Rajiv A. Jadhav
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rajiv A. Jadhav has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Vinod K. Ahirrao
Wockhardt Research Centre, D-4, MIDC, Chikalthana, Aurangabad, 431006, India
7 shared publications Ravindra D. Yeole
Wockhardt Research Centre, Aurangabad, India
6 shared publications- Kiran R. Patil
Wockhardt Research Centre, Aurangabad, India
4 shared publications Vipul P. Rane
Wockhardt Research Centre, Aurangabad, India
4 shared publicationsKiran R. Patil
Wockhardt Research Centre
3 shared publications- Saroj R. Bembalkar
Department of Chemistry, Deogiri College, Aurangabad 431004, India
2 shared publications
Latest Publications
- Open Access
- 19 August 2022
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 34 (9) , 2227-2234
Novel Analytical Approach for the Estimation of Oxalic Acid Content in Sodium Ascorbate by Reversed Phase-High Performance Liquid Chromatography
A simple and novel reverse phase-high performance liquid chromatography (RP-HPLC) method employing Triart C18 column has been developed and validated for the estimation of oxalic acid content in sodium ascorbate drug substance and drug product. Forced degradation study of sodium ascorbate was performed at acid, base, oxidative, photolytic and thermal stress conditions. Oxalic acid was found as final degradants. The separation was achieved in isocratic mode using mixture of tetrabutylammonium hydroxide-phosphate buffer (pH 7.0) and acetonitrile in the ratio of 80:20; v/v as mobile phase at a flow rate of 1.0 mL min–1 using UV detector. The method was validated as per the ICH guideline (Q2R1) for accurate and precise quantification of oxalic acid content in sodium ascorbate. The obtained limit of quantification of oxalic acid was 0.034%. Mean recovery of oxalic acid was found to be 98.9 ± 8.7%. Presented method could be applied for the estimation of oxalic acid content in sodium ascorbate at pharmaceutical laboratories.
- 19 August 2022
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 34 (9) , 2227-2234
Open AccessNovel Analytical Approach for the Estimation of Oxalic Acid Content in Sodium Ascorbate by Reversed Phase-High Performance Liquid Chromatography
A simple and novel reverse phase-high performance liquid chromatography (RP-HPLC) method employing Triart C18 column has been developed and validated for the estimation of oxalic acid content in sodium ascorbate drug substance and drug product. Forced degradation study of sodium ascorbate was performed at acid, base, oxidative, photolytic and thermal stress conditions. Oxalic acid was found as final degradants. The separation was achieved in isocratic mode using mixture of tetrabutylammonium hydroxide-phosphate buffer (pH 7.0) and acetonitrile in the ratio of 80:20; v/v as mobile phase at a flow rate of 1.0 mL min–1 using UV detector. The method was validated as per the ICH guideline (Q2R1) for accurate and precise quantification of oxalic acid content in sodium ascorbate. The obtained limit of quantification of oxalic acid was 0.034%. Mean recovery of oxalic acid was found to be 98.9 ± 8.7%. Presented method could be applied for the estimation of oxalic acid content in sodium ascorbate at pharmaceutical laboratories.
- 1 February 2021
- Published by Wiley in Biomedical Chromatography
- Vol. 35 (6) , e5079
Reverse‐phase chiral high‐performance liquid chromatography for separation of a diastereomer in alalevonadifloxacin: A novel antibacterial agent
Alalevonadifloxacin (ALA) is a novel antibacterial drug, recently launched in India to treat infections caused by Gram‐positive bacteria. In present work, a chiral high‐performance liquid chromatographic method was developed and validated for the quantification of a diastereomeric impurity (DI) in ALA. The separation was achieved on Pirkle type (R,R) Whelk‐O1 chiral stationary phase, using ammonium formate buffer and acetonitrile in gradient fashion at a flow rate of 1.5 ml/min. The method was extensively validated for the quantification of DI in ALA. The detector response for DI was linear over the concentration range of 0.24–4.78 μg/ml. Limit of quantitation and limit of detection for DI were 0.24 and 0.07 μg/ml respectively. The mean recovery of the DI was 103.47 ± 5.14%. The impact of column temperature on the chiral separation was evaluated. The method was employed for controlling diastereomeric impurity in the batches of ALA used in preclinical studies.
