Jiuxuan Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jiuxuan Zhao has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Edoardo Charbon
École Polytechnique Fédérale de Lausanne
5 shared publications - Daniele Faccio
University of Glasgow
4 shared publications - Hugo Defienne
Sorbonne Université, CNRS, Institut des Nanosciences de Paris, Paris, France
3 shared publications - Ashley Lyons
School of Physics and Astronomy, University of Glasgow, Glasgow, UK
2 shared publications - Dongyang Chen
State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, China
2 shared publications - Elgin Quek
GLOBALFOUNDRIES Singapore Pte. Ltd., Singapore
2 shared publications
Latest Publications
- Open Access
Fluorescence-lifetime optical electrophysiology in contracting cardiomyocytes
Precise monitoring of cardiac electrophysiology in vitro is crucial to understanding heart function and cardiac disease. However, high-throughput, contact-free methods for directly measuring excitation-contraction coupling remain limited. Here, we introduce a new paradigm for quantitative electrophysiological imaging that combines fluorescence lifetime and intensity information to capture dynamic cardiac signals with high fidelity. We show that lifetime measurements are intrinsically decoupled from motion artifacts and provide calibrated calcium concentration and membrane potential readouts across wide fields of view. Using a gated single-photon avalanche diode camera, we acquire fluorescence lifetime images at up to 200 frames per second with sufficient signal-to-noise ratio such that each frame contains meaningful lifetime information without temporal averaging. This approach yields spatially resolved maps of absolute voltage and calcium values across contracting cardiomyocyte monolayers, revealing heterogeneous cell behaviors within individual assays and uncovering previously unreported dynamics during late-phase repolarization for real-time analysis of excitation-contraction coupling.
Open AccessFluorescence-lifetime optical electrophysiology in contracting cardiomyocytes
Precise monitoring of cardiac electrophysiology in vitro is crucial to understanding heart function and cardiac disease. However, high-throughput, contact-free methods for directly measuring excitation-contraction coupling remain limited. Here, we introduce a new paradigm for quantitative electrophysiological imaging that combines fluorescence lifetime and intensity information to capture dynamic cardiac signals with high fidelity. We show that lifetime measurements are intrinsically decoupled from motion artifacts and provide calibrated calcium concentration and membrane potential readouts across wide fields of view. Using a gated single-photon avalanche diode camera, we acquire fluorescence lifetime images at up to 200 frames per second with sufficient signal-to-noise ratio such that each frame contains meaningful lifetime information without temporal averaging. This approach yields spatially resolved maps of absolute voltage and calcium values across contracting cardiomyocyte monolayers, revealing heterogeneous cell behaviors within individual assays and uncovering previously unreported dynamics during late-phase repolarization for real-time analysis of excitation-contraction coupling.
- 5 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 30 (1: Single-) , 1-10
A Gradient-Gated SPAD Array for Non-Line-of-Sight Imaging
Time-resolved non-line-of-sight (NLOS) imaging based on single-photon avalanche diode (SPAD) detectors have demonstrated impressive results in recent years. To acquire adequate number of indirect photons from a hidden scene in the presence of overwhelming amount of early-arrival photons, a single-gated SPAD is widely employed to mitigate pile-up. However, additional prior knowledge of the hidden range and relay surface profile are required to preset the gating position and implement the reconstruction. With this work, we propose a gradient-gated technique to alleviate these shortcomings (pile-up and prior knowledge) in NLOS imaging with the development of a 6 × 6 SPAD array fabricated in a standard 55-nm Bipolar-CMOS-DMOS (BCD) technology. The SPAD sensor includes a delay-locked loop (DLL) block, a gating generator and a pixel array, which can be flexibly configured to free-running, single-gating and gradient-gating modes. The rise time of the gates is less than 450 ps (from 10% to 90%). In gradient-gating mode, the interval time between adjacent gates can be configured from 300 ps to 2 ns. In single-gating mode, the minimum gate window is measured below 5 ns. We demonstrated the sensor in a confocal NLOS imaging system that reconstructs hidden scenes with both retroreflective and diffuse objects. The presented scheme enables the development of calibration-free NLOS imaging modality for practical applications.
