ZAZachi Itzhak Attia

Zachi Itzhak Attia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zachi Itzhak Attia has a total of 705 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Agentic AI-Generated vs. Clinician-Authored Hospital Course Narratives for Cardiology Hospitalizations: A Blinded Physician Evaluation

    by Eunjung Lee, David M. Harmon, Jason M. Holmes, Alexandra E. Allman, Stephanie A. Saey, Reid P. Schlesinger, Iuri Ferreira Felix, Paul A. Friedman, Zachi I. Attia

    Background: Discharge summaries are essential for safe transitions of care, but writing the hospital course narrative is time intensive. Large language models can generate plausible clinical narratives, yet prior approaches often rely on static inputs and remain vulnerable to omissions and factual inconsistencies. Methods: We developed an electronic health record (EHR)-integrated agentic artificial intelligence (AI) system that uses Gemini 2.5 Pro and Model Context Protocol tools to retrieve clinical notes, diagnostic reports, diagnoses, medications, and appointments on demand. In this retrospective, blinded, paired study, 50 inpatient cardiology encounters were randomly selected from admissions July 13 to 27, 2024, at Mayo Clinic, Rochester, Minnesota. Five physicians rated AI-generated and clinician-authored hospital course narratives for each encounter (250 ratings) on 0-to-10 scales for overall quality, clarity, completeness, accuracy, and readability and indicated a preference. The primary outcome was the paired difference in overall quality (linear mixed-effects model with crossed random intercepts for encounter and reviewer). Secondary domains were analyzed similarly with Bonferroni adjustment, and preference with a crossed random-effects logistic model. Results: Clinician-authored narratives were preferred in 132 ratings (52.8%) and AI-generated narratives in 118 (47.2%) (odds ratio for clinician-authored preference, 1.12; 95% CI, 0.71 to 1.78). Overall quality did not differ significantly (mean, 7.27 AI-generated versus 7.42 clinician-authored; difference, -0.15; 95% CI, -0.86 to 0.56; p=0.627). AI-generated narratives were rated higher for clarity (0.36; 95% CI, 0.07 to 0.65) and readability (0.72; 95% CI, 0.20 to 1.24) but lower for completeness (-0.84; 95% CI, -1.36 to -0.32) and accuracy (-0.35; 95% CI, -0.66 to -0.05). After Bonferroni correction, only lower completeness remained significant (adjusted p=0.012). Conclusions: Hospital course narratives generated by the EHR-integrated agentic AI system did not differ significantly from clinician-authored narratives in physician-rated overall quality or preference. Lower completeness supports continued clinician review before use in the medical record.

  • Left Ventricular Filling Pressure Classification by Electrocardiogram, Echocardiography, and Catheterization

    by Gal Tsaban, Eunjung Lee, Francisco Lopez-Jimenez, William R. Miranda, Garvan C. Kane, Horng H. Chen, Abhishek J. Deshmukh, Samuel J. Asirvatham, Peter A. Noseworthy, Rajiv Gulati, et al.


  • Open Access

    Serial Artificial Intelligence ECG-Derived Atrial Fibrillation Probability and Recurrence Risk After Pulsed Field Ablation

    by Mayank Sardana, Juan F. Rodriguez-Riascos, Hema S. Vemulapalli, James Kim, Zachi I. Attia, Julia Wood, Kathryn Mangold, Paul A. Friedman, Peter A. Noseworthy, Komandoor Srivathsan

    BACKGROUND: Pulsed field ablation is now widely used for atrial fibrillation (AF) ablation, but atrial tachyarrhythmia recurrence remains common and postablation risk tools are limited. We assessed whether a validated sinus‑rhythm artificial intelligence— enabled ECG AF probability score, and its early postablation change, predicts recurrence after pulsed field ablation. METHODS: We studied consecutive patients undergoing index pulsed field ablation across 3 Mayo Clinic sites (February 2024–March 2025) with ≥1 sinus‑rhythm ECG within 180 days preprocedure. Baseline artificial intelligence—enabled ECG AF score (range 0–1) was the mean across baseline ECGs. Recovery indices (RI30/60/90), defined as mean postprocedure artificial intelligence—enabled ECG score within days 1–30/60/90 minus baseline, predicted post‑blanking recurrence using corresponding 30‑, 60‑, and 90‑day blanking windows. The primary outcome was time to first documented AF/atrial flutter/atrial tachycardia episode >30 seconds, ascertained via clinic ECGs, ambulatory monitoring, and device interrogations. Cox regression adjusted for prespecified clinical and echocardiographic covariates assessed associations; Harrell C‑statistic quantified discrimination. RESULTS: Among 1052 patients (67±10 years; 33% women), median baseline score was 0.35; 320 (30%) recurred over 188 days. Higher baseline score independently predicted recurrence (hazard ratio per 0.1 increase, 1.08 [95% CI, 1.03–1.14]). Scores rose on day 0 after ablation, then declined over subsequent weeks, with persistently higher, less‑improving trajectories among patients who recurred (time×recurrence interaction P <0.001). Day 0 score was not independently associated with recurrence after adjustment. Attenuated early recovery (higher recovery index) was independently associated with recurrence, most robustly for RI-90 (hazard ratio per 0.1 increase, 1.15 [95% CI, 1.07–1.24]), and improved discrimination beyond baseline and covariates (C‑statistic, 0.63–0.67; ΔC=0.04). Findings were consistent in a historical thermal ablation cohort. CONCLUSIONS: Baseline and early postablation dynamics of a sinus‑rhythm artificial intelligence—enabled ECG AF probability score are associated with pulsed field ablation recurrence and may aid multivariable risk stratification; prospective validation is warranted.

