Mirjam Bakker-De Boo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mirjam Bakker-De Boo has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Berto Jorrit Bouma
Department of Cardiology Amsterdam University Medical Centre Amsterdam The Netherlands
2 shared publications - Jan G. Post
Department of Genetics, University Medical Centre Utrecht, Utrecht, the Netherlands
2 shared publications - Luc Cozijnsen
Department of Cardiology, Gelre Hospital, Apeldoorn, The Netherlands
2 shared publications A. M. Otten
Department of Cardiology, Gelre Hospital, Apeldoorn, The Netherlands
1 shared publication- Barbara J. M. Mulder
Center for Congenital Heart Disease Amsterdam-Leiden (CAHAL), Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Heart Centre, Amsterdam UMC, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands
1 shared publication Barbara J.M. Mulder
Department of Cardiology, Academic Medical Centre, Amsterdam, Netherlands
1 shared publication
Latest Publications
- Open Access
- 2 September 2021
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 30 (4) , 207-211
Family screening in patients with isolated bicuspid aortic valve
Aim: To determine the prevalence of undiagnosed bicuspid aortic valve (BAV) and isolated aortic dilatation in first-degree relatives (FDRs) of patients with isolated BAV and to explore the recurrence risk of BAV in different subgroups of probands with BAV. Recent American College of Cardiology (ACC)/American Heart Association (AHA) Guidelines recommend family screening in patients with associated aortopathy only. Methods: During follow-up visits, patients with isolated BAV received a printed invitation for their FDRs advising cardiac screening. Results: From 2012–2019, 257 FDRs of 118 adult BAV patients were screened, among whom 63 (53%) index patients had undergone aortic valve surgery (AVS), including concomitant aortic replacement in 25 (21%). Of the non-operated index patients, 31 (26%) had aortic dilatation (> 40 mm). Mean age of the FDRs was 48 years (range 4–83) and 42% were male. The FDR group comprised 20 parents, 103 siblings and 134 offspring. Among these FDRs, 12 (4.7%) had a previously undiagnosed BAV and 23 (8.9%) had an isolated aortic dilatation. FDRs of the probands with previous AVS (n = 147) had a risk ratio for BAV of 2.25 (95% confidence interval (CI) 0.62–8.10). FDRs of the probands with BAV and repaired or unrepaired aortic dilatation (n = 127) had a risk ratio for BAV of 0.51 (95% CI 0.16–1.66). Conclusion: Screening FDRs of patients with isolated BAV resulted in a reasonable yield of 14% new cases of BAV or isolated aortic dilatation. A trend towards an increased risk of BAV in FDRs was observed in the probands with previous AVS, whereas this risk seemed to be diminished in the probands with associated aortic dilatation. This latter finding does not support the restrictive ACC/AHA recommendation.
- 2 September 2021
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 30 (4) , 207-211
Open AccessFamily screening in patients with isolated bicuspid aortic valve
Aim: To determine the prevalence of undiagnosed bicuspid aortic valve (BAV) and isolated aortic dilatation in first-degree relatives (FDRs) of patients with isolated BAV and to explore the recurrence risk of BAV in different subgroups of probands with BAV. Recent American College of Cardiology (ACC)/American Heart Association (AHA) Guidelines recommend family screening in patients with associated aortopathy only. Methods: During follow-up visits, patients with isolated BAV received a printed invitation for their FDRs advising cardiac screening. Results: From 2012–2019, 257 FDRs of 118 adult BAV patients were screened, among whom 63 (53%) index patients had undergone aortic valve surgery (AVS), including concomitant aortic replacement in 25 (21%). Of the non-operated index patients, 31 (26%) had aortic dilatation (> 40 mm). Mean age of the FDRs was 48 years (range 4–83) and 42% were male. The FDR group comprised 20 parents, 103 siblings and 134 offspring. Among these FDRs, 12 (4.7%) had a previously undiagnosed BAV and 23 (8.9%) had an isolated aortic dilatation. FDRs of the probands with previous AVS (n = 147) had a risk ratio for BAV of 2.25 (95% confidence interval (CI) 0.62–8.10). FDRs of the probands with BAV and repaired or unrepaired aortic dilatation (n = 127) had a risk ratio for BAV of 0.51 (95% CI 0.16–1.66). Conclusion: Screening FDRs of patients with isolated BAV resulted in a reasonable yield of 14% new cases of BAV or isolated aortic dilatation. A trend towards an increased risk of BAV in FDRs was observed in the probands with previous AVS, whereas this risk seemed to be diminished in the probands with associated aortic dilatation. This latter finding does not support the restrictive ACC/AHA recommendation.
