Latest Publications
- Open Access
New Concept of Colonoscopy Assisted by a Microwave-Based Accessory Device: First Clinical Experience
Background/Objectives: Colonoscopies have some limitations that result in a miss rate detection of polyps. Microwave imaging has been demonstrated to detect colorectal polyps based on their dielectric properties in synthetic phantoms, ex vivo tissues and in vivo animal models. This study aims to evaluate, for the first time, the feasibility, safety and performance of microwave-based colonoscopy for diagnosis of polyps in real-time explorations in humans. Methods: This was a single-center, prospective, observational study. Patients referred for diagnostic colonoscopy were explored with a device with microwave antennas which was attached to the tip of a standard colonoscope. The primary outcomes were rate of cecal intubation, adverse events, mural injuries and performance metrics for the detection of polyps. Secondary outcomes were the following: patients’ subjective feedback, procedural time and perception of difficulty according to the endoscopist. Results: Fifteen patients were enrolled. Cecal intubation rate was 100%, with a mean time of 12.7 ± 4.9 min (range 4–22). Use of the device did not affect the endoscopic image, and polypectomy was successfully performed in all cases. In on scale from zero (not difficult) to four (very difficult), the maneuverability during the insertion was considered ≤2 in the 86.7% (13/15) of colonoscopies. Only 16 incidents were reported in 14 patients: 11 (67%) superficial hematomas, 2 minor rectal bleedings, 1 anal fissure, 1 rhinorrhea and 1 headache. Most of the patients (94%) reported no discomfort or minimal discomfort before discharge (Gloucester score 1 and 2, respectively). In the six patients with 23 polyps used for the performance analysis, the sensitivity and specificity were 86.9% and 72.0%, respectively. Conclusions: microwave-based colonoscopy is safe and feasible and has the potential to detect polyps in real colonoscopies.
Open AccessNew Concept of Colonoscopy Assisted by a Microwave-Based Accessory Device: First Clinical Experience
Background/Objectives: Colonoscopies have some limitations that result in a miss rate detection of polyps. Microwave imaging has been demonstrated to detect colorectal polyps based on their dielectric properties in synthetic phantoms, ex vivo tissues and in vivo animal models. This study aims to evaluate, for the first time, the feasibility, safety and performance of microwave-based colonoscopy for diagnosis of polyps in real-time explorations in humans. Methods: This was a single-center, prospective, observational study. Patients referred for diagnostic colonoscopy were explored with a device with microwave antennas which was attached to the tip of a standard colonoscope. The primary outcomes were rate of cecal intubation, adverse events, mural injuries and performance metrics for the detection of polyps. Secondary outcomes were the following: patients’ subjective feedback, procedural time and perception of difficulty according to the endoscopist. Results: Fifteen patients were enrolled. Cecal intubation rate was 100%, with a mean time of 12.7 ± 4.9 min (range 4–22). Use of the device did not affect the endoscopic image, and polypectomy was successfully performed in all cases. In on scale from zero (not difficult) to four (very difficult), the maneuverability during the insertion was considered ≤2 in the 86.7% (13/15) of colonoscopies. Only 16 incidents were reported in 14 patients: 11 (67%) superficial hematomas, 2 minor rectal bleedings, 1 anal fissure, 1 rhinorrhea and 1 headache. Most of the patients (94%) reported no discomfort or minimal discomfort before discharge (Gloucester score 1 and 2, respectively). In the six patients with 23 polyps used for the performance analysis, the sensitivity and specificity were 86.9% and 72.0%, respectively. Conclusions: microwave-based colonoscopy is safe and feasible and has the potential to detect polyps in real colonoscopies.
