Hideo Matsuura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hideo Matsuura has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Toshio Fukuda
Nagoya University
4 shared publications - Daisuke Kobayashi
Kyoto University Health Service, Yoshida-Honmachi, Sakyo-ku, Kyoto 606-8501, Japan
2 shared publications - Fumihito Arai
The University of Tokyo
2 shared publications K. Shimojima
Dept. of Micro Syst. Eng., Nagoya Univ., Japan
2 shared publications- Keiichi Matsuzaki
Department of Public Health, Kitasato University School of Medicine, Sagamihara, Japan
2 shared publications - Keiichi Yamamoto
Information Technology Center, Wakayama Medical University, Wakayama, Japan
2 shared publications
Latest Publications
- Open Access
- 6 July 2020
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 8 (7) , e19902
Health Observation App for COVID-19 Symptom Tracking Integrated With Personal Health Records: Proof of Concept and Practical Use Study
Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.
- 6 July 2020
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 8 (7) , e19902
Open AccessHealth Observation App for COVID-19 Symptom Tracking Integrated With Personal Health Records: Proof of Concept and Practical Use Study
Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.
- Open Access
- 14 May 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Health Observation App for COVID-19 Symptom Tracking Integrated With Personal Health Records: Proof of Concept and Practical Use Study (Preprint)
BACKGROUND As a counter-cluster measure to prevent the spread of the infectious novel coronavirus disease (COVID-19), an efficient system for health observation outside the hospital is urgently required. Personal health records (PHRs) are suitable for the daily management of physical conditions. Importantly, there are no major differences between the items collected by daily health observation via PHR and the observation of items related to COVID-19. Until now, observations related to COVID-19 have been performed exclusively based on disease-specific items. Therefore, we hypothesize that PHRs would be suitable as a symptom-tracking tool for COVID-19. To this end, we integrated health observation items specific to COVID-19 with an existing PHR-based app. OBJECTIVE This study is conducted as a proof-of-concept study in a real-world setting to develop a PHR-based COVID-19 symptom-tracking app and to demonstrate the practical use of health observations for COVID-19 using a smartphone or tablet app integrated with PHRs. METHODS We applied the PHR-based health observation app within an active epidemiological investigation conducted by Wakayama City Public Health Center. At the public health center, a list is made of individuals who have been in close contact with known infected cases (health observers). Email addresses are used by the app when a health observer sends data to the public health center. Each health observer downloads the app and installs it on their smartphone. Self-observed health data are entered daily into the app. These data are then sent via the app by email at a designated time. Localized epidemiological officers can visualize the collected data using a spreadsheet macro and, thus, monitor the health condition of all health observers. RESULTS We used the app as part of an active epidemiological investigation executed at a public health center. During the investigation, 72 close contacts were discovered. Among them, 57 had adopted the use of the health observation app. Before the introduction of the app, all health observers would have been interviewed by telephone, a slow process that took four epidemiological officers more than 2 hours. After the introduction of the app, a single epidemiological officer can carry out health observations. The app was distributed for free beginning in early March, and by mid-May, it had been used by more than 20,280 users and 400 facilities and organizations across Japan. Currently, health observation of COVID-19 is socially recognized and has become one of the requirements for resuming social activities. CONCLUSIONS Health observation by PHRs for the purpose of improving health management can also be effectively applied as a measure against large-scale infectious diseases. Individual habits of improving awareness of personal health and the use of PHRs for daily health management are powerful armaments against the rapid spread of infectious diseases. Ultimately, similar actions may help to prevent the spread of COVID-19.
- 14 May 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessHealth Observation App for COVID-19 Symptom Tracking Integrated With Personal Health Records: Proof of Concept and Practical Use Study (Preprint)
BACKGROUND As a counter-cluster measure to prevent the spread of the infectious novel coronavirus disease (COVID-19), an efficient system for health observation outside the hospital is urgently required. Personal health records (PHRs) are suitable for the daily management of physical conditions. Importantly, there are no major differences between the items collected by daily health observation via PHR and the observation of items related to COVID-19. Until now, observations related to COVID-19 have been performed exclusively based on disease-specific items. Therefore, we hypothesize that PHRs would be suitable as a symptom-tracking tool for COVID-19. To this end, we integrated health observation items specific to COVID-19 with an existing PHR-based app. OBJECTIVE This study is conducted as a proof-of-concept study in a real-world setting to develop a PHR-based COVID-19 symptom-tracking app and to demonstrate the practical use of health observations for COVID-19 using a smartphone or tablet app integrated with PHRs. METHODS We applied the PHR-based health observation app within an active epidemiological investigation conducted by Wakayama City Public Health Center. At the public health center, a list is made of individuals who have been in close contact with known infected cases (health observers). Email addresses are used by the app when a health observer sends data to the public health center. Each health observer downloads the app and installs it on their smartphone. Self-observed health data are entered daily into the app. These data are then sent via the app by email at a designated time. Localized epidemiological officers can visualize the collected data using a spreadsheet macro and, thus, monitor the health condition of all health observers. RESULTS We used the app as part of an active epidemiological investigation executed at a public health center. During the investigation, 72 close contacts were discovered. Among them, 57 had adopted the use of the health observation app. Before the introduction of the app, all health observers would have been interviewed by telephone, a slow process that took four epidemiological officers more than 2 hours. After the introduction of the app, a single epidemiological officer can carry out health observations. The app was distributed for free beginning in early March, and by mid-May, it had been used by more than 20,280 users and 400 facilities and organizations across Japan. Currently, health observation of COVID-19 is socially recognized and has become one of the requirements for resuming social activities. CONCLUSIONS Health observation by PHRs for the purpose of improving health management can also be effectively applied as a measure against large-scale infectious diseases. Individual habits of improving awareness of personal health and the use of PHRs for daily health management are powerful armaments against the rapid spread of infectious diseases. Ultimately, similar actions may help to prevent the spread of COVID-19.