- 1 February 2021
- Published by Wiley in Biomedical Chromatography
- Vol. 35 (6) , e5079
Reverse‐phase chiral high‐performance liquid chromatography for separation of a diastereomer in alalevonadifloxacin: A novel antibacterial agent
Alalevonadifloxacin (ALA) is a novel antibacterial drug, recently launched in India to treat infections caused by Gram‐positive bacteria. In present work, a chiral high‐performance liquid chromatographic method was developed and validated for the quantification of a diastereomeric impurity (DI) in ALA. The separation was achieved on Pirkle type (R,R) Whelk‐O1 chiral stationary phase, using ammonium formate buffer and acetonitrile in gradient fashion at a flow rate of 1.5 ml/min. The method was extensively validated for the quantification of DI in ALA. The detector response for DI was linear over the concentration range of 0.24–4.78 μg/ml. Limit of quantitation and limit of detection for DI were 0.24 and 0.07 μg/ml respectively. The mean recovery of the DI was 103.47 ± 5.14%. The impact of column temperature on the chiral separation was evaluated. The method was employed for controlling diastereomeric impurity in the batches of ALA used in preclinical studies.
- 13 July 2020
- Published by Springer Nature in Chromatographia
- Vol. 83 (9) , 1107-1119
Development and Validation of Rapid Stability-Indicating RP-HPLC Method for Assay and Related Substances of Solifenacin Succinate
- 13 July 2020
- Published by Springer Nature in Chromatographia
- Vol. 83 (9) , 1107-1119
Development and Validation of Rapid Stability-Indicating RP-HPLC Method for Assay and Related Substances of Solifenacin Succinate
- 13 July 2020
- Published by Springer Nature in Chromatographia
- Vol. 83 (9) , 1095-1105
An Efficient HPLC–MS Method for Impurity Profile of Ertapenem
- 13 July 2020
- Published by Springer Nature in Chromatographia
- Vol. 83 (9) , 1095-1105
An Efficient HPLC–MS Method for Impurity Profile of Ertapenem
- Open Access
- 17 June 2020
- Published by Springer Nature in Journal of Analytical Science and Technology
- Vol. 11 (1) , 1-9
Time-dependent selected reaction monitoring-based GC-MS/MS method for estimation of genotoxic impurities in new antibacterial agent: alalevonadifloxacin mesylate
Alalevonadifloxacin mesylate (ALA), pro-drug of levonadifloxacin is a new antibiotic approved in India to treat infections caused by Gram-positive bacteria. Alkyl mesylates (AMs) are known genotoxic impurities (GTI’s) formed in drug substances isolated as mesylate salts. Time-dependent selected reaction monitoring (t-SRM)-based gas chromatography tandem mass spectrometry (GC-MS/MS) method has been developed for trace estimation of AMs, namely, methyl methane sulfonate (MMS), ethyl methane sulfonate (EMS) and isopropyl methane sulfonate (IMS) in ALA. Liquid-liquid extraction (LLE) procedure using dichloromethane (DCM) as an extracting solvent was employed to extract AMs from the drug substance. Automatic selective reaction monitoring (auto-SRM) tool was applied to identify the most intense SRM pair of the ions to achieve the highest sensitivity. The method was validated in terms of specificity, linearity, sensitivity, precision, and accuracy. The limit of quantitation (LOQ) for the MMS, EMS and IMS were 5, 10, and 20 ng/g of ALA, respectively. For all analytes, the correlation coefficient (R) were greater than 0.9975 in the concentration range of 3.0–260 ng/mL. Mean recovery of all analytes was in the range of 91.77 to 97.65%.