- Open Access
- 25 February 2025
- Published by MDPI AG in Preprints.org
New Concept of Colonoscopy Assisted by a Microwave-Based Accessory Device: First Clinical Experience
Background/Objectives: Microwave imaging can obtain anatomical and functional images of the colon and has demonstrated to detect polyps based on their dielectric properties. This study aims to evaluate the feasibility, safety and performance of micro-wave-based colonoscopy for diagnosis of polyps in humans. Methods: single-center, prospective, observational study. Patients referred for elective outpatient diagnostic co-lonoscopy were included. A device provided with microwave antennas was attached to the tip of a conventional colonoscope. The primary outcomes were rate of cecal intubation, adverse events, mural injuries and performance metrics for detection of polyps. Secondary outcomes were: patients’ subjective feedback, procedural time and perception of difficulty by the endoscopist. Results: 15 patients were enrolled. Cecal intubation rate was 100% with a mean time of 12.7±4.9 min (range 4-22). Use of the device did not affect the endoscopic image and polypectomy was successfully performed in all cases. In a scale from 0 (not difficult) to 4 (very difficult), the maneuverability during the insertion was considered < 2 in the 86.7% (13/15) of colonoscopies. Only 16 incidents were reported in 14 patients: 11 (67%) superficial hematomas, 2 minor rectal bleedings, 1 anal fissure, 1 rhinorrhea and 1 headache. Most of the patients (94%) referred no discomfort or minimal discomfort before discharge (Gloucester score 1 and 2, respectively). In the six patients with 23 polyps used for the performance analysis, the sensitivity and specificity were 86.9% and 72.0%, respectively. Conclusions: microwave-based colonoscopy is safe and feasible and has the potential of detecting polyps.
- 25 February 2025
- Published by MDPI AG in Preprints.org
Open AccessNew Concept of Colonoscopy Assisted by a Microwave-Based Accessory Device: First Clinical Experience
Background/Objectives: Microwave imaging can obtain anatomical and functional images of the colon and has demonstrated to detect polyps based on their dielectric properties. This study aims to evaluate the feasibility, safety and performance of micro-wave-based colonoscopy for diagnosis of polyps in humans. Methods: single-center, prospective, observational study. Patients referred for elective outpatient diagnostic co-lonoscopy were included. A device provided with microwave antennas was attached to the tip of a conventional colonoscope. The primary outcomes were rate of cecal intubation, adverse events, mural injuries and performance metrics for detection of polyps. Secondary outcomes were: patients’ subjective feedback, procedural time and perception of difficulty by the endoscopist. Results: 15 patients were enrolled. Cecal intubation rate was 100% with a mean time of 12.7±4.9 min (range 4-22). Use of the device did not affect the endoscopic image and polypectomy was successfully performed in all cases. In a scale from 0 (not difficult) to 4 (very difficult), the maneuverability during the insertion was considered < 2 in the 86.7% (13/15) of colonoscopies. Only 16 incidents were reported in 14 patients: 11 (67%) superficial hematomas, 2 minor rectal bleedings, 1 anal fissure, 1 rhinorrhea and 1 headache. Most of the patients (94%) referred no discomfort or minimal discomfort before discharge (Gloucester score 1 and 2, respectively). In the six patients with 23 polyps used for the performance analysis, the sensitivity and specificity were 86.9% and 72.0%, respectively. Conclusions: microwave-based colonoscopy is safe and feasible and has the potential of detecting polyps.
- 21 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 9 (2) , 214-220
Movement Tracking and False Positive Reduction Method for Microwave Colonoscopy Systems
This paper presents a novel computational method for addressing the challenge of uncontrolled antenna movement in microwave imaging systems for colonoscopy. The proposed method tracks the movement of the antenna array by analyzing phase shifts in S-parameters across multiple channels. By exploiting the symmetry of the probe and correlating phase changes with displacement, this technique reduces false positives due to probe movements artifacts in real-time. Simulated and experimental results in a colon phantom model show that this method can correct displacements of up to 6 mm, reducing the artifacts in reconstructed images notably.
- 21 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 9 (2) , 214-220
Movement Tracking and False Positive Reduction Method for Microwave Colonoscopy Systems
This paper presents a novel computational method for addressing the challenge of uncontrolled antenna movement in microwave imaging systems for colonoscopy. The proposed method tracks the movement of the antenna array by analyzing phase shifts in S-parameters across multiple channels. By exploiting the symmetry of the probe and correlating phase changes with displacement, this technique reduces false positives due to probe movements artifacts in real-time. Simulated and experimental results in a colon phantom model show that this method can correct displacements of up to 6 mm, reducing the artifacts in reconstructed images notably.