- Open Access
- 1 January 1997
- Published by Japanese Circulation Society in Japanese Circulation Journal
- Vol. 61 (12) , 1015-1020
Effects of Volume Loading on Pulmonary Venous Flow and its Relation to Left Atrial Functions
Although pulmonary venous (PV) flow is closely related to left atrial (LA) pressure dynamics, few investigators have discussed it in relation to LA functions, ie, reservoir, conduit, and booster pump functions. We examined changes in PV flow rate, LA dimension, and left ventricular filling volume in 11 dogs, and assessed the effects of multistaged volume loading on PV flow and LA functions. Systolic PV flow rate (S) increased significantly and reached a plateau, reflecting a limited LA reservoir function. Diastolic PV flow rate (D) increased significantly with an increase in LA pressure. S/D ratio increased non-significantly from 0.87±0.07 before volume loading to 0.96±0.08 until S reached a plateau and then decreased to 0.76±0.08 (pJpn Circ J 1997; 61: 1015 - 1020)
- 1 January 1997
- Published by Japanese Circulation Society in Japanese Circulation Journal
- Vol. 61 (12) , 1015-1020
Open AccessEffects of Volume Loading on Pulmonary Venous Flow and its Relation to Left Atrial Functions
Although pulmonary venous (PV) flow is closely related to left atrial (LA) pressure dynamics, few investigators have discussed it in relation to LA functions, ie, reservoir, conduit, and booster pump functions. We examined changes in PV flow rate, LA dimension, and left ventricular filling volume in 11 dogs, and assessed the effects of multistaged volume loading on PV flow and LA functions. Systolic PV flow rate (S) increased significantly and reached a plateau, reflecting a limited LA reservoir function. Diastolic PV flow rate (D) increased significantly with an increase in LA pressure. S/D ratio increased non-significantly from 0.87±0.07 before volume loading to 0.96±0.08 until S reached a plateau and then decreased to 0.76±0.08 (pJpn Circ J 1997; 61: 1015 - 1020)
- 1 January 1996
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 79-85
Distributed virtual environment for intravascular tele-surgery using multimedia telecommunication
The number of specialized medical doctors is decreasing. It is important to assist doctors in their operation of surgical tools. To solve this problem, we propose a distributed VR system using multimedia telecommunication for training, diagnosis, and assistance in surgery. To realize this system, it is important to exchange high quality moving pictures. We use high speed optical fiber network with ATM (Asynchronous Transfer Mode). ATM has excellent features such as bandwidth allocation which is suitable for multimedia communication on computer networks. Based on this new information infrastructure we built a prototype telesurgery system for intravascular neurosurgery. We made a virtual simulator for the operation of a catheter, that is designed for minimum invasive surgery inside complex and narrow brain blood vessels. A force display and visual assistance method are proposed to assist the doctor. We undertook teleoperation experiments between Nagoya and Tokyo, about 350 km away each other, using high speed optical fiber network, and evaluated the effectiveness of the proposed system.
- 1 January 1996
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 79-85
Distributed virtual environment for intravascular tele-surgery using multimedia telecommunication
The number of specialized medical doctors is decreasing. It is important to assist doctors in their operation of surgical tools. To solve this problem, we propose a distributed VR system using multimedia telecommunication for training, diagnosis, and assistance in surgery. To realize this system, it is important to exchange high quality moving pictures. We use high speed optical fiber network with ATM (Asynchronous Transfer Mode). ATM has excellent features such as bandwidth allocation which is suitable for multimedia communication on computer networks. Based on this new information infrastructure we built a prototype telesurgery system for intravascular neurosurgery. We made a virtual simulator for the operation of a catheter, that is designed for minimum invasive surgery inside complex and narrow brain blood vessels. A force display and visual assistance method are proposed to assist the doctor. We undertook teleoperation experiments between Nagoya and Tokyo, about 350 km away each other, using high speed optical fiber network, and evaluated the effectiveness of the proposed system.
