    Three‐Anchor Knotless Compression Bridges Improve Contact Mechanics in a Biomechanical Model of Large, Single‐Row Tendon Repairs

    by Nisha M. Kotta, Benjamin L. Smith, Roger Quesada‐Jimenez, Anthony N. Khoury, Benjamin G. Domb

    Purpose: To investigate the influence of anchor density on tendon footprint contact mechanics in knotless all‐suture anchor compression bridge constructs. Methods: Unicortical polyurethane solid foam blocks with a cancellous density of 20 lb/ft 3 and a cortical density of 40 lb/ft 3 simulated bone. Tendons were replicated with 4.76‐mm‐thick 40A durometer polyurethane rubber sized to 27 × 12 mm. Test groups consisted of two 2.6‐mm all‐suture anchor single‐row knotless compression bridge constructs evaluated at interanchor distances of 10, 15, 20, and 25 mm. A 3‐anchor construct was also evaluated for the 25‐mm (large tear) condition. The repair sutures of each construct were individually hooked onto a zeroed, handheld force gauge and manually tensioned to create a minor (2 ), compressive force (N), and contact pressure (kPa) were recorded from the loaded sensing elements in the bridge region. Results: The 25‐mm, 3‐anchor construct resulted in significantly greater compressive force than any of the 2‐anchor groups (107 ± 9 N, P < .001). Adding a third anchor to the 25‐mm bridge resulted in 37% more compressive force when compared with its 2‐anchor equivalent. Contact area increased linearly with increasing bridge length. The largest contact area measured at 195 ± 11 mm 2 , observed in the 25‐mm bridge distance with both the 2‐ and 3‐anchor constructs. The largest contact pressure was achieved in the 10 mm group (1020 ± 58 kPa). Contact pressure significantly decreased with increasing bridge distance and was restored with the addition of a third anchor (683 ± 96 kPa) ( P < .001). Conclusions: An inverse relation was identified wherein increasing knotless suture bridge length decreased tendon footprint contact pressure in single‐row repairs. The addition of an in‐line third anchor in a simulated large‐tear model (25 mm) improved contact pressure and compressive force. Clinical Relevance: The addition of a third knotless all‐suture anchor to large single‐row suture bridge repairs shows a noticeable improvement in tendon footprint restoration at time zero.


  • Open Access

    Chronic deltoid ligament insufficiency results in greater anterior translation and positive arthroscopic drive-through sign

    by Ryan B. Rigby, Sarah J. Ingwer, Nathan Ptak, Justin Fleming, Oliver Hauck, Anthony N. Khoury


  • Circumferential Labral Reconstruction With Knotless All-Suture Anchors Restores Hip Distractive Stability: A Cadaveric Biomechanical Analysis

    by Ajay C. Lall, Benjamin L. Smith, Ady H. Kahana-Rojkind, Anthony N. Khoury, Coen A. Wijdicks, Benjamin G. Domb

    Background: The essential component of managing femoroacetabular impingement involves restoration of the original labral function. Circumferential labral reconstruction (CLR) has shown positive results. However, biomechanical studies of CLR are limited and have not established the efficacy of the modern knotless all-suture anchor (ASA) pull-through technique. Hypotheses: (1) CLR with knotless ASA fixation will restore native labral suction seal biomechanics; (2) tensioning the ASA to a high-tension state will increase the peak distractive force. Study Design: Controlled laboratory study. Methods: Eight fresh-frozen human cadaveric hips were dissected free of all soft tissue except the native labrum and transverse acetabular ligament. On an electromechanical testing system, the hips were compressively loaded to 250 N to initiate a suction seal and distracted at a rate of 10 mm/s until rupture of the suction seal. Hips were tested in 4 states: intact labrum, full labral removal, knotless CLR with moderate anchor tension, and CLR with high anchor tension. Peak distractive force (in newtons) was compared using repeated measures analysis of variance ( P < .05). Acetabular bevel angles (θ) were measured at labral clockface positions outside the transverse acetabular ligament using a 3-dimensional digitizer stylus after rim preparation. Linear regression plots compared θ and peak distractive force in the CLR state. Results: Peak force values were 138.5 ± 13.6 N (mean ± SE) for the intact labrum, 18.4 ± 2.79 N for labral excision, 95.4 ± 23.3 N for moderate-tension CLR, and 126.2 ± 27.3 N for high-tension CLR. Significant differences were observed only when full labral removal was compared with the other conditions: intact ( P < .001), moderate-tension CLR ( P = .016), and high-tension CLR ( P = .002). Steeper acetabular bevel angles (smaller θ) were correlated with greater suction seal restoration ( P < .05). Conclusion: CLR restored distractive stability on average to 82.0% of the intact value after labral deficiency. Retensioning did not significantly increase peak distractive forces. Clinical Relevance: These findings provide biomechanical validation supporting CLR using knotless ASAs in an effort to minimize volumetric bone loss and provide other surgical advantages. The prepared rim's bevel angle may be an important variable to optimize for improved suction seal restoration.


