Weiguo Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Weiguo Li has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jieqing Li
Institute of Radiation Medicine, Shandong First Medical University, Shandong Academy of Medical Sciences, Jinan, China
2 shared publications - Lianying Fang
Institute of Radiation Medicine, Shandong First Medical University, Shandong Academy of Medical Sciences, Jinan, China
2 shared publications Chenxing Liao
School of Public Health and Health Management, Shandong First Medical University (Shandong Academy of Medical Sciences), Jinan, China
1 shared publicationGuangfen Du
Department of Medical Imaging, The Fifth People’s Hospital of Jinan, Jinan, China
1 shared publication- Guangfen Du
The Fifth People’s Hospital of Jinan City, Jinan, China
1 shared publication Haiqing Wang
Dongying Center for Disease Control and Prevention, Dong ying, Shandong, China
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by SAGE Publications in Dose-Response
- Vol. 23 (1)
Effects of Low Dose Neutron-Gamma Field on Cell Cycle and Damage of Human Lymphocytes
Purpose: The aim is to investigate the response of peripheral blood lymphocytes to a low-dose neutron-gamma field. Methods: The human peripheral blood was exposed to low-dose neutron-gamma radiation ex vivo. Flow cytometry was utilized to evaluate the changes in cell cycle and protein levels of p21, CDK2, and γH2AX. qPCR analysis was conducted to investigate the mRNA transcription of p21 and CDK2. The chromosomes aberration and micronucleus rate in peripheral blood lymphocytes were observed by microscope. Results: Within the radiation dose range of 0-5976 μGy, compared to the “0” dose group, there was an increase in the proportion of cells in G1 phase and a decrease in the proportion of cells in G2 phase. Additionally, there was an upregulation of p21 and γH2AX protein expression, a downregulation of CDK2 protein expression, and an increase in transcription levels of p21 and CDK2 mRNA. Furthermore, there was an elevation in the rate of chromosome aberrations in peripheral blood lymphocytes; however, no significant change of micronuclei rate was observed. Conclusions: The response of human lymphocytes to low dose neutron gamma irradiation can be reflected by the changes of cell cycle, chromosome aberration and RPS18 expression.
- 1 January 2025
- Published by SAGE Publications in Dose-Response
- Vol. 23 (1)
Open AccessEffects of Low Dose Neutron-Gamma Field on Cell Cycle and Damage of Human Lymphocytes
Purpose: The aim is to investigate the response of peripheral blood lymphocytes to a low-dose neutron-gamma field. Methods: The human peripheral blood was exposed to low-dose neutron-gamma radiation ex vivo. Flow cytometry was utilized to evaluate the changes in cell cycle and protein levels of p21, CDK2, and γH2AX. qPCR analysis was conducted to investigate the mRNA transcription of p21 and CDK2. The chromosomes aberration and micronucleus rate in peripheral blood lymphocytes were observed by microscope. Results: Within the radiation dose range of 0-5976 μGy, compared to the “0” dose group, there was an increase in the proportion of cells in G1 phase and a decrease in the proportion of cells in G2 phase. Additionally, there was an upregulation of p21 and γH2AX protein expression, a downregulation of CDK2 protein expression, and an increase in transcription levels of p21 and CDK2 mRNA. Furthermore, there was an elevation in the rate of chromosome aberrations in peripheral blood lymphocytes; however, no significant change of micronuclei rate was observed. Conclusions: The response of human lymphocytes to low dose neutron gamma irradiation can be reflected by the changes of cell cycle, chromosome aberration and RPS18 expression.
- Open Access
- 23 November 2020
- Published by Springer Nature in SN Comprehensive Clinical Medicine
- Vol. 2 (12) , 2595-2599
Anxiety and Depression Among Imaging Doctors in Post-COVID-19 Period
To investigate the mental state of medical imaging staff in Shandong Province, China, who have been on the forefront of the COVID-19 epidemic during its late stage in China. Questionnaires designed to assess anxiety and depression were administered on-location, and 5331 complete results were collected. SPSS software was used for statistical descriptions and analysis. Rates of anxiety disorders and depression among medical imaging workers in Shandong Province, China, were 6.1% and 6.5%, respectively, higher than those of anxiety and depression in Chinese residents before the epidemic. The outbreak in Xinjiang, China; virus mutation in Japan; and spread of the epidemic due to occupational errors were the primary reported causes of anxiety and depression among image workers. Medical imaging workers showed evidence of psychological abnormalities during the late stage of the epidemic in China.
