José Vidal Herrera-Romero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
José Vidal Herrera-Romero has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Dario Colorado
Centro de Investigación en Recursos Energéticos y Sustentables , 27870 Universidad Veracruzana , Av. Universidad Km 7.5, Col. Santa Isabel, Coatzacoalcos CP 96535 , Veracruz , México
4 shared publications - Beatris Adriana Escobedo-Trujillo
Universidad Veracruzana
3 shared publications - Francisco Alejandro Alaffita-Hernández
Universidad Veracruzana
2 shared publications - Lizbeth Morales-Salas
Universidad Veracruzana, Facultad de Ingeniería
2 shared publications - César Ramírez-Dolores
Posgrado en Ingeniería, Instituto de Energías Renovables, Universidad Nacional Autónoma de México, Temixco, Mexico
1 shared publication D. López-Liévano
Facultad de Ciencias Químicas, Universidad Veracruzana, Coatzacoalcos, Mexico
1 shared publication
Latest Publications
- Open Access
- 14 October 2026
- Published by Springer Nature in Energy Efficiency
- Vol. 19 (7) , 77
Experimental study of a horizontal air–water heat exchanger (AWHE) operating in a shallow aquifer and hot-humid climate
- 14 October 2026
- Published by Springer Nature in Energy Efficiency
- Vol. 19 (7) , 77
Open AccessExperimental study of a horizontal air–water heat exchanger (AWHE) operating in a shallow aquifer and hot-humid climate
- Open Access
- 30 August 2025
- Published by ECORFAN in Revista de Ingeniería Mecánica
Polynomial regression model for the prediction of thermal efficiency in spark ignition engines operating with ethanol-water mixtures
- 30 August 2025
- Published by ECORFAN in Revista de Ingeniería Mecánica
Open AccessPolynomial regression model for the prediction of thermal efficiency in spark ignition engines operating with ethanol-water mixtures
- 30 June 2024
- Published by ECORFAN in Revista de Ingenieria Innovativa
- p. 1-6
Prototype of a structure with variations in the angle of inclination for photovoltaic panels
One of the most critical parameters for the capture of solar radiation is the angle of inclination of the surface and its contribution to optimization to maximize the amount of solar irradiation received. Numerous methods have been used worldwide to determine the angle of inclination. Unfortunately, many of these models are for fixed angles, which do not adapt to the sun's position during the year, resulting in the loss of essential amounts of irradiation that could be used. This work presents the methodology for developing a structure for photovoltaic (PV) panels fixed to the floor, which includes variations in the angle of inclination. The goal is to maximize the solar energy gain (energy per square meter) the panel receives over a year by making monthly tilt angle adjustments. The inclination angles are calculated for a structure, which will be placed in Coatzacoalcos, Veracruz, Mexico. The monthly angle of the prototype can have positive and negative values (tropical region); the maximum is 41.19° for December, and the minimum is - 4.95°, corresponding to June. The study can be applied to build a similar structure, with related variations in the angle of inclination, to work in any city, as long as information from the city in question is
- 30 June 2024
- Published by ECORFAN in Revista de Ingenieria Innovativa
- p. 1-6
Prototype of a structure with variations in the angle of inclination for photovoltaic panels
One of the most critical parameters for the capture of solar radiation is the angle of inclination of the surface and its contribution to optimization to maximize the amount of solar irradiation received. Numerous methods have been used worldwide to determine the angle of inclination. Unfortunately, many of these models are for fixed angles, which do not adapt to the sun's position during the year, resulting in the loss of essential amounts of irradiation that could be used. This work presents the methodology for developing a structure for photovoltaic (PV) panels fixed to the floor, which includes variations in the angle of inclination. The goal is to maximize the solar energy gain (energy per square meter) the panel receives over a year by making monthly tilt angle adjustments. The inclination angles are calculated for a structure, which will be placed in Coatzacoalcos, Veracruz, Mexico. The monthly angle of the prototype can have positive and negative values (tropical region); the maximum is 41.19° for December, and the minimum is - 4.95°, corresponding to June. The study can be applied to build a similar structure, with related variations in the angle of inclination, to work in any city, as long as information from the city in question is
- Open Access
- 1 September 2023
- Published by Elsevier in Results in Control and Optimization
- Vol. 12
Constrained stochastic differential games with Markovian switchings and additive structure: The total expected payoff
- 1 September 2023
- Published by Elsevier in Results in Control and Optimization
- Vol. 12
Open AccessConstrained stochastic differential games with Markovian switchings and additive structure: The total expected payoff
- 28 April 2023
- Published by Springer Nature
- p. 139-157
Evaluation of the Solar Organic Rankine Cycle with Different Working Fluids
- 28 April 2023
- Published by Springer Nature
- p. 139-157
Evaluation of the Solar Organic Rankine Cycle with Different Working Fluids
- 31 December 2020
- Published by ECORFAN in Revista del Desarrollo Tecnologico
- p. 7-14
Exergy analysis of the absorption refrigeration cycle using economizers
This paper presents the study of a simple effect absorption refrigeration system (SRA) using the ammonia-water working couple, with the incorporation of three economizers and their analysis of the first and second law of thermodynamics, emphasizing the effect of the operating temperatures and the efficiency of the exchangers on the refrigerant circulation ratio (RC), the coefficient of performance (COP) of the system and the destruction of exergy. In order to determine the thermodynamic properties at each point of the system and evaluate the performance of the SRA, was programmed a tool in MATLAB with the governing equations. The results show that: the exergy efficiency increases when the temperature in the evaporator decreases; and RC decreases with increasing temperature in the generator. As conclusion, an increase in the effectiveness of heat exchangers cannot only decrease the refrigerant circulation rate, but also increase the inlet temperature of the solution to the generator, so that the temperature difference between the solution and the heat source decreases, causing a decrease in the rate of exergy destruction in the generator and the increase in COP.