  • Anterior Cruciate Ligament Repair With Suture Tape Augmentation of Proximal Tears and Early Anterior Cruciate Ligament Reconstruction With Suture Tape Augmentation Result in Comparable Clinical Outcomes With Anterior Cruciate Ligament Reconstruction at 2‐Year Follow‐Up

    by Sebastien G. Simard, Christina J. Greenfield, Anthony N. Khoury

    Purpose: To compare the postoperative side‐to‐side laxity and short‐term clinical outcomes of patients who received primary anterior cruciate ligament (ACL) repair with suture tape augmentation, acute anterior cruciate ligament reconstruction (ACLR) with suture tape augmentation performed within 8 weeks of injury (ACLR acute ), or ACLR beyond 8 weeks of injury. Methods: After institutional review board approval was obtained, 100 patients were enrolled in this prospective trial: 34 primary ACL repair with suture tape augmentation, 33 ACLRs performed within 8 weeks of injury (ACLR acute ), and 33 ACLRs. Patients were allocated to ACL repair if a proximal avulsion was present with good tissue quality (Sherman type 1), confirmed by intraoperative diagnostic arthroscopy. Preoperative side‐to‐side anteroposterior knee laxity was assessed with KT‐1000 arthrometer, and patient‐reported outcomes (PROs) including the visual analog scale, Marx activity scale, Veterans RAND 12‐item health survey (VR‐12 physical & mental), Single Assessment Numeric Evaluation, Knee Injury and Osteoarthritis Outcome Score survey subscales, and range of motion were collected. These objective and subjective measures were repeated at regular intervals postoperatively through 2 years. Minimal clinically important difference calculations were performed assessing postoperative PRO changes at 2 years compared with preoperative. Results: The average time from injury to surgery was 5.03 ± 1.2 weeks for the ACL repair group, 5.09 ± 0.74 weeks for the ACLR acute , and 43.22 ± 33.5 weeks for the ACLR group. Postoperatively, the KT‐1000 side‐to‐side laxity difference for 30 lbs was determined to be 0.1 ± 0.37 (95% confidence interval [CI] –0.7 to 0.8) for ACL repair versus ACLR ( P < .0001), –0.8 ± 0.35 (95% CI –1.5 to –0.1) for ACLR acute versus ACLR ( P < .0001), and 0.8 ± 0.40 (95% CI 0.0‐1.6) for ACL repair versus ACLR acute ( P < .0001). The data reveal ACL repair and ACLR acute are noninferior to ACLR at 2‐year follow‐up. The postoperative difference from baseline for all PROs demonstrated improvement for all PROs. Magnetic resonance imaging at 1 year revealed tissue healing for the 3 ACL injury treatment groups. Conclusions: Patients who underwent ACL repair of proximal tears with suture tape augmentation or ACL reconstruction within 8 weeks from injury resulted in noninferior side‐to‐side knee laxity, comparable PROs, and similar range of motion at 2‐year follow‐up compared with ACLR. Level of Evidence: Level II, prospective comparative study.


