Antonio Rodríguez-Fernández
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Antonio Rodríguez-Fernández has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Joan Lobo-Prat
Affiliation ABLE Human Motion, Barcelona, Spain
8 shared publicationsJosep M. Font-Llagunes
Universitat Politecnica de Catalunya
6 shared publicationsLluis Guirao-Cano
Affiliation Rehabilitation Service, Hospital Universitario Mútua Terrassa, Barcelona, Spain
4 shared publicationsDaniel José Rivas Navas
3 shared publications- Eva María Triviño-Ibáñez
Department of Nuclear Medicine, Hospital Universitario Virgen de las Nieves, Granada, Spain; Instituto de Investigación Biosanitaria ibs. GRANADA, Granada, Spain
3 shared publications - Javier Fernandez
Hospital General Universitario Alicante Alicante Spain
3 shared publications
Latest Publications
- Open Access
- 3 December 2025
- Published by Edicions de la Universitat de Barcelona in Reire Revista D'innovació I Recerca En Educació
- Vol. 18 (extra) , 1-7
Estudi del cas als centres de Ciències de l’Activitat Física i l’Esport a Catalunya sobre la predisposició cap a la innovació docent
INTRODUCCIÓ. La innovació educativa és un fet social que impacta en tots els estaments socials. La universitat no en queda fora. L’objectiu de l’estudi és analitzar la predisposició del professorat universitari cap a la innovació docent a les aules en els estudis de Ciències de l’Activitat Física i de l’Esport (CAFE). MÈTODE. S’ha utilitzat el qüestionari validat sobre el perfil Competencial Innovador del Docent Universitari (CIDU) en una mostra de vuit centres universitaris (públics, concertats i privats) a Catalunya. D’aquests centres, es van obtenir un total de 128 respostes de docents que representaven tot l’espectre contractual possible (catedràtics, doctors, associats, titulars…). RESULTATS. Els resultats han demostrat que hi ha dos perfils de professorat que mostren més predilecció per la innovació docent: les dones i el professorat acreditat (p <.05). DISCUSSIÓ. L’anàlisi del contingut sosté dues idees clau. En primer lloc, que les dones mostren més predisposició a participar en comunitats d’aprenentatge col·laboratives en què s’inclouen les tecnologies de la informació i la comunicació (TIC) com a eines d’innovació. En segon lloc, el professorat dels departaments d’educació física dels centres educatius mostra una inclinació certament superior a la innovació en comparació amb la resta del professorat.
- 3 December 2025
- Published by Edicions de la Universitat de Barcelona in Reire Revista D'innovació I Recerca En Educació
- Vol. 18 (extra) , 1-7
Open AccessEstudi del cas als centres de Ciències de l’Activitat Física i l’Esport a Catalunya sobre la predisposició cap a la innovació docent
INTRODUCCIÓ. La innovació educativa és un fet social que impacta en tots els estaments socials. La universitat no en queda fora. L’objectiu de l’estudi és analitzar la predisposició del professorat universitari cap a la innovació docent a les aules en els estudis de Ciències de l’Activitat Física i de l’Esport (CAFE). MÈTODE. S’ha utilitzat el qüestionari validat sobre el perfil Competencial Innovador del Docent Universitari (CIDU) en una mostra de vuit centres universitaris (públics, concertats i privats) a Catalunya. D’aquests centres, es van obtenir un total de 128 respostes de docents que representaven tot l’espectre contractual possible (catedràtics, doctors, associats, titulars…). RESULTATS. Els resultats han demostrat que hi ha dos perfils de professorat que mostren més predilecció per la innovació docent: les dones i el professorat acreditat (p <.05). DISCUSSIÓ. L’anàlisi del contingut sosté dues idees clau. En primer lloc, que les dones mostren més predisposició a participar en comunitats d’aprenentatge col·laboratives en què s’inclouen les tecnologies de la informació i la comunicació (TIC) com a eines d’innovació. En segon lloc, el professorat dels departaments d’educació física dels centres educatius mostra una inclinació certament superior a la innovació en comparació amb la resta del professorat.
