Qijing Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qijing Lin has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Zhuangde Jiang
State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, China
5 shared publications - Libo Zhao
School of Instrument Science and Technology, Xi’an Jiaotong University, Xi’an, China
2 shared publications - Bian Tian
State Key Laboratory for Mechanical Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an, China
1 shared publication - Bin Sun
China Mobile (Hangzhou) Information Technology Co., Ltd., Hangzhou 311100, China
1 shared publication Changsheng Li
1 shared publicationChengwei Kang
1 shared publication
Latest Publications
- Open Access
- 9 January 2026
- Published by MDPI AG in Nanomaterials
- Vol. 16 (2) , 89
Miniaturized High-Speed FBG Interrogator Based on a Photonic AWG Chip
Although AWGs are widely used in FBG interrogation systems, conventional interrogators are often bulky and hard to deploy, limiting their use in complex field environments. Here, we developed an FBG interrogator based on a photonic AWG chip, comprising a photonic chip module, an optoelectronic detection and processing module, and an output interface module. The AWG chip measures only 280 µm × 150 µm, while the entire interrogator measures just 160 mm × 100 mm × 80 mm, achieving system miniaturization. Wavelength interrogation tests show that the FBG interrogator achieves a wavelength accuracy of 9.87 pm and a high-speed sampling rate of up to 10 kHz, enabling high-precision, real-time FBG demodulation under rapidly varying temperatures. Furthermore, the interrogator was subjected to engineering validation, with dynamic FBG wavelength demodulation experiments conducted under high-temperature shocks in a turbo-engine, verifying its reliability under extreme conditions and demonstrating its potential for broader engineering applications.
- 9 January 2026
- Published by MDPI AG in Nanomaterials
- Vol. 16 (2) , 89
Open AccessMiniaturized High-Speed FBG Interrogator Based on a Photonic AWG Chip
Although AWGs are widely used in FBG interrogation systems, conventional interrogators are often bulky and hard to deploy, limiting their use in complex field environments. Here, we developed an FBG interrogator based on a photonic AWG chip, comprising a photonic chip module, an optoelectronic detection and processing module, and an output interface module. The AWG chip measures only 280 µm × 150 µm, while the entire interrogator measures just 160 mm × 100 mm × 80 mm, achieving system miniaturization. Wavelength interrogation tests show that the FBG interrogator achieves a wavelength accuracy of 9.87 pm and a high-speed sampling rate of up to 10 kHz, enabling high-precision, real-time FBG demodulation under rapidly varying temperatures. Furthermore, the interrogator was subjected to engineering validation, with dynamic FBG wavelength demodulation experiments conducted under high-temperature shocks in a turbo-engine, verifying its reliability under extreme conditions and demonstrating its potential for broader engineering applications.
- Open Access
- 9 May 2024
- Published by Springer Nature in Research Square
High-Precision Continuous FBG Interrogator based on an AWG
Although arrayed waveguide gratings (AWGs) are widely used in fibre Bragg grating (FBG) demodulation systems, their applications in real environments have been limited due to their narrow dynamic range and inability to continuously demodulate FBGs because of the finite bandwidth of AWG channels. Here, we developed a wide-dynamic-range, high-precision, continuous-demodulation FBG interrogator utilizing a dual-input channel on-chip silicon AWG. The introduction of two input channels in the AWG allowed two spectral peaks in each channel; therefore, staggered spectral peaks were realized. A joint-peak demodulation method based on this spectrum is proposed to improve the dynamic range and demodulation precision. With the proposed structure and method, we achieved continuous interrogation with a demodulation precision of 25.58 pm and a dynamic range of 24.5 nm in the 1537.5-1565.3 nm wavelength region. The relative demodulation accuracy within the full range reaches 0.1%. The dynamic range of adjacent channels is 5.4 nm, which is approximately 4 times greater than the dynamic range of an FBG conventional demodulation system using an AWG, and the relative demodulation accuracy is 0.47%. To our knowledge, the relative demodulation accuracy is currently the highest reported. This developed interrogator, with a core size of 420 µm × 300 µm, theoretically explained and experimentally verified the possibility of the accurate measurement of an arbitrary FBG wavelength with high demodulation accuracy in the measurement range. This work achieved continuous monitoring of external temperature by FBGs and demonstrated their significant potential in expanding the application field of FBGs.
