Xianfeng Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xianfeng Yang has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Qing Jiang
State Key Laboratory of Pharmaceutical Biotechnology, Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China
4 shared publications - Xingsong Wang
School of Mechanical Engineering, Southeast University, Nanjing, China
4 shared publications - Longfei Yang
School of Mechanical Engineering, Southeast University, Nanjing, China
3 shared publications Fang Zhou
Xinxiang Central Hospital, China
2 shared publicationsGuoqian Zhao
Danyang Hospital of Traditional Chinese Medicine, China
2 shared publicationsHuifen Wang
The Second People's Hospital of Xuanwei, China
2 shared publications
Latest Publications
- 3 July 2025
- Published by SAGE Publications in Acta Radiologica
Feasibility study of T2 mapping and fat analysis and calculation technique in the evaluation of thigh quadriceps before and after countermovement jump
Background: The application of quantitative magnetic resonance imaging (MRI) in skeletal muscle is crucial in rehabilitation medicine and competitive sports training. Purpose: To explore the feasibility of evaluating T2 value, proton density fat fraction (PDFF), and cross-sectional area (CSA) of the quadriceps femoris before and after countermovement jump (CMJ) based on T2 mapping and Fat Analysis and Calculation Technique (FACT). Material and Methods: A total of 32 healthy volunteers were recruited and underwent MRI examination of the thigh muscles, including axial T2 mapping and FACT sequence. The T2 value, PDFF, and CSA of the quadriceps femoris, adductor magnus, and gracilis were measured. The peak torque (PT) of the quadriceps femoris was measured using an isokinetic muscle strength system. The differences in MRI parameters before and after CMJ were compared, as well as the differences between sexes. Results: The T2 value and CSA of the quadriceps femoris and adductor magnus increased and PDFF decreased after CMJ ( P P P P <0.001). Conclusion: T2 mapping and FACT can quantitatively evaluate the differences of T2 value, PDFF, and CSA of different muscles before and after CMJ, which is an important evaluation method for competitive sports training and disease rehabilitation.
- 3 July 2025
- Published by SAGE Publications in Acta Radiologica
Feasibility study of T2 mapping and fat analysis and calculation technique in the evaluation of thigh quadriceps before and after countermovement jump
Background: The application of quantitative magnetic resonance imaging (MRI) in skeletal muscle is crucial in rehabilitation medicine and competitive sports training. Purpose: To explore the feasibility of evaluating T2 value, proton density fat fraction (PDFF), and cross-sectional area (CSA) of the quadriceps femoris before and after countermovement jump (CMJ) based on T2 mapping and Fat Analysis and Calculation Technique (FACT). Material and Methods: A total of 32 healthy volunteers were recruited and underwent MRI examination of the thigh muscles, including axial T2 mapping and FACT sequence. The T2 value, PDFF, and CSA of the quadriceps femoris, adductor magnus, and gracilis were measured. The peak torque (PT) of the quadriceps femoris was measured using an isokinetic muscle strength system. The differences in MRI parameters before and after CMJ were compared, as well as the differences between sexes. Results: The T2 value and CSA of the quadriceps femoris and adductor magnus increased and PDFF decreased after CMJ ( P P P P <0.001). Conclusion: T2 mapping and FACT can quantitatively evaluate the differences of T2 value, PDFF, and CSA of different muscles before and after CMJ, which is an important evaluation method for competitive sports training and disease rehabilitation.