- Open Access
- 27 May 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (5) , e0318039
Randomized, crossover clinical trial on the safety, feasibility, and usability of the ABLE exoskeleton: A comparative study with knee-ankle-foot orthoses
Wearable exoskeletons are emerging as a new tool for gait training. However, comparisons between exoskeletons and conventional orthoses in terms of safety and feasibility are scarce. This study assessed the safety, feasibility, usability, and learning process of using the ABLE Exoskeleton in people with spinal cord injury (SCI) while comparing it with knee-ankle-foot orthoses (KAFOs). In this randomized, crossover clinical trial, 10 patients with chronic complete SCI (T4-T12) conducted a 10-session training and assessment protocol with each device: KAFOs and the ABLE Exoskeleton. Outcomes on safety (adverse events), and feasibility and usability (level of assistance, donning/doffing, therapy activities) were recorded for both devices. Evaluation sessions included standard clinical tests (Timed Up and Go, 10-Meter Walk Test, and 6-Minute Walk Test) to assess gait performance. The therapy metrics (number of steps, distance, gait speed, and standing and walking time) were recorded at each session for the robotic device. Participants quickly learned how to use the ABLE Exoskeleton, showing improvements in all therapy metrics (p<0.05) and the 6-Minute Walk Test (p<0.05). Participants reported less adverse events with the robotic device than KAFOs (17 and 31, respectively). Total donning and doffing time was 43 s faster with the robotic device using comparable levels of assistance. The time to complete the therapy activities was very similar between devices. Overall, participants needed 1 to 4 training sessions to perform essential therapy activities (sit/stand transitions, walking 10 meters, turning around) with both devices using minimum assistance or less. The results of this study show that it is feasible and safe for people with motor complete paraplegia due to SCI (T4-T12) to use the ABLE Exoskeleton for gait training in a rehabilitation hospital setting. The ABLE Exoskeleton proved to be as practical and easy to use as conventional orthoses, with fewer AEs reported when using the exoskeleton versus the KAFOs.
- 27 May 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (5) , e0318039
Open AccessRandomized, crossover clinical trial on the safety, feasibility, and usability of the ABLE exoskeleton: A comparative study with knee-ankle-foot orthoses
Wearable exoskeletons are emerging as a new tool for gait training. However, comparisons between exoskeletons and conventional orthoses in terms of safety and feasibility are scarce. This study assessed the safety, feasibility, usability, and learning process of using the ABLE Exoskeleton in people with spinal cord injury (SCI) while comparing it with knee-ankle-foot orthoses (KAFOs). In this randomized, crossover clinical trial, 10 patients with chronic complete SCI (T4-T12) conducted a 10-session training and assessment protocol with each device: KAFOs and the ABLE Exoskeleton. Outcomes on safety (adverse events), and feasibility and usability (level of assistance, donning/doffing, therapy activities) were recorded for both devices. Evaluation sessions included standard clinical tests (Timed Up and Go, 10-Meter Walk Test, and 6-Minute Walk Test) to assess gait performance. The therapy metrics (number of steps, distance, gait speed, and standing and walking time) were recorded at each session for the robotic device. Participants quickly learned how to use the ABLE Exoskeleton, showing improvements in all therapy metrics (p<0.05) and the 6-Minute Walk Test (p<0.05). Participants reported less adverse events with the robotic device than KAFOs (17 and 31, respectively). Total donning and doffing time was 43 s faster with the robotic device using comparable levels of assistance. The time to complete the therapy activities was very similar between devices. Overall, participants needed 1 to 4 training sessions to perform essential therapy activities (sit/stand transitions, walking 10 meters, turning around) with both devices using minimum assistance or less. The results of this study show that it is feasible and safe for people with motor complete paraplegia due to SCI (T4-T12) to use the ABLE Exoskeleton for gait training in a rehabilitation hospital setting. The ABLE Exoskeleton proved to be as practical and easy to use as conventional orthoses, with fewer AEs reported when using the exoskeleton versus the KAFOs.