- 5 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 30 (1: Single-) , 1-10
A Gradient-Gated SPAD Array for Non-Line-of-Sight Imaging
Time-resolved non-line-of-sight (NLOS) imaging based on single-photon avalanche diode (SPAD) detectors have demonstrated impressive results in recent years. To acquire adequate number of indirect photons from a hidden scene in the presence of overwhelming amount of early-arrival photons, a single-gated SPAD is widely employed to mitigate pile-up. However, additional prior knowledge of the hidden range and relay surface profile are required to preset the gating position and implement the reconstruction. With this work, we propose a gradient-gated technique to alleviate these shortcomings (pile-up and prior knowledge) in NLOS imaging with the development of a 6 × 6 SPAD array fabricated in a standard 55-nm Bipolar-CMOS-DMOS (BCD) technology. The SPAD sensor includes a delay-locked loop (DLL) block, a gating generator and a pixel array, which can be flexibly configured to free-running, single-gating and gradient-gating modes. The rise time of the gates is less than 450 ps (from 10% to 90%). In gradient-gating mode, the interval time between adjacent gates can be configured from 300 ps to 2 ns. In single-gating mode, the minimum gate window is measured below 5 ns. We demonstrated the sensor in a confocal NLOS imaging system that reconstructs hidden scenes with both retroreflective and diffuse objects. The presented scheme enables the development of calibration-free NLOS imaging modality for practical applications.
- Open Access
- 22 June 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-9
Pixel super-resolution with spatially entangled photons
Pixelation occurs in many imaging systems and limits the spatial resolution of the acquired images. This effect is notably present in quantum imaging experiments with correlated photons in which the number of pixels used to detect coincidences is often limited by the sensor technology or the acquisition speed. Here, we introduce a pixel super-resolution technique based on measuring the full spatially-resolved joint probability distribution (JPD) of spatially-entangled photons. Without shifting optical elements or using prior information, our technique increases the pixel resolution of the imaging system by a factor two and enables retrieval of spatial information lost due to undersampling. We demonstrate its use in various quantum imaging protocols using photon pairs, including quantum illumination, entanglement-enabled quantum holography, and in a full-field version of N00N-state quantum holography. The JPD pixel super-resolution technique can benefit any full-field imaging system limited by the sensor spatial resolution, including all already established and future photon-correlation-based quantum imaging schemes, bringing these techniques closer to real-world applications.
- 22 June 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-9
Open AccessPixel super-resolution with spatially entangled photons
Pixelation occurs in many imaging systems and limits the spatial resolution of the acquired images. This effect is notably present in quantum imaging experiments with correlated photons in which the number of pixels used to detect coincidences is often limited by the sensor technology or the acquisition speed. Here, we introduce a pixel super-resolution technique based on measuring the full spatially-resolved joint probability distribution (JPD) of spatially-entangled photons. Without shifting optical elements or using prior information, our technique increases the pixel resolution of the imaging system by a factor two and enables retrieval of spatial information lost due to undersampling. We demonstrate its use in various quantum imaging protocols using photon pairs, including quantum illumination, entanglement-enabled quantum holography, and in a full-field version of N00N-state quantum holography. The JPD pixel super-resolution technique can benefit any full-field imaging system limited by the sensor spatial resolution, including all already established and future photon-correlation-based quantum imaging schemes, bringing these techniques closer to real-world applications.
- 22 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 28 (5: Lidars ) , 1-10
On Analog Silicon Photomultipliers in Standard 55-nm BCD Technology for LiDAR Applications
We present an analog silicon photomultiplier (SiPM) based on a standard 55-nm Bipolar-CMOS-DMOS (BCD) technology. The SiPM is composed of 16 × 16 single-photon avalanche diodes (SPADs) and measures 0.29 × 0.32 mm$^{2}$ . Each SPAD cell is passively quenched by a monolithically integrated 3.3 V thick oxide transistor. The measured gain is 3.4 × 10$^{5}$ at 5 V excess bias voltage. The single-photon timing resolution (SPTR) is 185 ps and the multi-photon timing resolution (MPTR) is 120 ps at 3.3 V excess bias voltage. We integrate the SiPM into a co-axial light detection and ranging (LiDAR) system with a time-correlated single-photon counting (TCSPC) module in FPGA. The depth measurement up to 25 m achieves an accuracy of 2 cm and precision of 2 mm under the room ambient light condition. With co-axial scanning, the intensity and depth images of complex scenes with resolutions of 128 × 256 and 256 × 512 are demonstrated. The presented SiPM enables the development of cost-effective LiDAR system-on-chip (SoC) in the advanced technology.- 22 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 28 (5: Lidars ) , 1-10
On Analog Silicon Photomultipliers in Standard 55-nm BCD Technology for LiDAR Applications
We present an analog silicon photomultiplier (SiPM) based on a standard 55-nm Bipolar-CMOS-DMOS (BCD) technology. The SiPM is composed of 16 × 16 single-photon avalanche diodes (SPADs) and measures 0.29 × 0.32 mm$^{2}$ . Each SPAD cell is passively quenched by a monolithically integrated 3.3 V thick oxide transistor. The measured gain is 3.4 × 10$^{5}$ at 5 V excess bias voltage. The single-photon timing resolution (SPTR) is 185 ps and the multi-photon timing resolution (MPTR) is 120 ps at 3.3 V excess bias voltage. We integrate the SiPM into a co-axial light detection and ranging (LiDAR) system with a time-correlated single-photon counting (TCSPC) module in FPGA. The depth measurement up to 25 m achieves an accuracy of 2 cm and precision of 2 mm under the room ambient light condition. With co-axial scanning, the intensity and depth images of complex scenes with resolutions of 128 × 256 and 256 × 512 are demonstrated. The presented SiPM enables the development of cost-effective LiDAR system-on-chip (SoC) in the advanced technology.- Open Access
- 20 January 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (3) , 3675-3683
Light detection and ranging with entangled photons
Single-photon light detection and ranging (LiDAR) is a key technology for depth imaging through complex environments. Despite recent advances, an open challenge is the ability to isolate the LiDAR signal from other spurious sources including background light and jamming signals. Here we show that a time-resolved coincidence scheme can address these challenges by exploiting spatio-temporal correlations between entangled photon pairs. We demonstrate that a photon-pair-based LiDAR can distill desired depth information in the presence of both synchronous and asynchronous spurious signals without prior knowledge of the scene and the target object. This result enables the development of robust and secure quantum LiDAR systems and paves the way to time-resolved quantum imaging applications.
