Michael Xiangjiang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael Xiangjiang Wang has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- David Yu Zhang
Biostate Ai, Inc
8 shared publications - Lauren B. Stadler
Department of Civil and Environmental Engineering, Rice University, 6100 Main Street, Houston, Texas 77005, United States
6 shared publications - Bryce Kille
Department of Computer Science, Rice University, Houston, TX, USA
4 shared publications - Peng Dai
College of Chemistry and Molecular Engineering, Peking University, Beijing, China
4 shared publications - Todd J. Treangen
Rice University
4 shared publications Jinny Zhang
NuProbe USA Inc
3 shared publications
Latest Publications
- Open Access
- 1 July 2026
- Published by Oxford University Press (OUP) in Bioinformatics
- Vol. 42 (Supplement)
Seqwin: ultrafast identification of signature sequences in microbial genomes.
Polymerase chain reaction (PCR) enables rapid, cost-effective diagnostics but requires prior identification of genomic regions that allow sensitive and specific detection of target microbial groups, herein referred to as microbial signature sequences. We introduce Seqwin, an open-source framework designed to automate microbial genome signature discovery. Tens of thousands of microbial genomes are now available for a single species, limiting the application of existing manual and automated approaches for identifying signatures. Modern approaches that are capable of leveraging all available microbial genomes will ensure sensitive and accurate DNA signature identification and enable robust pathogen detection for clinical, environmental, and public health applications. Seqwin builds weighted pan-genome minimizer graphs and uses a traversal algorithm to identify signature sequences that occur frequently in target genomes but remain rare in non-targets. Unlike earlier tools that depend on strict presence or absence of sequences, Seqwin accommodates natural sequence variation and scales to very large genome collections. When applied to genomes from C. difficile, M. tuberculosis, and S. enterica, Seqwin recovered more high-quality signatures than alternative methods with lower computational burden. Seqwin's analysis of nearly 15 000 S. enterica genomes yielded over 200 candidate signatures in three minutes. Seqwin provides an open-source solution for the long-standing need for scalable microbial signature discovery and diagnostic assay design. Seqwin is available on GitHub (https://github.com/treangenlab/Seqwin) and can be installed via Bioconda (https://bioconda.github.io/recipes/seqwin/README.html). Benchmarking datasets, outputs, and scripts are available on Zenodo (https://doi.org/10.5281/zenodo.19874011).
- 1 July 2026
- Published by Oxford University Press (OUP) in Bioinformatics
- Vol. 42 (Supplement)
Open AccessSeqwin: ultrafast identification of signature sequences in microbial genomes.
Polymerase chain reaction (PCR) enables rapid, cost-effective diagnostics but requires prior identification of genomic regions that allow sensitive and specific detection of target microbial groups, herein referred to as microbial signature sequences. We introduce Seqwin, an open-source framework designed to automate microbial genome signature discovery. Tens of thousands of microbial genomes are now available for a single species, limiting the application of existing manual and automated approaches for identifying signatures. Modern approaches that are capable of leveraging all available microbial genomes will ensure sensitive and accurate DNA signature identification and enable robust pathogen detection for clinical, environmental, and public health applications. Seqwin builds weighted pan-genome minimizer graphs and uses a traversal algorithm to identify signature sequences that occur frequently in target genomes but remain rare in non-targets. Unlike earlier tools that depend on strict presence or absence of sequences, Seqwin accommodates natural sequence variation and scales to very large genome collections. When applied to genomes from C. difficile, M. tuberculosis, and S. enterica, Seqwin recovered more high-quality signatures than alternative methods with lower computational burden. Seqwin's analysis of nearly 15 000 S. enterica genomes yielded over 200 candidate signatures in three minutes. Seqwin provides an open-source solution for the long-standing need for scalable microbial signature discovery and diagnostic assay design. Seqwin is available on GitHub (https://github.com/treangenlab/Seqwin) and can be installed via Bioconda (https://bioconda.github.io/recipes/seqwin/README.html). Benchmarking datasets, outputs, and scripts are available on Zenodo (https://doi.org/10.5281/zenodo.19874011).