- 9 October 2023
- Published by Springer Nature
- p. 471-500
Rapid Progress in Early Detection of Colorectal Cancer Using Microwaves
- 9 October 2023
- Published by Springer Nature
- p. 471-500
Rapid Progress in Early Detection of Colorectal Cancer Using Microwaves
- Open Access
Preclinical Evaluation of a Microwave-Based Accessory Device for Colonoscopy in an In Vivo Porcine Model with Colorectal Polyps
Background and Aims: Colonoscopy is currently the most effective way of detecting colorectal cancer and removing polyps, but it has some drawbacks and can miss up to 22% of polyps. Microwave imaging has the potential to provide a 360° view of the colon and addresses some of the limitations of conventional colonoscopy. This study evaluates the feasibility of a microwave-based colonoscopy in an in vivo porcine model. Methods: A prototype device with microwave antennas attached to a conventional endoscope was tested on four healthy pigs and three gene-targeted pigs with mutations in the adenomatous polyposis coli gene. The first four animals were used to evaluate safety and maneuverability and compatibility with endoscopic tools. The ability to detect polyps was tested in a series of three gene-targeted pigs. Results: the microwave-based device did not affect endoscopic vision or cause any adverse events such as deep mural injuries. The microwave system was stable during the procedures, and the detection algorithm showed a maximum detection signal for adenomas compared with healthy mucosa. Conclusions: Microwave-based colonoscopy is feasible and safe in a preclinical model, and it has the potential to improve polyp detection. Further investigations are required to assess the device’s efficacy in humans.
Open AccessPreclinical Evaluation of a Microwave-Based Accessory Device for Colonoscopy in an In Vivo Porcine Model with Colorectal Polyps
Background and Aims: Colonoscopy is currently the most effective way of detecting colorectal cancer and removing polyps, but it has some drawbacks and can miss up to 22% of polyps. Microwave imaging has the potential to provide a 360° view of the colon and addresses some of the limitations of conventional colonoscopy. This study evaluates the feasibility of a microwave-based colonoscopy in an in vivo porcine model. Methods: A prototype device with microwave antennas attached to a conventional endoscope was tested on four healthy pigs and three gene-targeted pigs with mutations in the adenomatous polyposis coli gene. The first four animals were used to evaluate safety and maneuverability and compatibility with endoscopic tools. The ability to detect polyps was tested in a series of three gene-targeted pigs. Results: the microwave-based device did not affect endoscopic vision or cause any adverse events such as deep mural injuries. The microwave system was stable during the procedures, and the detection algorithm showed a maximum detection signal for adenomas compared with healthy mucosa. Conclusions: Microwave-based colonoscopy is feasible and safe in a preclinical model, and it has the potential to improve polyp detection. Further investigations are required to assess the device’s efficacy in humans.
- Open Access
MiWEndo: Evaluation of a Microwave Colonoscopy Algorithm for Early Colorectal Cancer Detection in Ex Vivo Human Colon Models
This study assesses the efficacy of detecting colorectal cancer precursors or polyps in an ex vivo human colon model with a microwave colonoscopy algorithm. Nowadays, 22% of polyps go undetected with conventional colonoscopy, and the risk of cancer after a negative colonoscopy can be up to 7.9%. We developed a microwave colonoscopy device that consists of a cylindrical ring-shaped switchable microwave antenna array that can be attached to the tip of a conventional colonoscope as an accessory. The accessory is connected to an external unit that allows successive measurements of the colon and processes the measurements with a microwave imaging algorithm. An acoustic signal is generated when a polyp is detected. Fifteen ex vivo freshly excised human colons with cancer (n = 12) or polyps (n = 3) were examined with the microwave-assisted colonoscopy system simulating a real colonoscopy exploration. After the experiment, the dielectric properties of the specimens were measured with a coaxial probe and the samples underwent a pathology analysis. The results show that all the neoplasms were detected with a sensitivity of 100% and specificity of 87.4%.