- 27 February 2025
- Published by Springer Nature
- p. 199-202
From Clinic to Home: Transitioning Exoskeletons from Rehabilitation to Personal Use
- 27 February 2025
- Published by Springer Nature
- p. 199-202
From Clinic to Home: Transitioning Exoskeletons from Rehabilitation to Personal Use
- Open Access
- 1 November 2024
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 21 (1) , 1-24
Immersive virtual reality for learning exoskeleton-like virtual walking: a feasibility study
Purpose: Virtual Reality (VR) has proven to be an effective tool for motor (re)learning. Furthermore, with the current commercialization of low-cost head-mounted displays (HMDs), immersive virtual reality (IVR) has become a viable rehabilitation tool. Nonetheless, it is still an open question how immersive virtual environments should be designed to enhance motor learning, especially to support the learning of complex motor tasks. An example of such a complex task is triggering steps while wearing lower-limb exoskeletons as it requires the learning of several sub-tasks, e.g., shifting the weight from one leg to the other, keeping the trunk upright, and initiating steps. This study aims to find the necessary elements in VR to promote motor learning of complex virtual gait tasks. Methods: In this study, we developed an HMD-IVR-based system for training to control wearable lower-limb exoskeletons for people with sensorimotor disorders. The system simulates a virtual walking task of an avatar resembling the sub-tasks needed to trigger steps with an exoskeleton. We ran an experiment with forty healthy participants to investigate the effects of first- (1PP) vs. third-person perspective (3PP) and the provision (or not) of concurrent visual feedback of participants’ movements on the walking performance – namely number of steps, trunk inclination, and stride length –, as well as the effects on embodiment, usability, cybersickness, and perceived workload. Results: We found that all participants learned to execute the virtual walking task. However, no clear interaction of perspective and visual feedback improved the learning of all sub-tasks concurrently. Instead, the key seems to lie in selecting the appropriate perspective and visual feedback for each sub-task. Notably, participants embodied the avatar across all training modalities with low cybersickness levels. Still, participants’ cognitive load remained high, leading to marginally acceptable usability scores. Conclusions: Our findings suggest that to maximize learning, users should train sub-tasks sequentially using the most suitable combination of person’s perspective and visual feedback for each sub-task. This research offers valuable insights for future developments in IVR to support individuals with sensorimotor disorders in improving the learning of walking with wearable exoskeletons
- 1 November 2024
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 21 (1) , 1-24
Open AccessImmersive virtual reality for learning exoskeleton-like virtual walking: a feasibility study
Purpose: Virtual Reality (VR) has proven to be an effective tool for motor (re)learning. Furthermore, with the current commercialization of low-cost head-mounted displays (HMDs), immersive virtual reality (IVR) has become a viable rehabilitation tool. Nonetheless, it is still an open question how immersive virtual environments should be designed to enhance motor learning, especially to support the learning of complex motor tasks. An example of such a complex task is triggering steps while wearing lower-limb exoskeletons as it requires the learning of several sub-tasks, e.g., shifting the weight from one leg to the other, keeping the trunk upright, and initiating steps. This study aims to find the necessary elements in VR to promote motor learning of complex virtual gait tasks. Methods: In this study, we developed an HMD-IVR-based system for training to control wearable lower-limb exoskeletons for people with sensorimotor disorders. The system simulates a virtual walking task of an avatar resembling the sub-tasks needed to trigger steps with an exoskeleton. We ran an experiment with forty healthy participants to investigate the effects of first- (1PP) vs. third-person perspective (3PP) and the