarkers are released by both healthy and cancerous cells, presenting substantial potential for the precise detection of numerous disorders, including cancer. To accurately quantify proteins, EVs must initially be separated from serum and then lysed to extract their protein content. Although ultracentrifugation is the predominant isolation technique, it has constraints regarding scalability and repeatability. Furthermore, traditional detergent-based lysis techniques endanger protein stability. This study introduces an innovative method for EV isolation utilizing colloidal gold nanoparticles, succeeded by lysis through sinusoidal electrical stimulation. A nonFaradaic electrochemical impedance spectroscopy (EIS) system has been developed utilizing screen-printed electrodes for determining HER2 protein levels. EV isolation was confirmed via western blotting for the EV-associated markers CD63 and HSP70. To promote the lysis of EVs, the EV sample was exposed to sine wave signals of differing amplitudes, with optimal disruption noted between 100 mV and 500 mV. The lysate was examined via EIS, producing a linear behavior from 5 μg/mL to 0.05 ng/mL with a limit of quantification of 0.109 μg/mL in human serum. The developed platform thus proves suitable for quantifying the HER2 protein from breast cancer patients.
- 18 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (2) , 1-4
Colloidal Gold-Assisted Isolation and Electric Lysis of Small Exosomes for Electrochemical Detection of HER2 Cancer Biomarker
Extracellular vesicles (EVs) that contain human epidermal growth factor receptor 2 (HER2) biomarkers are released by both healthy and cancerous cells, presenting substantial potential for the precise detection of numerous disorders, including cancer. To accurately quantify proteins, EVs must initially be separated from serum and then lysed to extract their protein content. Although ultracentrifugation is the predominant isolation technique, it has constraints regarding scalability and repeatability. Furthermore, traditional detergent-based lysis techniques endanger protein stability. This study introduces an innovative method for EV isolation utilizing colloidal gold nanoparticles, succeeded by lysis through sinusoidal electrical stimulation. A nonFaradaic electrochemical impedance spectroscopy (EIS) system has been developed utilizing screen-printed electrodes for determining HER2 protein levels. EV isolation was confirmed via western blotting for the EV-associated markers CD63 and HSP70. To promote the lysis of EVs, the EV sample was exposed to sine wave signals of differing amplitudes, with optimal disruption noted between 100 mV and 500 mV. The lysate was examined via EIS, producing a linear behavior from 5 μg/mL to 0.05 ng/mL with a limit of quantification of 0.109 μg/mL in human serum. The developed platform thus proves suitable for quantifying the HER2 protein from breast cancer patients.
- 9 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (1) , 1-4
Functionalized SiO 2 Wafer Platform for on Chip Extracellular Vesicles Capture-Lysis for Electrochemical Sensing
We introduce silicon dioxide (SiO2) wafer-assisted technology for the isolation and quantification of extracellular vesicle (EV) biomarkers utilizing electrochemical impedance spectroscopy (EIS). Traditional EVs isolation techniques, including ultracentrifugation and precipitation, are laborious and have inconsistent recovery rates. This study involved the synthesis of gold nanoparticles (GNPs), which were subsequently deposited onto SiO2 wafers. Subsequently, the surface was functionalized with polyethylene glycol and activated using EDC/NHS chemistry to improve biomolecular binding. Approximately 6.8 × 108 EVs particles were effectively extracted from 200 μL of serum samples utilizing the GNP-coated silicon substrate, representing a significant portion of the expected ∼2 × 109 EVs typically present in such a volume. After immobilization, EVs were lysed directly on the surface using Triton X-100, and the lysis duration was optimized using Western blot analysis. The resultant lysate underwent EIS to assess variations in charge-transfer resistance (RCT), facilitating the precise identification of target proteins. The impedance response exhibited a concentration-dependent increase in RCT, with a detection limit of 1.206 pg/mL and a linear range of 62.5–2000 pg/mL. The results were confirmed by enzyme-linked immunosorbent assay, affirming the reliability and specificity of the electrochemical platform. This integrated isolation-lysing system offers a scalable and effective approach for EVs isolation and protein extraction. The proposed technique, in conjunction with the sensing platform, can be utilized in point-of-care diagnostics and liquid biopsy-based cancer detection.