- 1 July 1993
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 26 (2) , 761-764
Sensor Integration System Based on Fuzzy Inference with Vision System and LED Displacement Sensor
- 1 July 1993
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 26 (2) , 761-764
Sensor Integration System Based on Fuzzy Inference with Vision System and LED Displacement Sensor
- Open Access
- 1 January 1992
- Published by Japan Society of Mechanical Engineers in TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C
- Vol. 58 (552) , 2483-2488
Structure and Mechanism of Microcapsule Pump Using Osmotic Pressure Actuator.
We propose a microcapsule pump which is one of the realizable and useful micromachines today. We show that the microcapsule pump produces a microflow from the microstorage tank of solution, unlike other pumps, which pumps out the liquid from the inlet to the outlet of the flow. The proposed microcapsule pump has the function of the microflow from the storage tank, depending on the environmental condition. For example, this microactuator system can be applied to drug delivery requiring a long time, such as insulin injection for diabetic patients, and other medical applications. This microcapsule pump structurally consists of an inlet with a semipermeable membrane, an outlet with a one-way valve and a storage tank controlled by osmotic pressure. The outflow side has a one -way valve that prevents backward flow of the solution from the outlet to the inlet. Since this pump is applied to medical science, it is of a very simple structure and easy to handle. It is possible that the outflow volume of internal solution and the rate of osmosis can be changed using semipermeable membranes with different properties. The salient feature of this proposed actuator is that an external driving power supply is not required in this microsystem. The size of the prototype of this microcapsule pump is 5 mm in diameter and 9.8 mm in length. Its weight is 0.7 g.
- 1 January 1992
- Published by Japan Society of Mechanical Engineers in TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C
- Vol. 58 (552) , 2483-2488
Open AccessStructure and Mechanism of Microcapsule Pump Using Osmotic Pressure Actuator.
We propose a microcapsule pump which is one of the realizable and useful micromachines today. We show that the microcapsule pump produces a microflow from the microstorage tank of solution, unlike other pumps, which pumps out the liquid from the inlet to the outlet of the flow. The proposed microcapsule pump has the function of the microflow from the storage tank, depending on the environmental condition. For example, this microactuator system can be applied to drug delivery requiring a long time, such as insulin injection for diabetic patients, and other medical applications. This microcapsule pump structurally consists of an inlet with a semipermeable membrane, an outlet with a one-way valve and a storage tank controlled by osmotic pressure. The outflow side has a one -way valve that prevents backward flow of the solution from the outlet to the inlet. Since this pump is applied to medical science, it is of a very simple structure and easy to handle. It is possible that the outflow volume of internal solution and the rate of osmosis can be changed using semipermeable membranes with different properties. The salient feature of this proposed actuator is that an external driving power supply is not required in this microsystem. The size of the prototype of this microcapsule pump is 5 mm in diameter and 9.8 mm in length. Its weight is 0.7 g.
- 1 January 1992
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 110-115
Structure and mechanism of two types of micro-pump using polymer gel
Micropumps using polymer gel actuators are proposed and two prototypes developed are described. One is actuated by a highly water absorbing polymer gel, while the other is actuated by a thermoresponsive polymer gel. The first type, the micro-capsule pump using the highly water absorbing polymer gel, consists structurally of an inlet with a semipermeable membrane, an outlet with a one-way valve, and a storage tank controlled by the water absorbing polymer gel. The gel rests within a thin film, and the semipermeable membrane is located on the inlet side. The important feature of this actuator is that an external driving power supply is not required in this micropump. The second type, the micropump using the thermoresponsive polymer gel, has two one-way valves which make use of the highly water absorbing polymer gel as a blocking ball. The polymer gel actuator used is constituted of polyvinyl methyl ether (PVME) atatic polymer gel. Repeating the heating and cooling processes causes, the PVME to repeat its shrinking and swelling motions. The micropump was tested on switching heating by a nichrome wire with electric current.<>
- 1 January 1992
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 110-115
Structure and mechanism of two types of micro-pump using polymer gel
Micropumps using polymer gel actuators are proposed and two prototypes developed are described. One is actuated by a highly water absorbing polymer gel, while the other is actuated by a thermoresponsive polymer gel. The first type, the micro-capsule pump using the highly water absorbing polymer gel, consists structurally of an inlet with a semipermeable membrane, an outlet with a one-way valve, and a storage tank controlled by the water absorbing polymer gel. The gel rests within a thin film, and the semipermeable membrane is located on the inlet side. The important feature of this actuator is that an external driving power supply is not required in this micropump. The second type, the micropump using the thermoresponsive polymer gel, has two one-way valves which make use of the highly water absorbing polymer gel as a blocking ball. The polymer gel actuator used is constituted of polyvinyl methyl ether (PVME) atatic polymer gel. Repeating the heating and cooling processes causes, the PVME to repeat its shrinking and swelling motions. The micropump was tested on switching heating by a nichrome wire with electric current.<>