JWJianyong Wang

Jianyong Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jianyong Wang has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Integrated Impact of Post-TAVR Cardiac Damage and Pacemaker Implantation on Long-Term Outcomes

    by Xinyue Yang, Ruisi Tang, Yijun Yao, Fei Chen, Xingzhou Pu, Xi Wang, Jianyong Wang, Chengqiang Liao, Yun Bao, Chao Li, et al.

    Background/Objectives: Post-procedural permanent pacemaker implantation (PPMI) and cardiac damage are individually associated with adverse outcomes following transcatheter aortic valve replacement (TAVR). However, their joint impact has not been systematically evaluated. Methods: Individuals who underwent TAVR procedures between 2013 and 2024 were retrospectively enrolled and classified into four groups based on their PPMI and cardiac damage status. Univariate and multivariable Cox regression were used to analyze the association of these factors with long-term outcomes, while receiver operating characteristic (ROC) curves, decision curve analysis (DCA), net reclassification improvement (NRI), and integrated discrimination improvement (IDI) were used to further assess their predictive performance. Results: A total of 1274 patients met the inclusion criteria. Compared to non-PPMI patients with early cardiac damage stage, those with PPMI and advanced stage had higher all-cause mortality (HR: 2.98; 95% CI: 1.60–5.56; p value < 0.001) and more cardiac deaths (HR: 3.85; 95% CI: 1.36–11.10; p = 0.012). Multivariable analysis confirmed PPMI and cardiac damage stage as independent prognostic factors. Notably, the predictive model incorporating both variables achieved the best performance (AUC = 0.703) with significant NRI and favorable DCA results, suggesting incremental value for identifying high-risk patients and acceptable clinical utility. Conclusions: The current study is among the first to explore whether post-procedural cardiac damage may identify a subgroup in whom PPMI carries a particularly adverse long-term prognosis, highlighting the need for integrated risk assessment for post-TAVR lifelong management.

  • Open Access

    Neural Network-Based Prediction of Residual Paravalvular Leak in Bicuspid Aortic Valve TAVI Using CT-Derived Anatomical Features

    by Yijun Yao, Weili Jiang, Xinyue Yang, Jianyong Wang, Ruisi Tang, Yuan Feng, Yiming Li, Mao Chen

    Background/Objectives: Transcatheter aortic valve implantation (TAVI) in patients with bicuspid aortic valve (BAV) remains associated with higher rates of residual paravalvular leak (PVL), which confers a two-fold increase in mortality. Despite procedural optimization including balloon post-dilatation, a subset of patients exhibit residual ≥moderate PVL. Pre-procedural identification of these patients could guide procedural planning. Methods: We retrospectively analyzed 402 BAV patients who underwent TAVI with self-expanding valves and balloon post-dilatation between January 2016 and June 2024. A multi-modal deep learning model (Model B) was developed, integrating a 3D ResNet encoder for computed tomography (CT) imaging features with a multilayer perceptron (MLP) for clinical variables, fused via a cross-attention mechanism. Its performance was compared against a conventional model (Model A) combining clinical variables with manually derived CT measurements. Both models were evaluated on identical test folds using 5-fold stratified cross-validation. Results: Of 402 patients, 36 (9.0%) had residual ≥moderate PVL, associated with significantly larger aortic root dimensions at all anatomical levels and greater aortic valve calcification volume (median 887.6 vs. 559.2 mm3; p = 0.004). Model A achieved a mean AUC of 0.694 (95% CI: 0.596–0.792). Model B achieved a mean AUC of 0.822 (95% CI: 0.680–0.964), with a specificity of 0.971, accuracy of 0.881, and PPV of 0.860, while sensitivity was 0.429, reflecting the limited number of outcome events in this cohort. Conclusions: A multi-modal deep learning model integrating expert-segmented CT imaging with clinical variables demonstrated significantly improved discrimination over the conventional approach in this internal cohort for predicting residual PVL in BAV-TAVI, supporting the integration of segmentation-guided deep learning into pre-procedural TAVI planning. However, given the modest number of outcome events, external validation is required to confirm the generalizability of these findings.