Open AccessMiWEndo: Evaluation of a Microwave Colonoscopy Algorithm for Early Colorectal Cancer Detection in Ex Vivo Human Colon Models
This study assesses the efficacy of detecting colorectal cancer precursors or polyps in an ex vivo human colon model with a microwave colonoscopy algorithm. Nowadays, 22% of polyps go undetected with conventional colonoscopy, and the risk of cancer after a negative colonoscopy can be up to 7.9%. We developed a microwave colonoscopy device that consists of a cylindrical ring-shaped switchable microwave antenna array that can be attached to the tip of a conventional colonoscope as an accessory. The accessory is connected to an external unit that allows successive measurements of the colon and processes the measurements with a microwave imaging algorithm. An acoustic signal is generated when a polyp is detected. Fifteen ex vivo freshly excised human colons with cancer (n = 12) or polyps (n = 3) were examined with the microwave-assisted colonoscopy system simulating a real colonoscopy exploration. After the experiment, the dielectric properties of the specimens were measured with a coaxial probe and the samples underwent a pathology analysis. The results show that all the neoplasms were detected with a sensitivity of 100% and specificity of 87.4%.
- Open Access
- 7 June 2022
- Published by MDPI AG in Preprints.org
MiWEndo: Evaluation of a Microwave Colonoscopy Algorithm for Early Colorectal Cancer Detection in Ex Vivo Human Colon Models
This study assesses the efficacy of a microwave colonoscopy algorithm to detect colorectal cancer precursors or polyps in an ex-vivo human colon model. The algorithm works with a device composed of a cylindrical ring-shaped switchable antenna array, which can be attached to the tip of a conventional colonoscope as an accessory. The accessory is connected to an external processing unit that generates an acoustic signal when a polyp is detected. Nowadays, 22% of polyps go undetected with conventional colonoscopy and the risk of cancer after a negative colonoscopy can be up to 7.9%. Fifteen ex-vivo freshly excised human colons with cancer (n=12) or polyps (n=3) were examined with the microwave-assisted colonoscopy system simulating a real colonoscopy exploration. Successive measurements of the colon were taken with the microwave-based colonoscopy device and processed with a microwave imaging algorithm. After the experiment, the dielectric properties of the specimens were measured with a coaxial probe and finally the samples underwent a pathology analysis. The results show that all the neoplasms were detected with a sensitivity of 100% and specificity of 87.4%.
- 7 June 2022
- Published by MDPI AG in Preprints.org
Open AccessMiWEndo: Evaluation of a Microwave Colonoscopy Algorithm for Early Colorectal Cancer Detection in Ex Vivo Human Colon Models
This study assesses the efficacy of a microwave colonoscopy algorithm to detect colorectal cancer precursors or polyps in an ex-vivo human colon model. The algorithm works with a device composed of a cylindrical ring-shaped switchable antenna array, which can be attached to the tip of a conventional colonoscope as an accessory. The accessory is connected to an external processing unit that generates an acoustic signal when a polyp is detected. Nowadays, 22% of polyps go undetected with conventional colonoscopy and the risk of cancer after a negative colonoscopy can be up to 7.9%. Fifteen ex-vivo freshly excised human colons with cancer (n=12) or polyps (n=3) were examined with the microwave-assisted colonoscopy system simulating a real colonoscopy exploration. Successive measurements of the colon were taken with the microwave-based colonoscopy device and processed with a microwave imaging algorithm. After the experiment, the dielectric properties of the specimens were measured with a coaxial probe and finally the samples underwent a pathology analysis. The results show that all the neoplasms were detected with a sensitivity of 100% and specificity of 87.4%.
- Open Access
- 28 January 2022
- Published by Wiley in Gastroenterology Research and Practice
- Vol. 2022, 1-5
Microwave-Based Colonoscopy: Preclinical Evaluation in an Ex Vivo Human Colon Model
Introduction. Microwave imaging can obtain 360° anatomical and functional images of the colon representing the existing contrast in dielectric properties between different tissues. Microwaves are safe (nonionizing) and have the potential of reducing the visualization problems of conventional colonoscopy. This study assessed the efficacy of a microwave-based colonoscopy device to detect neoplastic lesions in an ex vivo human colon model. Methods. Fresh surgically excised colorectal specimens containing cancer or polyps were fixed to a 3D positioning system, and the accessory device was introduced horizontally inside the ex vivo colon lumen and moved along it simulating a real colonoscopy exploration. Measurements of the colon were taken every 4 mm with the microwave-based colonoscopy device and processed with a microwave imaging algorithm. Results. 14 ex vivo human colorectal specimens with carcinomas ( ) or adenomas with high grade dysplasia ( ) were examined with a microwave-based device. Using a detection threshold of 2.79 for the dielectric property contrast, all lesions were detected without false positives or false negatives. Conclusions. This study demonstrates the use of a microwave-based device to be used as an accessory of a standard colonoscope to detect neoplastic lesions in surgically excised colorectal specimens.