- Open Access
- 26 June 2022
- Published by Elsevier in Journal of Orthopaedic Translation
- Vol. 34, 91-101
Identification and diagnosis of meniscus tear by magnetic resonance imaging using a deep learning model
- 26 June 2022
- Published by Elsevier in Journal of Orthopaedic Translation
- Vol. 34, 91-101
Open AccessIdentification and diagnosis of meniscus tear by magnetic resonance imaging using a deep learning model
- Open Access
The rapid identification and diagnosis of meniscus tear by Magnetic Resonance Imaging using a deep learning model
Objective The meniscus tear is a common problem in sports trauma. The imaging diagnosis mainly depends on the MRI. To improve the diagnostic accuracy and efficiency, a deep learning model was employed in this study and the identification efficiency has been evaluated. Methods The standard knee MRI images of 924 individual patients were used to complete the training, validation, and testing process. The Mask R-CNN was considered as the deep learning network structure, and the ResNet50 was considered as the backbone network. The deep learning model was trained and validated with a dataset containing 504 and 220 patients, respectively. The accuracy testing was performed on a dataset of 200 patients and reviewed by an experienced radiologist and a sports medicine physician. Results After training and validation, the deep learning model effectively recognized the healthy and injured meniscus. The overall average precision of the bounding box and pixel mask was more than 88% when the IoU threshold value was 0.75. The detailed average precision of three types of menisci (healthy, torn, and degenerated) was ranged from 68% to 80%. The overall sensitivity of the bounding box and pixel mask was more than 74% at the IoU threshold from 0.50 to 0.95. The diagnosis accuracy for the healthy, torn, and degenerated meniscus was 87.50%, 86.96%, and 84.78%, respectively. Conclusion The Mask R-CNN recognized effectively and predicted the meniscus injury, especially for the tears that occurred at different parts of the meniscus. The recognition accuracy was admirable. The diagnostic accuracy can be further improved with the increase of the training sample size. Therefore, this tool has great potential in the application for the diagnosis of meniscus injury. The translational potential of this article Deep learning model has unique effect in reducing doctors’ workload and improving diagnosis accuracy. It can identify and classify injured and healthy meniscus more accurately after training and learning datasets. The torn and degenerated meniscus can also be distinguished by this model. This technology could serve as an effective tool for clinical MRI-assisted diagnostics in meniscus injury.
Open AccessThe rapid identification and diagnosis of meniscus tear by Magnetic Resonance Imaging using a deep learning model
Objective The meniscus tear is a common problem in sports trauma. The imaging diagnosis mainly depends on the MRI. To improve the diagnostic accuracy and efficiency, a deep learning model was employed in this study and the identification efficiency has been evaluated. Methods The standard knee MRI images of 924 individual patients were used to complete the training, validation, and testing process. The Mask R-CNN was considered as the deep learning network structure, and the ResNet50 was considered as the backbone network. The deep learning model was trained and validated with a dataset containing 504 and 220 patients, respectively. The accuracy testing was performed on a dataset of 200 patients and reviewed by an experienced radiologist and a sports medicine physician. Results After training and validation, the deep learning model effectively recognized the healthy and injured meniscus. The overall average precision of the bounding box and pixel mask was more than 88% when the IoU threshold value was 0.75. The detailed average precision of three types of menisci (healthy, torn, and degenerated) was ranged from 68% to 80%. The overall sensitivity of the bounding box and pixel mask was more than 74% at the IoU threshold from 0.50 to 0.95. The diagnosis accuracy for the healthy, torn, and degenerated meniscus was 87.50%, 86.96%, and 84.78%, respectively. Conclusion The Mask R-CNN recognized effectively and predicted the meniscus injury, especially for the tears that occurred at different parts of the meniscus. The recognition accuracy was admirable. The diagnostic accuracy can be further improved with the increase of the training sample size. Therefore, this tool has great potential in the application for the diagnosis of meniscus injury. The translational potential of this article Deep learning model has unique effect in reducing doctors’ workload and improving diagnosis accuracy. It can identify and classify injured and healthy meniscus more accurately after training and learning datasets. The torn and degenerated meniscus can also be distinguished by this model. This technology could serve as an effective tool for clinical MRI-assisted diagnostics in meniscus injury.