- Open Access
Tracking Candida auris in Communities via Wastewater: Facility-Level Surveillance and Targeted Sequencing
Candida auris is a multidrug-resistant fungal pathogen that presents substantial challenges for healthcare facilities due to its high mortality rates among vulnerable populations. Six C. auris clades have been identified based on their susceptibility to antifungal treatment and environmental stressors. Identifying the circulating C. auris clade(s) is critical for understanding transmission and selecting a disease control strategy. To inform targeted implementation of community wastewater monitoring for C. auris , samples were collected over 34 weeks from 8 nursing homes and 6 downstream wastewater treatment plants (WWTPs). Detection rates and concentrations of C. auris DNA were significantly higher in samples from nursing homes compared to those from WWTPs. Amplicon sequencing methods were developed and applied to characterize the circulating C. auris clade in a nursing home wastewater sample. This study demonstrates the utility of wastewater monitoring as a resource-efficient approach for detecting and subtyping C. auris in vulnerable communities.
Open AccessTracking Candida auris in Communities via Wastewater: Facility-Level Surveillance and Targeted Sequencing
Candida auris is a multidrug-resistant fungal pathogen that presents substantial challenges for healthcare facilities due to its high mortality rates among vulnerable populations. Six C. auris clades have been identified based on their susceptibility to antifungal treatment and environmental stressors. Identifying the circulating C. auris clade(s) is critical for understanding transmission and selecting a disease control strategy. To inform targeted implementation of community wastewater monitoring for C. auris , samples were collected over 34 weeks from 8 nursing homes and 6 downstream wastewater treatment plants (WWTPs). Detection rates and concentrations of C. auris DNA were significantly higher in samples from nursing homes compared to those from WWTPs. Amplicon sequencing methods were developed and applied to characterize the circulating C. auris clade in a nursing home wastewater sample. This study demonstrates the utility of wastewater monitoring as a resource-efficient approach for detecting and subtyping C. auris in vulnerable communities.
- Open Access
Seqwin: Ultrafast identification of signature sequences in microbial genomes
Motivation: Polymerase chain reaction (PCR) enables rapid, cost-effective diagnostics but requires prior identification of genomic regions that allow sensitive and specific detection of target microbial groups, herein referred to as microbial signature sequences. We introduce Seqwin, an open-source framework designed to automate microbial genome signature discovery. Tens of thousands of microbial genomes are now available for a single species, limiting the application of existing manual and automated approaches for identifying signatures. Modern approaches that are capable of leveraging all available microbial genomes will ensure sensitive and accurate DNA signature identification and enable robust pathogen detection for clinical, environmental, and public health applications. Results: Seqwin builds weighted pan-genome minimizer graphs and uses a traversal algorithm to identify signature sequences that occur frequently in target genomes but remain rare in non-targets. Unlike earlier tools that depend on strict presence or absence of sequences, Seqwin accommodates natural sequence variation and scales to very large genome collections. When applied to genomes from C. difficile, M. tuberculosis, and S. enterica, Seqwin recovered more high-quality signatures than alternative methods with lower computational burden. Seqwin’s analysis of nearly 15,000 S. enterica genomes yielded over 200 candidate signatures in 5 minutes. Seqwin provides an open-source solution for the long-standing need for scalable microbial signature discovery and diagnostic assay design. Availability and Implementation: Seqwin is freely available for academic use ( https://github.com/treangenlab/Seqwin ) and can be installed via Bioconda. Benchmarking datasets, outputs, and scripts are available on Zenodo https://doi.org/10.5281/zenodo.19176444 . Contact: treangen@rice.edu , xw66@rice.edu Supplementary Materials: Provided as separate PDF and data files.