- 17 June 2020
- Published by Springer Nature in Journal of Analytical Science and Technology
- Vol. 11 (1) , 1-9
Open AccessTime-dependent selected reaction monitoring-based GC-MS/MS method for estimation of genotoxic impurities in new antibacterial agent: alalevonadifloxacin mesylate
Alalevonadifloxacin mesylate (ALA), pro-drug of levonadifloxacin is a new antibiotic approved in India to treat infections caused by Gram-positive bacteria. Alkyl mesylates (AMs) are known genotoxic impurities (GTI’s) formed in drug substances isolated as mesylate salts. Time-dependent selected reaction monitoring (t-SRM)-based gas chromatography tandem mass spectrometry (GC-MS/MS) method has been developed for trace estimation of AMs, namely, methyl methane sulfonate (MMS), ethyl methane sulfonate (EMS) and isopropyl methane sulfonate (IMS) in ALA. Liquid-liquid extraction (LLE) procedure using dichloromethane (DCM) as an extracting solvent was employed to extract AMs from the drug substance. Automatic selective reaction monitoring (auto-SRM) tool was applied to identify the most intense SRM pair of the ions to achieve the highest sensitivity. The method was validated in terms of specificity, linearity, sensitivity, precision, and accuracy. The limit of quantitation (LOQ) for the MMS, EMS and IMS were 5, 10, and 20 ng/g of ALA, respectively. For all analytes, the correlation coefficient (R) were greater than 0.9975 in the concentration range of 3.0–260 ng/mL. Mean recovery of all analytes was in the range of 91.77 to 97.65%.
- 18 December 2019
- Published by Springer Nature in Chromatographia
- Vol. 83 (3) , 423-437
Impurity Profiling of a Novel β-Lactam Enhancer: Zidebactam
- 18 December 2019
- Published by Springer Nature in Chromatographia
- Vol. 83 (3) , 423-437
Impurity Profiling of a Novel β-Lactam Enhancer: Zidebactam
- 3 September 2019
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 9 (5) , 625-633
Enantiomeric Separation and Thermodynamic investigation of (R)-5-[1-(4-Nitrobenzylsulfonyloxy)-ethyl]-5-(pyridine-2-yl)- [1,3,4]-thiadiazole, a Key Intermediate of Nafithromycin
A selective and precise chiral high performance liquid chromatography method for the separation of (R)-5-[1-(4-Nitrobenzylsulfonyloxy)-ethyl]-5-(pyridine-2-yl)-[1, 3, 4]-thiadiazole (RE) has been developed and validated. It is an intermediate of a novel antibiotic nafithromycin. Nafithromycin is a ketolide class antibiotic being developed to treat community acquired bacterial pneumonia. Enantiomeric separation was achieved on Chiralpak IA column using mobile phase consisting of n-hexane and ethanol in the ratio of (15:85; v/v) with the resolution of more than 3. Separation was achieved at flow rate of 1.0 mL min−1 and column temperature 30°C. The eluent was monitored at 254 nm. The developed method was validated as per the guideline. The method was found to be selective, precise, accurate and linear. Limit of detection and limit of quantification of the undesired enantiomer (S)-5-[1-(4-Nitrobenzylsulfonyloxy)-ethyl]-5-(pyridine-2-yl)- [1, 3, 4]-thiadiazole (SE) was 0.11 and 0.35 μgmL−1 respectively. Recovery of the SE was found to be in the range of 104.52 % and 105.83 %. The impact of thermodynamic parameters on the chiral separation was evaluated.
