Laura K. Young
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Laura K. Young has a total of 132 co-authors. Here are the top co-authors by number of shared publications:
- Gordon D. Love
Department of Physics, Durham University
6 shared publications - Hannah E. Smithson
University of Oxford, Department of Experimental Psychology, Oxford, UK
6 shared publications - John Michael Girkin
Durham University
5 shared publications - Alastair G. Basden
Durham University
3 shared publications Christopher D. Saunter
Department of Physics, Durham University, South Road, Durham DH1 3LE, UK
3 shared publicationsCyril Bourgenot
Durham Univ. (United Kingdom)
3 shared publications
Latest Publications
- Open Access
- 9 November 2023
- Published by Springer Nature
Study of retinal structure and function in retinal disease
- 9 November 2023
- Published by Springer Nature
Open AccessStudy of retinal structure and function in retinal disease
- 8 July 2020
- Published by Springer Nature
- p. 410-419
Simultaneous Optimisation of Confocal and Non-confocal Images in an AOSLO with a Reconfigurable Aperture Pattern
- 8 July 2020
- Published by Springer Nature
- p. 410-419
Simultaneous Optimisation of Confocal and Non-confocal Images in an AOSLO with a Reconfigurable Aperture Pattern
- Open Access
- 1 March 2019
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 54 (3) , 169-176
The Impact of Different Magnetic Resonance Imaging Equipment and Scanning Parameters on Signal Intensity Ratio Measurements in Phantoms and Healthy Volunteers
Objectives: The aim of this study was to examine the variation in signal intensity ratio (SIR) values in Eurospin gel phantoms and healthy volunteer (HV) brain images in response to different magnetic resonance imaging hardware and software settings. Materials and Methods: Gel phantoms with T1 relaxation times similar to the dentate nucleus (DN), pons (P), globus palladus (GP), and thalamus (Th) were scanned using a T1-weighted 2-dimensional spin-echo sequence on 2 magnetic resonance imaging scanners (3 T and 1.5 T). Imaging was performed by sequentially altering selected magnetic resonance (MR) parameters relative to a default pulse sequence, and the protocol was implemented repeatedly over 3 months. The experiment was also repeated on a cohort of 15 young HVs. Calculations of DN/P and GP/Th SIR values were derived for the images of the gels (GelDN/P and GelGP/Th) and the HVs (HVDN/P and HVGP/Th). Results: For the default sequence, the mean SIR values of GelDN/P and GelGP/Th varied by ±2.20% and ±0.75%, respectively, when measured over multiple imaging sessions (3 T). Within a single imaging session, these variations were smaller (±0.17% for GelDN/P and ±0.15% for GelGP/Th). At 1.5 T, the equivalent SIR variations for GelDN/P were ±1.41% (multiple sessions) and ±0.41% (single session), and that for GelGP/Th were ±0.47% (multiple sessions) and ±0.33% (single session). Sequential changes to the MR sequence parameters resulted in gel SIR variations as follows: 14.07% ± 2.43% (with/without normalization filters), −7.80% ± 0.28% (different echo times, TE), and −5.06% ± 0.59% (selective activation of RF coil elements). The largest variations were noted when the gels were positioned below the scanner isocenter, where SIR measurements were different by 22%. For the HVs, the SIR values were found to be consistently within 0.64% (single session) for the default sequence. Sequential changes to the MR sequence parameters resulted in SIR variations of −24.47% ± 2.47% (with/without normalization filters), −15.32% ± 7.71% (different echo times, TE), and −2.90% ± 0.78% (selective activation of RF coil elements). Conclusions: This study has demonstrated that SIR percentage changes from baseline of a similar magnitude to brain gadolinium contrast agent signal hyperintensities can be replicated in phantom models and HVs by altering common MR acquisition parameters and hardware.