- 9 May 2024
- Published by Springer Nature in Research Square
Open AccessHigh-Precision Continuous FBG Interrogator based on an AWG
Although arrayed waveguide gratings (AWGs) are widely used in fibre Bragg grating (FBG) demodulation systems, their applications in real environments have been limited due to their narrow dynamic range and inability to continuously demodulate FBGs because of the finite bandwidth of AWG channels. Here, we developed a wide-dynamic-range, high-precision, continuous-demodulation FBG interrogator utilizing a dual-input channel on-chip silicon AWG. The introduction of two input channels in the AWG allowed two spectral peaks in each channel; therefore, staggered spectral peaks were realized. A joint-peak demodulation method based on this spectrum is proposed to improve the dynamic range and demodulation precision. With the proposed structure and method, we achieved continuous interrogation with a demodulation precision of 25.58 pm and a dynamic range of 24.5 nm in the 1537.5-1565.3 nm wavelength region. The relative demodulation accuracy within the full range reaches 0.1%. The dynamic range of adjacent channels is 5.4 nm, which is approximately 4 times greater than the dynamic range of an FBG conventional demodulation system using an AWG, and the relative demodulation accuracy is 0.47%. To our knowledge, the relative demodulation accuracy is currently the highest reported. This developed interrogator, with a core size of 420 µm × 300 µm, theoretically explained and experimentally verified the possibility of the accurate measurement of an arbitrary FBG wavelength with high demodulation accuracy in the measurement range. This work achieved continuous monitoring of external temperature by FBGs and demonstrated their significant potential in expanding the application field of FBGs.
- 1 January 2023
- Published by China Engineering Science Press Co. Ltd. in Strategic Study of CAE
- Vol. 25 (1) , 131
Ultra-Precision Machining Technology and Equipment for High-End Optical Elements
Optical element; precision manufacturing; ultra-precision machine tool; ultra-precision machining; optical fabrication
- 1 January 2023
- Published by China Engineering Science Press Co. Ltd. in Strategic Study of CAE
- Vol. 25 (1) , 131
Ultra-Precision Machining Technology and Equipment for High-End Optical Elements
Optical element; precision manufacturing; ultra-precision machine tool; ultra-precision machining; optical fabrication
- Open Access
- 24 June 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (7) , 995
High-Precision Regulation of Nano-Grating Linewidth Based on ALD
A nano-grating standard with accurate linewidth can not only calibrate the magnification of nano-measurement instruments, but can also enable comparison of linewidths. Unfortunately, it is still a challenging task to control the linewidth of nano-grating standards. Accordingly, in this paper, atomic layer deposition (ALD) was used to regulate the linewidth of the one-dimensional grating standards with a pitch of 1000 nm, fabricated by electron beam lithography (EBL). The standards were measured using an atomic force microscope (AFM) before and after ALD, and the linewidth and pitch of the grating were calculated through the gravity center method. The obtained results prove that the width of a single grating line in the standard can be regulated with great uniformity by precisely utilizing ALD. Meanwhile, the proposed method does not affect the pitch of grating, and the measurement uncertainty of standards is less than 0.16% of the pitch, thereby demonstrating a high surface quality and calibration reliability of the standards, and realizing the integration of linewidth and pitch calibration functions. Moreover, the precise and controllable fabrication method of the micro-nano periodic structure based on ALD technology has many potential applications in the fields of optoelectronic devices and biosensors.
- 24 June 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (7) , 995
Open AccessHigh-Precision Regulation of Nano-Grating Linewidth Based on ALD
A nano-grating standard with accurate linewidth can not only calibrate the magnification of nano-measurement instruments, but can also enable comparison of linewidths. Unfortunately, it is still a challenging task to control the linewidth of nano-grating standards. Accordingly, in this paper, atomic layer deposition (ALD) was used to regulate the linewidth of the one-dimensional grating standards with a pitch of 1000 nm, fabricated by electron beam lithography (EBL). The standards were measured using an atomic force microscope (AFM) before and after ALD, and the linewidth and pitch of the grating were calculated through the gravity center method. The obtained results prove that the width of a single grating line in the standard can be regulated with great uniformity by precisely utilizing ALD. Meanwhile, the proposed method does not affect the pitch of grating, and the measurement uncertainty of standards is less than 0.16% of the pitch, thereby demonstrating a high surface quality and calibration reliability of the standards, and realizing the integration of linewidth and pitch calibration functions. Moreover, the precise and controllable fabrication method of the micro-nano periodic structure based on ALD technology has many potential applications in the fields of optoelectronic devices and biosensors.