  • Coronary Artery Calcification Segmentation by Using Cross-Frequency Conditioner and Geometric Priors Learning

    by Weili Jiang, Yiming Li, Gadeng Luosang, Gang Peng, Yong Peng, Yijun Yao, Zhang Yi, Jianyong Wang, Mao Chen


  • Learning Robust Representations by Autoencoders With Dynamical Implicit Mapping

    by Jianda Zeng, Weili Jiang, Zhang Yi, Yong-Guo Shi, Jianyong Wang

    Autoencoder is an unsupervised neural network that learns effective representations of data and has wide applications in feature learning, data compression, etc. However, Autoencoder is very sensitive to noise, resulting in low generalization and robustness of the model. To solve this problem, we propose a stable and efficient Autoencoder model called nmFunc-Autoencoder. Inspired by the Neural Memory Ordinary Differential Equation, the Neural Memory Activation Function uses its excellent dynamic nonlinear implicit mapping to establish a mapping relationship between external inputs and stable values to ensure the stability of distinguishable feature extraction, thereby performing better robustness when subjected to noise attacks. We conduct robustness experiments to evaluate its performance. The result showed that compared with other Autoencoder models, the data features extracted by the proposed model are more robust. Subsequently, in the execution efficiency experiments and ablation study, the model was shown to be low-cost and effective. The code will be available at https://github.com/OliverCodeOne/nmFunc


  • Open Access

    Efficient visual transformer transferring from neural ODE perspective

    by Hao Niu, Fengming Luo, Bo Yuan, Yi Zhang, Jianyong Wang

    Recently, the Visual Image Transformer (ViT) has revolutionized various domains in computer vision. The transfer of pre‐trained ViT models on large‐scale datasets has proven to be a promising method for downstream tasks. However, traditional transfer methods introduce numerous additional parameters in transformer blocks, posing new challenges in learning downstream tasks. This article proposes an efficient transfer method from the perspective of neural Ordinary Differential Equations (ODEs) to address this issue. On the one hand, the residual connections in the transformer layers can be interpreted as the numerical integration of differential equations. Therefore, the transformer block can be described as two explicit Euler method equations. By dynamically learning the step size in the explicit Euler equation, a highly lightweight method for transferring the transformer block is obtained. On the other hand, a new learnable neural memory ODE block is proposed by taking inspiration from the self‐inhibition mechanism in neural systems. It increases the diversity of dynamical behaviours of the neurons to transfer the head block efficiently and enhances non‐linearity simultaneously. Experimental results in image classification demonstrate that the proposed approach can effectively transfer ViT models and outperform state‐of‐the‐art methods.


  • Automated Quality Assessment of Medical Images in Echocardiography Using Neural Networks with Adaptive Ranking and Structure-Aware Learning

    by Gadeng Luosang, Zhihua Wang, Jian Liu, Fanxin Zeng, Zhang Yi, Jianyong Wang

    The quality of medical images is crucial for accurately diagnosing and treating various diseases. However, current automated methods for assessing image quality are based on neural networks, which often focus solely on pixel distortion and overlook the significance of complex structures within the images. This study introduces a novel neural network model designed explicitly for automated image quality assessment that addresses pixel and semantic distortion. The model introduces an adaptive ranking mechanism enhanced with contrast sensitivity weighting to refine the detection of minor variances in similar images for pixel distortion assessment. More significantly, the model integrates a structure-aware learning module employing graph neural networks. This module is adept at deciphering the intricate relationships between an image’s semantic structure and quality. When evaluated on two ultrasound imaging datasets, the proposed method outshines existing leading models in performance. Additionally, it boasts seamless integration into clinical workflows, enabling real-time image quality assessment, crucial for precise disease diagnosis and treatment.


  • Ori-Net: Orientation-guided Neural Network for Automated Coronary Arteries Segmentation

    by Weili Jiang, Yiming Li, Yuheng Jia, Yuan Feng, Zhang Yi, Mao Chen, Jianyong Wang