- 9 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (1) , 1-4
Functionalized SiO 2 Wafer Platform for on Chip Extracellular Vesicles Capture-Lysis for Electrochemical Sensing
We introduce silicon dioxide (SiO2) wafer-assisted technology for the isolation and quantification of extracellular vesicle (EV) biomarkers utilizing electrochemical impedance spectroscopy (EIS). Traditional EVs isolation techniques, including ultracentrifugation and precipitation, are laborious and have inconsistent recovery rates. This study involved the synthesis of gold nanoparticles (GNPs), which were subsequently deposited onto SiO2 wafers. Subsequently, the surface was functionalized with polyethylene glycol and activated using EDC/NHS chemistry to improve biomolecular binding. Approximately 6.8 × 108 EVs particles were effectively extracted from 200 μL of serum samples utilizing the GNP-coated silicon substrate, representing a significant portion of the expected ∼2 × 109 EVs typically present in such a volume. After immobilization, EVs were lysed directly on the surface using Triton X-100, and the lysis duration was optimized using Western blot analysis. The resultant lysate underwent EIS to assess variations in charge-transfer resistance (RCT), facilitating the precise identification of target proteins. The impedance response exhibited a concentration-dependent increase in RCT, with a detection limit of 1.206 pg/mL and a linear range of 62.5–2000 pg/mL. The results were confirmed by enzyme-linked immunosorbent assay, affirming the reliability and specificity of the electrochemical platform. This integrated isolation-lysing system offers a scalable and effective approach for EVs isolation and protein extraction. The proposed technique, in conjunction with the sensing platform, can be utilized in point-of-care diagnostics and liquid biopsy-based cancer detection.
- 8 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 25 (1) , 62-69
High-Yield Isolation of Stem Cell-Derived Extracellular Vesicles Using a Gold Nanoparticle-Enhanced SiO 2 Immunoaffinity Platform
Extracellular vesicles (EVs) produced by stem cells are nanoscale carriers of bioactive compounds with regenerative and immunomodulatory capabilities similar to those of their parent cells. Their therapeutic potential outperforms traditional stem cell therapies by lowering hazards such tumorigenicity and allowing for precise delivery. To provide a high-efficiency platform for selectively isolating stem cell EVs from minimal serum quantities while overcoming the constraints of traditional approaches such as ultracentrifugation, we developed an immunoaffinity-based capture system utilizing SiO₂ wafers functionalized with gold nanoparticles (GNPs), polyethylene glycol (HS-PEG-COOH), and stem cell-specific antibodies. The platform was evaluated to isolate EVs from 20 μL serum samples. The technique efficiently and selectively isolates EVs, including stem cell-derived subtypes, with yields of up to 10⁸ particles. Western blot testing demonstrated high purity and low protein contamination, demonstrating the capture mechanism’s selectivity. This nanoparticle-enhanced platform allows for scalable, high-purity EV extraction from small sample volumes, which aids in downstream molecular analysis and therapeutic development. Its capacity to distinguish across EV subtypes has potential in personalized medicine, regenerative therapies, and non-invasive diagnostics.
- 8 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 25 (1) , 62-69
High-Yield Isolation of Stem Cell-Derived Extracellular Vesicles Using a Gold Nanoparticle-Enhanced SiO 2 Immunoaffinity Platform
Extracellular vesicles (EVs) produced by stem cells are nanoscale carriers of bioactive compounds with regenerative and immunomodulatory capabilities similar to those of their parent cells. Their therapeutic potential outperforms traditional stem cell therapies by lowering hazards such tumorigenicity and allowing for precise delivery. To provide a high-efficiency platform for selectively isolating stem cell EVs from minimal serum quantities while overcoming the constraints of traditional approaches such as ultracentrifugation, we developed an immunoaffinity-based capture system utilizing SiO₂ wafers functionalized with gold nanoparticles (GNPs), polyethylene glycol (HS-PEG-COOH), and stem cell-specific antibodies. The platform was evaluated to isolate EVs from 20 μL serum samples. The technique efficiently and selectively isolates EVs, including stem cell-derived subtypes, with yields of up to 10⁸ particles. Western blot testing demonstrated high purity and low protein contamination, demonstrating the capture mechanism’s selectivity. This nanoparticle-enhanced platform allows for scalable, high-purity EV extraction from small sample volumes, which aids in downstream molecular analysis and therapeutic development. Its capacity to distinguish across EV subtypes has potential in personalized medicine, regenerative therapies, and non-invasive diagnostics.