- Open Access
- 1 February 2021
- Published by AME Publishing Company in Annals of Palliative Medicine
- Vol. 10 (2) , 1950-1960
Self-compassion mediates the perfectionism and depression link on Chinese undergraduates
Self-compassion mediates the perfectionism and depression link on Chinese undergraduates Shujuan Wei, Lan Li, Jianping Shi, Huixin Liang, Xianfeng Yang
- 1 February 2021
- Published by AME Publishing Company in Annals of Palliative Medicine
- Vol. 10 (2) , 1950-1960
Open AccessSelf-compassion mediates the perfectionism and depression link on Chinese undergraduates
Self-compassion mediates the perfectionism and depression link on Chinese undergraduates Shujuan Wei, Lan Li, Jianping Shi, Huixin Liang, Xianfeng Yang
- Open Access
- 11 May 2020
- Published by Global Clinical Engineering Journal in Global Clinical Engineering Journal
- Vol. 2 (3) , 15-23
Semi-automatic 3-D Reconstruction Measurement of Muscle Volume with Magnetic Resonance Imaging
Background and Objective: We aimed to assess and verify the measurement accuracy and feasibility of semi-automatic magnetic resonance imaging (MRI) volume of interest (VOI) method by comparing its measurements with actual skeletal muscle volumes and discuss the clinical significance. Material and Methods: A total of 18 muscles from 2 pigs were measured by drainage method, VOI method (VVOI), the summation method (Vsum), and maximum section method (Vmax) respectively after MRI scanning. All measurements were performed by 2 musculoskeletal radiologists and repeated at 6 different times, recording the consuming time (minutes) of every muscle. The average result of the 2 radiologists was adopted. Results: The 3-D structure of the skeletal muscles was distinct and vivid. A Friedman test and the inter-class correlation coefficient (ICC) indicated the VOI method had a high intra- and inter-reliability. The root mean square error (RMSE) over 6 time-points was 1.101 mL. A Bland-Altman plot represented a superior consistency. Pairwise Mann–Whitney U testing demonstrated that the consuming time to measure each muscle by VOI method was short. Conclusions: The VOI method could semi-automatically display the 3-D reconstruct of the skeletal muscle clearly, conveniently, with a great accuracy, and high repeatability.
- 11 May 2020
- Published by Global Clinical Engineering Journal in Global Clinical Engineering Journal
- Vol. 2 (3) , 15-23
Open AccessSemi-automatic 3-D Reconstruction Measurement of Muscle Volume with Magnetic Resonance Imaging
Background and Objective: We aimed to assess and verify the measurement accuracy and feasibility of semi-automatic magnetic resonance imaging (MRI) volume of interest (VOI) method by comparing its measurements with actual skeletal muscle volumes and discuss the clinical significance. Material and Methods: A total of 18 muscles from 2 pigs were measured by drainage method, VOI method (VVOI), the summation method (Vsum), and maximum section method (Vmax) respectively after MRI scanning. All measurements were performed by 2 musculoskeletal radiologists and repeated at 6 different times, recording the consuming time (minutes) of every muscle. The average result of the 2 radiologists was adopted. Results: The 3-D structure of the skeletal muscles was distinct and vivid. A Friedman test and the inter-class correlation coefficient (ICC) indicated the VOI method had a high intra- and inter-reliability. The root mean square error (RMSE) over 6 time-points was 1.101 mL. A Bland-Altman plot represented a superior consistency. Pairwise Mann–Whitney U testing demonstrated that the consuming time to measure each muscle by VOI method was short. Conclusions: The VOI method could semi-automatically display the 3-D reconstruct of the skeletal muscle clearly, conveniently, with a great accuracy, and high repeatability.
