Marcello Papini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Marcello Papini has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
- Jan K. Spelt
University of Toronto
7 shared publications - Mark R. Towler
Faculty of Engineering and Architectural Science, Biomedical Engineering Program, Ryerson University, Toronto, ON M5B 2K3, Canada
5 shared publications P. Zalzal
Oakville Trafalgar Memorial Hospital, Oakville Ontario, Canada L6J 3L7
5 shared publications- Adel Alhalawani
Li Ka Shing Knowledge Institute, St. Michael’s Hospital, Toronto, ON M5B 1W8, Canada
3 shared publications Mark R. Towler
Department of Mechanical & Industrial Engineering, Ryerson University, Toronto, Ontario, Canada; Li Ka Shing Knowledge Institute, St. Michael's Hospital, Toronto, Ontario, Canada
3 shared publications- Paul Zalzal
Faculty of Medicine, Department of Surgery, McMaster University, Hamilton, ON L8S 4L8, Canada
3 shared publications
Latest Publications
- Open Access
- 3 May 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (5) , 198
Review of Biomechanical Studies and Finite Element Modeling of Sternal Closure Using Bio-Active Adhesives
The most common complication of median sternotomy surgery is sternum re-separation after sternal fixation, which leads to high rates of morbidity and mortality. The adhered sternal fixation technique comprises the wiring fixation technique and the use of bio-adhesives. Adhered sternal fixation techniques have not been extensively studied using finite element analysis, so mechanical testing studies and finite element analysis of sternal fixation will be presented in this review to find the optimum techniques for simulating sternal fixation with adhesives. The optimal wiring technique should enhance bone stability and limit sternal displacement. Bio-adhesives have been proposed to support sternal fixation, as wiring is prone to failure in cases of post-operative problems. The aim of this paper is to review and present the existing numerical and biomechanical sternal fixation studies by reviewing common sternal closure techniques, adhesives for sternal closure, biomechanical modeling of sternal fixation, and finite element modeling of sternal fixation systems. Investigating the physical behavior of 3D sternal fixation models by finite element analysis (FEA) will lower the expense of conducting clinical trials. This indicates that FEA studies of sternal fixation with adhesives are needed to analyze the efficiency of this sternal closure technique virtually.
- 3 May 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (5) , 198
Open AccessReview of Biomechanical Studies and Finite Element Modeling of Sternal Closure Using Bio-Active Adhesives
The most common complication of median sternotomy surgery is sternum re-separation after sternal fixation, which leads to high rates of morbidity and mortality. The adhered sternal fixation technique comprises the wiring fixation technique and the use of bio-adhesives. Adhered sternal fixation techniques have not been extensively studied using finite element analysis, so mechanical testing studies and finite element analysis of sternal fixation will be presented in this review to find the optimum techniques for simulating sternal fixation with adhesives. The optimal wiring technique should enhance bone stability and limit sternal displacement. Bio-adhesives have been proposed to support sternal fixation, as wiring is prone to failure in cases of post-operative problems. The aim of this paper is to review and present the existing numerical and biomechanical sternal fixation studies by reviewing common sternal closure techniques, adhesives for sternal closure, biomechanical modeling of sternal fixation, and finite element modeling of sternal fixation systems. Investigating the physical behavior of 3D sternal fixation models by finite element analysis (FEA) will lower the expense of conducting clinical trials. This indicates that FEA studies of sternal fixation with adhesives are needed to analyze the efficiency of this sternal closure technique virtually.