Open AccessSeqwin: Ultrafast identification of signature sequences in microbial genomes
Motivation: Polymerase chain reaction (PCR) enables rapid, cost-effective diagnostics but requires prior identification of genomic regions that allow sensitive and specific detection of target microbial groups, herein referred to as microbial signature sequences. We introduce Seqwin, an open-source framework designed to automate microbial genome signature discovery. Tens of thousands of microbial genomes are now available for a single species, limiting the application of existing manual and automated approaches for identifying signatures. Modern approaches that are capable of leveraging all available microbial genomes will ensure sensitive and accurate DNA signature identification and enable robust pathogen detection for clinical, environmental, and public health applications. Results: Seqwin builds weighted pan-genome minimizer graphs and uses a traversal algorithm to identify signature sequences that occur frequently in target genomes but remain rare in non-targets. Unlike earlier tools that depend on strict presence or absence of sequences, Seqwin accommodates natural sequence variation and scales to very large genome collections. When applied to genomes from C. difficile, M. tuberculosis, and S. enterica, Seqwin recovered more high-quality signatures than alternative methods with lower computational burden. Seqwin’s analysis of nearly 15,000 S. enterica genomes yielded over 200 candidate signatures in 5 minutes. Seqwin provides an open-source solution for the long-standing need for scalable microbial signature discovery and diagnostic assay design. Availability and Implementation: Seqwin is freely available for academic use ( https://github.com/treangenlab/Seqwin ) and can be installed via Bioconda. Benchmarking datasets, outputs, and scripts are available on Zenodo https://doi.org/10.5281/zenodo.19176444 . Contact: treangen@rice.edu , xw66@rice.edu Supplementary Materials: Provided as separate PDF and data files.
- Open Access
Sensitivity, throughput, and cost analysis of concentration methods for multi-target pathogen wastewater monitoring
Wastewater-based epidemiology is an efficient method for monitoring the transmission of diverse pathogens in communities. Standard wastewater surveillance workflows typically involve wastewater concentration, nucleic acid extraction, and pathogen quantification. While various concentration methods are used, most comparisons of concentration methods have focused primarily on SARS-CoV-2, highlighting the need for further research to guide method selection for monitoring a suite of diverse pathogens. In this study, a head-to-head comparison of six different concentration methods was performed, including direct extraction (with and without bead beating), electronegative (HA) filtration, solids concentration, and magnetic bead-based concentration (using Nanotrap® particles; with and without bead beating). Methods were assessed for sensitivity, inhibitor removal, and recovery rates of fourteen microorganisms, including viruses, bacteria, and fungal pathogens. The cost of each method was also estimated. Results showed that the concentration method selection significantly impacts the sensitivity and economic costs of the wastewater monitoring workflow. Based on the results, a concentration approach that combines HA filtration and solids concentration is recommended to optimize detection across various pathogens. This study provides data-driven insights to enhance the reliability and cost-effectiveness of wastewater surveillance systems that can support public health responses for a broad range of diseases. Synopsis Six concentration methods were compared in terms of sensitivity and cost for the detection of 14 diverse pathogens in wastewater.
Open AccessSensitivity, throughput, and cost analysis of concentration methods for multi-target pathogen wastewater monitoring
Wastewater-based epidemiology is an efficient method for monitoring the transmission of diverse pathogens in communities. Standard wastewater surveillance workflows typically involve wastewater concentration, nucleic acid extraction, and pathogen quantification. While various concentration methods are used, most comparisons of concentration methods have focused primarily on SARS-CoV-2, highlighting the need for further research to guide method selection for monitoring a suite of diverse pathogens. In this study, a head-to-head comparison of six different concentration methods was performed, including direct extraction (with and without bead beating), electronegative (HA) filtration, solids concentration, and magnetic bead-based concentration (using Nanotrap® particles; with and without bead beating). Methods were assessed for sensitivity, inhibitor removal, and recovery rates of fourteen microorganisms, including viruses, bacteria, and fungal pathogens. The cost of each method was also estimated. Results showed that the concentration method selection significantly impacts the sensitivity and economic costs of the wastewater monitoring workflow. Based on the results, a concentration approach that combines HA filtration and solids concentration is recommended to optimize detection across various pathogens. This study provides data-driven insights to enhance the reliability and cost-effectiveness of wastewater surveillance systems that can support public health responses for a broad range of diseases. Synopsis Six concentration methods were compared in terms of sensitivity and cost for the detection of 14 diverse pathogens in wastewater.