- Open Access
- 25 July 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 1-12
The biomechanical changes of load distribution with longitudinal tears of meniscal horns on knee joint: a finite element analysis
Meniscal horns are important structures of meniscus, and longitudinal tears of these places could significantly change the load distribution among the knee joint. Few studies concerned the stress concentrated on bones, which may induce the osteonecrosis of subchondral bone. The goal of this study was to construct a finite element (FE) model with high fidelity of the knee joint and evaluate the biomechanical changes of load distribution of components after longitudinal tears of the horns of meniscus. Computed tomography and magnetic resonance images were used to develop the FE model, and two different kinds of simulations, the vertical and the anterior load, mimicking the static stance and slight flexion simulations, were applied after longitudinal tears of the horns of meniscus. Significantly elevated peak compressive and shear stress was observed on the menisci, cartilages, and subchondral bones, and enlarged meniscus extrusion was noticed. Between all the four types of longitudinal tears investigated in this study, longitudinal tears at the posterior horn of the medial meniscus were found to be the most significant. These findings showed that longitudinal tears of the meniscal horns lead to increased magnitude and changed distribution of stress and indicated the important role of posterior horn of medial meniscus. This may contribute to the mechanism between meniscal tears and spontaneous subchondral bone osteonecrosis.
- 25 July 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 1-12
Open AccessThe biomechanical changes of load distribution with longitudinal tears of meniscal horns on knee joint: a finite element analysis
Meniscal horns are important structures of meniscus, and longitudinal tears of these places could significantly change the load distribution among the knee joint. Few studies concerned the stress concentrated on bones, which may induce the osteonecrosis of subchondral bone. The goal of this study was to construct a finite element (FE) model with high fidelity of the knee joint and evaluate the biomechanical changes of load distribution of components after longitudinal tears of the horns of meniscus. Computed tomography and magnetic resonance images were used to develop the FE model, and two different kinds of simulations, the vertical and the anterior load, mimicking the static stance and slight flexion simulations, were applied after longitudinal tears of the horns of meniscus. Significantly elevated peak compressive and shear stress was observed on the menisci, cartilages, and subchondral bones, and enlarged meniscus extrusion was noticed. Between all the four types of longitudinal tears investigated in this study, longitudinal tears at the posterior horn of the medial meniscus were found to be the most significant. These findings showed that longitudinal tears of the meniscal horns lead to increased magnitude and changed distribution of stress and indicated the important role of posterior horn of medial meniscus. This may contribute to the mechanism between meniscal tears and spontaneous subchondral bone osteonecrosis.
- Open Access
- 1 July 2019
- Published by Elsevier in Journal of Orthopaedic Translation
- Vol. 18, 20-31
Effect of degenerative and radial tears of the meniscus and resultant meniscectomy on the knee joint: a finite element analysis
- 1 July 2019
- Published by Elsevier in Journal of Orthopaedic Translation
- Vol. 18, 20-31
Open AccessEffect of degenerative and radial tears of the meniscus and resultant meniscectomy on the knee joint: a finite element analysis
- 1 October 2018
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 6 (20) , 404
The effectiveness of allogeneic mesenchymal stem cells therapy for knee osteoarthritis in pigs
Background: Intraarticular injection of the mesenchymal stem cells (MSCs) has shown to be successful for treating osteoarthritis (OA). Nevertheless, many studies have been focusing on autologous MSCs. The following study investigates the safety and effectiveness of intraarticular injection of allogenic MSCs in a pig OA model. Methods: Superparamagnetic iron oxide (SPIO) nanoparticles were labelled with bone marrow-derived mesenchymal stem cells (BM-MSCs) to allow cells tracking using magnetic resonance imaging (MRI). A pig OA model was established by bilateral medial meniscectomy. Next, SPIO-BM-MSCs were injected into the right knee, while the left knee was left untreated. MRI and radiography were used to assess the degree of OA and to evaluate the effectiveness of allogenic MSCs. Hematoxylin and eosin (H&E), safranin-o fast green staining, toluidine blue, and immunohistochemical staining were used to evaluate the therapeutic effect of the injections. Results: At concentration of ≤20 µg/mL, SPIO caused no toxicity to BM-MSCs. Four weeks after surgery, OA changes were observed on MRI scan. The SPIO labeled BM-MSCs were found moving towards the impaired part of the cartilage 8 to 24 h after injections. In addition, no significant differences between the right side (therapeutic side) and the left side (untreated side) were observed following histological and immunohistochemistry analysis. Conclusions: The suitable concentration of SPIO for labelling BMSCs was 20 µg/mL, while the allogenic MSCs could move towards and accumulate around the impaired cartilage. No significant difference was found between treatment and control group.