  • Sagittal Pelvic Tilt Directly Influences the Ischiofemoral Space: A Cadaveric Study

    by Luke Spencer-Gardner, Brandon Nunley, Juan Gómez-Hoyos, Joel Wells, Anthony N. Khoury

    Background: Ischiofemoral impingement (IFI) is understood to be a pain generator in the deep gluteal space. Femoral position is known to influence the ischiofemoral space (IFS), but there has been no study examining the effect of sagittal pelvic tilt on the IFS. The purpose of this study was to determine whether changes in pelvic tilt in the sagittal plane lead to changes in the dimensions of the IFS. Materials and Methods: Five fresh frozen cadavers (10 hips) were used for this anatomic study. The specimens were skeletonized and placed in the prone position with the pelvis fixed to a custom-built hinged table. A digital inclinometer was used to tilt the pelvis −10°, 0°, and 10° simulating posterior, neutral, and anterior pelvic tilt, respectively. Digital calipers were used to measure the dimensions of the IFS in all three positions of sagittal pelvic tilt. Results: Changes in pelvic tilt resulted in significant changes in the dimensions of the IFS. Mean IFS dimensions measured 29.3±9.7 mm, 37.2±9.0 mm, and 24.3±9.2 mm in the neutral, anterior, and posterior pelvic tilt positions, respectively ( P <.0001). Conclusion: Changes in sagittal pelvic tilt influence the dimensions of the IFS, with posterior pelvic tilt noted to significantly decrease the IFS when compared with neutral and anterior pelvic tilt. These findings suggest that further evaluation of sagittal spinopelvic balance in the etiology of symptomatic IFI may be warranted. [ Orthopedics . 2024;47(3):167–171.]


  • Double-Row Achilles Insertional Repair With Rip-Stop Increases Construct Strength Compared to Traditional Techniques: A Biomechanical Study

    by Anand Vora, Sarah J. Ingwer, Maria Withrow, Nicholas Denove, Oliver Hauck, Anthony Khoury

    Background: Although double-row suture-anchored (DRSA) techniques for Achilles insertional tendinosis has proven successful, a reoccurring failure mode not yet addressed is suture tearing through the tendon. This study aims to address suture tearing by incorporating a rip-stop element. Authors hypothesized that the Rip-Stop group would demonstrate increased strength compared with more traditional techniques. Methods: 12 paired cadaveric feet were used in this study (n = 24). One sample from each pair was assigned to receive the standard double-row (SDR) Achilles repair with 4.75-mm knotless anchors (n = 12). The control’s matched sides were divided between 2 DRSA bridge groups: modified double-row (MDR) bridge with 3.9-mm anchors or rip-stop double-row (RS-DR) bridge repair with soft proximal anchors and 3.9-mm anchored distal row. In neutral position, specimens underwent 1000 cycles (20-100 N) followed by load to failure. Displacements, stiffness, ultimate load, and failure mode were recorded. Results: RS-DR had the lowest initial displacement values followed by SDR and MDR (1.3 ± 0.4, 2.7 ± 1.4, and 3.2 ± 1.3 mm, respectively). Significance was detected when comparing initial displacement of RS-DR to MDR ( P = .038). Cyclic displacement was lowest for RS-DR, followed by MDR and SDR (1.6 ± 0.9, 2.2 ± 1.1, and 4.5 ± 3.2 mm, respectively). Cyclic stiffness was similar for RS-DR and MDR (89.1 ± 24.6 and 81.9 ± 5.6 N/mm, respectively). RS-DR ultimate load (1116.8 ± 405.7 N) was statistically greater than SDR (465.6 ± 352.7, P = .003). Conclusion: RS-DR–repaired specimens demonstrated a decrease in displacement values and increased ultimate load and stiffness when compared to other groups. Results of this cadaveric model suggest that the addition of a rip-stop to DRSA Achilles repair is more impactful than anchor size. Limitations include that this was a time-zero biomechanical study, which cannot simulate the performance of the repairs during postoperative healing and recovery. Clinical Relevance: A rip-stop technique for Achilles repair effectively improves dynamic mechanical characteristics and may mitigate suture tearing through tendon in a patient cohort.


  • Open Access

    Cumulative group metrics: a new and efficient method to measure the scientific impact of research groups

    by Uta Msc Moll, Christopher L. Camp, Asheesh Bedi, Anthony N. Msc Khoury, Sarah M. Msc Villinger, Laurence D. Md Higgins, Coen A. MSc Wijdicks