- Open Access
- 26 July 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-12
Olivar: towards automated variant aware primer design for multiplex tiled amplicon sequencing of pathogens
Tiled amplicon sequencing has served as an essential tool for tracking the spread and evolution of pathogens. Over 15 million complete SARS-CoV-2 genomes are now publicly available, most sequenced and assembled via tiled amplicon sequencing. While computational tools for tiled amplicon design exist, they require downstream manual optimization both computationally and experimentally, which is slow and costly. Here we present Olivar, a first step towards a fully automated, variant-aware design of tiled amplicons for pathogen genomes. Olivar converts each nucleotide of the target genome into a numeric risk score, capturing undesired sequence features that should be avoided. In a direct comparison with PrimalScheme, we show that Olivar has fewer mismatches overlapping with primers and predicted PCR byproducts. We also compare Olivar head-to-head with ARTIC v4.1, the most widely used primer set for SARS-CoV-2 sequencing, and show Olivar yields similar read mapping rates (~90%) and better coverage to the manually designed ARTIC v4.1 amplicons. We also evaluate Olivar on real wastewater samples and found that Olivar has up to 3-fold higher mapping rates while retaining similar coverage. In summary, Olivar automates and accelerates the generation of tiled amplicons, even in situations of high mutation frequency and/or density. Olivar is available online as a web application at https://olivar.rice.edu and can be installed locally as a command line tool with Bioconda. Source code, installation guide, and usage are available at https://github.com/treangenlab/Olivar.
- 26 July 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-12
Open AccessOlivar: towards automated variant aware primer design for multiplex tiled amplicon sequencing of pathogens
Tiled amplicon sequencing has served as an essential tool for tracking the spread and evolution of pathogens. Over 15 million complete SARS-CoV-2 genomes are now publicly available, most sequenced and assembled via tiled amplicon sequencing. While computational tools for tiled amplicon design exist, they require downstream manual optimization both computationally and experimentally, which is slow and costly. Here we present Olivar, a first step towards a fully automated, variant-aware design of tiled amplicons for pathogen genomes. Olivar converts each nucleotide of the target genome into a numeric risk score, capturing undesired sequence features that should be avoided. In a direct comparison with PrimalScheme, we show that Olivar has fewer mismatches overlapping with primers and predicted PCR byproducts. We also compare Olivar head-to-head with ARTIC v4.1, the most widely used primer set for SARS-CoV-2 sequencing, and show Olivar yields similar read mapping rates (~90%) and better coverage to the manually designed ARTIC v4.1 amplicons. We also evaluate Olivar on real wastewater samples and found that Olivar has up to 3-fold higher mapping rates while retaining similar coverage. In summary, Olivar automates and accelerates the generation of tiled amplicons, even in situations of high mutation frequency and/or density. Olivar is available online as a web application at https://olivar.rice.edu and can be installed locally as a command line tool with Bioconda. Source code, installation guide, and usage are available at https://github.com/treangenlab/Olivar.
- Open Access
- 3 April 2023
- Published by American Association for Cancer Research (AACR)
Supplementary Table 1 from In Vitro and In Vivo Therapeutic Efficacy of Carfilzomib in Mantle Cell Lymphoma: Targeting the Immunoproteasome
Eight MCL Cell lines were cultured for 48 hours in the presence of different concentrations of CFZ. Cell growth was assessed by 3H-thymidine incorporation assay. The IC50 were determined by constructing a dose-response curve. Averages from 3 independent experiments are shown.
- 3 April 2023
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Table 1 from In Vitro and In Vivo Therapeutic Efficacy of Carfilzomib in Mantle Cell Lymphoma: Targeting the Immunoproteasome
Eight MCL Cell lines were cultured for 48 hours in the presence of different concentrations of CFZ. Cell growth was assessed by 3H-thymidine incorporation assay. The IC50 were determined by constructing a dose-response curve. Averages from 3 independent experiments are shown.
- Open Access
- 3 April 2023
- Published by American Association for Cancer Research (AACR)
Supplementary Figure 1 from In Vitro and In Vivo Therapeutic Efficacy of Carfilzomib in Mantle Cell Lymphoma: Targeting the Immunoproteasome
PDF - 1267KB, The established MCL cell lines, JVM-2, JVM-13, MAVER, NCEB-1, and Z-138 were treated with 20 nM CFZ for 0, 6, 12, or 24 hours and apoptosis was detected by Annexin V-binding assays. Representative histograms (left panel) and percentages of apoptotic cells (right panel) are shown.
