WRWolfgang Recheis

Wolfgang Recheis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wolfgang Recheis has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Pre-surgery planning tool for estimation of resection volume to improve nasal breathing based on lattice Boltzmann fluid flow simulations

    by M. Berger, M. Pillei, A. Giotakis, A. Mehrle, W. Recheis, F. Kral, M. Kraxner, H. Riechelmann, W. Freysinger

    Purpose: State-of-the-art medical examination techniques (e.g., rhinomanometry and endoscopy) do not always lead to satisfactory postoperative outcome. A fully automatized optimization tool based on patient computer tomography (CT) data to calculate local pressure gradient regions to reshape pathological nasal cavity geometry is proposed. Methods: Five anonymous pre- and postoperative CT datasets with nasal septum deviations were used to simulate the airflow through the nasal cavity with lattice Boltzmann (LB) simulations. Pressure gradient regions were detected by a streamline analysis. After shape optimization, the volumetric difference between the two shapes of the nasal cavity yields the estimated resection volume. Results: At LB rhinomanometry boundary conditions (bilateral flow rate of 600 ml/s), the preliminary study shows a critical pressure gradient of −1.1 Pa/mm as optimization criterion. The maximum coronal airflow ΔA := cross-section ratio $$\frac{\mathrm{virtual surgery }}{\mathrm{post}-\mathrm{surgery}}$$ virtual surgery post - surgery found close to the nostrils is 1.15. For the patients a pressure drop ratio ΔΠ := (pre-surgery − virtual surgery)/(pre-surgery − post-surgery) between nostril and nasopharynx of 1.25, 1.72, −1.85, 0.79 and 1.02 is calculated. Conclusions: LB fluid mechanics optimization of the nasal cavity can yield results similar to surgery for air-flow cross section and pressure drop between nostril and nasopharynx. The optimization is numerically stable in all five cases of the presented study. A limitation of this study is that anatomical constraints (e.g. mucosa) have not been considered.


  • Open Access

    Agreement between rhinomanometry and computed tomography-based computational fluid dynamics

    by Manuel Berger, Aris I. Giotakis, Martin Pillei, Andreas Mehrle, Michael Kraxner, Florian Kral, Wolfgang Recheis, Herbert Riechelmann, Wolfgang Freysinger

    Purpose: Active anterior rhinomanometry (AAR) and computed tomography (CT) are standardized methods for the evaluation of nasal obstruction. Recent attempts to correlate AAR with CT-based computational fluid dynamics (CFD) have been controversial. We aimed to investigate this correlation and agreement based on an in-house developed procedure. Methods: In a pilot study, we retrospectively examined five subjects scheduled for septoplasty, along with preoperative digital volume tomography and AAR. The simulation was performed with Sailfish CFD, a lattice Boltzmann code. We examined the correlation and agreement of pressure derived from AAR (RhinoPress) and simulation (SimPress) and these of resistance during inspiration by 150 Pa pressure drop derived from AAR (RhinoRes150) and simulation (SimRes150). For investigation of correlation between pressures and between resistances, a univariate analysis of variance and a Pearson’s correlation were performed, respectively. For investigation of agreement, the Bland–Altman method was used. Results: The correlation coefficient between RhinoPress and SimPress was r = 0.93 (p < 0.001). RhinoPress was similar to SimPress in the less obstructed nasal side and two times greater than SimPress in the more obstructed nasal side. A moderate correlation was found between RhinoRes150 and SimRes150 (r = 0.65; p = 0.041). Conclusion: The simulation of rhinomanometry pressure by CT-based CFD seems more feasible with the lattice Boltzmann code in the less obstructed nasal side. In the more obstructed nasal side, error rates of up to 100% were encountered. Our results imply that the pressure and resistance derived from CT-based CFD and AAR were similar, yet not same.


  • Nasal cavity airflow: Comparing laser doppler anemometry and computational fluid dynamic simulations

    by M. Berger, M. Pillei, A. Mehrle, W. Recheis, F. Kral, M. Kraxner, Z. Bardosi, W. Freysinger


  • Open Access

    Late subadult ontogeny and adult aging of the human thorax reveals divergent growth trajectories between sexes

    by Daniel García-Martínez, Markus Bastir, Chiara Villa, Francisco García-Río, Isabel Torres-Sánchez, Wolfgang Recheis, Alon Barash, Roman Hossein Khonsari, Paul O’hIggins, Marc R. Meyer, et al.

