RTRenata Trevelin

Renata Trevelin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Renata Trevelin has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Anselmo Soeiro Pereira

    Mines Paris, PSL University, Centre for material forming (CEMEF), UMR CNRS 7635, rue Claude Daunesse, 06904 Sophia-Antipolis, France

    1 shared publication
  • Edson José Soares

    LABREO, Department of Mechanical Engineering, Universidade Federal do Espirito Santo 4 , Avenida Fernando Ferrari, 514, Goiabeiras, Vitória, ES 29075-910

    1 shared publication
  • Fabrício Thomaz

    FCA LATAM, Universidade Federal de Minas Gerais

    1 shared publication
  • Gustavo A. B. Sandoval

    Universidade Federal do Espirito Santo LabReo, Department of Mechanical Engineering Avenida Fernando Ferrari, 514, Goiabeiras, Vitoria, 29075-910 ES, Brazil

    1 shared publication
  • Lucas Silveira

    Universidade Federal do Espirito Santo LabReo, Department of Mechanical Engineering Avenida Fernando Ferrari, 514, Goiabeiras, Vitoria, 29075-910 ES, Brazil

    1 shared publication

Latest Publications

  • Loss of efficiency of polymeric drag reducers induced by high Reynolds number flows in tubes with imposed pressure

    by Edson J. Soares, Gustavo A. B. Sandoval, Lucas Silveira, Anselmo S. Pereira, Renata Trevelin, Fabricio Thomaz

    This paper studies the loss of efficiency of polymeric drag reducers induced by high Reynolds number flows in tubes. The overall pressure was fixed and the apparatus was built so as to minimize the polymer degradation. We used three kinds of polymers: two flexible and one rigid. We conducted our tests to take into account the drag reduction (DR) for a wide range of concentrations of each polymer. The main results are displayed for the DR as a function of the number of passes through the apparatus. The mechanism of the loss of efficiency for the Xanthan Gum (XG) solutions (the rigid one) seems to be completely different from that observed for Poly (ethylene oxide) (PEO) and Polyacrylamide (PAM) (the flexible materials). While the PEO and PAM mechanically degrade by the action of the turbulent flow, the XG seems to remain intact, even after many passes through the pipe flow apparatus. From the practical point of view, it is worth noting that the PAM solutions are clearly more efficient than the PEO and XG. Another practical point that deserves attention is concerned with the asymptotic drag reduction found for XG. Although its maximum DR was significantly smaller than that found for PEO, the final value for both polymers were quite the same, which is obviously related to the intensified mechanical molecule scission in the PEO solutions. Our results for the relative drag reduction (the current value of DR divided by its maximum obtained at the first pass) was quite well fitted by the decay function proposed in our previous paper [A. S. Pereira and E. J. Soares, “Polymer degradation of dilute solutions in turbulent drag reducing flows in a cylindrical double gap rheometer device,” J. Non-Newtonian Fluid Mech. 179, 9–22 (2012)], in which a rotating apparatus was used. This strongly suggests that the physical mechanism that governs the degradation phenomenon is independent of the geometry. We also used a degradation model for PEO proposed by Vonlanthen and Monkewitz [“Grid turbulence in dilute polymer solution: Peo in water,” J. Fluid Mech. 730, 76–98 (2013)] to fit our data of relative drag reduction for PEO and PAM.