    Background: Various metrics have emerged for assessing scientific impact, most of which are based on complex calculations and, in many cases, are not freely available. Moreover, most of these metrics are not intended for assessing the scientific impact of research groups. Cumulative group metrics are proposed as an efficient and cost-effective strategy for measuring group scientific impact. Materials and methods: The authors collected peer-reviewed output in 2020 from two academic orthopedic surgery departments [University of Michigan (UM) and Mayo Clinic Rochester (MC)] and one medical device research department [Arthrex Inc. (AI)]. The sites evaluated the Cumulative Group Number of Publications (CGNP), Cumulative Journal Impact Factor (CJIF), Cumulative CiteScore (CCS), Cumulative SCImago Journal Rank (CSJR), and Cumulative Source Normalized Impact per Paper (CSNIP) for the three institutions. Results: In 2020, UM published 159 peer-reviewed studies, MC published 347 peer-reviewed studies, and AI supported 141 publications. The UM publications achieved a CJIF of 513, a CCS of 891, a CSJR of 255, and a CSNIP of 247. The MC publications achieved a CJIF of 956, a CCS of 1568, a CSJR of 485, and a CSNIP of 508. AI-supported publications achieved a CJIF of 314, a CCS of 598, a CSJR of 189, and a CSNIP of 189. Conclusion: The presented cumulative group metrics are an effective tool to assess the scientific impact of a research group. The cumulative submetrics can further evaluate research groups compared with other departments due to field normalization. Department leadership and funding agencies can utilize these metrics to evaluate research output quantitatively and qualitatively.


  • Open Access

    Single Biotenodesis Screw vs Biotenodesis Screw with Cortical Button Tension Slide Technique for Flexor Hallucis Longus Transfer: A Biomechanical Analysis

    by Kaitlin C. Neary, Sarah J. McClish, Anthony N. Khoury, Nick Denove, Coen A. Wijdicks

    Category: Ankle; Hindfoot; Sports; Other Introduction/Purpose: Restoration of functional plantarflexion of the ankle joint following chronic Achilles injury is achieved through transfer of the flexor hallucis longus (FHL) tendon. Fixation of the FHL tendon transfer with a cortical button tension slide technique is an advancement that has not been measured against traditional methods. The purpose of this study is to evaluate the biomechanical differences between a single biotenodesis screw versus biotenodesis screw with cortical button tension slide technique for the fixation of FHL transfer. The authors hypothesize a biomechanical advantage for the tension slide technique compared to the biotenodesis screw alone for fixation of the flexor hallucis longus in chronic Achilles pathology. Methods: 12 pairs (n=24) of fresh-frozen cadaveric tibia-to-toe samples (6 male, 6 female) were utilized to assess the biomechanics of FHL tendon transfer fixation. All specimens underwent bone density analysis. Each pair of cadaveric samples were randomized to receive either the biotenodesis screw or the tension slide technique. FHL tendon transfer was performed via standard technique using a 6.25x15mm biotenodesis screw with the foot in 20 degrees plantarflexion. A 2.6x12mm cortical button was inserted and FHL tendon was introduced with a tension-slide technique. Biomechanical loading was applied between 20N and 60N at a rate of 1Hz for 100 cycles. Post-cyclic load to failure occurred at 1.25mm/sec. Cyclic displacement, structural stiffness, and ultimate load were derived from resultant load-displacement curves. Student t-tests were used to evaluate significant effects between both FHL tendon transfer techniques. Linear regression analysis was performed to assess interactions between bone density and strength of FHL tendon transfer. Results: Average tendon diameter of the 24 FHL samples was 5.44+-0.46 mm. Average bone density for all 24 calcaneus samples was determined to be 1.06+-0.08 g/cm2. Loading data was normalized with respect to bone density and tendon diameter to account for inherent anatomical differences between cadaveric specimens. The addition of a cortical button for FHL transfer to the calcaneus did not significantly affect cyclic displacement (0.78+-0.52mm vs 0.87+-0.80mm) or structural stiffness (162.11+- 43.34N/mm vs. 167.57+-49.19N/mm). Addition of the cortical button to the FHL tendon transfer construct resulted in a 34% significant increase in ultimate load (343.72+-68.93 N) compared to biotenodesis screw alone (255.62+-77.17 N) (p=0.0002). Linear regression analyses did not reveal any significant interactions between bone density and FHL tendon transfer technique. Conclusion: Enhanced strength can be achieved for Achilles pathology repaired with FHL tendon transfer utilizing a biotenodesis screw and cortical button tension slide technique demonstrated by a statistically significant 34% increase in ultimate load, subsequent to cyclic loading. Cortical buttons in the setting of FHL tendon transfer to the calcaneus offers an additional level of support in the case of extreme tendon transfer failure.