- 1 March 2019
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 54 (3) , 169-176
Open AccessThe Impact of Different Magnetic Resonance Imaging Equipment and Scanning Parameters on Signal Intensity Ratio Measurements in Phantoms and Healthy Volunteers
Objectives: The aim of this study was to examine the variation in signal intensity ratio (SIR) values in Eurospin gel phantoms and healthy volunteer (HV) brain images in response to different magnetic resonance imaging hardware and software settings. Materials and Methods: Gel phantoms with T1 relaxation times similar to the dentate nucleus (DN), pons (P), globus palladus (GP), and thalamus (Th) were scanned using a T1-weighted 2-dimensional spin-echo sequence on 2 magnetic resonance imaging scanners (3 T and 1.5 T). Imaging was performed by sequentially altering selected magnetic resonance (MR) parameters relative to a default pulse sequence, and the protocol was implemented repeatedly over 3 months. The experiment was also repeated on a cohort of 15 young HVs. Calculations of DN/P and GP/Th SIR values were derived for the images of the gels (GelDN/P and GelGP/Th) and the HVs (HVDN/P and HVGP/Th). Results: For the default sequence, the mean SIR values of GelDN/P and GelGP/Th varied by ±2.20% and ±0.75%, respectively, when measured over multiple imaging sessions (3 T). Within a single imaging session, these variations were smaller (±0.17% for GelDN/P and ±0.15% for GelGP/Th). At 1.5 T, the equivalent SIR variations for GelDN/P were ±1.41% (multiple sessions) and ±0.41% (single session), and that for GelGP/Th were ±0.47% (multiple sessions) and ±0.33% (single session). Sequential changes to the MR sequence parameters resulted in gel SIR variations as follows: 14.07% ± 2.43% (with/without normalization filters), −7.80% ± 0.28% (different echo times, TE), and −5.06% ± 0.59% (selective activation of RF coil elements). The largest variations were noted when the gels were positioned below the scanner isocenter, where SIR measurements were different by 22%. For the HVs, the SIR values were found to be consistently within 0.64% (single session) for the default sequence. Sequential changes to the MR sequence parameters resulted in SIR variations of −24.47% ± 2.47% (with/without normalization filters), −15.32% ± 7.71% (different echo times, TE), and −2.90% ± 0.78% (selective activation of RF coil elements). Conclusions: This study has demonstrated that SIR percentage changes from baseline of a similar magnitude to brain gadolinium contrast agent signal hyperintensities can be replicated in phantom models and HVs by altering common MR acquisition parameters and hardware.
- Open Access
- 15 August 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (9) , 4275-4293
Compact, modular and in-plane AOSLO for high-resolution retinal imaging
The adaptive optics scanning laser ophthalmoscope (AOSLO) was first developed in 2002 and since then the technology has been adopted in several laboratories around the world, for both clinical and psychophysical research. There have been a few major design implementations of the AOSLO. The first used on-axis tilted spherical mirrors in a planar arrangement, and the second minimized the build up of astigmatism present in the first design by using a non-planar arrangement. Other designs have avoided astigmatism by using custom-made toroidal mirrors or by using lenses on-axis, rather than mirrors. We present a new design implementation for an AOSLO that maintains a planar optical alignment without the build up astigmatism using compact, reconfigurable modules based on an Offner relay system. We additionally use an off-the-shelf digital oscilloscope for data capture and custom-written Python code for generating and analyzing the retinal images. This design results in a compact system that is simple to align and, being composed of modular relays, has the potential for additional components to be added. We show that this system maintains diffraction-limited image quality across the field of view and that cones are clearly resolved in the central retina. The modular relay design is generally applicable to any system requiring one or more components in the pupil conjugate plane. This is likely to be useful for any point-scanned system, such as a standard scanning laser ophthalmoscope or non-ophthalmic confocal imaging system.
- 15 August 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (9) , 4275-4293
Open AccessCompact, modular and in-plane AOSLO for high-resolution retinal imaging
The adaptive optics scanning laser ophthalmoscope (AOSLO) was first developed in 2002 and since then the technology has been adopted in several laboratories around the world, for both clinical and psychophysical research. There have been a few major design implementations of the AOSLO. The first used on-axis tilted spherical mirrors in a planar arrangement, and the second minimized the build up of astigmatism present in the first design by using a non-planar arrangement. Other designs have avoided astigmatism by using custom-made toroidal mirrors or by using lenses on-axis, rather than mirrors. We present a new design implementation for an AOSLO that maintains a planar optical alignment without the build up astigmatism using compact, reconfigurable modules based on an Offner relay system. We additionally use an off-the-shelf digital oscilloscope for data capture and custom-written Python code for generating and analyzing the retinal images. This design results in a compact system that is simple to align and, being composed of modular relays, has the potential for additional components to be added. We show that this system maintains diffraction-limited image quality across the field of view and that cones are clearly resolved in the central retina. The modular relay design is generally applicable to any system requiring one or more components in the pupil conjugate plane. This is likely to be useful for any point-scanned system, such as a standard scanning laser ophthalmoscope or non-ophthalmic confocal imaging system.
- Open Access
- 10 April 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (5) , 2176-2188
Non-invasive in vivo quantification of the developing optical properties and graded index of the embryonic eye lens using SPIM
Graded refractive index lenses are inherent to advanced visual systems in animals. By understanding their formation and local optical properties, significant potential for improved ocular healthcare may be realized. We report a novel technique measuring the developing optical power of the eye lens, in a living animal, by exploiting the orthogonal imaging modality of a selective plane illumination microscope (SPIM). We have quantified the maturation of the lenticular refractive index at three different visible wavelengths using a combined imaging and ray tracing approach. We demonstrate that the method can be used with transgenic and vital dye labeling as well as with both fixed and living animals. Using a key eye lens morphogen and its inhibitor, we have measured their effects both on lens size and on refractive index. Our technique provides insights into the mechanisms involved in the development of this natural graded index micro-lens and its associated optical properties.