- 28 January 2022
- Published by Wiley in Gastroenterology Research and Practice
- Vol. 2022, 1-5
Open AccessMicrowave-Based Colonoscopy: Preclinical Evaluation in an Ex Vivo Human Colon Model
Introduction. Microwave imaging can obtain 360° anatomical and functional images of the colon representing the existing contrast in dielectric properties between different tissues. Microwaves are safe (nonionizing) and have the potential of reducing the visualization problems of conventional colonoscopy. This study assessed the efficacy of a microwave-based colonoscopy device to detect neoplastic lesions in an ex vivo human colon model. Methods. Fresh surgically excised colorectal specimens containing cancer or polyps were fixed to a 3D positioning system, and the accessory device was introduced horizontally inside the ex vivo colon lumen and moved along it simulating a real colonoscopy exploration. Measurements of the colon were taken every 4 mm with the microwave-based colonoscopy device and processed with a microwave imaging algorithm. Results. 14 ex vivo human colorectal specimens with carcinomas ( ) or adenomas with high grade dysplasia ( ) were examined with a microwave-based device. Using a detection threshold of 2.79 for the dielectric property contrast, all lesions were detected without false positives or false negatives. Conclusions. This study demonstrates the use of a microwave-based device to be used as an accessory of a standard colonoscope to detect neoplastic lesions in surgically excised colorectal specimens.
- Open Access
- 28 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 148048-148059
Automatic Polyp Detection Using Microwave Endoscopy for Colorectal Cancer Prevention and Early Detection: Phantom Validation
A system to integrate microwave imaging with optical colonoscopy is presented. The overarching goal is to improve the prevention and early diagnosis of one of the main health and economic burdens of an increasingly aging population, i.e., colorectal cancer. For a colonoscopy, the gold standard for colorectal cancer diagnosis, 22% of polyps are not detected, and the risk of cancer after a negative colonoscopy can be up to 7.9%. To remedy this, a microwave imaging system able to generate an alarm when a polyp is detected is designed, manufactured and validated with a colon phantom composed of tissue-mimicking oil-gelatin materials reproducing the anatomy and dielectric properties of a human colon with a polyp. The acquisition was performed by a miniaturized ring-shaped switched array of 16 antennas attachable at the tip of a conventional colonoscope. This has been conceived to satisfy endoscopy size restrictions, patient safety and intercompatibility with current clinical practice. A Modified Monofocusing imaging method preceded by a previous frame average subtraction as a calibration technique shows a perfect detection of a 10-mm polyp (100% sensitivity and specificity) in the eight analyzed trajectories. The phantom results demonstrate the feasibility of the system in future preclinical trials.
- 28 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 148048-148059
Open AccessAutomatic Polyp Detection Using Microwave Endoscopy for Colorectal Cancer Prevention and Early Detection: Phantom Validation
A system to integrate microwave imaging with optical colonoscopy is presented. The overarching goal is to improve the prevention and early diagnosis of one of the main health and economic burdens of an increasingly aging population, i.e., colorectal cancer. For a colonoscopy, the gold standard for colorectal cancer diagnosis, 22% of polyps are not detected, and the risk of cancer after a negative colonoscopy can be up to 7.9%. To remedy this, a microwave imaging system able to generate an alarm when a polyp is detected is designed, manufactured and validated with a colon phantom composed of tissue-mimicking oil-gelatin materials reproducing the anatomy and dielectric properties of a human colon with a polyp. The acquisition was performed by a miniaturized ring-shaped switched array of 16 antennas attachable at the tip of a conventional colonoscope. This has been conceived to satisfy endoscopy size restrictions, patient safety and intercompatibility with current clinical practice. A Modified Monofocusing imaging method preceded by a previous frame average subtraction as a calibration technique shows a perfect detection of a 10-mm polyp (100% sensitivity and specificity) in the eight analyzed trajectories. The phantom results demonstrate the feasibility of the system in future preclinical trials.