  • Prognostic Value of Artificial Intelligence ECG–Derived Diastolic Function in Surgical Aortic Valve Replacement

    by Tedy Sawma, Hartzell V. Schaff, Sina Danesh, Arman Arghami, Eunjung Lee, Masoomeh Aslahishahri, John Stulak, Kevin Greason, Joseph A. Dearani, Francisco Lopez‐Jimenez, et al.

    Background: Diastolic dysfunction is common in patients with aortic stenosis and may influence outcomes following surgical aortic valve replacement. We aimed to examine the association of preoperative artificial intelligence (AI)‐generated diastolic function grades with early and late outcomes following aortic valve replacement and how postoperative progression influence prognosis. Methods: We identified 5503 patients undergoing aortic valve replacement between 2000 and 2023. Diastolic function was assessed using a validated deep‐learning AI model applied to 12‐lead ECGs done preoperatively and on postoperative follow‐up. Diastolic grades were classified by AI into Grades 1 to 3. Longitudinal trend analyses and multivariable regression models were used to assess study end points. Results: Among 5503 patients (mean age 72.4±10.8 years; 39% female), higher AI ECG diastolic grades were associated with greater comorbidity burden, including diabetes, renal disease, and heart failure. AI ECG diastolic Grade 3 was independently associated with higher in‐hospital mortality (odds ratio, 2.5; P =0.007) and other complications. At 5‐year follow‐up, patients with Grade 3 showed the least improvement in diastolic function by both ECG and echocardiography. Grades 2 and 3 diastolic function at baseline were independently associated with increased late mortality (hazard ratio, 1.3 and 2.45, respectively; both P <0.001). Additionally, lack of improvement in AI ECG diastolic grade by 1 year was also independently associated with late mortality. Conclusions: AI ECG–derived diastolic function grades strongly correlates with early complications and long‐term mortality and diastolic progression after aortic valve replacement. AI ECG provides a powerful, noninvasive tool for risk stratification and longitudinal monitoring of patients with aortic stenosis.

  • Open Access

    Validating ECG-Based Artificial Intelligence Models for Cardiomyopathy Detection in Obstetric Patients

    by Demilade Adedinsewo, Patrick W. Johnson, Carolina Morales-Lara, Maria Vitoria Coutinho, Sabrina D. Phillips, Marc A. Eidelhoch, Michal Cohen-Shelly, Elad Maor, Ariel Furer, Abraham Tsur, et al.

  • Metabolic and Bariatric Surgery and Change in the AI-ECG–Derived Biological-Age Gap: A Longitudinal Cohort Study

    by Reza Shahriarirad, Parvin Kalhor, Masoomeh Aslahishahri, Wissam Ghusn, Zachi Itzhak Attia, Nour El Ghazal, Omar Ghanem, Simon Laplante

  • Open Access

    AI-ECG for Detecting Left Ventricular Systolic Dysfunction in Chagas Disease

    by Clareci Silva Cardoso, Kathryn Mangold, José Luiz Padilha da Silva, Cláudia Di Lorenzo Oliveira, Ariela Mota Ferreira, Lea Campos Oliveira da Silva, Maria Do Carmo P. Nunes, Wanessa Campos Vinhal, Ana Carolina de Oliveira Gonçalves, Paulo Rodrigues Gomes, et al.

  • Open Access

    A view-flexible deep learning framework for automated analysis of 2D echocardiography

    by D. M. Anisuzzaman, Jeffrey G. Malins, John I. Jackson, Eunjung Lee, Jwan A. Naser, Behrouz Rostami, Jared G. Bird, Dan Spiegelstein, Talia Amar, Christie C. Ngo, et al.

    Echocardiography traditionally requires experienced operators to select and interpret clips from specific viewing angles. Clinical decision-making is therefore limited for handheld cardiac ultrasound (HCU), which is often collected by novice users. In this study, we developed a view-flexible deep learning framework to estimate left ventricular ejection fraction (LVEF), patient age, and patient sex from any of several views containing the left ventricle. Model performance was: (1) consistently strong across retrospective transthoracic echocardiography (TTE) datasets; (2) comparable between prospective HCU versus TTE (625 patients; LVEF r2 0.80 vs. 0.86, LVEF [> or ≤40%] AUC 0.981 vs. 0.993, age r2 0.85 vs. 0.87, sex classification AUC 0.985 vs. 0.996); (3) comparable between prospective HCU data collected by experts versus novice users (100 patients; LVEF r2 0.77 vs. 0.64, LVEF AUC 0.983 vs. 0.968). This approach may broaden the clinical utility of echocardiography by lessening the need for user expertise in image acquisition. Created in BioRender. Malins, J. (2026) https://BioRender.com/lhw4pb1 .