- 10 April 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (5) , 2176-2188
Open AccessNon-invasive in vivo quantification of the developing optical properties and graded index of the embryonic eye lens using SPIM
Graded refractive index lenses are inherent to advanced visual systems in animals. By understanding their formation and local optical properties, significant potential for improved ocular healthcare may be realized. We report a novel technique measuring the developing optical power of the eye lens, in a living animal, by exploiting the orthogonal imaging modality of a selective plane illumination microscope (SPIM). We have quantified the maturation of the lenticular refractive index at three different visible wavelengths using a combined imaging and ray tracing approach. We demonstrate that the method can be used with transgenic and vital dye labeling as well as with both fixed and living animals. Using a key eye lens morphogen and its inhibitor, we have measured their effects both on lens size and on refractive index. Our technique provides insights into the mechanisms involved in the development of this natural graded index micro-lens and its associated optical properties.
- 8 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10474, 71
A new concept of imaging system: telescope windows
A Telescope window is a novel concept of transformation-optics consisting of an array of micro-telescopes, in our configuration, of a Galilean type. When the array is considered as one multifaceted device, it acts as a traditional Galilean telescope with distinctive and attractive properties such as compactness and modularity. Each lenslet, can in principle, be independently designed for a specific optical function. In this paper, we report on the design, manufacture and prototyping, by diamond precision machining, of 2 concepts of telescope windows, and discuss both their performances and limitations with a view to use them as potential low vision aid devices to support patients with macular degeneration.
- 8 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10474, 71
A new concept of imaging system: telescope windows
A Telescope window is a novel concept of transformation-optics consisting of an array of micro-telescopes, in our configuration, of a Galilean type. When the array is considered as one multifaceted device, it acts as a traditional Galilean telescope with distinctive and attractive properties such as compactness and modularity. Each lenslet, can in principle, be independently designed for a specific optical function. In this paper, we report on the design, manufacture and prototyping, by diamond precision machining, of 2 concepts of telescope windows, and discuss both their performances and limitations with a view to use them as potential low vision aid devices to support patients with macular degeneration.
- 1 January 2018
- Published by Optica Publishing Group
- p. JTu5B.3
Adaptive Optics for Precise Cell Ablation in vivo
We have combined adaptive optics and opto-genetics with single plane microscopy to ablate single or groups of cells. Results will be presented demonstrating cellular ablation in the heart and kidney.
- 1 January 2018
- Published by Optica Publishing Group
- p. JTu5B.3
Adaptive Optics for Precise Cell Ablation in vivo
We have combined adaptive optics and opto-genetics with single plane microscopy to ablate single or groups of cells. Results will be presented demonstrating cellular ablation in the heart and kidney.
- Open Access
- 11 July 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 5096
Precise spatio-temporal control of rapid optogenetic cell ablation with mem-KillerRed in Zebrafish
The ability to kill individual or groups of cells in vivo is important for studying cellular processes and their physiological function. Cell-specific genetically encoded photosensitizing proteins, such as KillerRed, permit spatiotemporal optogenetic ablation with low-power laser light. We report dramatically improved resolution and speed of cell targeting in the zebrafish kidney through the use of a selective plane illumination microscope (SPIM). Furthermore, through the novel incorporation of a Bessel beam into the SPIM imaging arm, we were able to improve on targeting speed and precision. The low diffraction of the Bessel beam coupled with the ability to tightly focus it through a high NA lens allowed precise, rapid targeting of subsets of cells at anatomical depth in live, developing zebrafish kidneys. We demonstrate that these specific targeting strategies significantly increase the speed of optoablation as well as fish survival.
- 11 July 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 5096
Open AccessPrecise spatio-temporal control of rapid optogenetic cell ablation with mem-KillerRed in Zebrafish
The ability to kill individual or groups of cells in vivo is important for studying cellular processes and their physiological function. Cell-specific genetically encoded photosensitizing proteins, such as KillerRed, permit spatiotemporal optogenetic ablation with low-power laser light. We report dramatically improved resolution and speed of cell targeting in the zebrafish kidney through the use of a selective plane illumination microscope (SPIM). Furthermore, through the novel incorporation of a Bessel beam into the SPIM imaging arm, we were able to improve on targeting speed and precision. The low diffraction of the Bessel beam coupled with the ability to tightly focus it through a high NA lens allowed precise, rapid targeting of subsets of cells at anatomical depth in live, developing zebrafish kidneys. We demonstrate that these specific targeting strategies significantly increase the speed of optoablation as well as fish survival.
- 1 March 2017
- Published by Elsevier in Vision Research
- Vol. 132, 3-33
Vision science and adaptive optics, the state of the field
- 1 March 2017
- Published by Elsevier in Vision Research
- Vol. 132, 3-33
Vision science and adaptive optics, the state of the field