- 3 April 2023
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Figure 1 from In Vitro and In Vivo Therapeutic Efficacy of Carfilzomib in Mantle Cell Lymphoma: Targeting the Immunoproteasome
PDF - 1267KB, The established MCL cell lines, JVM-2, JVM-13, MAVER, NCEB-1, and Z-138 were treated with 20 nM CFZ for 0, 6, 12, or 24 hours and apoptosis was detected by Annexin V-binding assays. Representative histograms (left panel) and percentages of apoptotic cells (right panel) are shown.
- Open Access
Olivar: automated variant aware primer design for multiplex tiled amplicon sequencing of pathogens
Tiled amplicon sequencing has served as an essential tool for tracking the spread and evolution of pathogens. Over 2 million complete SARS-CoV-2 genomes are now publicly available, most sequenced and assembled via tiled amplicon sequencing. While computational tools for tiled amplicon design exist, they require downstream manual optimization both computationally and experimentally, which is slow and costly. Here we present Olivar, a first step towards a fully automated, variant-aware design of tiled amplicons for pathogen genomes. Olivar converts each nucleotide of the target genome into a numeric risk score, capturing undesired sequence features that should be avoided. In a direct comparison with PrimalScheme, we show that Olivar has fewer SNPs overlapping with primers and predicted PCR byproducts. We also compared Olivar head-to-head with ARTIC v4.1, the most widely used primer set for SARS-CoV-2 sequencing, and show Olivar yields similar read mapping rates (∼90%) and better coverage to the manually designed ARTIC v4.1 amplicons. We also evaluated Olivar on real wastewater samples and found that Olivar had up to 3-fold higher mapping rates while retaining similar coverage. In summary, Olivar automates and accelerates the generation of tiled amplicons, even in situations of high mutation frequency and/or density. Olivar is available as a web application at https://olivar.rice.edu . Olivar can also be installed locally as a command line tool with Bioconda. Source code, installation guide and usage are available at https://github.com/treangenlab/Olivar .
Open AccessOlivar: automated variant aware primer design for multiplex tiled amplicon sequencing of pathogens
Tiled amplicon sequencing has served as an essential tool for tracking the spread and evolution of pathogens. Over 2 million complete SARS-CoV-2 genomes are now publicly available, most sequenced and assembled via tiled amplicon sequencing. While computational tools for tiled amplicon design exist, they require downstream manual optimization both computationally and experimentally, which is slow and costly. Here we present Olivar, a first step towards a fully automated, variant-aware design of tiled amplicons for pathogen genomes. Olivar converts each nucleotide of the target genome into a numeric risk score, capturing undesired sequence features that should be avoided. In a direct comparison with PrimalScheme, we show that Olivar has fewer SNPs overlapping with primers and predicted PCR byproducts. We also compared Olivar head-to-head with ARTIC v4.1, the most widely used primer set for SARS-CoV-2 sequencing, and show Olivar yields similar read mapping rates (∼90%) and better coverage to the manually designed ARTIC v4.1 amplicons. We also evaluated Olivar on real wastewater samples and found that Olivar had up to 3-fold higher mapping rates while retaining similar coverage. In summary, Olivar automates and accelerates the generation of tiled amplicons, even in situations of high mutation frequency and/or density. Olivar is available as a web application at https://olivar.rice.edu . Olivar can also be installed locally as a command line tool with Bioconda. Source code, installation guide and usage are available at https://github.com/treangenlab/Olivar .