- 23 November 2020
- Published by Springer Nature in SN Comprehensive Clinical Medicine
- Vol. 2 (12) , 2595-2599
Open AccessAnxiety and Depression Among Imaging Doctors in Post-COVID-19 Period
To investigate the mental state of medical imaging staff in Shandong Province, China, who have been on the forefront of the COVID-19 epidemic during its late stage in China. Questionnaires designed to assess anxiety and depression were administered on-location, and 5331 complete results were collected. SPSS software was used for statistical descriptions and analysis. Rates of anxiety disorders and depression among medical imaging workers in Shandong Province, China, were 6.1% and 6.5%, respectively, higher than those of anxiety and depression in Chinese residents before the epidemic. The outbreak in Xinjiang, China; virus mutation in Japan; and spread of the epidemic due to occupational errors were the primary reported causes of anxiety and depression among image workers. Medical imaging workers showed evidence of psychological abnormalities during the late stage of the epidemic in China.
- Open Access
- 1 July 2020
- Published by SAGE Publications in Dose-Response
- Vol. 18 (3)
Exposure Doses to Technologists Working in 7 PET/CT Departments
Objective: The aim of this study was to measure occupational exposure doses of technologists who dispense and inject radiopharmaceuticals in 7 positron emission tomography/computed tomography (PET/CT) departments. This was done with the goal to help improving protective designs in PET departments and/or establishing national protection standards. Method: Common LiF thermoluminescence dosimeters (TLDs) were placed on the chest and necklace of the technologists to monitor whole-body and thyroid doses, respectively. Ring TLDs were also worn on both index fingers to measure individual hand doses. All TLDs were assembled and measured once every 3 months for a total of 12 months. Additionally, we measured and compared the dose of TLDs attached to both the inside and the outside of the technologist’s lead coat. Results: Technologists received relatively high exposures, which accounted for 64% to 94% of the collective dose in their respective departments. Their thyroid doses ranged from 1.2 to 1.7 mSv/a; some technologists’ hand doses exceeded 500 mSv/a. Use of a lead coat reduced the average dose by 8%. Conclusion: Technologists working in PET/CT departments were the main population exposed to radiation. This work underscores the need for enhanced protective measures for these workers to better reduce their exposure, particularly for their hands.
- 1 July 2020
- Published by SAGE Publications in Dose-Response
- Vol. 18 (3)
Open AccessExposure Doses to Technologists Working in 7 PET/CT Departments
Objective: The aim of this study was to measure occupational exposure doses of technologists who dispense and inject radiopharmaceuticals in 7 positron emission tomography/computed tomography (PET/CT) departments. This was done with the goal to help improving protective designs in PET departments and/or establishing national protection standards. Method: Common LiF thermoluminescence dosimeters (TLDs) were placed on the chest and necklace of the technologists to monitor whole-body and thyroid doses, respectively. Ring TLDs were also worn on both index fingers to measure individual hand doses. All TLDs were assembled and measured once every 3 months for a total of 12 months. Additionally, we measured and compared the dose of TLDs attached to both the inside and the outside of the technologist’s lead coat. Results: Technologists received relatively high exposures, which accounted for 64% to 94% of the collective dose in their respective departments. Their thyroid doses ranged from 1.2 to 1.7 mSv/a; some technologists’ hand doses exceeded 500 mSv/a. Use of a lead coat reduced the average dose by 8%. Conclusion: Technologists working in PET/CT departments were the main population exposed to radiation. This work underscores the need for enhanced protective measures for these workers to better reduce their exposure, particularly for their hands.