- 23 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (11) , 18767-18776
Exploring the Sensing Capabilities of Ti3C2TX MXene Derived C/TiO2: An Approach Toward Stable and Selective Hydrogen Gas Sensing
Titanium Carbide (Ti3C2), a 2D material discovered in 2011, has been investigated for various applications, and it’s potential as a gas sensor is exploring widely. However, to serve effectively in the field of gas sensing, it is essential to ensure long-term stability, which involves maintaining a consistent and repeatable output over time. Multiple studies have observed the degradation of MXene, particularly the surface oxidation of Ti3C2 to TiO2 in the presence of moisture, highlighting the necessity of in-depth research in this field. This work primarily focused on the stability analysis of MXene-based gas sensors. Additionally, we demonstrated that 2D layered Carbon/TiO2 (C/TiO2) structures synthesized via controlled surface oxidation of Ti3C2TX MXene at 500°C are stable as a gas sensor and can effectively detect hydrogen at low ppm levels. By utilizing this approach, the sensor achieved a remarkable response of 93% (in 65% relative humidity), with a response time of 45 s and a recovery time of 20 s at 300°C operating temperature. Furthermore, the selectivity of the prepared sample is compared with 100 ppm CO, 250 ppm NH3, and 10000 ppm CH4, indicating that oxidized MXene is a promising candidate for real-time H2 sensing. This excellent selectivity and significant sensor response to H2 make it well-suited for leak-detection applications. An attempt was also made to correlate the stable hydrogen sensing mechanism with the help of material characterization, which suggests that the oxidation of Ti3C2TX MXene to C/TiO2 leads to formation of porous, high-surface-area nanostructure which enhances gas adsorption and desorption.
- 23 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (11) , 18767-18776
Exploring the Sensing Capabilities of Ti3C2TX MXene Derived C/TiO2: An Approach Toward Stable and Selective Hydrogen Gas Sensing
Titanium Carbide (Ti3C2), a 2D material discovered in 2011, has been investigated for various applications, and it’s potential as a gas sensor is exploring widely. However, to serve effectively in the field of gas sensing, it is essential to ensure long-term stability, which involves maintaining a consistent and repeatable output over time. Multiple studies have observed the degradation of MXene, particularly the surface oxidation of Ti3C2 to TiO2 in the presence of moisture, highlighting the necessity of in-depth research in this field. This work primarily focused on the stability analysis of MXene-based gas sensors. Additionally, we demonstrated that 2D layered Carbon/TiO2 (C/TiO2) structures synthesized via controlled surface oxidation of Ti3C2TX MXene at 500°C are stable as a gas sensor and can effectively detect hydrogen at low ppm levels. By utilizing this approach, the sensor achieved a remarkable response of 93% (in 65% relative humidity), with a response time of 45 s and a recovery time of 20 s at 300°C operating temperature. Furthermore, the selectivity of the prepared sample is compared with 100 ppm CO, 250 ppm NH3, and 10000 ppm CH4, indicating that oxidized MXene is a promising candidate for real-time H2 sensing. This excellent selectivity and significant sensor response to H2 make it well-suited for leak-detection applications. An attempt was also made to correlate the stable hydrogen sensing mechanism with the help of material characterization, which suggests that the oxidation of Ti3C2TX MXene to C/TiO2 leads to formation of porous, high-surface-area nanostructure which enhances gas adsorption and desorption.