provision (or not) of concurrent visual feedback of participants’ movements on the walking performance – namely number of steps, trunk inclination, and stride length –, as well as the effects on embodiment, usability, cybersickness, and perceived workload. Results: We found that all participants learned to execute the virtual walking task. However, no clear interaction of perspective and visual feedback improved the learning of all sub-tasks concurrently. Instead, the key seems to lie in selecting the appropriate perspective and visual feedback for each sub-task. Notably, participants embodied the avatar across all training modalities with low cybersickness levels. Still, participants’ cognitive load remained high, leading to marginally acceptable usability scores. Conclusions: Our findings suggest that to maximize learning, users should train sub-tasks sequentially using the most suitable combination of person’s perspective and visual feedback for each sub-task. This research offers valuable insights for future developments in IVR to support individuals with sensorimotor disorders in improving the learning of walking with wearable exoskeletons
- 15 December 2023
- Published by Elsevier in Revista Española de Medicina Nuclear e Imagen Molecular
- Vol. 42, S153
CO010 - IMPACTO DE LA [18F]F-FLUOROCLINA PET/TC EN EL MANEJO Y PRONÓSTICO DEL CARCINOMA HEPATOCELULAR
- 15 December 2023
- Published by Elsevier in Revista Española de Medicina Nuclear e Imagen Molecular
- Vol. 42, S153
CO010 - IMPACTO DE LA [18F]F-FLUOROCLINA PET/TC EN EL MANEJO Y PRONÓSTICO DEL CARCINOMA HEPATOCELULAR
- Open Access
- 9 October 2023
- Published by Springer Nature in Research Square
First Steps Towards Facilitating the Learning of Using Wearable Lower-limb Exoskeletons withImmersive Virtual Reality
Purpose: Wearable lower-limb robotic exoskeletons have developed rapidly in recent years for the gait rehabilitation and ambulatory assistance of people with spinal cord injury (SCI). However, the learning process to use an exoskeleton is lengthy and tedious as it requires the learning of sequential sub-tasks to trigger steps, e.g., shifting the weight between legs and hip thrust. Timely, the emergence of exoskeletons has coincided with the commercialization of low-cost head-mounted displays (HMDs) that make immersive virtual reality (IVR) a viable rehabilitation tool. HMDs could be a valuable tool to promote the learning of using exoskeletons. However, it is still an open question how immersive virtual environments should be designed to enhance the learning of this especially complex motor task. Methods: In this study, we developed an HMD-IVR-based system for training to control wearable lower-limb exoskeletons. The system simulates a virtual walking task of an avatar resembling the sub-tasks needed to trigger steps with an exoskeleton. We ran an experiment with forty healthy participants to investigate the effects of first- (1PP) vs. third-person perspective (3PP) and the provision (or not) of concurrent visual feedback of participants' movements on the walking performance -- namely distance walked, trunk inclination, and stride length --, as well as the effects on embodiment, usability, cybersickness, and perceived workload. Results: We found that all participants learned to execute the walking task. However, no clear combination of perspective and visual feedback improved the learning of all sub-tasks concurrently. Instead, the key seems to lie in selecting the appropriate perspective and visual feedback for each sub-task. In particular, the 1PP improved the stride length while training with concurrent visual feedback did not enhance learning overall. Notably, participants embodied the avatar across all training modalities with low cybersickness levels. Still, participants' cognitive load remained high, leading to marginally acceptable usability scores. Conclusion: Our findings suggest that to maximize learning, patients should train sub-tasks sequentially using the most suitable combination of person's perspective and visual feedback for each sub-task. This research offers valuable insights for future developments in IVR to support individuals with SCI in improving the learning of walking with wearable exoskeletons.