- 12 April 2022
- Published by Springer Nature in Tribology Letters
- Vol. 70 (2) , 1-19
Numerical Simulation of Solid Particle Erosion of Alumina by Overlapping Irregular-Shaped Particle Impacts
- 12 April 2022
- Published by Springer Nature in Tribology Letters
- Vol. 70 (2) , 1-19
Numerical Simulation of Solid Particle Erosion of Alumina by Overlapping Irregular-Shaped Particle Impacts
- 1 February 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 126, 105018
Adhesion of bioactive glass-based adhesive to bone
- 1 February 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 126, 105018
Adhesion of bioactive glass-based adhesive to bone
- Open Access
- 5 August 2021
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 12 (3) , 44
Comparative Evaluation of Two Glass Polyalkenoate Cements: An In Vivo Pilot Study Using a Sheep Model
Poly(methyl methacrylate) (PMMA) is used to manage bone loss in revision total knee arthroplasty (rTKA). However, the application of PMMA has been associated with complications such as volumetric shrinkage, necrosis, wear debris, and loosening. Glass polyalkenoate cements (GPCs) have potential bone cementation applications. Unlike PMMA, GPC does not undergo volumetric shrinkage, adheres chemically to bone, and does not undergo an exothermic setting reaction. In this study, two different compositions of GPCs (GPCA and GPCB), based on the patented glass system SiO2-CaO-SrO-P2O5-Ta2O5, were investigated. Working and setting times, pH, ion release, compressive strength, and cytotoxicity of each composition were assessed, and based on the results of these tests, three sets of samples from GPCA were implanted into the distal femur and proximal tibia of three sheep (alongside PMMA as control). Clinical CT scans and micro-CT images obtained at 0, 6, and 12 weeks revealed the varied radiological responses of sheep bone to GPCA. One GPCA sample (implanted in the sheep for 12 weeks) was characterized with no bone resorption. Furthermore, a continuous bone–cement interface was observed in the CT images of this sample. The other implanted GPCA showed a thin radiolucent border at six weeks, indicating some bone resorption occurred. The third sample showed extensive bone resorption at both six and 12 weeks. Possible speculative factors that might be involved in the varied response can be: excessive Zn2+ ion release, low pH, mixing variability, and difficulty in inserting the samples into different parts of the sheep bone.
- 5 August 2021
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 12 (3) , 44
Open AccessComparative Evaluation of Two Glass Polyalkenoate Cements: An In Vivo Pilot Study Using a Sheep Model
Poly(methyl methacrylate) (PMMA) is used to manage bone loss in revision total knee arthroplasty (rTKA). However, the application of PMMA has been associated with complications such as volumetric shrinkage, necrosis, wear debris, and loosening. Glass polyalkenoate cements (GPCs) have potential bone cementation applications. Unlike PMMA, GPC does not undergo volumetric shrinkage, adheres chemically to bone, and does not undergo an exothermic setting reaction. In this study, two different compositions of GPCs (GPCA and GPCB), based on the patented glass system SiO2-CaO-SrO-P2O5-Ta2O5, were investigated. Working and setting times, pH, ion release, compressive strength, and cytotoxicity of each composition were assessed, and based on the results of these tests, three sets of samples from GPCA were implanted into the distal femur and proximal tibia of three sheep (alongside PMMA as control). Clinical CT scans and micro-CT images obtained at 0, 6, and 12 weeks revealed the varied radiological responses of sheep bone to GPCA. One GPCA sample (implanted in the sheep for 12 weeks) was characterized with no bone resorption. Furthermore, a continuous bone–cement interface was observed in the CT images of this sample. The other implanted GPCA showed a thin radiolucent border at six weeks, indicating some bone resorption occurred. The third sample showed extensive bone resorption at both six and 12 weeks. Possible speculative factors that might be involved in the varied response can be: excessive Zn2+ ion release, low pH, mixing variability, and difficulty in inserting the samples into different parts of the sheep bone.
- Open Access
- 1 December 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (12) , 125101
Inertial particle separation in helical channels: A calibrated numerical analysis
Inertial microfluidics has been used in recent years to separate particles by size, with most efforts focusing on spiral channels with rectangular cross sections. Typically, particles of different sizes have been separated by ensuring that they occupy different equilibrium positions near the inner wall. Trapezoidal cross sections have been shown to improve separation efficiency by entraining one size of particles in Dean vortices near the outer wall and inertially focusing larger particles near the inner wall. Recently, this principle was applied to a helical channel to develop a small-footprint microfluidic device for size-based particle separation and sorting. Despite the promise of these helical devices, the effects of channel geometry and other process parameters on separation efficiency remain unexplored. In this paper, a simplified numerical model was used to estimate the effect of various geometric parameters such as channel pitch, diameter, taper angle, depth, and width on the propensity for particle separation. This study can be used to aid in the design of microfluidic devices for optimal size-based inertial particle separation.
