Narendra H. Petha
Research Subjects
Research Interests
Narendra H. Petha has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Devender T. Seshadri
Indofil Industries Limited, India
2 shared publications Jitendra G. Patil
Indofil Industries Limited, India
1 shared publicationRaju M. Patil
1 shared publication- Raju M. Patil
Institute of Science, Mumbai, India
1 shared publication Rama S. Lokhande
1 shared publication- Rama Sadashiv Lokhande
Department of Chemistry, Jaipur National University, Jaipur, 302017, India
1 shared publication
Latest Publications
- 1 October 2017
- Published by Elsevier in Polymer Testing
- Vol. 63, 462-466
Determination of residual (free) monomer in water based polymer emulsions by head space gas chromatography mass spectrometry
- 1 October 2017
- Published by Elsevier in Polymer Testing
- Vol. 63, 462-466
Determination of residual (free) monomer in water based polymer emulsions by head space gas chromatography mass spectrometry
- 2 August 2017
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 9 (32) , 4702-4708
A simple pre-column derivatization method for the determination of mancozeb technical (fungicide) by reverse phase HPLC-UV
A simple and fast pre-column derivatization high performance liquid chromatographic method for the technical analysis of mancozeb was developed and validated in the present study. The mobile phase consists of a mixture of acetonitrile and 0.1% (v/v) formic acid in the proportion 60 : 40. This was found to give a sharp peak of the S-ethyl derivative of mancozeb (S-ethyl ethylene bis-dithiocarbamate) at a retention time of 9.12 minutes. HPLC analysis of mancozeb was carried out at a wavelength of 272 nm with a flow rate of 1.0 mL per minute. The linear regression analysis data for the calibration curve showed a good linear relationship with a regression coefficient of 0.999 in the concentration range of 8.2 mg L−1 to 32.3 mg L−1 for the derivative of mancozeb technical. The method was validated for specificity, linearity, precision and accuracy.
- 2 August 2017
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 9 (32) , 4702-4708
A simple pre-column derivatization method for the determination of mancozeb technical (fungicide) by reverse phase HPLC-UV
A simple and fast pre-column derivatization high performance liquid chromatographic method for the technical analysis of mancozeb was developed and validated in the present study. The mobile phase consists of a mixture of acetonitrile and 0.1% (v/v) formic acid in the proportion 60 : 40. This was found to give a sharp peak of the S-ethyl derivative of mancozeb (S-ethyl ethylene bis-dithiocarbamate) at a retention time of 9.12 minutes. HPLC analysis of mancozeb was carried out at a wavelength of 272 nm with a flow rate of 1.0 mL per minute. The linear regression analysis data for the calibration curve showed a good linear relationship with a regression coefficient of 0.999 in the concentration range of 8.2 mg L−1 to 32.3 mg L−1 for the derivative of mancozeb technical. The method was validated for specificity, linearity, precision and accuracy.