- 9 October 2023
- Published by Springer Nature in Research Square
Open AccessFirst Steps Towards Facilitating the Learning of Using Wearable Lower-limb Exoskeletons withImmersive Virtual Reality
Purpose: Wearable lower-limb robotic exoskeletons have developed rapidly in recent years for the gait rehabilitation and ambulatory assistance of people with spinal cord injury (SCI). However, the learning process to use an exoskeleton is lengthy and tedious as it requires the learning of sequential sub-tasks to trigger steps, e.g., shifting the weight between legs and hip thrust. Timely, the emergence of exoskeletons has coincided with the commercialization of low-cost head-mounted displays (HMDs) that make immersive virtual reality (IVR) a viable rehabilitation tool. HMDs could be a valuable tool to promote the learning of using exoskeletons. However, it is still an open question how immersive virtual environments should be designed to enhance the learning of this especially complex motor task. Methods: In this study, we developed an HMD-IVR-based system for training to control wearable lower-limb exoskeletons. The system simulates a virtual walking task of an avatar resembling the sub-tasks needed to trigger steps with an exoskeleton. We ran an experiment with forty healthy participants to investigate the effects of first- (1PP) vs. third-person perspective (3PP) and the provision (or not) of concurrent visual feedback of participants' movements on the walking performance -- namely distance walked, trunk inclination, and stride length --, as well as the effects on embodiment, usability, cybersickness, and perceived workload. Results: We found that all participants learned to execute the walking task. However, no clear combination of perspective and visual feedback improved the learning of all sub-tasks concurrently. Instead, the key seems to lie in selecting the appropriate perspective and visual feedback for each sub-task. In particular, the 1PP improved the stride length while training with concurrent visual feedback did not enhance learning overall. Notably, participants embodied the avatar across all training modalities with low cybersickness levels. Still, participants' cognitive load remained high, leading to marginally acceptable usability scores. Conclusion: Our findings suggest that to maximize learning, patients should train sub-tasks sequentially using the most suitable combination of person's perspective and visual feedback for each sub-task. This research offers valuable insights for future developments in IVR to support individuals with SCI in improving the learning of walking with wearable exoskeletons.
- Open Access
Randomized, Crossover Clinical Trial on the Safety, Feasibility, and Usability of the ABLE Exoskeleton: A Comparative Study with Knee-Ankle-Foot Orthoses
Wearable exoskeletons are emerging as a new tool for gait training. However, comparisons between exoskeletons and conventional orthoses in terms of safety and feasibility are scarce. This study assessed the safety, feasibility, usability, and learning process of using the ABLE Exoskeleton in people with spinal cord injury (SCI) while comparing it with knee-ankle-foot orthoses (KAFOs). In this randomized, crossover clinical trial, 10 patients with chronic complete SCI (T4-T12) conducted a 10-session training and assessment protocol with each device: KAFOs and the ABLE Exoskeleton. Outcomes on safety (adverse events), and feasibility and usability (level of assistance, donning/doffing, therapy activities) were recorded for both devices. Evaluation sessions included standard clinical tests (Timed Up and Go, 10-Meter Walk Test, and 6-Minute Walk Test) to assess gait performance. The therapy metrics (number of steps, distance, gait speed, and standing and walking time) were recorded at each session for the robotic device. Participants quickly learned how to use the ABLE Exoskeleton, showing improvements in all therapy metrics (p < 0.05) and the 6-Minute Walk Test (p < 0.05). The robotic device reported less adverse events than KAFOs (17 and 31, respectively). Total donning and doffing time was 43 seconds faster with the robotic device using comparable levels of assistance. The time to complete the therapy activities was very similar between devices. Overall, participants needed 1 to 4 training sessions to perform essential therapy activities (sit/stand transitions, walking 10 meters, turning around) with both devices using minimum assistance or less. The results of this study show that it is feasible and safe for people with motor complete paraplegia due to SCI (T4-T12) to use the ABLE Exoskeleton for gait training in a rehabilitation hospital setting. The ABLE Exoskeleton proved to be safer than KAFOs in terms of adverse events, and as practical and easy to use as the conventional orthoses.