- 1 December 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (12) , 125101
Open AccessInertial particle separation in helical channels: A calibrated numerical analysis
Inertial microfluidics has been used in recent years to separate particles by size, with most efforts focusing on spiral channels with rectangular cross sections. Typically, particles of different sizes have been separated by ensuring that they occupy different equilibrium positions near the inner wall. Trapezoidal cross sections have been shown to improve separation efficiency by entraining one size of particles in Dean vortices near the outer wall and inertially focusing larger particles near the inner wall. Recently, this principle was applied to a helical channel to develop a small-footprint microfluidic device for size-based particle separation and sorting. Despite the promise of these helical devices, the effects of channel geometry and other process parameters on separation efficiency remain unexplored. In this paper, a simplified numerical model was used to estimate the effect of various geometric parameters such as channel pitch, diameter, taper angle, depth, and width on the propensity for particle separation. This study can be used to aid in the design of microfluidic devices for optimal size-based inertial particle separation.
- 1 November 2020
- Published by AIP Publishing in Biomicrofluidics
- Vol. 14 (6) , 064104
Lab on a rod: Size-based particle separation and sorting in a helical channel
Size-based particle separation using inertial microfluidics in spiral channels has been well studied over the past decade. Though these devices can effectively separate particles, they require a relatively large device footprint with a typical outer channel radius of approximately 15 mm. In this paper, we describe a microfluidic device with a footprint diameter of 5.5 mm, containing a helical channel capable of inertial particle separation fabricated using abrasive jet micromachining. The separation of particles in several channel geometries was studied using wide-field fluorescence microscopy. A maximum separation efficiency of approximately 90% was achieved at a flow rate of 1.5 ml/min with a purity of approximately 95% at the outlet, where large particles were collected. An accompanying computational fluid dynamics model was developed to allow researchers to quickly assess the separation capability of their helical or spiral devices.
- 1 November 2020
- Published by AIP Publishing in Biomicrofluidics
- Vol. 14 (6) , 064104
Lab on a rod: Size-based particle separation and sorting in a helical channel
Size-based particle separation using inertial microfluidics in spiral channels has been well studied over the past decade. Though these devices can effectively separate particles, they require a relatively large device footprint with a typical outer channel radius of approximately 15 mm. In this paper, we describe a microfluidic device with a footprint diameter of 5.5 mm, containing a helical channel capable of inertial particle separation fabricated using abrasive jet micromachining. The separation of particles in several channel geometries was studied using wide-field fluorescence microscopy. A maximum separation efficiency of approximately 90% was achieved at a flow rate of 1.5 ml/min with a purity of approximately 95% at the outlet, where large particles were collected. An accompanying computational fluid dynamics model was developed to allow researchers to quickly assess the separation capability of their helical or spiral devices.
- 24 September 2020
- Published by Wiley in Polymer Composites
- Vol. 42 (1) , 220-235
Numerical and experimental investigation of the erosion of zirconia particulate‐reinforced epoxy matrix composites by angular silicon carbide particles
An smooth particle hydrodynamics/finite element (SPH/FEM) model was developed to simulate the erosion of zirconia particle‐reinforced epoxy composites, due to the overlapping impacts of angular particles at both perpendicular and oblique incidences. For each composite target, multiple sub‐volumes, each having their own random reinforcement distribution, were modeled. The reinforcements were assumed as noneroding and nondeforming and were distributed in the modeled sub‐volumes according to the random distributions measured in the actual samples. Erosion tests were performed to verify the numerical model, and it was found that the erosion rates of the zirconia‐reinforced composites were in all cases significantly lower than the neat epoxy. The experimentally‐observed erosion mechanisms were successfully simulated by the model, and the predicted erosion rates matched the measured ones to within 2% to 11%. It is anticipated that similar models can be used to predict erosion of other particulate composite systems whose reinforcement erosion and fracture is negligible compared to the matrix erosion.
