Razim Refai
Research Subjects
Research Interests
Razim Refai has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Dan K. Thompson
Natural Resources Canada, Canadian Forest Service, Great Lakes Forestry Centre, Sault Ste. Marie, Canada
2 shared publications - Dave Schroeder
Alberta Agriculture and Forestry, Wildfire Management Branch, Government of Alberta, Edmonton, AB T5K 1E4, Canada
2 shared publications - Ginny Marshall
Canadian Forest Service, Natural Resources Canada, Northern Forestry Centre, Edmonton, AB T6H 3S5, Canada
2 shared publications - Brett Moore
Canadian Forest Service, Natural Resources Canada, Northern Forestry Centre, Edmonton, AB T6H 3S5, Canada
1 shared publication - Christopher Rodell
The University of British Columbia, Vancouver, British Columbia, Canada
1 shared publication - Daniel A. Yip
Canadian Wildlife Service, Environment and Climate Change Canada Delta British Columbia Canada
1 shared publication
Latest Publications
- Open Access
- 2 February 2022
- Published by Springer Nature in Fire Technology
- Vol. 58 (3) , 1617-1638
Quantifying Firebrand Production and Transport Using the Acoustic Analysis of In-Fire Cameras
Firebrand travel and ignition of spot fires is a major concern in the Wildland-Urban Interface and in wildfire operations overall. Firebrands allow for the efficient breaching across fuel-free barriers such as roads, rivers and constructed fuel breaks. Existing observation-based knowledge on medium-distance firebrand travel is often based on single tree experiments that do not replicate the intensity and convective updraft of a continuous crown fire. Recent advances in acoustic analysis, specifically pattern detection, has enabled the quantification of the rate at which firebrands are observed in the audio recordings of in-fire cameras housed within fire-proof steel boxes that have been deployed on experimental fires. The audio pattern being detected is the sound created by a flying firebrand hitting the steel box of the camera. This technique allows for the number of firebrands per second to be quantified and can be related to the fire's location at that same time interval (using a detailed rate of spread reconstruction) in order to determine the firebrand travel distance. A proof of concept is given for an experimental crown fire that shows the viability of this technique. When related to the fire's location, key areas of medium-distance spotting are observed that correspond to regions of peak fire intensity. Trends on the number of firebrands landing per square metre as the fire approaches are readily quantified using low-cost instrumentation.
- 2 February 2022
- Published by Springer Nature in Fire Technology
- Vol. 58 (3) , 1617-1638
Open AccessQuantifying Firebrand Production and Transport Using the Acoustic Analysis of In-Fire Cameras
Firebrand travel and ignition of spot fires is a major concern in the Wildland-Urban Interface and in wildfire operations overall. Firebrands allow for the efficient breaching across fuel-free barriers such as roads, rivers and constructed fuel breaks. Existing observation-based knowledge on medium-distance firebrand travel is often based on single tree experiments that do not replicate the intensity and convective updraft of a continuous crown fire. Recent advances in acoustic analysis, specifically pattern detection, has enabled the quantification of the rate at which firebrands are observed in the audio recordings of in-fire cameras housed within fire-proof steel boxes that have been deployed on experimental fires. The audio pattern being detected is the sound created by a flying firebrand hitting the steel box of the camera. This technique allows for the number of firebrands per second to be quantified and can be related to the fire's location at that same time interval (using a detailed rate of spread reconstruction) in order to determine the firebrand travel distance. A proof of concept is given for an experimental crown fire that shows the viability of this technique. When related to the fire's location, key areas of medium-distance spotting are observed that correspond to regions of peak fire intensity. Trends on the number of firebrands landing per square metre as the fire approaches are readily quantified using low-cost instrumentation.
- Open Access
Recent Crown Thinning in a Boreal Black Spruce Forest Does Not Reduce Spread Rate nor Total Fuel Consumption: Results from an Experimental Crown Fire in Alberta, Canada
A 3.6 ha experimental fire was conducted in a black spruce peatland forest that had undergone thinning the year prior. After 50 m of spread in a natural stand at 35–60 m min−1, the crown fire (43,000 kW m−1 intensity using Byram’s method) encountered the 50% stem removal treatment; spread rates in the treatment were 50–60 m min−1. Fuel consumption in the control (2.75 kg m−2) was comparable to the treatment (2.35 kg m−2). Proxy measurements of fire intensity using in-stand heat flux sensors as well as photogrammetric flame heights had detected intensity reductions to 30–40% of the control. Crown fuel load reductions (compensated by higher surface fuel load) appear to be the most significant contributor to the decline in intensity, despite drier surface fuels in the treatment. The burn depth of 5 cm in moss and organic soil did not differ between control and treatment. These observations point to the limited effectiveness (likely reductions in crown fire intensity but not spread rate) of stem removal in boreal black spruce fuel types with high stem density, low crown base height and high surface fuel load. The observed fire behaviour impacts differ from drier conifer forests across North America.
Open AccessRecent Crown Thinning in a Boreal Black Spruce Forest Does Not Reduce Spread Rate nor Total Fuel Consumption: Results from an Experimental Crown Fire in Alberta, Canada
A 3.6 ha experimental fire was conducted in a black spruce peatland forest that had undergone thinning the year prior. After 50 m of spread in a natural stand at 35–60 m min−1, the crown fire (43,000 kW m−1 intensity using Byram’s method) encountered the 50% stem removal treatment; spread rates in the treatment were 50–60 m min−1. Fuel consumption in the control (2.75 kg m−2) was comparable to the treatment (2.35 kg m−2). Proxy measurements of fire intensity using in-stand heat flux sensors as well as photogrammetric flame heights had detected intensity reductions to 30–40% of the control. Crown fuel load reductions (compensated by higher surface fuel load) appear to be the most significant contributor to the decline in intensity, despite drier surface fuels in the treatment. The burn depth of 5 cm in moss and organic soil did not differ between control and treatment. These observations point to the limited effectiveness (likely reductions in crown fire intensity but not spread rate) of stem removal in boreal black spruce fuel types with high stem density, low crown base height and high surface fuel load. The observed fire behaviour impacts differ from drier conifer forests across North America.