ZSZia Saadatnia

Zia Saadatnia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zia Saadatnia has a total of 34 co-authors. Here are the top co-authors by number of shared publications:

  • Hani E. Naguib

    Department of Mechanical and Industrial Engineering, University of Toronto, 5 King’s College Road, Toronto, Ontario M5S 3G8, Canada

    8 shared publications
  • Chul B. Park

    Microcellular Plastics Manufacturing Laboratory, Department of Mechanical and Industrial Engineering, University of Toronto, 5 King’s College Road, Toronto, Ontario M5S 3G8, Canada

    2 shared publications
  • Ebrahim Esmailzadeh

    Faculty of Engineering and Applied Science; University of Ontario Institute of Technology; 2000 Simcoe St. N. Oshawa Ontario L1H 7K4 Canada

    2 shared publications
  • Ehsan Asadi

    Department of Mechanical and Mechatronics Engineering; University of Waterloo; 200 University Ave. West Waterloo ON N2L 3G1 Canada

    2 shared publications
  • Hassan Askari

    Department of Mechanical and Mechatronics Engineering; University of Waterloo; 200 University Ave. West Waterloo ON N2L 3G1 Canada

    2 shared publications
  • Mohammad M. Rastegardoost

    Department of Mechanical and Industrial Engineering, University of Toronto, 5 King’s College Rd, Toronto, ON M5S 3G8, Canada

    2 shared publications

Latest Publications

  • Machine learning in Aerogels: from performance analytics to design optimization and property prediction

    by Zahra Amiri, Omid Aghababaei Tafreshi, Hangyu Song, Zia Saadatnia, Chul B. Park, Hani E. Naguib


  • Open Access

    Nonlinear behavior of a three-dimensional chiral mechanical metamaterial with compression-twist coupling

    by Siros Khorshidi, Zia Saadatnia

    Due to their tunable mechanical properties and broad applicability, three dimensional compressible–twistable mechanical metamaterials (3D-CTMM) have attracted significant attention in recent years. While the recent research on these configurations is limited to linear mechanical behavior analysis, the nonlinear characteristics of these metamaterials are crucial in practical applications such as adaptive vibration isolation, impact protection, and energy harvesting. This study introduces a combined nonlinear stress–strain relationship and strain-energy-based analytical framework, supported by finite-element analysis and experimental validation for investigating the nonlinear mechanical load-deformation behavior of a 3D-CTMM, with potential applicability to a broader class of the 3D-CTMM designs. The constitutive model and coupled load-deformation and load-torsion responses of the unit cells are investigated by incorporating the intrinsic material nonlinearity and complementary strain energy theory into the analysis and then expanded to the overall phase of the 3D-CTMM. The accuracy of the mechanical modeling is evaluated through both numerical simulations and experimental characterization. The results demonstrate strong agreement across the multiscale analyses and reveal pronounced nonlinear behavior in the deformation responses particularly in relatively high global strain values of up to 16 % . The nonlinear behavior suggests that the conventional assumption of constant Young’s modulus and Poisson’s ratio for the overall phase of the 3D-CTMM may not fully capture the response, as these parameters vary with nonlinearity and depend on the number of unit cells in the configuration. Furthermore, as a tangible application, the capability of the studied 3D-CTMM to absorb impact energy is also presented where a 3 × 3 × 3 assembly fabricated by thermoplastic polyurethane exhibits superior potential for absorbing impact energy.


  • Open Access

    Insights into the crystallization, topographical, and tribological properties of sustainable PEO-mica based triboelectric nanogenerators

    by Aliesha D Johnson, Nima Barri, Meysam Salari, Sara Mohseni Taromsari, Mohammad M Rastegardoost, Tobin Filleter, Zia Saadatnia, Hani E Naguib