- 24 September 2020
- Published by Wiley in Polymer Composites
- Vol. 42 (1) , 220-235
Numerical and experimental investigation of the erosion of zirconia particulate‐reinforced epoxy matrix composites by angular silicon carbide particles
An smooth particle hydrodynamics/finite element (SPH/FEM) model was developed to simulate the erosion of zirconia particle‐reinforced epoxy composites, due to the overlapping impacts of angular particles at both perpendicular and oblique incidences. For each composite target, multiple sub‐volumes, each having their own random reinforcement distribution, were modeled. The reinforcements were assumed as noneroding and nondeforming and were distributed in the modeled sub‐volumes according to the random distributions measured in the actual samples. Erosion tests were performed to verify the numerical model, and it was found that the erosion rates of the zirconia‐reinforced composites were in all cases significantly lower than the neat epoxy. The experimentally‐observed erosion mechanisms were successfully simulated by the model, and the predicted erosion rates matched the measured ones to within 2% to 11%. It is anticipated that similar models can be used to predict erosion of other particulate composite systems whose reinforcement erosion and fracture is negligible compared to the matrix erosion.
- 1 July 2020
- Published by AIP Publishing in Biomicrofluidics
- Vol. 14 (4) , 044103
A novel abrasive water jet machining technique for rapid fabrication of three-dimensional microfluidic components
Microfluidic lab-on-a-chip devices are usually fabricated using replica molding, with poly(dimethylsiloxane) (PDMS) casting on a mold. Most common techniques used to fabricate microfluidic molds, such as photolithography and soft lithography, require costly facilities such as a cleanroom, and complicated steps, especially for the fabrication of three-dimensional (3D) features. For example, an often-desired 3D microchannel feature consists of intersecting channels with depth variations. This type of 3D flow focusing geometry has applications in flow cytometry and droplet generation. Various manufacturing techniques have recently been developed for the rapid fabrication of such 3D microfluidic features. In this paper, we describe a new method of mold fabrication that utilizes water jet cutting technology to fabricate free-standing structures on mild steel sheets to make a mold for PDMS casting. As a proof-of-concept, we use this fabrication technique to make a PDMS chip that has a 3D flow focusing junction, an inlet for the sample fluid, two inlets for the sheath fluid, and an outlet. The flow focusing junction is patterned into the PDMS slab with an abrupt, nearly stepwise change to the depth of the microchannel junction. We use confocal microscopy to visualize the 3D flow focusing of a sample flow using this geometry, and we also use the same geometry to generate water-in-oil droplets. This alternative approach to create microfluidic molds is versatile and may find utility in reducing the cost and complexity involved in fabricating 3D features in microfluidic devices.
- 1 July 2020
- Published by AIP Publishing in Biomicrofluidics
- Vol. 14 (4) , 044103
A novel abrasive water jet machining technique for rapid fabrication of three-dimensional microfluidic components
Microfluidic lab-on-a-chip devices are usually fabricated using replica molding, with poly(dimethylsiloxane) (PDMS) casting on a mold. Most common techniques used to fabricate microfluidic molds, such as photolithography and soft lithography, require costly facilities such as a cleanroom, and complicated steps, especially for the fabrication of three-dimensional (3D) features. For example, an often-desired 3D microchannel feature consists of intersecting channels with depth variations. This type of 3D flow focusing geometry has applications in flow cytometry and droplet generation. Various manufacturing techniques have recently been developed for the rapid fabrication of such 3D microfluidic features. In this paper, we describe a new method of mold fabrication that utilizes water jet cutting technology to fabricate free-standing structures on mild steel sheets to make a mold for PDMS casting. As a proof-of-concept, we use this fabrication technique to make a PDMS chip that has a 3D flow focusing junction, an inlet for the sample fluid, two inlets for the sheath fluid, and an outlet. The flow focusing junction is patterned into the PDMS slab with an abrupt, nearly stepwise change to the depth of the microchannel junction. We use confocal microscopy to visualize the 3D flow focusing of a sample flow using this geometry, and we also use the same geometry to generate water-in-oil droplets. This alternative approach to create microfluidic molds is versatile and may find utility in reducing the cost and complexity involved in fabricating 3D features in microfluidic devices.