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (7) , 10566-10574
Electrochemical Impedance-Based Detection of Pancreatic Cancer Biomarker Glypican1 and Mucin1 Using Electric Field-Lysed Extracellular Vesicles for Analysis: A Proof of Concept
Glypican1 and Mucin1 antigens are prominent biomarkers for the prognosis and diagnosis of pancreatic cancer. Their presence within the extracellular vesicles (EV) opens the possibilities for oncology care through the development of minimally invasive biomarker-assisted screening tools. Traditionally, EV antigen quantification relies on ultracentrifugation and chemical lysis, which are time-consuming, equipment-dependent, and often compromise EV integrity, damaging surface intact biomarkers. This study integrates EV isolation and electric field (EF) lysis into a unified platform. The lysates were then analyzed using an electrochemical impedance spectroscopy (EIS) -based sensor to detect GPC1 and MUC1. ELISA confirms the EF lysis of the immobilized EV and shows an increase in the antigen concentration by 2.5 times (compared to pre-lysed sample). Hence, EF lysis makes the sensor more sensitive than traditional methods. To enhance the electric lysis process, we applied varying voltages of a sinusoidal signal to the SPE-immobilized EVs. The lysate was subsequently used to quantify the GPC1 and MUC1 antigens through EIS. The results indicate that a 50 mV sinusoidal signal is sufficient to effectively lyse EVs, confirmed by western blotting. The NTA results showed the successful isolation of 109 EVs from 100 μL of serum using CD63 antibody. The developed EIS sensor can detect GPC1 and MUC1 with a LOD of 0.053 pg/mL and 0.033 pg/mL respectively from EV lysate, showing minimal non-specific binding in the negative control. Beyond GPC1 and MUC1, the approach is adaptable for detecting other EV-associated biomarkers, enabling broader applications in early cancer detection and disease monitoring.
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (7) , 10566-10574
Electrochemical Impedance-Based Detection of Pancreatic Cancer Biomarker Glypican1 and Mucin1 Using Electric Field-Lysed Extracellular Vesicles for Analysis: A Proof of Concept
Glypican1 and Mucin1 antigens are prominent biomarkers for the prognosis and diagnosis of pancreatic cancer. Their presence within the extracellular vesicles (EV) opens the possibilities for oncology care through the development of minimally invasive biomarker-assisted screening tools. Traditionally, EV antigen quantification relies on ultracentrifugation and chemical lysis, which are time-consuming, equipment-dependent, and often compromise EV integrity, damaging surface intact biomarkers. This study integrates EV isolation and electric field (EF) lysis into a unified platform. The lysates were then analyzed using an electrochemical impedance spectroscopy (EIS) -based sensor to detect GPC1 and MUC1. ELISA confirms the EF lysis of the immobilized EV and shows an increase in the antigen concentration by 2.5 times (compared to pre-lysed sample). Hence, EF lysis makes the sensor more sensitive than traditional methods. To enhance the electric lysis process, we applied varying voltages of a sinusoidal signal to the SPE-immobilized EVs. The lysate was subsequently used to quantify the GPC1 and MUC1 antigens through EIS. The results indicate that a 50 mV sinusoidal signal is sufficient to effectively lyse EVs, confirmed by western blotting. The NTA results showed the successful isolation of 109 EVs from 100 μL of serum using CD63 antibody. The developed EIS sensor can detect GPC1 and MUC1 with a LOD of 0.053 pg/mL and 0.033 pg/mL respectively from EV lysate, showing minimal non-specific binding in the negative control. Beyond GPC1 and MUC1, the approach is adaptable for detecting other EV-associated biomarkers, enabling broader applications in early cancer detection and disease monitoring.