- 20 January 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (3) , 3675-3683
Open AccessLight detection and ranging with entangled photons
Single-photon light detection and ranging (LiDAR) is a key technology for depth imaging through complex environments. Despite recent advances, an open challenge is the ability to isolate the LiDAR signal from other spurious sources including background light and jamming signals. Here we show that a time-resolved coincidence scheme can address these challenges by exploiting spatio-temporal correlations between entangled photon pairs. We demonstrate that a photon-pair-based LiDAR can distill desired depth information in the presence of both synchronous and asynchronous spurious signals without prior knowledge of the scene and the target object. This result enables the development of robust and secure quantum LiDAR systems and paves the way to time-resolved quantum imaging applications.
- 13 April 2021
- Published by American Physical Society (APS) in Physical Review A
- Vol. 103 (4) , 042608
Full-field quantum imaging with a single-photon avalanche diode camera
Single-photon avalanche diode (SPAD) arrays are essential tools in biophotonics, optical ranging and sensing, and quantum optics. However, their small number of pixels, low quantum efficiency, and small fill factor have so far hindered their use for practical imaging applications. Here, we demonstrate full-field entangled photon-pair correlation imaging using a 100-kpixel SPAD camera. By measuring photon coincidences between more than 500 million pairs of positions, we retrieve the full point spread function of the imaging system and subsequently high-resolution images of target objects illuminated by spatially entangled photon pairs. We show that our imaging approach is robust against stray light, enabling quantum imaging technologies to move beyond laboratory experiments towards real-world applications such as quantum light detection and ranging.
- 13 April 2021
- Published by American Physical Society (APS) in Physical Review A
- Vol. 103 (4) , 042608
Full-field quantum imaging with a single-photon avalanche diode camera
Single-photon avalanche diode (SPAD) arrays are essential tools in biophotonics, optical ranging and sensing, and quantum optics. However, their small number of pixels, low quantum efficiency, and small fill factor have so far hindered their use for practical imaging applications. Here, we demonstrate full-field entangled photon-pair correlation imaging using a 100-kpixel SPAD camera. By measuring photon coincidences between more than 500 million pairs of positions, we retrieve the full point spread function of the imaging system and subsequently high-resolution images of target objects illuminated by spatially entangled photon pairs. We show that our imaging approach is robust against stray light, enabling quantum imaging technologies to move beyond laboratory experiments towards real-world applications such as quantum light detection and ranging.
- 1 January 2018
- Published by AIP Publishing in Applied Physics Letters
- Vol. 112 (1)
Sensitivity manipulation on micro-machined resonant electrometer toward high resolution and large dynamic range
A micro-resonant electrometer with the scheme of sensitivity manipulation is proposed to realize the high resolution and large dynamic range based on a mechanical resonator and actuator. As the key sensing element, the double-ended tuning fork resonator has a quality factor close to 10 000 and low motional resistance below 0.5 MΩ. Electrical and mechanical nonlinear features of the resonator are investigated. The charge sensing functionality based on the axial strain modulation scheme is calibrated with a high resolution of 2.6 fC under 0.46 ppm frequency fluctuation. With the manipulation, the sensitivity is linearized from quadratic and further decreased to extend the dynamic range by 358.47% up to 12.38 pC. Meanwhile, the frequency fluctuation is also stabilized under 70 mHz to enhance the short-term stability of the sensor.