- 1 March 2018
- Published by Elsevier in International Journal of Cardiology
- Vol. 255, 55-58
Yield of family screening in patients with isolated bicuspid aortic valve in a general hospital
- 1 March 2018
- Published by Elsevier in International Journal of Cardiology
- Vol. 255, 55-58
Yield of family screening in patients with isolated bicuspid aortic valve in a general hospital
- 14 July 2003
- Published by Wiley in Echocardiography
- Vol. 20 (6) , 545-555
Real‐Time Perfusion Imaging: A New Echocardiographic Technique for Simultaneous Evaluation of Myocardial Perfusion and Contraction
Myocardial contrast echocardiography (MCE) with high acoustic energy and triggered harmonic imaging is the best established ultrasound technique to date for the assessment of myocardial perfusion. With this technique, however, the ultimate goal of MCE (noninvasive real‐time simultaneous assessment of myocardial perfusion and function after an intravenous injection of microbubbles) is not met. Recently, technologic advances have enabled myocardial opacification to be visualized during low‐energy real‐time imaging. During real‐time perfusion imaging, wall motion and myocardial perfusion may be assessed simultaneously, obviating the need of the presently time‐consuming combination of different imaging modalities. When high‐energy ultrasound bursts are periodically transmitted to produce bubble destruction during low‐power imaging, the consecutive frames after destruction delineate the restoration of contrast intensity. Microbubble replenishment rate and peak intensity may be determined subsequently, and provide reliable quantitative parameters of regional microcirculatory flow. This review will introduce the modalities used for real‐time perfusion imaging with focus on power pulse inversion imaging and quantitative analysis. Furthermore, we will describe the clinical role the technique may have in the identification of coronary artery disease, quantification of coronary stenosis severity, assessment of myocardial viability, determination of infarction size, and evaluation of reflow and no‐ or low‐reflow after acute myocardial infarction. (ECHOCARDIOGRAPHY, Volume 20, August 2003)
- 14 July 2003
- Published by Wiley in Echocardiography
- Vol. 20 (6) , 545-555
Real‐Time Perfusion Imaging: A New Echocardiographic Technique for Simultaneous Evaluation of Myocardial Perfusion and Contraction
Myocardial contrast echocardiography (MCE) with high acoustic energy and triggered harmonic imaging is the best established ultrasound technique to date for the assessment of myocardial perfusion. With this technique, however, the ultimate goal of MCE (noninvasive real‐time simultaneous assessment of myocardial perfusion and function after an intravenous injection of microbubbles) is not met. Recently, technologic advances have enabled myocardial opacification to be visualized during low‐energy real‐time imaging. During real‐time perfusion imaging, wall motion and myocardial perfusion may be assessed simultaneously, obviating the need of the presently time‐consuming combination of different imaging modalities. When high‐energy ultrasound bursts are periodically transmitted to produce bubble destruction during low‐power imaging, the consecutive frames after destruction delineate the restoration of contrast intensity. Microbubble replenishment rate and peak intensity may be determined subsequently, and provide reliable quantitative parameters of regional microcirculatory flow. This review will introduce the modalities used for real‐time perfusion imaging with focus on power pulse inversion imaging and quantitative analysis. Furthermore, we will describe the clinical role the technique may have in the identification of coronary artery disease, quantification of coronary stenosis severity, assessment of myocardial viability, determination of infarction size, and evaluation of reflow and no‐ or low‐reflow after acute myocardial infarction. (ECHOCARDIOGRAPHY, Volume 20, August 2003)