- 15 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (2) , 1-4
Electric Field-Induced Exosome Lysis and Quantification of TSG101-Derived Protein via Electrochemical Sensing
Exosomes that contain TSG101 biomarkers are synthesized by both healthy and malignant cells and have the potential to accurately diagnose a wide range of diseases, including cancer. For exosomal protein quantification, exosomes must be isolated from serum and then used for protein extraction. Ultracentrifugation is the most common way to isolate. Although detergents are commonly employed to extract the encapsulated exosomal proteins, they may compromise their protein integrity. The present work involves two detailed studies: the lysing of exosomes immobilized on the Au screen printed electrode (SPE) and the development of a nonfaradaic electrochemical sensor by utilizing SPE to quantity TSG101 protein. To lyse exosomes attached to the SPE surface, we applied different amplitudes of square signals to the SPE to disrupt the exosomes and facilitate the release of their contents. The lysate solution was utilized for electrochemical impedance spectroscopy (EIS) by faradic and nonfaradic techniques. Results of both types of EIS were similar, showing that nonfaradaic sensing could be an effective alternative. Hence, we employed nonfaradaic EIS to quantify the TSG101 protein released by electric lysis and validated the result with ELISA. We achieved a linear response, specifically at concentrations ranging from 0.125 to 8 ng/mL, with a detection limit of 0.10 ng/mL for human serum. Cross-reactivity analysis demonstrated selectivity to TSG101 with minimal interaction with nonspecific biomolecules.
- 15 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (2) , 1-4
Electric Field-Induced Exosome Lysis and Quantification of TSG101-Derived Protein via Electrochemical Sensing
Exosomes that contain TSG101 biomarkers are synthesized by both healthy and malignant cells and have the potential to accurately diagnose a wide range of diseases, including cancer. For exosomal protein quantification, exosomes must be isolated from serum and then used for protein extraction. Ultracentrifugation is the most common way to isolate. Although detergents are commonly employed to extract the encapsulated exosomal proteins, they may compromise their protein integrity. The present work involves two detailed studies: the lysing of exosomes immobilized on the Au screen printed electrode (SPE) and the development of a nonfaradaic electrochemical sensor by utilizing SPE to quantity TSG101 protein. To lyse exosomes attached to the SPE surface, we applied different amplitudes of square signals to the SPE to disrupt the exosomes and facilitate the release of their contents. The lysate solution was utilized for electrochemical impedance spectroscopy (EIS) by faradic and nonfaradic techniques. Results of both types of EIS were similar, showing that nonfaradaic sensing could be an effective alternative. Hence, we employed nonfaradaic EIS to quantify the TSG101 protein released by electric lysis and validated the result with ELISA. We achieved a linear response, specifically at concentrations ranging from 0.125 to 8 ng/mL, with a detection limit of 0.10 ng/mL for human serum. Cross-reactivity analysis demonstrated selectivity to TSG101 with minimal interaction with nonspecific biomolecules.
- 5 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (1) , 159-166
Demonstration of In₂O₃-Based Methane Sensor With Minimum Baseline Drift by Preheating and Optical Activation
Metal oxide-based gas sensors often suffer from baseline drift and selectivity. Software-based algorithms are usually used to correct errors arising from the drift phenomenon. However, the error probability will decrease if the drift can be nullified or minimized from the experiment part. This paper has conducted a detailed study to nullify the baseline drift of In 2 O 3 based CH 4 sensor by employing prolonged heating at 250°C with activation techniques. The baseline drift of the sensor was reduced to less than 1% by the technique of dual activation. The device was tested for selective sensing of CH 4 and its stability was investigated. The device reproduced the same baseline after multiple cycles of operation.
- 5 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (1) , 159-166
Demonstration of In₂O₃-Based Methane Sensor With Minimum Baseline Drift by Preheating and Optical Activation
Metal oxide-based gas sensors often suffer from baseline drift and selectivity. Software-based algorithms are usually used to correct errors arising from the drift phenomenon. However, the error probability will decrease if the drift can be nullified or minimized from the experiment part. This paper has conducted a detailed study to nullify the baseline drift of In 2 O 3 based CH 4 sensor by employing prolonged heating at 250°C with activation techniques. The baseline drift of the sensor was reduced to less than 1% by the technique of dual activation. The device was tested for selective sensing of CH 4 and its stability was investigated. The device reproduced the same baseline after multiple cycles of operation.