- 1 January 2018
- Published by AIP Publishing in Applied Physics Letters
- Vol. 112 (1)
Sensitivity manipulation on micro-machined resonant electrometer toward high resolution and large dynamic range
A micro-resonant electrometer with the scheme of sensitivity manipulation is proposed to realize the high resolution and large dynamic range based on a mechanical resonator and actuator. As the key sensing element, the double-ended tuning fork resonator has a quality factor close to 10 000 and low motional resistance below 0.5 MΩ. Electrical and mechanical nonlinear features of the resonator are investigated. The charge sensing functionality based on the axial strain modulation scheme is calibrated with a high resolution of 2.6 fC under 0.46 ppm frequency fluctuation. With the manipulation, the sensitivity is linearized from quadratic and further decreased to extend the dynamic range by 358.47% up to 12.38 pC. Meanwhile, the frequency fluctuation is also stabilized under 70 mHz to enhance the short-term stability of the sensor.
- Open Access
- 1 October 2016
- Published by AIP Publishing in AIP Advances
- Vol. 6 (10) , 105106
A micro resonant charge sensor with enhanced sensitivity based on differential sensing scheme and leverage mechanisms
This letter reports a micro-electro-mechanical systems (MEMS) resonant charge sensor with enhanced sensitivity based on differential sensing scheme and leverage mechanisms. The sensor comprises two symmetrically-distributed double-ended tuning fork (DETF) resonators, each of which connects with dual micro-leverage mechanisms. The micro-leverages amplify electrostatic force in opposite directions and cause differential frequency shift of the two resonators. Both the resonators show a similar trend in behaviors of electrical and mechanical nonlinearity. Effect of environment disturbance is suppressed by the differential sensing scheme. The measured sensitivity of the two resonators are 3.31×10-4 Hz/fC2 and 1.85×10-4 Hz/fC2 respectively, and an overall sensitivity for the resonant charge sensor is 5.16×10-4 Hz/fC2.
- 1 October 2016
- Published by AIP Publishing in AIP Advances
- Vol. 6 (10) , 105106
Open AccessA micro resonant charge sensor with enhanced sensitivity based on differential sensing scheme and leverage mechanisms
This letter reports a micro-electro-mechanical systems (MEMS) resonant charge sensor with enhanced sensitivity based on differential sensing scheme and leverage mechanisms. The sensor comprises two symmetrically-distributed double-ended tuning fork (DETF) resonators, each of which connects with dual micro-leverage mechanisms. The micro-leverages amplify electrostatic force in opposite directions and cause differential frequency shift of the two resonators. Both the resonators show a similar trend in behaviors of electrical and mechanical nonlinearity. Effect of environment disturbance is suppressed by the differential sensing scheme. The measured sensitivity of the two resonators are 3.31×10-4 Hz/fC2 and 1.85×10-4 Hz/fC2 respectively, and an overall sensitivity for the resonant charge sensor is 5.16×10-4 Hz/fC2.
- 8 June 2015
- Published by AIP Publishing in Applied Physics Letters
- Vol. 106 (23) , 233505
Electrostatic charge sensor based on a micromachined resonator with dual micro-levers
This paper describes an electrostatic charge sensor based on a microelectromechanical systems (MEMS) resonator with dual micro-levers to improve sensitivity. The device comprises a double-ended tuning fork resonant element working at out-of-phase mode with a quality factor (Q) of about 4900 under operating pressure of 40 mTorr. The resonant frequency shifts in proportion to an axial force induced by charge additions and then transformed by dual micro-levers with an amplification factor over 8. The measured responsivity is , which matches well with the results from analytical models and finite element method. The sensitivity of the charge sensor is 21 fC under 4 ppm frequency fluctuation. Additionally, electrostatic spring softening and nonlinear feature of the resonator are also investigated.- 8 June 2015
- Published by AIP Publishing in Applied Physics Letters
- Vol. 106 (23) , 233505
Electrostatic charge sensor based on a micromachined resonator with dual micro-levers
This paper describes an electrostatic charge sensor based on a microelectromechanical systems (MEMS) resonator with dual micro-levers to improve sensitivity. The device comprises a double-ended tuning fork resonant element working at out-of-phase mode with a quality factor (Q) of about 4900 under operating pressure of 40 mTorr. The resonant frequency shifts in proportion to an axial force induced by charge additions and then transformed by dual micro-levers with an amplification factor over 8. The measured responsivity is , which matches well with the results from analytical models and finite element method. The sensitivity of the charge sensor is 21 fC under 4 ppm frequency fluctuation. Additionally, electrostatic spring softening and nonlinear feature of the resonator are also investigated.