    Sexual dimorphism is an important feature of adult thorax morphology, but when and how sex-related differences in the ribcage arise during ontogeny is poorly known. Previous research proposed that sex-related size differences in the nasal region arise during puberty. Therefore, we explore whether ribcage sexual dimorphism also arises at that time and whether this sexual dimorphism is maintained until old age. We measured 526 (semi)landmarks on 80 CT-based human ribcage reconstructions, on individuals ranging from 7 to 65 year-old. The 3D coordinates were submitted to the Procrustes superimposition and analyzed. Our results show that the trajectories of thorax size and shape between sexes diverge at around 12 years of age, and continue slightly diverging until old age. The differential ontogenetic trends cause adult male ribcages to become deeper, shorter, and wider than female. Our results are consistent with the evidence from the cranial respiratory system, with the development of sexual dimorphism probably related to changes in body composition during puberty combined with changes in the reproductive system.


  • Custom implant design for large cranial defects

    by Filipe M. M. Marreiros, Y. Heuzé, M. Verius, C. Unterhofer, W. Freysinger, W. Recheis

    Purpose The aim of this work was to introduce a computer-aided design (CAD) tool that enables the design of large skull defect (>100 \(\mathrm{cm}^2\)) implants. Functional and aesthetically correct custom implants are extremely important for patients with large cranial defects. For these cases, preoperative fabrication of implants is recommended to avoid problems of donor site morbidity, sufficiency of donor material and quality. Finally, crafting the correct shape is a non-trivial task increasingly complicated by defect size. Methods We present a CAD tool to design such implants for the neurocranium. A combination of geometric morphometrics and radial basis functions, namely thin-plate splines, allows semiautomatic implant generation. The method uses symmetry and the best fitting shape to estimate missing data directly within the radiologic volume data. In addition, this approach delivers correct implant fitting via a boundary fitting approach. Results This method generates a smooth implant surface, free of sharp edges that follows the main contours of the boundary, enabling accurate implant placement in the defect site intraoperatively. The present approach is evaluated and compared to existing methods. A mean error of 89.29 % (72.64–100 %) missing landmarks with an error less or equal to 1 mm was obtained. Conclusion In conclusion, the results show that our CAD tool can generate patient-specific implants with high accuracy.


  • Computing Topology Preservation of RBF Transformations for Landmark-Based Image Registration

    by Roberto Cavoretto, Alessandra De Rossi, Hanli Qiao, Bernhard Quatember, Wolfgang Recheis, Martin Mayr


  • Open Access

    Computing Topology Preservation of RBF Transformations for Landmark-Based Image Registration

    by R. Cavoretto, A. De Rossi, H. Qiao, B. Quatember, W. Recheis, M. Mayr

    In image registration, a proper transformation should be topology preserving. Especially for landmark-based image registration, if the displacement of one landmark is larger enough than those of neighbourhood landmarks, topology violation will be occurred. This paper aim to analyse the topology preservation of some Radial Basis Functions (RBFs) which are used to model deformations in image registration. Mat\'{e}rn functions are quite common in the statistic literature (see, e.g. \cite{Matern86,Stein99}). In this paper, we use them to solve the landmark-based image registration problem. We present the topology preservation properties of RBFs in one landmark and four landmarks model respectively. Numerical results of three kinds of Mat\'{e}rn transformations are compared with results of Gaussian, Wendland's, and Wu's functions.

  • Masterstudiengang MedTech - modernes und interdisziplinäres Studium zwischen Medizin und Technik

    by Wolfgang Recheis, Martin Mayr

    Seit September 2009 gibt es an der Fachhochschule Wiener Neustadt die Möglichkeit, den Masterstudiengang MedTech zu belegen. Im Herbst 2011 konnten die ersten Studenten ihr Master-Diplom in Empfang nehmen. Dazu hatten wir alle, Referenten, Administration, Studiengangsleitung und vor allem die Studenten, Anlass zu feiern. Ein idealer Zeitpunkt also, um den Studiengang nochmals kurz vorzustellen und wichtige Interessenvertreter, wie Firmen, Absolventen und Studenten, zu Wort kommen zu lassen.

  • Radial Basis Functions and Splines for Landmark-Based Registration of Medical Images

    by Giampietro Allasia, Roberto Cavoretto, Alessandra De Rossi, Bernhard Quatember, Wolfgang Recheis, Martin Mayr, Stefanos Demertzis, Theodore E. Simos, George Psihoyios, Ch. Tsitouras

    We propose the use of a class of spline functions, called Lobachevsky splines, for landmark‐based registration. We recall the analytic expressions of the Lobachevsky splines and some of their properties, reasoning in the context of probability theory. These functions have simple analytic expressions and compact support. Numerical tests appear to be promising.