Open AccessRandomized, Crossover Clinical Trial on the Safety, Feasibility, and Usability of the ABLE Exoskeleton: A Comparative Study with Knee-Ankle-Foot Orthoses
Wearable exoskeletons are emerging as a new tool for gait training. However, comparisons between exoskeletons and conventional orthoses in terms of safety and feasibility are scarce. This study assessed the safety, feasibility, usability, and learning process of using the ABLE Exoskeleton in people with spinal cord injury (SCI) while comparing it with knee-ankle-foot orthoses (KAFOs). In this randomized, crossover clinical trial, 10 patients with chronic complete SCI (T4-T12) conducted a 10-session training and assessment protocol with each device: KAFOs and the ABLE Exoskeleton. Outcomes on safety (adverse events), and feasibility and usability (level of assistance, donning/doffing, therapy activities) were recorded for both devices. Evaluation sessions included standard clinical tests (Timed Up and Go, 10-Meter Walk Test, and 6-Minute Walk Test) to assess gait performance. The therapy metrics (number of steps, distance, gait speed, and standing and walking time) were recorded at each session for the robotic device. Participants quickly learned how to use the ABLE Exoskeleton, showing improvements in all therapy metrics (p < 0.05) and the 6-Minute Walk Test (p < 0.05). The robotic device reported less adverse events than KAFOs (17 and 31, respectively). Total donning and doffing time was 43 seconds faster with the robotic device using comparable levels of assistance. The time to complete the therapy activities was very similar between devices. Overall, participants needed 1 to 4 training sessions to perform essential therapy activities (sit/stand transitions, walking 10 meters, turning around) with both devices using minimum assistance or less. The results of this study show that it is feasible and safe for people with motor complete paraplegia due to SCI (T4-T12) to use the ABLE Exoskeleton for gait training in a rehabilitation hospital setting. The ABLE Exoskeleton proved to be safer than KAFOs in terms of adverse events, and as practical and easy to use as the conventional orthoses.
- Open Access
- 9 November 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-16
Comparing walking with knee-ankle-foot orthoses and a knee-powered exoskeleton after spinal cord injury: a randomized, crossover clinical trial
Recovering the ability to stand and walk independently can have numerous health benefits for people with spinal cord injury (SCI). Wearable exoskeletons are being considered as a promising alternative to conventional knee-ankle-foot orthoses (KAFOs) for gait training and assisting functional mobility. However, comparisons between these two types of devices in terms of gait biomechanics and energetics have been limited. Through a randomized, crossover clinical trial, this study compared the use of a knee-powered lower limb exoskeleton (the ABLE Exoskeleton) against passive orthoses, which are the current standard of care for verticalization and gait ambulation outside the clinical setting in people with SCI. Ten patients with SCI completed a 10-session gait training program with each device followed by user satisfaction questionnaires. Walking with the ABLE Exoskeleton improved gait kinematics compared to the KAFOs, providing a more physiological gait pattern with less compensatory movements (38% reduction of circumduction, 25% increase of step length, 29% improvement in weight shifting). However, participants did not exhibit significantly better results in walking performance for the standard clinical tests (Timed Up and Go, 10-m Walk Test, and 6-min Walk Test), nor significant reductions in energy consumption. These results suggest that providing powered assistance only on the knee joints is not enough to significantly reduce the energy consumption required by people with SCI to walk compared to passive orthoses. Active assistance on the hip or ankle joints seems necessary to achieve this outcome.
- 9 November 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-16
Open AccessComparing walking with knee-ankle-foot orthoses and a knee-powered exoskeleton after spinal cord injury: a randomized, crossover clinical trial
Recovering the ability to stand and walk independently can have numerous health benefits for people with spinal cord injury (SCI). Wearable exoskeletons are being considered as a promising alternative to conventional knee-ankle-foot orthoses (KAFOs) for gait training and assisting functional mobility. However, comparisons between these two types of devices in terms of gait biomechanics and energetics have been limited. Through a randomized, crossover clinical trial, this study compared the use of a knee-powered lower limb exoskeleton (the ABLE Exoskeleton) against passive orthoses, which are the current standard of care for verticalization and gait ambulation outside the clinical setting in people with SCI. Ten patients with SCI completed a 10-session gait training program with each device followed by user satisfaction questionnaires. Walking with the ABLE Exoskeleton improved gait kinematics compared to the KAFOs, providing a more physiological gait pattern with less compensatory movements (38% reduction of circumduction, 25% increase of step length, 29% improvement in weight shifting). However, participants did not exhibit significantly better results in walking performance for the standard clinical tests (Timed Up and Go, 10-m Walk Test, and 6-min Walk Test), nor significant reductions in energy consumption. These results suggest that providing powered assistance only on the knee joints is not enough to significantly reduce the energy consumption required by people with SCI to walk compared to passive orthoses. Active assistance on the hip or ankle joints seems necessary to achieve this outcome.