RMRobert Marcovich

Robert Marcovich

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Robert Marcovich has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Thulium Fiber Laser–Assisted Endoureterotomy for Treatment of Complete Obliterative Uretero‐Ileal Conduit Anastomotic Stricture in a Patient With Ureteral Duplication: A Case Report

    by Ryan R. Chen, Aravindh Rathinam, Jonathan Katz, Robert Marcovich, Hemendra N. Shah

    One of the known complications of radical cystectomy with urinary diversion is the development of a benign ureteroenteric anastomotic stricture (UES), which can lead to hydronephrosis and renal dysfunction. Holmium:YAG lasers are commonly used for endoscopic management of these UES. Recently, thulium fiber lasers (TFLs) have shown promise in managing benign ureteral strictures due to their superior ablation qualities. We present the first reported case of successful TFL‐assisted endoureterotomy for a UES in a patient with a complete left ureteral duplication following RARC and ileal conduit urinary diversion. The patient developed symptomatic left lower moiety hydronephrosis, which was managed with antegrade ureteroscopy and TFL incision and ablation of a complete, obliterative, short segment stricture. An endoureterotomy stent was placed, and she had resolution of both symptoms and hydronephrosis. This case highlights TFL as a viable minimally invasive option for managing complex UES, including patients with anatomical variants such as ureteral duplication.

  • Open Access

    Survey of Microsurgery Training Availability in US Urology Residency Programs

    by Thomas A. Masterson, Sirpi Nackeeran, Quinn Rainer, Nicholas Hauser, Robert Marcovich, Ranjith Ramasamy

    Masterson TA, et al. World J Mens Health. 2020 Jan;38:e36. https://doi.org/10.5534/wjmh.190162


  • Effect of Endo-GIA vascular staple size on laparoscopic vessel sealing in a porcine model

    by A. El-Hakim, Y. Cai, R. Marcovich, P. Pinto, B. R. Lee

    Two sizes of endoscopic gastrointestinal anastomosis (Endo-GIA) staples are currently available for vascular control. The purpose of this study was to compare the Endo-GIA 30–2.0 mm with the Endo-GIA 30–2.5 mm vascular staple. The renal blood vessels, aorta, and vena cava were divided laparoscopically using the Endo-GIA 30–2.0 and 30–2.5 mm in four pigs, respectively. The arterial and venous segments were harvested en bloc for ex vivo burst pressure studies. Both 2.0-mm and 2.5-mm staples achieved vessel sealing at supraphysiologic mean burst pressures (≥310 mmHg). There were no statistical differences between mean burst pressures of vessels stapled by 2.0-mm compared to 2.5-mm staples. Both staples sealed arteries up to 17 mm and veins up to 22 mm in diameter. Endo-GIA 30–2.0 mm and 30–2.5 mm vascular staples are equivalent in sealing vessels at supraphysiologic mean burst pressures.


  • Immune Response to Laparoscopic Bowel Injury

    by Joel Patrick A. Aldana, Robert Marcovich, Pravin Singhal, Krishna Reddy, Nora Morgenstern, Assaad El-Hakim, Arthur D. Smith, Benjamin R. Lee

    Background and Purpose: Laparoscopic bowel injuries are rare but potentially fatal if recognition is delayed. Unlike the situation after open surgery, patients with unrecognized bowel injury after laparoscopy do not present with the typical "acute surgical abdomen." We investigated monocyte, neutrophil, and lymphocyte apoptosis as indicators of the immune response and whether this response is stimulated or suppressed by laparoscopic bowel injury compared with bowel injury induced during open surgery. Materials and Methods: After an animal protocol was approved, laparoscopy was performed in a rabbit model. A total of 44 animals were divided into four groups of 11 rabbits each. Laparoscopic bowel injury was created using 30-W electrocautery at 0 (control), 1, and 5 hours after induction of pneumoperitoneum. Bowel injury was created in the fourth group during open laparotomy. Animals were euthanized at 0, 1 day, 1 week, or 2 weeks after surgery. Apoptosis was assessed by staining the nuclei of blood cells with H-33342 dye. Results: At 1 week, neutrophil, monocyte, and lymphocyte apoptosis levels were 2.4- to 5-fold lower after laparoscopy (1-hour pneumoperitoneum) compared with open surgery. However, at 2 weeks, the percentage of apoptosis had equalized in the two groups. Interestingly, with longer laparoscopic procedures (5 hours), the percentage of apoptosis at 0 and 1 day more closely approached that seen after open surgery. At 2 weeks, there was a significant difference in apoptosis levels in all cell types between the experimental groups compared with controls (P < 0.001). No animals undergoing a 5-hour open procedure survived to 2 weeks after bowel injury. Conclusions: Open surgery resulted in a significant increase in programmed cell death compared with controls in the immediate postoperative period following bowel injury. Laparoscopic surgery produced a delayed response and after 2 weeks with bowel perforation approached open surgery levels. The difference in the degree of cellular death may be secondary to a smaller degree of stimulation of the immune response in laparoscopic surgery.