- Open Access
- 11 April 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-10
Designing highly multiplex PCR primer sets with Simulated Annealing Design using Dimer Likelihood Estimation (SADDLE)
One major challenge in the design of highly multiplexed PCR primer sets is the large number of potential primer dimer species that grows quadratically with the number of primers to be designed. Simultaneously, there are exponentially many choices for multiplex primer sequence selection, resulting in systematic evaluation approaches being computationally intractable. Here, we present and experimentally validate Simulated Annealing Design using Dimer Likelihood Estimation (SADDLE), a stochastic algorithm for design of multiplex PCR primer sets that minimize primer dimer formation. In a 96-plex PCR primer set (192 primers), the fraction of primer dimers decreases from 90.7% in a naively designed primer set to 4.9% in our optimized primer set. Even when scaling to 384-plex (768 primers), the optimized primer set maintains low dimer fraction. In addition to NGS, SADDLE-designed primer sets can also be used in qPCR settings to allow highly multiplexed detection of gene fusions in cDNA, with a single-tube assay comprising 60 primers detecting 56 distinct gene fusions recurrently observed in lung cancer.
- 11 April 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-10
Open AccessDesigning highly multiplex PCR primer sets with Simulated Annealing Design using Dimer Likelihood Estimation (SADDLE)
One major challenge in the design of highly multiplexed PCR primer sets is the large number of potential primer dimer species that grows quadratically with the number of primers to be designed. Simultaneously, there are exponentially many choices for multiplex primer sequence selection, resulting in systematic evaluation approaches being computationally intractable. Here, we present and experimentally validate Simulated Annealing Design using Dimer Likelihood Estimation (SADDLE), a stochastic algorithm for design of multiplex PCR primer sets that minimize primer dimer formation. In a 96-plex PCR primer set (192 primers), the fraction of primer dimers decreases from 90.7% in a naively designed primer set to 4.9% in our optimized primer set. Even when scaling to 384-plex (768 primers), the optimized primer set maintains low dimer fraction. In addition to NGS, SADDLE-designed primer sets can also be used in qPCR settings to allow highly multiplexed detection of gene fusions in cDNA, with a single-tube assay comprising 60 primers detecting 56 distinct gene fusions recurrently observed in lung cancer.
- Open Access
- 4 April 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-9
Ensemble of nucleic acid absolute quantitation modules for copy number variation detection and RNA profiling
Current gold standard for absolute quantitation of a specific DNA sequence is droplet digital PCR (ddPCR), which has been applied to copy number variation (CNV) detection. However, the number of quantitation modules in ddPCR is limited by fluorescence channels, which thus limits the CNV sensitivity due to sampling error following Poisson distribution. Here we develop a PCR-based molecular barcoding NGS approach, quantitative amplicon sequencing (QASeq), for accurate absolute quantitation scalable to over 200 quantitation modules. By attaching barcodes to individual target molecules with high efficiency, 2-plex QASeq exhibits higher and more consistent conversion yield than ddPCR in absolute molecule count quantitation. Multiplexed QASeq improves CNV sensitivity allowing confident distinguishment of 2.05 ploidy from normal 2.00 ploidy. We apply multiplexed QASeq to serial longitudinal plasma cfDNA samples from patients with metastaticERBB2+ (HER2+ ) breast cancer seeking association with tumor progression. We further show an RNA QASeq panel for targeted expression profiling.
- 4 April 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-9
Open AccessEnsemble of nucleic acid absolute quantitation modules for copy number variation detection and RNA profiling
Current gold standard for absolute quantitation of a specific DNA sequence is droplet digital PCR (ddPCR), which has been applied to copy number variation (CNV) detection. However, the number of quantitation modules in ddPCR is limited by fluorescence channels, which thus limits the CNV sensitivity due to sampling error following Poisson distribution. Here we develop a PCR-based molecular barcoding NGS approach, quantitative amplicon sequencing (QASeq), for accurate absolute quantitation scalable to over 200 quantitation modules. By attaching barcodes to individual target molecules with high efficiency, 2-plex QASeq exhibits higher and more consistent conversion yield than ddPCR in absolute molecule count quantitation. Multiplexed QASeq improves CNV sensitivity allowing confident distinguishment of 2.05 ploidy from normal 2.00 ploidy. We apply multiplexed QASeq to serial longitudinal plasma cfDNA samples from patients with metastaticERBB2+ (HER2+ ) breast cancer seeking association with tumor progression. We further show an RNA QASeq panel for targeted expression profiling.