    Contact electrification is the primary mechanism dictating electron transfer and surface charge density for triboelectric nanogenerators (TENGs), making intrinsic material and physical surface properties key parameters for the interfacial charge transfer phenomena. Surface properties are governed by the morphological and textural microstructural features, including tribological interactions, topographical profiling, surface roughness, and real contact area. Therefore, understanding surface morphological effects on the triboelectric performance aids development towards adapting and optimizing surface properties. Particularly, in polymer-based composites TENGs, the surface morphology relies on polymer crystallization and interactions with reinforcing additives. This comprehensive study evaluated the effects of isothermal crystallization and the incorporation and dispersibility of raw and few-layer exfoliated muscovite mica fillers, insightfully realizing and tuning polyethylene oxide’s intrinsic properties and semi-crystalline microstructure. The full material characterization presented dramatic variations in polymer growth kinetics, chain dynamics, lamellae profiling, surface roughness, and work functions, allowing the development of a constructive triboelectric surface microstructural design guide. The crystallization temperature of 65 °C with raw mica demonstrated the greatest dielectric properties and triboelectric performance resulting in a peak-to-peak voltage, peak-to-peak current density, transferred charge density, and power density of respectively, 488 V, 45.5 mA m−2, 152 μC m−2, and 24.0 W m−2 at a load resistance of 6 MΩ. The TENG device demonstrated stable long-term voltage outputs over the duration of 12 000 contact-separation cycles and successfully self-powered natural resource environmental monitoring sensors.


  • Polyimide Aerogel Fiber Bundles for Extreme Thermal Management Systems in Aerospace Applications

    by Omid Aghababaei Tafreshi, Zia Saadatnia, Shahriar Ghaffari-Mosanenzadeh, Mohammad Mahdi Rastegardoost, Changxing Zhang, Chul B. Park, Hani E. Naguib

    Aerogel fibers are an emerging class of ultralightweight materials, which, compared to conventional bulk monolithic and aerogel films, provide better flexibility and extensibility. Despite the recent advancements in this field, due to their highly porous structure, their mechanical properties can be deteriorated. Inspired by the textile industry, we report the development of aerogel fiber bundles with twisted structures as a promising strategy to enhance the mechanical performance and practicality of aerogel fibers. Polyimide (PI) aerogel fibers were prepared via the sol-gel confined transition method. The fibers showed a unique nanostructured assembly with high specific surface area, excellent optical transparency, outstanding flexibility at diverse extreme conditions, self-extinguishing behavior, and superior thermal insulation performance. Using PI aerogel fibers as the backbone, aerogel fiber bundles in various configurations were designed and fabricated. A systematic study was performed to analyze the effect of design parameters on the mechanical performance of the bundles. Results revealed an optimal twist level for bundles, leading to a peak in mechanical properties across various bundle configurations. The observed improvement in mechanical properties was attributed to increased fiber-to-fiber binding strength, enhanced friction, and interlocking mechanism of fibers, underscoring the potential of the optimized twist level for enhancing the performance of aerogel fiber bundles. Overall, the development of aerogel fiber bundles holds great promise in revolutionizing the production of high-performance ultralightweight materials for thermal management applications.


  • Open Access

    Development of an Aerogel-Based Wet Electrode for Functional Electrical Stimulation

    by Melissa Marquez-Chin, Zia Saadatnia, Hani E. Naguib, Milos R. Popovic

    Functional electrical stimulation (FES) has been a useful therapeutic tool in rehabilitation, particularly for people with paralysis. To deliver stimulation in its most basic setup, a stimulator and at least a pair of electrodes are needed. The electrodes are an essential part of the system since they allow the transduction of the stimulator signals into the body. Their performance can influence the experience of both patient and therapist in terms of movement generation, comfort, and ease of use. For non-invasive surface stimulation, current electrode options have several limitations involving their interfacing with the skin, practical inconveniences, and short-term functionality. Standard hydrogel electrodes tend to lose their adhesion with the skin quickly, while dry or textile electrodes require constant wetting to be comfortable. In this paper, we present the fabrication, characterization, and FES testing of a new aerogel-based wet electrode for surface stimulation applications for long-term and reusable FES applications. We investigated its functionality by stimulating the biceps brachii of twelve healthy individuals and collected elbow joint torque and comfort ratings for three different intensity levels (low, moderate, and high) of FES. Comparing to standard hydrogel electrodes, no statistically significant difference was found for any intensity of stimulation in either torque or comfort. Overall, the new aerogel-based electrode has an appropriate impedance, is flexible and soft, is conformable to the skin, has a high water absorption and retention, and can be used for FES purposes.