- 31 December 2020
- Published by ECORFAN in Revista del Desarrollo Tecnologico
- p. 7-14
Exergy analysis of the absorption refrigeration cycle using economizers
This paper presents the study of a simple effect absorption refrigeration system (SRA) using the ammonia-water working couple, with the incorporation of three economizers and their analysis of the first and second law of thermodynamics, emphasizing the effect of the operating temperatures and the efficiency of the exchangers on the refrigerant circulation ratio (RC), the coefficient of performance (COP) of the system and the destruction of exergy. In order to determine the thermodynamic properties at each point of the system and evaluate the performance of the SRA, was programmed a tool in MATLAB with the governing equations. The results show that: the exergy efficiency increases when the temperature in the evaporator decreases; and RC decreases with increasing temperature in the generator. As conclusion, an increase in the effectiveness of heat exchangers cannot only decrease the refrigerant circulation rate, but also increase the inlet temperature of the solution to the generator, so that the temperature difference between the solution and the heat source decreases, causing a decrease in the rate of exergy destruction in the generator and the increase in COP.
- Open Access
Comparative Study of a Compression–Absorption Cascade System Operating with NH3-LiNO3, NH3-NaSCN, NH3-H2O, and R134a as Working Fluids
This research presents a comprehensive bibliographic review from 2006 through 2020 about the state of the art of the compression–absorption cascade systems for refrigeration. In consequence of this review, this research identifies the significant development of systems that consider lithium bromide as a working fluid; however, the use of other working fluids has not been developed. This study is motivated toward the development of a parametric analysis of the cascade system using NH3-LiNO3, NH3-NaSCN and NH3-H2O in the absorption cycle and R134a in the compression cycle. In this study, the effect of the heat source temperature, condensation temperature in the compression cycle, the use of heat exchangers in the system (also known as economizers) and their contribution to the coefficient of performance is deepened numerically. The economizers evaluated are the following: an internal heat exchanger, a refrigerant heat exchanger, a solution refrigerant heat exchanger, and a solution heat exchanger. Mass and energy balance equations—appropriate equations to estimate the thermophysical properties of several refrigerant–absorbent pairs—were used to develop a thermodynamic model. The studied heat source temperature range was from 355 to 380 K, and the studied condensation temperature range in the compression cycle was from 281 to –291 K; additionally, the importance of each economizer on the coefficient of performance was numerically estimated. In this way, NH3-NaSCN solution in the absorption cycle and R134a in the compression cycle provided promising numerical results with the highest COPs (coefficient of performance).
Open AccessComparative Study of a Compression–Absorption Cascade System Operating with NH3-LiNO3, NH3-NaSCN, NH3-H2O, and R134a as Working Fluids
This research presents a comprehensive bibliographic review from 2006 through 2020 about the state of the art of the compression–absorption cascade systems for refrigeration. In consequence of this review, this research identifies the significant development of systems that consider lithium bromide as a working fluid; however, the use of other working fluids has not been developed. This study is motivated toward the development of a parametric analysis of the cascade system using NH3-LiNO3, NH3-NaSCN and NH3-H2O in the absorption cycle and R134a in the compression cycle. In this study, the effect of the heat source temperature, condensation temperature in the compression cycle, the use of heat exchangers in the system (also known as economizers) and their contribution to the coefficient of performance is deepened numerically. The economizers evaluated are the following: an internal heat exchanger, a refrigerant heat exchanger, a solution refrigerant heat exchanger, and a solution heat exchanger. Mass and energy balance equations—appropriate equations to estimate the thermophysical properties of several refrigerant–absorbent pairs—were used to develop a thermodynamic model. The studied heat source temperature range was from 355 to 380 K, and the studied condensation temperature range in the compression cycle was from 281 to –291 K; additionally, the importance of each economizer on the coefficient of performance was numerically estimated. In this way, NH3-NaSCN solution in the absorption cycle and R134a in the compression cycle provided promising numerical results with the highest COPs (coefficient of performance).