- 30 April 2020
- Published by Springer Nature in Tribology Letters
- Vol. 68 (2) , 1-15
Numerical Simulation of Solid Particle Erosion of Epoxy by Overlapping Angular Particle Impacts
- 30 April 2020
- Published by Springer Nature in Tribology Letters
- Vol. 68 (2) , 1-15
Numerical Simulation of Solid Particle Erosion of Epoxy by Overlapping Angular Particle Impacts
- Open Access
- 10 April 2020
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 11 (2) , 25
The Role of Poly(Methyl Methacrylate) in Management of Bone Loss and Infection in Revision Total Knee Arthroplasty: A Review
Poly(methyl methacrylate) (PMMA) is widely used in joint arthroplasty to secure an implant to the host bone. Complications including fracture, bone loss and infection might cause failure of total knee arthroplasty (TKA), resulting in the need for revision total knee arthroplasty (rTKA). The goals of this paper are: (1) to identify the most common complications, outside of sepsis, arising from the application of PMMA following rTKA, (2) to discuss the current applications and drawbacks of employing PMMA in managing bone loss, (3) to review the role of PMMA in addressing bone infection following complications in rTKA. Papers published between 1970 to 2018 have been considered through searching in Springer, Google Scholar, IEEE Xplore, Engineering village, PubMed and weblinks. This review considers the use of PMMA as both a bone void filler and as a spacer material in two-stage revision. To manage bone loss, PMMA is widely used to fill peripheral bone defects whose depth is less than 5 mm and covers less than 50% of the bone surface. Treatment of bone infections with PMMA is mainly for two-stage rTKA where antibiotic-loaded PMMA is inserted as a spacer. This review also shows that using antibiotic-loaded PMMA might cause complications such as toxicity to surrounding tissue, incomplete antibiotic agent release from the PMMA, roughness and bacterial colonization on the surface of PMMA. Although PMMA is the only commercial bone cement used in rTKA, there are concerns associated with using PMMA following rTKA. More research and clinical studies are needed to address these complications.
- 10 April 2020
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 11 (2) , 25
Open AccessThe Role of Poly(Methyl Methacrylate) in Management of Bone Loss and Infection in Revision Total Knee Arthroplasty: A Review
Poly(methyl methacrylate) (PMMA) is widely used in joint arthroplasty to secure an implant to the host bone. Complications including fracture, bone loss and infection might cause failure of total knee arthroplasty (TKA), resulting in the need for revision total knee arthroplasty (rTKA). The goals of this paper are: (1) to identify the most common complications, outside of sepsis, arising from the application of PMMA following rTKA, (2) to discuss the current applications and drawbacks of employing PMMA in managing bone loss, (3) to review the role of PMMA in addressing bone infection following complications in rTKA. Papers published between 1970 to 2018 have been considered through searching in Springer, Google Scholar, IEEE Xplore, Engineering village, PubMed and weblinks. This review considers the use of PMMA as both a bone void filler and as a spacer material in two-stage revision. To manage bone loss, PMMA is widely used to fill peripheral bone defects whose depth is less than 5 mm and covers less than 50% of the bone surface. Treatment of bone infections with PMMA is mainly for two-stage rTKA where antibiotic-loaded PMMA is inserted as a spacer. This review also shows that using antibiotic-loaded PMMA might cause complications such as toxicity to surrounding tissue, incomplete antibiotic agent release from the PMMA, roughness and bacterial colonization on the surface of PMMA. Although PMMA is the only commercial bone cement used in rTKA, there are concerns associated with using PMMA following rTKA. More research and clinical studies are needed to address these complications.