  • Open Access

    Nonlinear Vibration Analysis of Curved Piezoelectric-Layered Nanotube Resonator

    by Zia Saadatnia

    Piezoelectric-based nano resonators are smart structures that can be used for mechanical sensors and actuators in miniature systems. In this study, the nonlinear vibration behavior of a curved piezoelectric-layered nanotube resonator was investigated. The curved structure comprises a core nanotube and a slender layer of piezoelectric material covering the inner nanotube where a harmonic voltage is applied to the piezoelectric layer. Applying the energy method and Hamiltonian principle in association with non-local theories, the governing equations of motion of the targeted system are obtained. Then, the problem is solved using the Galerkin and multiple scales methods, and the system responses under external excitation and parametric load are found. Various resonance conditions are investigated including primary and parametric resonances, and the frequency responses are obtained considering steady state motions. The effects of different parameters such as applied voltage, piezoelectric thickness, and structural curvature on the system responses are investigated. It is shown that the applied harmonic voltage to the piezoelectric layer can cause a parametric resonance in the structural vibration, and the applied harmonic point load to the structure can cause a primary resonance in the vibration response. Considering two structural curvatures including quadratic and cubic curves, it is also found that the waviness and curve shape parameters can tune the nonlinear hardening and softening behaviors of the system and at specific curve shapes, the vibration response of the targeted structure acts similar to that of a linear system. This study can be targeted toward the design of curved piezoelectric nano-resonators in small-scale sensing and actuation systems.


  • Novel, Flexible, and Ultrathin Pressure Feedback Sensor for Miniaturized Intraventricular Neurosurgery Robotic Tools

    by Tianhao Chen, Zia Saadatnia, Jongwoo Kim, Thomas Looi, James Drake, Eric Diller, Hani E. Naguib

    Remote-controlled minimally invasive neuroendoscopic robotic surgical tools can be miniaturized to a size of less than 2 mm while maintaining their dexterity and force required to perform operations in brain without an open-skull surgery. However, these platforms lack haptic information to be received by the surgeons, leading to loss of control over tissue and causing unexpected slippage and trauma. This study presents the design of small and highly sensitive material-based sensor being integrated to the tool shaft, known as the concentric tube manipulators, to achieve static and quasi-static force sensing and feedback. Through a 9-element design and contact mechanics modelling, the sensor system can generate real-time polar visual pressure profile displays. Optimizations were performed on the sub-components of the sensor design including microstructures and electrodes to improve detection threshold with reduced hysteresis. The finalized design can sense a force from as low as 14.8 ± 1.22 mN to 1 N with excellent proportionality between the acquired signal and force applied while retaining its flexibility and sterilizability. The sensor will also enhance more intuitive force feedback for surgeons to use the dexterous neurosurgical tool, ensuring safety and quality of operations for minimally invasive surgeries for brain tumor and epilepsy practice.


  • Flexible, Air Dryable, and Fiber Modified Aerogel-Based Wet Electrode for Electrophysiological Monitoring

    by Zia Saadatnia, Shahriar GhaffariMosanenzadeh, Melissa Marquez Chin, Hani E. Naguib, Milos R. Popovic

    This study presents a novel type of wet electrode material for electrophysiological monitoring based on a conductive aerogel film. The electrode material incorporates cellulose nanocrystal and fiber as a biocompatible polymer and multi-walled carbon nanotube as a conductive filler. The fabricated electrode is fully characterized to explore the chemical, mechanical, electrical, and water absorption properties. The wet aerogel film presents suitable mechanical flexibility owing to the use of fiber enabling it to be conformal to curved surfaces like human body. The water absorption percentage of the fabricated aerogel film is extremely high (~500%) due to the porosity of the film and hydrophilicity of the base polymer allowing it for effective wet electrode applications. The film is air dryable with a fast (~10 min) and facile wetting process granting the electrode application for long-term, multiple use, and remote monitoring of patients. The electrical impedance range of the fabricated aerogel electrodes is relatively low (20 /cm2-370 /cm2) which is within the range of use for various electrophysiological monitoring purposes such as electrocardiography (ECG) and electroencephalography (EEG). Overall, the presented study introduces a novel wet electrode based on porous and electrically conductive aerogel film to be used for various biomedical applications.