- Open Access
- 7 July 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (7) , 664
Effect of Annealing on the Thermoelectricity Properties of the WRe26-In2O3 Thin Film Thermocouples
WRe26-In2O3 (WRe26 (tungsten-26% rhenium) and In2O3 thermoelectric materials) thin film thermocouples (TFTCs) have been fabricated based on magnetron sputtering technology, which can be used in temperature measurement. Many annealing processes were studied to promote the sensitivity of WRe26-In2O3 TFTCs. The optimal annealing process of the thermocouple under this kind of RF magnetron sputtering method was proposed after analyzing the properties of In2O3 films and the thermoelectric voltage of TFTCs at different annealing processes. The calibration results showed that the WRe26-In2O3 TFTCs achieved a thermoelectric voltage of 123.6 mV at a temperature difference of 612.9 K, with a sensitivity of up to 201.6 µV/K. Also, TFTC kept a stable thermoelectric voltage output at 973 K for 20 min and at 773 K for two hours. In general, the WRe26-In2O3 TFTCs developed in this work have great potential for practical applications. In future work, we will focus on the thermoelectric stability of TFTCs at higher temperatures.
- 7 July 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (7) , 664
Open AccessEffect of Annealing on the Thermoelectricity Properties of the WRe26-In2O3 Thin Film Thermocouples
WRe26-In2O3 (WRe26 (tungsten-26% rhenium) and In2O3 thermoelectric materials) thin film thermocouples (TFTCs) have been fabricated based on magnetron sputtering technology, which can be used in temperature measurement. Many annealing processes were studied to promote the sensitivity of WRe26-In2O3 TFTCs. The optimal annealing process of the thermocouple under this kind of RF magnetron sputtering method was proposed after analyzing the properties of In2O3 films and the thermoelectric voltage of TFTCs at different annealing processes. The calibration results showed that the WRe26-In2O3 TFTCs achieved a thermoelectric voltage of 123.6 mV at a temperature difference of 612.9 K, with a sensitivity of up to 201.6 µV/K. Also, TFTC kept a stable thermoelectric voltage output at 973 K for 20 min and at 773 K for two hours. In general, the WRe26-In2O3 TFTCs developed in this work have great potential for practical applications. In future work, we will focus on the thermoelectric stability of TFTCs at higher temperatures.
- Open Access
- 1 December 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (12) , 125003
Broadband vibration energy harvesting for wireless sensor node power supply in train container
Wireless sensor nodes (WSNs) for temperature and humidity monitoring are commonly used in a cold chain logistics container. Energy harvesting technology is expected to realize the sustainable self-power supply for the WSN. Low amplitude and broadband vibration energy harvesting performance are the key points in train application. In this study, two piezoelectric vibration energy harvesters (PVEHs) are designed and simulated via COMSOL. Their low resonant frequencies and high electromechanical sensitivities are realized by big L-shaped mass blocks with different material densities. Their broadband vibration energy harvesting performance is achieved by the stopper and series connection. Experimental data are shown at an acceleration of 0.5 m/s2; PVEH-1 and PVEH-2 have maximum powers of 0.24 mW and 0.1 mW when excited at the resonant frequencies of 13.1 Hz and 18.8 Hz, respectively, and they both have the optimal load resistance of 40 kΩ. Two circuit design styles of two PVEHs, independent and series styles, are proposed for broadband vibration energy harvesting. Experimental results show that the series style has a wider operating frequency bandwidth and shorter charging time. Two PVEHs in series style can be effectively used for power supply of the temperature and humidity WSN in the broadband frequency range of 8.7–22.0 Hz above charging root mean square voltage of 5 V at the acceleration of 3.0 m/s2. This scheme is promised to be applied to the cold chain logistics train container.
- 1 December 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (12) , 125003
Open AccessBroadband vibration energy harvesting for wireless sensor node power supply in train container
Wireless sensor nodes (WSNs) for temperature and humidity monitoring are commonly used in a cold chain logistics container. Energy harvesting technology is expected to realize the sustainable self-power supply for the WSN. Low amplitude and broadband vibration energy harvesting performance are the key points in train application. In this study, two piezoelectric vibration energy harvesters (PVEHs) are designed and simulated via COMSOL. Their low resonant frequencies and high electromechanical sensitivities are realized by big L-shaped mass blocks with different material densities. Their broadband vibration energy harvesting performance is achieved by the stopper and series connection. Experimental data are shown at an acceleration of 0.5 m/s2; PVEH-1 and PVEH-2 have maximum powers of 0.24 mW and 0.1 mW when excited at the resonant frequencies of 13.1 Hz and 18.8 Hz, respectively, and they both have the optimal load resistance of 40 kΩ. Two circuit design styles of two PVEHs, independent and series styles, are proposed for broadband vibration energy harvesting. Experimental results show that the series style has a wider operating frequency bandwidth and shorter charging time. Two PVEHs in series style can be effectively used for power supply of the temperature and humidity WSN in the broadband frequency range of 8.7–22.0 Hz above charging root mean square voltage of 5 V at the acceleration of 3.0 m/s2. This scheme is promised to be applied to the cold chain logistics train container.