  • Open Access

    Echocardiography-Based, Artificial Intelligence-Enabled Electrocardiography (AI-ECG) for Diastolic Hemodynamics Phenotyping in Acute Heart Failure (AHF)

    by Yee Weng Wong, Muhannad A. Abbasi, Eunjung Lee, Gal Tsaban, Zachi Attia, Paul A. Friedman, Peter A. Noseworthy, Francisco Lopez-Jimenez, Horng H. Chen, Grace Lin, et al.

    Background: Acute heart failure (AHF) exhibits marked heterogeneity in diastolic hemodynamics, yet comprehensive echocardiographic assessment of diastolic function (DF) and filling pressure (FP) is often infeasible. We evaluated whether artificial intelligence–enabled electrocardiography (AI-ECG) could provide scalable DF grading and FP estimation in hospitalized AHF patients. Methods: We retrospectively studied adults hospitalized for AHF across Mayo Clinic sites (2013–2023) who received ≥1 dose of intravenous loop diuretic and had paired 12-lead ECG and TTE. The previously validated AI-ECG DF model was applied without retraining to generate four DF grades and a continuous FP probability. Clinical outcomes were all-cause mortality and heart failure rehospitalization. Associations with clinical severity markers and echocardiographic indices were examined. Kaplan–Meier survival analysis and adjusted multivariable Cox proportional hazards models were performed. Exploratory analyses examine the kinetics of change in FP probability and impact on mortality. Results: Among 11,513 patients (median age 75 years, 39% female), AI-ECG DF grading was feasible in 100%, whereas echocardiographic DF was indeterminate in 44% of clinically eligible patients. In 2,582 patients with determinate echocardiographic DF, AI-ECG FP probability discriminated TTE Grade 2–3 dysfunction with AUC 0.85 (95% CI 0.83 – 0.86). Higher AI-ECG DF grades were associated with higher comorbidity burden, worse NYHA class, elevated NT-proBNP, higher MAGGIC scores, elevated PCWP, and more advanced structural remodeling. After multivariable adjustment, AI-ECG DF remained independently associated with mortality (hazard ratio [HR] 1.25, 95% CI 1.16–1.35 for Grade 2; HR 1.44, 95% CI 1.33–1.56 for Grade 3 versus Normal/Grade 1). Combining AI-ECG DF with MAGGIC scores yielded ordered risk gradients, with highest mortality in patients with both high MAGGIC and Grade 2–3 DF. Among patients with serial ECGs, improvement in FP probability was independently associated with lower mortality (HR 0.85, 95% CI 0.79–0.91), whereas worsening did not show a consistent adverse gradient beyond baseline DF. Conclusions: In a large, geographically diverse AHF cohort, AI-ECG DF grading was universally feasible, correlated with established hemodynamic severity markers, and provided independent prognostic information beyond established risk factors, supporting its role as a pragmatic, scalable diastolic biomarker in AHF. CLINICAL PERSPECTIVE: What Is New?: In 11,513 hospitalized acute heart failure (HF) patients, artificial intelligence-enabled electrocardiography provided diastolic function grading in 100% of patients from a single 12-lead ECG without requiring additional clinical variables, compared with 56% feasibility for guideline-based echocardiography grading. AI-ECG diastolic function grades correlated with established marker of severity (NYHA functional class, NT-proBNP, MAGGIC risk scores, and pulmonary capillary wedge pressure) and remained independently associated with both mortality and HF rehospitalization after multivariable adjustment. Serial AI-ECG measurements identified post-discharge filling pressure trajectories, with improvement independently associated with 15% lower mortality, a first demonstration that longitudinal ECG assessment can track post-discharge hemodynamic recovery. What Are the Clinical Implications?: AI-ECG transforms the universally obtained 12-lead ECG into an actionable hemodynamic biomarker that addresses the critical gap when echocardiographic diastolic function assessment is indeterminate or unavailable in acute HF patients. Despite markedly different hemodynamic severity and long-term outcomes across AI-ECG diastolic function grades, hospitalization length of stay did not differ, suggesting advanced diastolic dysfunction represents occult risk not easily recognized during routine acute care and highlighting the need for improved post-discharge risk stratification. The continuous filling pressure probability metric enables longitudinal monitoring of post-discharge hemodynamic status using serial routine ECGs, potentially identifying patients requiring intensified follow-up or specialist referral.

  • Open Access

    Author Correction: Detection of undiagnosed liver cirrhosis via AI-enabled electrocardiogram: a pragmatic, cluster-randomized clinical trial

    by Douglas A. Simonetto, David Rushlow, Kan Liu, Alberto Calleri, Blake A. Kassmeyer, Ryan J. Lennon, Puru Rattan, Matthew E. Bernard, Gagandeep Singh, Mark E. Deyo-Svendsen, et al.