- 3 September 2019
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 9 (5) , 625-633
Enantiomeric Separation and Thermodynamic investigation of (R)-5-[1-(4-Nitrobenzylsulfonyloxy)-ethyl]-5-(pyridine-2-yl)- [1,3,4]-thiadiazole, a Key Intermediate of Nafithromycin
A selective and precise chiral high performance liquid chromatography method for the separation of (R)-5-[1-(4-Nitrobenzylsulfonyloxy)-ethyl]-5-(pyridine-2-yl)-[1, 3, 4]-thiadiazole (RE) has been developed and validated. It is an intermediate of a novel antibiotic nafithromycin. Nafithromycin is a ketolide class antibiotic being developed to treat community acquired bacterial pneumonia. Enantiomeric separation was achieved on Chiralpak IA column using mobile phase consisting of n-hexane and ethanol in the ratio of (15:85; v/v) with the resolution of more than 3. Separation was achieved at flow rate of 1.0 mL min−1 and column temperature 30°C. The eluent was monitored at 254 nm. The developed method was validated as per the guideline. The method was found to be selective, precise, accurate and linear. Limit of detection and limit of quantification of the undesired enantiomer (S)-5-[1-(4-Nitrobenzylsulfonyloxy)-ethyl]-5-(pyridine-2-yl)- [1, 3, 4]-thiadiazole (SE) was 0.11 and 0.35 μgmL−1 respectively. Recovery of the SE was found to be in the range of 104.52 % and 105.83 %. The impact of thermodynamic parameters on the chiral separation was evaluated.
- 28 May 2019
- Published by Springer Nature in Chromatographia
- Vol. 82 (7) , 1059-1068
Identification and Quantification of Related Impurities of a Novel Ketolide Antibiotic Nafithromycin
- 28 May 2019
- Published by Springer Nature in Chromatographia
- Vol. 82 (7) , 1059-1068
Identification and Quantification of Related Impurities of a Novel Ketolide Antibiotic Nafithromycin
- 29 April 2019
- Published by Wiley in Biomedical Chromatography
- Vol. 33 (9) , e4566
Chiral separation and thermodynamic investigation of WCK 3023: A novel oxazolidinone antibacterial agent, application to pre‐clinical pharmacokinetic study
A chiral liquid chromatographic method was developed and validated for the quantification of R‐enantiomer impurity (RE) in WCK 3023 (S‐enantiomer), a new drug substance. The separation was achieved on Chiralpak IA (amylose‐based immobilized chiral stationary phase), using a mobile phase consisting of n‐hexane–ethanol–trifluoroacetic acid (70:30:0.2, v/v/v) at a flow rate of 1.0 mL/min. The method was extensively validated for the quantification of RE in WCK 3023 and proved to be robust. For RE the detector response was linear over the concentration range of 0.11–5 μg/mL. The limit of quantitation and limit of detection for RE were 0.11 and 0.04 μg/mL respectively. Average recovery of the RE was in the range of 98.11–99.55%. The developed method was specific, sensitive, precise and accurate for quantitative determination of RE in WCK 3023. The impact of thermodynamic parameters on the chiral separation was evaluated. The method was employed for controlling the enantiomeric impurity in the lots of WCK 3023 used for pre‐clinical studies. The method was successfully applied to evaluate the possible conversion of WCK 3023 to RE in rat serum samples during pre‐clinical pharmacokinetic studies.
- 29 April 2019
- Published by Wiley in Biomedical Chromatography
- Vol. 33 (9) , e4566
Chiral separation and thermodynamic investigation of WCK 3023: A novel oxazolidinone antibacterial agent, application to pre‐clinical pharmacokinetic study
A chiral liquid chromatographic method was developed and validated for the quantification of R‐enantiomer impurity (RE) in WCK 3023 (S‐enantiomer), a new drug substance. The separation was achieved on Chiralpak IA (amylose‐based immobilized chiral stationary phase), using a mobile phase consisting of n‐hexane–ethanol–trifluoroacetic acid (70:30:0.2, v/v/v) at a flow rate of 1.0 mL/min. The method was extensively validated for the quantification of RE in WCK 3023 and proved to be robust. For RE the detector response was linear over the concentration range of 0.11–5 μg/mL. The limit of quantitation and limit of detection for RE were 0.11 and 0.04 μg/mL respectively. Average recovery of the RE was in the range of 98.11–99.55%. The developed method was specific, sensitive, precise and accurate for quantitative determination of RE in WCK 3023. The impact of thermodynamic parameters on the chiral separation was evaluated. The method was employed for controlling the enantiomeric impurity in the lots of WCK 3023 used for pre‐clinical studies. The method was successfully applied to evaluate the possible conversion of WCK 3023 to RE in rat serum samples during pre‐clinical pharmacokinetic studies.