- 1 October 2018
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 6 (20) , 404
The effectiveness of allogeneic mesenchymal stem cells therapy for knee osteoarthritis in pigs
Background: Intraarticular injection of the mesenchymal stem cells (MSCs) has shown to be successful for treating osteoarthritis (OA). Nevertheless, many studies have been focusing on autologous MSCs. The following study investigates the safety and effectiveness of intraarticular injection of allogenic MSCs in a pig OA model. Methods: Superparamagnetic iron oxide (SPIO) nanoparticles were labelled with bone marrow-derived mesenchymal stem cells (BM-MSCs) to allow cells tracking using magnetic resonance imaging (MRI). A pig OA model was established by bilateral medial meniscectomy. Next, SPIO-BM-MSCs were injected into the right knee, while the left knee was left untreated. MRI and radiography were used to assess the degree of OA and to evaluate the effectiveness of allogenic MSCs. Hematoxylin and eosin (H&E), safranin-o fast green staining, toluidine blue, and immunohistochemical staining were used to evaluate the therapeutic effect of the injections. Results: At concentration of ≤20 µg/mL, SPIO caused no toxicity to BM-MSCs. Four weeks after surgery, OA changes were observed on MRI scan. The SPIO labeled BM-MSCs were found moving towards the impaired part of the cartilage 8 to 24 h after injections. In addition, no significant differences between the right side (therapeutic side) and the left side (untreated side) were observed following histological and immunohistochemistry analysis. Conclusions: The suitable concentration of SPIO for labelling BMSCs was 20 µg/mL, while the allogenic MSCs could move towards and accumulate around the impaired cartilage. No significant difference was found between treatment and control group.
- Open Access
- 18 June 2018
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 16 (1) , 167
3D printing individualized heel cup for improving the self-reported pain of plantar fasciitis
To explore the therapeutic effect and the biomechanical mechanism of 3D printing individualized heel cup in treating of plantar heel pain. The clinical effect was evaluated by plantar pressure analysis and pain assessment in participants. Its biomechanical mechanism of protecting the plantar heel was explored using finite element simulation. The individualized heel cup could support and protect the osseous structure and soft tissue of plantar heel while walking and jogging, as well as significantly reduce the self-reported pain after being worn for 4 weeks. The nylon heel cup could alter the load concentration of the heel as well as decrease the load affected on plantar fascia and calcaneus bone. It also provided an obvious support for heel pad. To summarize, the 3D printed individualized heel cup can be used as an effective method for the treatment of plantar heel pain.
- 18 June 2018
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 16 (1) , 167
Open Access3D printing individualized heel cup for improving the self-reported pain of plantar fasciitis
To explore the therapeutic effect and the biomechanical mechanism of 3D printing individualized heel cup in treating of plantar heel pain. The clinical effect was evaluated by plantar pressure analysis and pain assessment in participants. Its biomechanical mechanism of protecting the plantar heel was explored using finite element simulation. The individualized heel cup could support and protect the osseous structure and soft tissue of plantar heel while walking and jogging, as well as significantly reduce the self-reported pain after being worn for 4 weeks. The nylon heel cup could alter the load concentration of the heel as well as decrease the load affected on plantar fascia and calcaneus bone. It also provided an obvious support for heel pad. To summarize, the 3D printed individualized heel cup can be used as an effective method for the treatment of plantar heel pain.